PubMed Health⌕ Search

Biomedical subjects

W Harry Hannon

Publications and source records attributed to W Harry Hannon.

12 recordsLinked to original sources

Metabolic disorders detectable by tandem mass spectrometry and unexpected early childhood mortality: a population-based study.

Investigators have reported that certain metabolic disorders (fatty acid oxidation (FAO) disorders and organic acidemias) contribute to unexpected early childhood deaths. We estimated the contribution of these metabolic disorders to a population-based sample of unexpected early childhood deaths. The study population included children less than 3 years of age who died during 1996-2001 and whose deaths were investigated by the Virginia Office of the Chief Medical Examiner (ME). Dried post-mortem blood on filter paper was sent to a reference laboratory for metabolic screening by tandem mass spectrometry. When molecular DNA analysis was available to identify known gene mutations, positive screens were confirmed. If molecular DNA analysis for a suspected disorder was not available, tandem mass spectrometry was performed on newborn blood spots when available. If DNA analysis was not available and newborn blood spots could not be obtained, an independent expert biochemical geneticist confirmed the post-mortem interpretation. We obtained screening results for 793 (88%) of 904 children examined. Eight children had a positive screen for FAO disorders or organic acidemias. One child would not have benefited from identification in the newborn period. However, seven children's outcomes might have been improved had they been identified during the newborn period and effectively treated. Post-mortem metabolic screening may identify a cause of death for about 1% of children who die unexpectedly before 3 years of age, allowing for identification and treatment of affected siblings. Identifying and treating affected children during the newborn period may offer an opportunity to reduce early childhood mortality.

Acyl-CoA Dehydrogenase↗

National evaluation of US newborn screening system components.

Newborn screening has existed as a state-based public health service since the early 1960s. Every state and most territorial jurisdictions have comprehensive newborn screening programs in place, but in the United States a national newborn screening policy does not exist. This results in different administrative infrastructures, screening requirements, laboratory and follow-up services, medical management approaches, and related activities across the country. Federal initiatives and support have contributed to limited evaluations of various aspects of individual newborn screening programs at the national level, but funding is an issue. The national evaluation strategies have taken various forms, all with the intent of improving the screening system through review of actions taken and suggestions for future improvements. While participation in the national evaluation effort for newborn screening laboratory practices includes all US programs, and this has aided in improving quality and harmonizing protocols, other national evaluation activities have been only moderately successful. National data reporting of quality indicators for various program elements must be comprehensive and timely, and the elements must be universally accepted in order to meet the evaluation and improvement needs of the national newborn screening system. A comprehensive real time national evaluation activity will likely require additional resources and enforcement incentives. Limited federal actions through grant incentives and selected reporting requirements provide a possible means of stimulating programs to participate in national harmonization efforts.

Costs and Cost Analysis↗

Storage and use of residual dried blood spots from state newborn screening programs.

OBJECTIVES: To provide current data for policy discussions and to assess future needs among newborn screening programs regarding the storage and use of residual dried blood spots (DBS) in the United States. STUDY DESIGN: An electronic questionnaire was administered to U.S. state health department laboratory directors in 2003. RESULTS: Responses were received from 49 of the 50 states. Approximately half of them stored residual DBS for more than 6 months, 57% did not have a written policy that determines how residual DBS can or cannot be used, and 16% informed parents that DBS might be retained. Residual DBS were used by 74% of respondents for evaluation of newborn screening tests, by 52% for clinical or forensic testing, and by 28% for epidemiologic studies. Use of DBS was reported more frequently by states with extended storage. When asked if they might participate in an anonymous multistate epidemiologic study by contributing unlinked DBS, 41% responded affirmatively. CONCLUSIONS: More states have used residual DBS for evaluating newborn screening tests than for epidemiologic studies. There is potential interest among states in using unlinked DBS for multistate studies and a need for written policies addressing all uses of residual DBS.

Blood Specimen Collection↗

A screening system for detecting genetic risk markers of type 1 diabetes in dried blood spots.

BACKGROUND: Certain alleles among the genes that code for the human leukocyte antigens (HLA) confer susceptibility or resistance to the development of autoimmunity that causes type 1 diabetes (T1D). A number of ongoing diabetes research studies analyze dried blood spots (DBS) from newborn infants for HLA-D alleles to identify higher-risk children as early as possible. A commercially available assay to detect such alleles has recently become available using a dissociation- enhanced lanthanide fluorescence system found in many newborn screening laboratories. METHODS: We adapted the system for use with DBS and improved the sample set-up for greater efficiency. We also developed an independent system for data analysis based on a spreadsheet program. These modifications were applied to HLA-DQB1 gene locus (DQB) analysis of 117 newborn DBS, and the results we obtained were compared with independent reference values. RESULTS: Our assay modifications and independent data analysis improved sample throughput and result tabulation. DQB results from the modified assay were consistent with the reference values in all but one sample, which showed a partial match. CONCLUSIONS: The modifications described here make this commercially available assay more suitable for high-throughput applications such as newborn screening. Our results show that this system allows highly accurate detection of DQB alleles that influence T1D risk.

Blood Chemical Analysis↗

Development and characterization of dried blood spot materials for the measurement of immunoreactive trypsinogen.

OBJECTIVES: In response to increasing numbers of states in the US that test newborn babies for cystic fibrosis (CF), the Newborn Screening Quality Assurance Programme initiated a pilot proficiency testing programme for immunoreactive trypsinogen (IRT), the biomarker for CF. Dried blood spot specimens (DBS) were used to evaluate the performance of laboratories that screen babies for CF. METHODS: DBS were prepared from human whole blood enriched with physiologically relevant levels of IRT. Various methods of making IRT-enriched DBS were used to optimize the recovery and stability of the biomarker, including preparation of DBS from either intact or lysed red blood cells, varying the timing of IRT addition to blood before dispensing onto filter paper, adding a protease inhibitor cocktail, and treating serum with charcoal before IRT enrichment. The recovery and stability of IRT in DBS were assessed. Newborn screening laboratories were offered the opportunity to test blind-coded DBS in the pilot PT programme. RESULTS: IRT was stable in the filter paper matrix when stored for one year at either -20 degrees C or 4 degrees C. Fifty percent more IRT was recovered from DBS prepared with lysed red blood cells where the IRT was added to blood just before dispensing; however, protease inhibitors did not improve IRT recovery. CONCLUSIONS: IRT in the DBS matrix is stable and can be shipped worldwide under ambient conditions. Optimal IRT recovery was achieved by adjustment of DBS production practices. Laboratories receiving specimens accurately measured IRT by a variety of commercial and in-house methods.

Charcoal↗

Naming and counting disorders (conditions) included in newborn screening panels.

The rapid introduction of new technologies for newborn screening is affecting decisions about the disorders (conditions) that are required or offered as an option through public and private newborn screening. An American College of Medical Genetics report to the Health Resources and Services Administration summarized an extensive effort by a group of experts, with diverse expertise within the newborn screening system, to determine a process for selecting a uniform panel of newborn screening disorders. The expert panel did not propose a mechanism for counting or naming conditions. Differences in the nomenclature used to identify disorders have resulted in difficulties in developing a consensus listing and counting scheme for the disorders in the recommended uniform panel. We suggest a system of nomenclature that correlates the screening panel of disorders recommended in the American College of Medical Genetics report with the screening analyte and accepted standardized nomenclature. This nomenclature system is proposed to remove ambiguity and to increase national uniformity in naming and counting screening disorders.

Consensus↗

Applying public health strategies to primary immunodeficiency diseases: a potential approach to genetic disorders.

Primary immunodeficiency (PI) diseases are a group of primarily single-gene disorders of the immune system. Approximately 100 separate PI diseases have been described, but <20 probably account for >90% of cases. Although diverse, PI diseases share the common feature of susceptibility to infection and result in substantial morbidity and shortened life spans. Most important, prompt diagnosis and treatment can now lead to life-saving treatment and result in marked improvements in the quality and length of life for persons with PI diseases. In November 2001, a workshop was convened by CDC in Atlanta, Georgia, to discuss ways to improve health outcomes among persons with PI disease. A multidisciplinary panel of persons knowledgeable in PI diseases and public health met to identify and discuss public health strategies that can be applied to PI diseases and possibly for other genetic disorders. A systematic assessment based on the established public health framework was applied to the growing group of PI diseases, whose diverse genetic mutations span multiple components of the immune system but all lead to increased incidence and severity of infections. During the meeting, specialists in clinical immunology, public health, genetics, pediatrics, health communication, and ethics from state and federal agencies, academic centers, professional organizations, and advocacy foundations discussed the four components of the public health framework as they relate to PI diseases. These four components include 1) public health assessment (application of traditional public health methods to assess the occurrence and impact of PI diseases on communities); 2) population-based interventions (development, implementation, and evaluation of screening tests administered to newborns and clinical algorithms for early recognition of symptomatic persons to facilitate the earliest possible diagnosis and treatment for PI diseases); 3) evaluation of screening and diagnostic tools (to ensure their quality and appropriateness for identification of patients with PI diseases); and 4) communication (communication with and information dissemination to health-care providers and the public to facilitate prompt and appropriate diagnosis and intervention). The working group's deliberations focused on challenges and opportunities, priority research questions, and recommendations for future action for these four components. These recommendations, developed by workshop participants, will be useful to medical and public health professionals who are evaluating methods to increase recognition of PI diseases and other genetic disorders.

Adolescent↗

Performance characteristics of a new less sensitive HIV-1 enzyme immunoassay for use in estimating HIV seroincidence.

Less sensitive (LS) HIV-1 enzyme immunoassays (EIAs) have significantly improved the quantity and quality of HIV surveillance data. The first LS-HIV-1 EIA, the Abbott 3A11-LS, provided reliable incidence data, but the assay required specialized equipment, and the lack of available reagents made testing difficult. This study evaluated the use of an alternate assay, a modified version of the Vironostika HIV-1 EIA (Vironostika-LS), to be used for LS testing. The Vironostika-LS has similar performance characteristics to the Abbott 3A11-LS with additional advantages. This 96-well formatted assay is commonly found in public health laboratories for routine HIV-1 testing and can be used with both serum and dried blood spot specimens. The estimated mean time from seroconversion (defined using a standardized optical density cutoff of 1.0) with the Vironostika-LS was 170 days (95% CI, 145-200 days). When the Vironostika-LS was applied to a matched serum set previously tested with the Abbott 3A11-LS, the Vironostika-LS accurately identified 97% of specimens with recent or long-standing HIV infection. The paper also reports Vironostika-LS quality control guidelines and the results from 3 rounds of proficiency testing.

AIDS Serodiagnosis↗

Performance evaluation for screening laboratories of the Asia-Pacific region.

The Centers for Disease Control and Prevention (CDC) has a long history of involvement in quality assurance (QA) activities for support of newborn screening laboratories. Since 1978, CDC's Newborn Screening Quality Assurance Program (NSQAP), has distributed dried-blood spot (DBS) materials for external QA and has maintained related projects to serve newborn screening laboratories. The first DBS materials were distributed for congenital hypothyroidism screening in 1978 and by 2001, NSQAP had expanded to over 30 disorders and performance monitoring for all filter paper production lots from approved commercial sources. In 2001, there were 250 active NSQAP participants, 167 laboratories from 45 countries and 83 laboratories in the United States. Of these laboratories, 31 are from the Asia Pacific Region representing nine countries primarily for two disorders. In 1999, US laboratories had more errors for Performance Evaluation (PE) specimens than other laboratories; but in 2000, US laboratories had fewer errors. International laboratories reported 0.3% false-negative PE clinical assessments for congenital hypothyroidism and 0.5% for phenylketonuria (0.5%) in 2000. Paperless PE data-reporting operation using an Internet website has recently been implemented.

Asia, Southeastern↗

Report from a workshop on multianalyte microsphere assays.

Multiplexed assays using fluorescent microspheres is an exciting technique that has been gaining popularity among researchers, particularly those in the public health field. Part of its popularity is due to its flexibility, as both immunoassays and oligonucleotide hybridization assays can be developed on this platform. This report summarizes a workshop held by the Centers for Disease Control and Prevention that discussed issues surrounding these assays and the Luminex 100 xMAP instrument. Topics included instrumentation, assay design, sample matrix and volume, quality control, and development of commercial applications.

Animals↗

Serum TSH, T(4), and thyroid antibodies in the United States population (1988 to 1994): National Health and Nutrition Examination Survey (NHANES III).

NHANES III measured serum TSH, total serum T(4), antithyroperoxidase (TPOAb), and antithyroglobulin (TgAb) antibodies from a sample of 17,353 people aged > or =12 yr representing the geographic and ethnic distribution of the U.S. population. These data provide a reference for other studies of these analytes in the U.S. For the 16,533 people who did not report thyroid disease, goiter, or taking thyroid medications (disease-free population), we determined mean concentrations of TSH, T(4), TgAb, and TPOAb. A reference population of 13,344 people was selected from the disease-free population by excluding, in addition, those who were pregnant, taking androgens or estrogens, who had thyroid antibodies, or biochemical hypothyroidism or hyperthyroidism. The influence of demographics on TSH, T(4), and antibodies was examined. Hypothyroidism was found in 4.6% of the U.S. population (0.3% clinical and 4.3% subclinical) and hyperthyroidism in 1.3% (0.5% clinical and 0.7% subclinical). (Subclinical hypothyroidism is used in this paper to mean mild hypothyroidism, the term now preferred by the American Thyroid Association for the laboratory findings described.) For the disease-free population, mean serum TSH was 1.50 (95% confidence interval, 1.46-1.54) mIU/liter, was higher in females than males, and higher in white non-Hispanics (whites) [1.57 (1.52-1.62) mIU/liter] than black non-Hispanics (blacks) [1.18 (1.14-1.21) mIU/liter] (P < 0.001) or Mexican Americans [1.43 (1.40-1.46) mIU/liter] (P < 0.001). TgAb were positive in 10.4 +/- 0.5% and TPOAb, in 11.3 +/- 0.4%; positive antibodies were more prevalent in women than men, increased with age, and TPOAb were less prevalent in blacks (4.5 +/- 0.3%) than in whites (12.3 +/- 0.5%) (P < 0.001). TPOAb were significantly associated with hypo or hyperthyroidism, but TgAb were not. Using the reference population, geometric mean TSH was 1.40 +/- 0.02 mIU/liter and increased with age, and was significantly lower in blacks (1.18 +/- 0.02 mIU/liter) than whites (1.45 +/- 0.02 mIU/liter) (P < 0.001) and Mexican Americans (1.37 +/- 0.02 mIU/liter) (P < 0.001). Arithmetic mean total T(4) was 112.3 +/- 0.7 nmol/liter in the disease-free population and was consistently higher among Mexican Americans in all populations. In the reference population, mean total T(4) in Mexican Americans was (116.3 +/- 0.7 nmol/liter), significantly higher than whites (110.0 +/- 0.8 nmol/liter) or blacks (109.4 +/- 0.8 nmol/liter) (P < 0.0001). The difference persisted in all age groups. In summary, TSH and the prevalence of antithyroid antibodies are greater in females, increase with age, and are greater in whites and Mexican Americans than in blacks. TgAb alone in the absence of TPOAb is not significantly associated with thyroid disease. The lower prevalence of thyroid antibodies and lower TSH concentrations in blacks need more research to relate these findings to clinical status. A large proportion of the U.S. population unknowingly have laboratory evidence of thyroid disease, which supports the usefulness of screening for early detection.

Adolescent↗