Magnetic resonance imaging protocols for examination of the neurocranium at 3 T.

The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting.

Adult↗

Lung cancer screening with low-dose CT.

Screening for lung cancer is hoped to reduce mortality from this common tumour, which is characterised by a dismal overall survival, relatively well defined risk groups (mainly heavy cigarette smokers and workers exposed to asbestos) and a lack of early symptoms. In the past studies using sputum cytology and chest radiography have failed to demonstrate any reduction in lung cancer mortality through screening. One of the reasons is probably the relatively poor sensitivity of both these tests in early tumours. Low radiation dose computed tomography (CT) has been shown to have a much higher sensitivity for small pulmonary nodules, which are believed to be the most common presentation of early lung cancer. As, however, small pulmonary nodules are common and most are not malignant, non-invasive diagnostic algorithms are required to correctly classify the detected lesions and avoid invasive procedures in benign nodules. Nodule density, size and the demonstration of growth at follow-up have been shown to be useful in this respect and may in the future be supplemented by contrast-enhanced CT and positron emission tomography. Based on these diagnostic algorithms preliminary studies of low-dose CT in heavy smokers have demonstrated a high proportion of asymptomatic, early, resectable cancers with good survival. As, however, several biases could explain these findings in the absence of the ultimate goal of cancer screening, i.e. mortality reduction, most researchers believe that randomised controlled trials including several 10000 subjects are required to demonstrate a possible mortality reduction. Only then general recommendations to screen individuals at risk of lung cancer with low-dose CT should be made. It can be hoped that international cooperation will succeed in providing results as early as possible.

Humans↗

[Dose reduction of radiographs of the pediatric pelvis for diagnosing hip dysplasia using a digital flat-panel detector system].

PURPOSE: To evaluate a possible dose reduction in pediatric pelvic radiographs in congenital hip dysplasia using a digital flat-panel system instead of a phosphor-storage system. MATERIALS AND METHODS: During a six-month period, all pediatric patients referred for pelvic radiography for the evaluation of congenital hip dysplasia were randomly assigned to be examined by either a phosphor-storage system or a digital flat-panel system, whereby the latter system was operated with half the radiation dose. Thirty pairs of radiographs were assessed for the visibility of 16 anatomic details and for 5 orthopedic-radiographic measurements (5-point scale with 1 = excellent; three independent observers). The projection indices of Ball and Kommenda and of Tönnis and Brunken were calculated for all radiographs. The Student's t-test was used to compare the flat-panel and the phosphor-storage radiographs for observers' assessments, patients' age and projection indices. RESULTS: In a total of 7560 observations, the scores for the visibility of anatomic details and orthopedic-radiographic measurements were respectively 2.72 and 2.64 for the flat-panel system and 2.93 and 2.79 for the phosphor-storage system. No significant differences were found between both systems (p > 0.05) and between patient age and projection indices (p > 0.05). CONCLUSION: Pediatric pelvic radiographs can be obtained with a digital flat-panel system using half the radiation dose instead of a phosphor-storage system without sacrificing relevant information in the diagnosis of congenital hip dysplasia.

Age Factors↗

[Non-occlusive mesenteric ischemia].

The so-called non-occlusive disease (NOD) or non-occlusive mesenteric ischemia (NOMI) is a severe and life-threatening pathology. Even under optimal circumstances and standardised diagnostic and therapeutic procedures maximum survival rates do not exceed 50 %. The NOD is a pathology of the elder patient and its incidence rises with other comorbidities such as reduced cardiac output, diabetes and renal insufficiency. Induction of the disease with a severe vasoconstriction of the splanchnic vessels may be a simple cardiac decompensation, a frequent trigger however is a previous heart surgery with consecutive cardiac shock. Early diagnosis is difficult to conduct because of unspecific symptoms. Beside abdominal pain in awake patients, ileus or subileus is remaining the single acute symptom which could be also a consequence of a postoperative paralysis. Laboratory parameters such as leucocytosis and elevated lactat levels are often positive, but unspecific and the latter may be a delayed sign of progressive disease. The only sufficient method for diagnosis implicating a possible treatment option seems to be an immediate angiographic examination. Because of the disappointing results of a solitary surgical approach transarterial medication via catheter is indicated. Depending of the course of the disease only a combination of local mesenteric infusion of vasodilatory drugs and surgical resection of already necrotic bowel promises a successful therapeutic approach and better survival rates.

Abdominal Pain↗

[Prospective observation of abdominal ultrasound in radiological emergency services: approaches to cost saving].

PURPOSE: To analyze prospectively abdominal ultrasound in an emergency department (ED) with special emphasis on different routes of obtaining radiology service, reasons for consultation and ordering diagnosis, and to identify strategies for realizing cost savings. MATERIALS AND METHODS: Over a three-month period, the course of events of 295 patients, who entered the ED and underwent on-call sonography, was recorded from the initial presentation to the commencement of treatment, and the results were subsequently evaluated. RESULTS: Of all patients sonographically examined in the ED, 60 % had no prior contact to ambulatory medical services (self-referred, S), 15 % had been sent by a physician (physician-referred, P), and 25 % were inpatients. The most frequent reason for consultation was acute abdominal pain in self-referred patients (70 %) and blunt abdominal trauma in physician-referred patients (70 %). Sonography for acute abdominal pain was considered indicated by the examining radiologist prior to the examination in 90 % (P) and 70 % (S). Sonography contributed to the diagnosis in 44 % (P) and 22 % (S). Patients had to be hospitalized in 80 % (P) and 40 % (S), and needed immediate treatment in 78 % (P) and 43 % (S). Sonography after blunt abdominal trauma was considered appropriate in 90 % (P) and 65 % (S). Diagnostic information was obtained in 90 % (P) and 88 % (S), and therapeutic interventions were required in 10 % (P) and 0 % (S). The admission rate was 97 % (P) and 29 % (S), respectively. CONCLUSIONS: In the ED, sonography was performed with significantly lower clinical effectiveness on self-referred than on physician-referred patients. Substantial cost-savings could be achieved by more selective use of abdominal sonography for self-referred patients.

Abdomen↗

Pharmacokinetics of intra-arterial mitomycin C in the chemoembolization treatment of liver metastases with polyvinylalcohol or degradable starch microspheres.

OBJECTIVES: In cancer treatment, arterial blood flow reduction by embolization combined with intra-arterial chemotherapy may be advantageous by achieving high and prolonged drug concentrations in the tumor, and lower systemic drug exposure. The pharmacokinetics of intra-arterial mitomycin C (MMC) was investigated in patients with liver metastases undergoing chemoembolization treatment. METHODS: The chemoembolization treatment consisted of the use of polyvinylalcohol microspheres (ITC-Contour, diameter 150-250 micro m, irreversible vessel occlusion, 20 mg MMC, 15 patients) followed by sealing of the supplying artery with Ethibloc. Alternatively, starch microspheres (Spherex, diameter 45 micro m, biologically degradable, 10 ml of suspension containing 60 mg starch/ml, 20 mg MMC in 7 patients, 15 mg/m2 body surface in 3 patients) were used. MMC was infused over 6 min into the artery supplying the tumor. Serum MMC concentrations were determined from peripheral venous blood samples [protein precipitation with acetonitrile, reverse-phase HPLC with ultraviolet detection (C18 column, elution with 0.01 M, pH 6.5 phosphate buffer/methanol, v/v 70:30, 365 nm)]. The pharmacokinetic parameters were computed assuming an open two-compartment model and linear kinetics. RESULTS: The disposition parameters for MMC in patients treated with polyvinylalcohol microspheres were comparable to data from the literature (C(max)=913+/-98 ng/ml, T(max)=7.7+/-0.3 min, V(c)=0.27+/-0.03 l/kg, V(ss)=0.59+/-0.07 l/kg, Cl=757+/-67 ml/min, T(1/2 alpha)=5.8+/-0.8 min, T(1/2 beta)=50.4+/-4.1 min). There was no significant difference in the disposition parameters for MMC between patients treated with polyvinylalcohol microspheres and those treated with starch microspheres ( P>0.05). In particular, there was no significant difference in the standardized AUC between the groups; this implies that the systemic toxicity of MMC is comparable when polyvinylalcohol microspheres and ethibloc (AUC 1472+/-123 microg min/l per 1 mg MMC) or starch microspheres (AUC: 1448+/-172 microg min/l per 1 mg MMC) are used. CONCLUSION: The AUC values found in this study do not indicate a reduction in the systemic toxicity of MMC if applied intra-arterially in combination with embolizing microspheres, when compared to the AUC values in the literature for intra-arterial application without embolization, or intravenous MMC application. The amount of starch microspheres may have been too small to cause marked effects. On the other hand, there is a very wide range of AUC values reported in the literature for different application modes, and the use of such historical controls is not adequate for detecting more subtle advantages of the chemoembolization procedure, which may, however, exist.

Aged↗

Visualization of auditory habituation by fMRI.

The aim of this study was to measure and quantify habituation phenomena within the auditory cortex of 18 healthy subjects by means of fMRI. Auditory stimulation was done by digitally generated pulsed (nu = 5 Hz) 800-Hz sine tones with three alternating ON (duration 2 min) and OFF (1 min) periods. Binaural stimulation resulted in symmetrical bihemispheric activation of the auditory cortex. Our data revealed a characteristic signal decay to repeated acoustic stimulation: the response to the second was even more pronounced, and the third stimulation block significantly lower compared to the first. Thus, our data clearly demonstrate habituation phenomena, probably due to reduced neuronal activity with increased duration and/or frequency of stimuli.

Acoustic Stimulation↗

[Early lung cancer detection with low-dose CT: an update].

Lung cancer is the leading cause of death from malignancy. Due to a lack of early symptoms patients usually undergo therapy at advanced tumor stages when prognosis is poor. Feasibility studies of low-dose spiral CT screening of heavy smokers have shown that many small, resectable lung cancers can be diagnosed at early stages using simple diagnostic algorithms based on size and attenuation of detected pulmonary nodules with a small proportion of invasive procedures for benign lesions. Preliminary results of repeat screening confirms small size and favourable stage distribution of detected cancers, using even simpler diagnostic algorithms: additional diagnostic procedures are only required in new or growing nodules whereas follow-up with low-dose CT is sufficient in nodules that appear unchanged to exclude slow growth. However, mortality reduction by lung cancer screening with low-dose CT has yet to be demonstrated. Several randomised controlled trials are under way to assess possible mortality reduction by comparison of mortalities in a screening group and a control group. It is hoped that through international cooperation data from these trials can be pooled to allow for statistically significant conclusions as early as possible.

Aged↗

[Pulmonary aspergillosis as initial manifestation of septic granulomatosis (chronic granulomatous disease, CGD) in a premature monozygotic female twin and FDG-PET diagnosis of spread of the disease].

PURPOSE: To present the unusual case of chronic granulomatous disease (CGD) manifestating as pulmonal aspergillosis in female enzygotic twins during the neonatal period. To demonstrate and to discuss the complex diagnosis and the diagnostic value of FDG-PET in monitoring the spread and activity of the disease. PATIENTS: Plain chest x-ray and CT of the lung showed multiple, mostly round lesions in one of the former preterm twins at the age of 8 weeks. The girl with known ASD II was then suffering from dyspnoea and recurrent pulmonary infections. Because of the imaging findings invasive pulmonary aspergillosis due to an underlying immunodeficiency was suspected. RESULTS: Aspergillosis was confirmed histologically and microbiologically by specimens taken from an open lung biopsy. Because of coexisting granulocytic dysfunction the diagnosis of CGD was made. This diagnosis was equally confirmed by noninvasive methods in the asymptomatic sister. FDG-PET did not show any evidence of extra-pulmonary spread of disease. CONCLUSION: CGD can present as isolated pulmonal aspergillosis even in the neonatal period when an immunodeficiency is discussed. In enzygotic twins screening of the asymptomatic twin is mandatory. FDG-PET is a useful tool in screening for spread of the disease and in evaluating disease activity.

Age Factors↗

[The value of magnetic resonance imaging (MRI) for the follow-up of patients with transjugular intrahepatic portosystemic shunts (TIPS)].

PURPOSE: To prospectively determine the value of magnetic resonance imaging (MRI) with flow quantification in the portal vein for the follow-up of patients with transjugular intrahepatic portosystemic shunt (TIPS). METHODS: Thirty-six patients with TIPS (23 m, 13 f) were evaluated with MR of the liver parenchyma and quantification of flow in the portal vein. MR examinations were correlated with Doppler sonography and conventional angiography including measurement of the portal pressure gradient (PPG). In cases of re-interventions (dilatation/stent application) additional examinations with MRI and Doppler sonography were performed. RESULTS: MR flow measurements in the portal vein correlated with Doppler sonography (r = 0.69) whereas no correlation of both methods with the PPG was found. No threshold velocity in the portal vein could be determined to predict shunt stenosis. All shunt occlusions (n = 5) were diagnosed correctly by MRA. Thirty measurements before and after successful angiographic interventions revealed a significant increase in portal flow velocity and a significant decrease of the PPG. Magnetic resonance images enabled a reliable detection of procedural complications (parenchymal bleedings, n = 31; extra and subcaspular hematomas, n = 2 each) and newly occurring hepatocellular carcinomas (n = 2) in the follow-up period. CONCLUSION: Magnetic resonance imaging in the follow-up of TIPS enables a morphological assessment of the liver and an accurate velocity mapping, but is not suited to predict shunt dysfunction as a single method.

Aged↗

[Selenium-based digital radiography of the cervical spine: comparison with screen-film radiography for the depiction of anatomic details].

PURPOSE: To compare selenium-based digital radiography with conventional screen-film radiography of the cervical spine. MATERIALS AND METHODS: In a prospective study X-ray images of the cervical spine were obtained in 25 patients using selenium- based digital radiography and conventional screen-film radiography. All images were clinically indicated. Selenium-based digital radiography and conventional screen-film radiography were used in a randomized order. Four radiologists independently evaluated all 50 examinations for the visibility of 76 anatomic details according to a five-level confidence scale (1 = not visible, 5 = very good visibility). From the evaluation of these anatomic details scores for the upper and middle cervical spine, the cervicothoracic junction and the cervical soft tissues were calculated. The scores for selenium-based digital radiography and conventional screen-film radiography were compared using Wilcoxon's signed rank test. RESULTS: From a total of 15,200 observations (608 per patient) the following scores were calculated for selenium-based digital radiography and for screen-film radiography, respectively: Upper cervical spine 3.88 and 3.94; middle cervical spine 4.60 and 4.48; cervico-thoracic junction 3.64 and 2.62; cervical soft tissue 4.47 and 3.46. The differences between the last two scores were statistically significant (p < 0.05). CONCLUSION: The use of selenium-based digital radiography is superior to conventional screen-film radiography in the depiction of anatomic details of the cervicothoracic junction and the cervical soft tissues.

Cervical Vertebrae↗

Silicone breast implants: correlation between implant ruptures, magnetic resonance spectroscopically estimated silicone presence in the liver, antibody status and clinical symptoms.

OBJECTIVE: To determine the impact of implant integrity on clinical symptoms and antibody status in women with silicone breast implants (SBIs). METHODS: Ninety consecutive women were examined by means of magnetic resonance imaging (MRI) to assess the integrity of their silicone breast implants. The presence of silicone in the liver was estimated by (1)H localized stimulated echo acquisition mode (STEAM) magnetic resonance spectroscopy (MRS). Results were correlated with patients' complaints, as evaluated by a standardized questionnaire, physical examination by a rheumatologist and antibody screening. RESULTS: Breast MRI revealed defects in 24 patients (26.6%); in 13 (54.2%) of these women, silicone was detected in the liver by MRS. Of the 66 patients with MRI-estimated intact implants, 15 (22.7%) had apparent silicone in their liver, arguing for gel bleeding. Clinically, two patients had had rheumatoid arthritis before SBIs, whereas the other patients revealed no typical symptoms of arthritis or connective tissue disease (CTD). The patients with MRS evidence of silicone in the liver had no statistically significant differences in their complaints with the exception of the most frequent symptom, tingling/numbness of the fingers (82.1 vs 51.6%, P=0.006). A positive pattern of antinuclear antibodies (ANA) was obtained in 13 of the 28 MRS-positive patients (46.4%) and in 15 of the 62 MRS-negative patients (24.2%, P=0.033). However, in only one of these 28 ANA-positive patients was a specific weak antibody titre against SS-A detected by ELISA. CONCLUSION: Implant integrity has no major impact on rheumatic symptoms of women with SBIs. This finding supports the standpoint that silicone does not cause either a specific CTD or any other distinct disease entity. However, the moderately increased incidences of ANA-positivity and neuropathy-associated symptoms require explanation.

Adult↗