PubMed Health⌕ Search

Biomedical subjects

W Husinsky

Publications and source records attributed to W Husinsky.

14 recordsLinked to original sources

Dynamics of laser desorption and ablation of metals at the threshold on the femtosecond time scale

The dynamics of the laser-ablation (-desorption) process of metals (Al, Ag, Fe, and Ni) initiated by 30 fs laser pulses has been investigated by interferometric time-resolved pump-probe measurements. It is postulated that a sufficiently high density of hot electrons is essential for achieving desorption of metal ions. In addition, we have observed a new and unexpected behavior characterized by delayed ablation for a pump-probe beam delay in the range of several ps for Al, Ni, and Fe. This second peak is attributed to the development of a liquid surface layer developing after a few ps. Molecular dynamics simulations support this assumption.

Journal Article↗

Laser shaping of corneal transplants in vitro: area ablation with small overlapping laser spots produced by a pulsed scanning laser beam using an optimizing ablation algorithm.

Area laser lathing and trephination of donor corneas is used to produce different types of grafts for human transplantation. 193 nm (ArF excimer) laser radiation is used, since this is known to give a non-thermal laser-tissue interaction with a minimal zone of tissue damage. To guarantee the highest degree of flexibility concerning the overall shape of the grafts as well as their thickness profiles, we use a small (compared with the area to be ablated) scanning laser spot. For area lathing of the tissue we have developed a new ablation algorithm (optimized scanning laser ablation, OSLA) that can be applied to lathe and perforate any tissue--with concave (as in this application), convex or plane surface geometry--where surface precision and smoothness are key issues. Using OSLA with the Excimer Laser Corneal Shaping System (a tool for in vitro fabrication of all kinds of corneal transplants like donor buttons for keratoplasty, lamellar grafts for epikeratoplasty and refractive lenticules) enabled us to produce all types of corneal grafts with very high precision. This is considered to be a major improvement towards the production of refractive lenticules.

Algorithms↗

Endothelialization of biosynthetic vascular prostheses after laser perforation.

OBJECTIVE: This study was undertaken to investigate the feasibility of transmural capillary ingrowth into the inner surface of biosynthetic vascular prostheses (Omniflow, BioNova, Melbourne, Australia) through perforations created by an excimer laser, thus inducing an endothelial cell coverage. METHOD: Biosynthetic vascular prostheses (Omniflow, 10 cm length, 6 mm diameter) were perforated with an excimer laser (diameter of the holes 50 to 100 microm, distance 4 mm) and implanted into the carotid arteries of eight sheep. They were compared to untreated Omniflow prostheses implanted at the contralateral side. Three months after implantation the prostheses were explanted and evaluated by gross morphology, histologic examination, scanning electron microscopy, and immunohistochemical staining for factor VIII to identify endothelial cells. RESULTS: All grafts remained patent. Gross morphologic examination revealed no significant difference in the thrombus-free surface between perforated and untreated prostheses. However, scanning electron microscopy showed endothelial cells in the midgraft portion of all perforated prostheses, whereas collagen fibers, fibrin meshwork, and activated platelets formed the inner layer in six of eight untreated Omniflow prostheses. Transmural capillary ingrowth in the laser group was verified by positive factor VIII staining for endothelial cells in the laser channels. CONCLUSION: Spontaneous endothelialization of biosynthetic vascular prostheses can be achieved by transmural capillary ingrowth through perforations in the wall of the prostheses in an experimental sheep model.

Anastomosis, Surgical↗

Corneal lathing using the excimer laser and a computer-controlled positioning system.

PURPOSE: To present the excimer laser corneal shaping system (ELCS-S), an add-on device to the Keratom, a commercially available 193-nm excimer laser built by Schwind. METHODS: The system is designed for the preparation of donor corneas under sterile conditions using the ultraviolet laser to offer greatest possible flexibility. Lenticules for planolamellar grafting and refractive epikeratoplasty, as well as donor buttons for penetrating keratoplasty can be computer-designed by the surgeon or technician and lathed with the system. RESULTS: Using the excimer laser corneal shaping system (ELCS-S) on human donor corneas, the central surface of the epikeratoplasty lenticule exhibited only narrow, flat concentric notches corresponding to the single lathing steps. Transmission electron microscopy revealed a damage zone of less than 0.3 microm in close approximation to the treated surface. The final thickness revealed a difference of less than +/-53 microm from the intended, initially programmed value. Ultrastructural studies showed the perpendicular stromal surface of the penetrating keratoplasty buttons to be smooth with minimal protrusion of Descemet's membrane. Endothelial injury was observed in a zone averaging between 40 and 100 microm adjacent to the cutting edge only. CONCLUSION: The excimer laser corneal shaping system (ELCS-S) allows a computer-controlled, surgeon-designed, sterile preparation of lamellar and penetrating corneal grafts with the use of the excimer laser. This could offer significant advantages in comparison to presently available systems for lamellar dissection and trephination.

Computers↗

Corneal lathing using the excimer laser and a computer-controlled positioning system: Part I--Lathing of epikeratoplasty lenticules.

Precise lathing of epikeratoplasty lenticules is difficult to achieve with the cryolathe due to unpredictable expansion of the lathing tools and the corneal tissue during the freezing process. In addition, the procedure destroys all viable cells in the transplant thereby possibly contributing to the prolonged period of visual rehabilitation. Non-freezing techniques using the microkeratome or the rotor-trephine, on the other hand, are technically demanding, can cause mechanical damage during cutting or fixation, and, have not given consistently reproducible refractive results. A new system is presented that allows a variable laser ablation of donor corneas into lenticules for aphakic and myopic epikeratoplasty, as well as for lamellar keratoplasty. With the help of a computer-controlled positioning system that uses high-precision micropositioning elements (both translation and rotational stages) the donor cornea is moved, epithelial side down, in a holding device in front of a focused excimer laser beam (ArF, lambda = 193 nm). This photoablation lathing process assures the viability of the stromal cells in the lenticule in close approximation to the treated surface. The user friendly computer software allows the fast and convenient selection of a variety of parameters, such as the diameter of the optical zone, the shape of the wing zone, the refractive power, the central thickness of the lenticule and the overall contour of the transplant. The first laboratory data of lenticules prepared from human corneas with this "Excimer Laser Corneal Shaping System" are presented.

Cornea↗

Corneal lathing using the excimer laser and a computer-controlled positioning system: Part II--Variable trephination of corneal buttons.

A new system is presented that allows a variable trephination of donor corneas for the preparation of corneal buttons used in penetrating keratoplasty. With the help of a computer-controlled positioning system that uses high-precision micropositioning elements (both translation and rotational stages) the donor cornea is removed, epithelial side up, in a fixation device in front of a focused excimer laser beam (ArF, lambda = 193 nm). User friendly computer software allows the surgeon to select a variety of parameters (diameter, shape, angle of trephination) of the corneal graft. Histological and electron microscopical data of human corneas trephined with this "Excimer Laser Corneal Shaping System" are presented.

Cornea↗