PubMed Health⌕ Search

Biomedical subjects

W I Bensinger

Publications and source records attributed to W I Bensinger.

141 records · Page 8Linked to original sources

Clinical trials with staphylococcal protein A.

Several reports have indicated antitumor effects from the immunoadsorption of plasma from tumor-bearing animals and humans with protein A-containing Staphylococcus aureus. The columns used for these treatments have varied widely in design. In a Phase I trial at the University of Washington, we used protein A chemically linked to crystalline silica for continuous immunoadsorption of plasma in 20 patients with advanced malignancies. Separated blood was perfused continuously over columns containing 50-100 g of immunoadsorbent with 100-200 mg protein A. One calculated plasma volume was perfused over the columns for each treatment. Patients received between 1 and 22 treatments, in total, at one to three treatments per week. Two patients had in vitro treatment of plasma separated from a unit of whole blood obtained by phlebotomy. Side effects were common, were usually manageable, and included chills and fever, nausea, tumor pain, hypotension, and respiratory symptoms. The observed antitumor responses were modest. Three of seven patients with melanoma had indications of responses less than 50%. One of three patients with breast cancer had a response less than 50%. The above studies demonstrate the feasibility of using staphylococcal protein A immunoadsorption in a larger group of patients with a more favorable disease stage.

Drug Evaluation↗

Marrow harvesting from normal donors.

The experience at a single institution in harvesting marrow for allogeneic transplantation on 1,270 occasions from 1,160 normal donors is presented in detail, together with an analysis of all the donor complications. Four donors were less than 2 years old, and the youngest was 6 1/2 months. No special difficulties were encountered with these young donors. Hospitalization time was three days or less for 99% of the procedures. Six donors had life-threatening complications; three of a cardiopulmonary and two of an infectious nature, and one cerebrovascular embolic episode. Significant operative site morbidity, usually transient neuropathies, occurred in ten procedures. Ten percent of the donations were associated with transient postoperative fever of unknown origin. Increasing donor age was associated with a reduction of the cellularity of the marrow harvest. The use of stored autologous blood permitted the avoidance of blood bank transfusion in 81% of males, 69% of females, and 50% of children. It was concluded that the procedure was associated with a very low risk of complication, but that the involvement of normal donors in such an operation justifies stringent monitoring.

Adolescent↗

Removal of specific antibody in vivo by whole blood immunoadsorption: preliminary results in dogs.

Effective immunoadsorption for removal of anti-red cell antibodies from plasma using affinity columns has been demonstrated. However, the requirement of a continuous-flow centrifuge to separate plasma increases the cost and complexity of the procedure. We have adapted red cell antigen immunoadsorption columns for use with whole blood. Effective and specific removal of anti-red cell antibodies was achieved in actively immunized dogs.

ABO Blood-Group System↗

ABO-incompatible marrow transplants.

We analyzed data from 81 ABO-incompatible marrow transplants performed between 1972 and 1980. Patients with high anti-red blood cell antibody levels pretransplant had a significantly increased probability of antibody return post-transplant. This was true for IgG and for IgM as independent variables. However, the return of antibody post-transplant had no effect on engraftment, survival, or blood product requirements posttransplant. Patients who received ABO-incompatible marrow had a similar time to engraftment, survival, and incidence of rejection and graft-versus-host disease as patients receiving ABo-compatible transplants. Neither pretransplant treatment regimen nor the development of graft-versus-host disease had an effect on post-transplant antibody levels. ABO-incompatible marrow transplants can be performed with no greater morbidity or mortality than ABO-compatible grafts. The procedures for antibody removal may be useful in other organ transplant settings.

ABO Blood-Group System↗

Immune adsorption of anti-A and anti-B antibodies.

Plasma exchange is an effective technique for removal of antibodies prior to ABO incompatible marrow grafting. However, expense and hepatitis risk make alternative methods desirable. A solid phase immunoadsorbent column using blood group A trisaccharide has been demonstrated to specifically remove anti-A antibody from human plasma in vitro and immunized dogs in vivo with no toxicity. Preliminary results in patients are encouraging.

ABO Blood-Group System↗

Inhibition of rat adenocarcinoma metastases by "Staphylococcus aureus" protein A.

Fischer F 344/CRBL female rats were injected intravenously with 10(6) syngeneic 13,762 adenocarcinoma cells, and daily doses of either 10 micrograms, 100 micrograms or 1 mg Staphylococcus aureus protein A were administered intraperitoneally on days 1 through 11. The animals were sacrificed on day 12, their lungs infused with Bouin's solution, and lung metastases counted. A significant reduction in the number of visible metastatic nodules was observed in the animals given 100 micrograms and 1 mg of Staphylococcus aureus protein A daily.

Adenocarcinoma↗

Plasma exchange and immunoadsorption for removal of antibodies prior to ABO incompatible bone marrow transplant.

ABO incompatible allogeneic bone marrow transplants can be performed successfully to treat patients with leukemia or aplastic anemia. These transplants carry no great risk of rejection or graft-versus-host disease, however, some method must be used to avoid acute hemolysis at the time of infusion of ABO incompatible marrow. We have used successfully large volume plasma exchange to remove anti-A or anti-B antibodies prior to marrow infusion. More recently we have used immunoadsorbent columns containing synthetic A or B antigen specifically to remove anti-A or anti-B antibodies in lieu of plasma exchange. These columns are better tolerated than plasma exchange where allergic reactions are common.

ABO Blood-Group System↗

Laminar air flow isolation and decontamination: a prospective randomized study of the effects of prophylactic systemic antibiotics in bone marrow transplant patients.

122 patients with hematologic malignancies underwent allogeneic marrow transplantation from HLA-matched sibling donors and received one of two forms of infection prophylaxis while granulocytopenic: 1) decontamination and laminar air flow isolation (LAF, 68 patients), and 2) LAF plus prophylactic systemic antibiotics (LAF + PSA, 54 patients). Patients were evaluated for infection acquisition while in isolation. Septicemia occurred in 11 (16%) of the patients in the LAF group and in three (6%) patients in the LAF + PSA group. Fourteen (21%) of the patients in the LAF group and four (7%) patients in the LAF + PSA group had a major local infection. There was no difference in the incidence and severity of graft-versus-host disease or incidence and duration of fever. The addition of prophylactic intravenous broad-spectrum antibiotics for patients isolated in LAF rooms significantly decreased infection acquisition.

Adolescent↗

In vitro and in vivo removal of anti-A erythrocyte antibody by adsorption to a synthetic immunoadsorbent.

A solid-phase immunoadsorbent column using blood group A trisaccharide was tested in vitro and in vivo in dogs. This column was demonstrated to specifically remove anti-A antibody from human plasma in vitro and in vivo dogs specifically immunized with synthetic human blood group A trisaccharide. These studies indicate that this technique will be useful in removing anti-A and B antibody in marrow transplant recipients of incompatible marrow.

ABO Blood-Group System↗

The effect of blood cooling prior to granulocyte collection.

A study was designed to test the hypothesis that cooling blood before it enters a continuous-flow blood cell separator would result in increased granulocyte yields. Fifty-four granulocyte collections performed with cooling were compared with 58 collections performed on alternate days in the same donors. In blood cooled to 15 degrees C we were unable to demonstrate improved yields of granulocytes.

Blood↗

Collection of peripheral blood progenitor cells with an automated leukapheresis system.

BACKGROUND: Apheresis devices designed for the collection of mature blood elements are being used for the collection of peripheral blood progenitor cells (PBPCs). The collection of PBPCs differs from that of other cells in the rarity of the target cell and in the fact that donors may undergo several days of collection. A consequence of this process may be a depletion of blood cells such as platelets from the blood. The disposable set and operating software for an apheresis device (Spectra, COBE BCT) was modified by the manufacturer to automate the collection of PBPCs and reduce the collection of unwanted blood cells. STUDY DESIGN AND METHODS: A study was initiated to compare the collection of PBPCs with the new device, the AutoPBSC (version [V]6.0 with AutoPBSC tubing set), and that with the MNC (mononuclear cell) procedure (V4.7 with white cell tubing set), for patients and healthy donors. RESULTS: Patients whose blood was processed by either theV6.0 orV4.7 procedure achieved the target dose of 5 x 10(6) CD34+ cells per kg of patient weight in similar numbers of procedures, even though the calculated collection efficiency for CD34+ cells using the automated V6.0 procedure was significantly less than that with the V4.7 procedure for both allogeneic donors and patients donating PBPCs. The collection efficiency for platelets was lower with the V6.0 procedure, and components collected in this manner contained fewer platelets. Apheresis by the V6.0 procedure required 30 to 60 more minutes per procedure than apheresis by the V4.7 procedure. Review of engraftment kinetics after transplantation did not reveal any effect of the collection procedure on recipients of either allogeneic or autologous transplants. CONCLUSION: The collection efficiencies of the V6.0 procedure for both CD34+ cells and mature blood cells are lower than those of the V4.7 procedure. The lower collection efficiency for platelets results in a smaller drop in peripheral blood platelet count after the procedure. The automated features of the V6.0 procedure may simplify PBPC collection, but this procedure requires a longer apheresis.

Adult↗