PubMed Health⌕ Search

Biomedical subjects

W Ingram

Publications and source records attributed to W Ingram.

8 recordsLinked to original sources

Getting the measure of spasticity in multiple sclerosis: the Multiple Sclerosis Spasticity Scale (MSSS-88).

Spasticity is most commonly defined as an inappropriate, velocity dependent, increase in muscle tonic stretch reflexes, due to the amplified reactivity of motor segments to sensory input. It forms one component of the upper motor neuron syndrome and often leads to muscle stiffness and disability. Spasticity can, therefore, be measured through electrophysiological, biomechanical and clinical evaluation, the last most commonly using the Ashworth scale. None of these techniques incorporate the patient experience of spasticity, nor how it affects people's daily lives. Consequently, we set out to construct a rating scale to quantify the perspectives of the impact of spasticity on people with multiple sclerosis. Qualitative methods (in-depth patient interviews and focus groups, expert opinion and literature review) were used to develop a conceptual framework of spasticity impact, and to generate a pool of items with the potential to convert this framework into a rating scale with multiple dimensions. This item pool was administered, in the form of a questionnaire, to a sample of people with multiple sclerosis and spasticity. Guided by Rasch analysis, we constructed and validated a rating scale for each component of the conceptual framework. Decisions regarding item selection were based on the integration and assimilation of seven specific analyses including clinical meaning, ordering of thresholds, fit statistics and differential item functioning. The qualitative phase (17 patient interviews, 3 focus groups) generated 144 potential scale items and a conceptual model with eight components addressing symptoms (muscle stiffness, pain and discomfort and muscle spasms,), physical impact (activities of daily living, walking and body movements) and psychosocial impact (emotional health, social functioning). The first postal survey was sent to 272 people with multiple sclerosis and had a response rate of 88%. Findings supported the development of scales for each component but demonstrated that five item response options were too many. The 144-item questionnaire, reformatted with four-item response options, was administered with four validating instruments to an independent sample of 259 people with multiple sclerosis (response rate 78%). From the responses, an 88-item instrument with eight subscales was developed that satisfied criteria for reliable and valid measurement. Correlations with other measures were consistent with predictions. The 88-item Multiple Sclerosis Spasticity Scale (MSSS-88) is a reliable and valid, patient-based, interval-level measure of the impact of spasticity in multiple sclerosis. It has the potential to advance outcomes measurement in clinical trials and clinical practice, and provides a new perspective in the clinical evaluation of spasticity.

Activities of Daily Living↗

Two-nucleon momentum distributions measured in 3He(e,e'pp)n.

We have measured the 3He(e,e'pp)n reaction at 2.2 GeV over a wide kinematic range. The kinetic energy distribution for "fast" nucleons (p>250 MeV/c) peaks where two nucleons each have 20% or less, and the third nucleon has most of the transferred energy. These fast pp and pn pairs are back to back with little momentum along the three-momentum transfer, indicating that they are spectators. Calculations by Sargsian and by Laget also indicate that we have measured distorted two-nucleon momentum distributions by striking one nucleon and detecting the spectator correlated pair.

Journal Article↗

The role of surgeon-performed ultrasound in patients with possible cardiac wounds.

OBJECTIVE: The authors evaluate surgeon-performed ultrasound in determining the need for operation in patients with possible cardiac wounds. BACKGROUND DATA: Ultrasound quickly is becoming part of the surgeon's diagnostic armamentarium; however, its role for the patient with penetrating injury is less well-defined. Although accurate for the detection of hemopericardium, the lack of immediate availability of the cardiologist to perform the test may delay the diagnosis, adversely affecting patient outcome. To be an effective diagnostic test in trauma centers, ultrasound must be immediately available in the resuscitation area and performed and interpreted by surgeons. METHODS: Surgeons performed pericardial ultrasound examinations on patients with penetrating truncal wounds but no immediate indication for operation. The subcostal view detected hemopericardium, and patients with positive examinations underwent immediate operation by the same surgeon. Vital signs, base deficit, time from examination to operation, operative findings, treatment, and outcome were recorded. RESULTS: During 13 months, 247 patients had surgeon-performed ultrasound. There were 236 true-negative and 10 true-positive results, and no false-negative or false-positive results; however, the pericardial region could not be visualized in one patient. Sensitivity, specificity, and accuracy were 100%; mean examination time was 0.8 minute (246 patients). Of the ten true-positive examinations, three were hypotensive. The mean time (8 patients) from ultrasound to operation was 12.1 minutes; all survived. Operative findings (site of cardiac wounds) were: left ventricle (4), right ventricle (3), right atrium (2), right atrium/superior vena cava (1), and right atrium/inferior vena cava (1). CONCLUSIONS: Surgeon-performed ultrasound is a rapid and accurate technique for diagnosing hemopericardium. Delay times from admission to operating room are minimized when the surgeon performs the ultrasound examination.

Adolescent↗

Computer-assisted antibiotic use review.

The use of a computer system for an antibiotic review program is described. A commercial system was selected as the software base for the development of the antibiotic use review (AUR) program. The AUR system is composed of three parts: (1) editing and verifying data from the patient's pharmacy profile card, (2) updating the data base, and (3) generation of reports. The system is flexible in its reporting capabilities. Potential functions of the system include identifying patterns of bacterial resistance. The computer system is an efficient tool for the clinical review of antibiotic use in a quality assurance program.

Anti-Bacterial Agents↗

The evolution of a functional real-time laboratory records retrieval and archival system.

The vast flood of information resulting from medical record keeping in a clinical laboratory must be cataloged and archived. To deal with this problem we designed an approach employing automated report generation by a laboratory computer, data base management of patient laboratory results, and automated microform generation via computer output microform (COM). This paper documents the steps that led to the system we are currently employing. The system described maintains the availability of current patient laboratory data, creates a microform archive and an on-line index, and serves as the data base for research inquiries. In addition, we have experienced a cost savings over manual procedures and now possess the capability of expansion without the costly addition of personnel.

Archives↗