PubMed Health⌕ Search

Biomedical subjects

W J Castellani

Publications and source records attributed to W J Castellani.

12 recordsLinked to original sources

Plasmacytoma of the ovary: a case report and literature review.

BACKGROUND: Ovarian plasmacytomas are a unique and unusual presentation of extramedullary plasmacytomas (EMP). A report of the seventh such case is presented with review of the previous six cases. METHODS: Surgical and medical staging were performed on the present case. The literature is reviewed. RESULTS: EMP involving the ovary is usually large at the time of presentation, more likely involving the left side, and without evidence of disseminated disease. As in other plasma cell dyscrasia, IgG paraprotein is more frequently involved. CONCLUSION: Adjuvant treatment for ovarian plasmacytomas is not clearly established; however, if complete surgical resection is achieved and no evidence of multiple myeloma is found, observation should be strongly considered.

Female↗

Inability of serum myocyte death markers to predict acute cardiac allograft rejection.

Acute cardiac rejection involves myocyte necrosis. Hence, markers of myocyte death may be useful in diagnosing rejection. Creatine kinase MB, MB isoforms, and troponins I and T were measured in 186 patients undergoing 365 endomyocardial biopsies. No differences were noted with rejection (rejectors vs. nonrejectors: CK=63.8 U/L and 86.6 U/L, P=0.0881; CK MB=2.04 ng/ml and 2.06 ng/ml, P=0.949; troponin T=0.134 ng/ml and 0.0881 ng/ml, P=0.374; troponin I=0.216 ng/ml and 0.707 ng/ml, P=0.357). The time course of troponins T and I levels in rejectors and nonrejectors do not differ with both groups having early elevations. Markers of myocyte death are inadequate predictors of acute rejection in cardiac allografts. The time course of troponins T and I suggests a possible role as prognostic indicators of outcome.

Acute Disease↗

Monoethylglycinexylidide formation as an independent measure of warm hepatic ischemia and reperfusion injury.

An accurate serologic measure of hepatic function would be clinically useful in selecting donors for liver transplantation. An experimental model that incorporates varying lengths of total hepatic warm ischemia with reperfusion injury was utilized to compare serologic parameters and mitochondrial performance of oxidative phosphorylation in predicting hepatocellular injury. Monoethylglycinexylidide (MEGX) formation following bolus intravenous lidocaine injection was found to be significantly decreased (P < 0.0001) at all periods of ischemia when compared to that in nonischemic controls. A serum MEGX level of < 50 micrograms/liter suggested severe hepatic damage. No correlation was found between MEGX level and liver viability as measured by animal survival. Serum transaminase (AST and ALT) levels demonstrated progressive, nonsignificant elevations with increasing length of ischemia (P = 0.0779 at the maximum ischemic time). Polarographic measurements of mitochondrial oxidative phosphorylation did not reveal a significant alteration in subcellular metabolism with prolonged ischemic time. These data highlight the comparative sensitivity of MEGX formation as an early quantitative measurement of hepatocellular injury during warm ischemia, although it was not predictive of organ viability.

Adenosine Triphosphate↗

The effect of lysed platelets on neutralization of heparin in vitro with protamine as measured by the activated coagulation time (ACT)

The effect of lysed platelets on the activated coagulation time (ACT) was studied in heparinized whole blood during titration with protamine. Frozen-thawed washed platelet suspension, or a chromatography fraction thereof, or autologous frozen-thawed platelet-rich plasma was added in various dilutions to freshly drawn blood anticoagulated with 3,000 USP units/l heparin. After a 10 min incubation, the amount of protamine needed to restore the ACT to baseline ("protamine titration dose") was determined. We found that the protamine titration dose decreased in proportion to the amount of lysed platelet material added; expressed as a percentage of the total number of platelets present, each unit increase in lysed platelets produced a 1.7% +/- 0.8 (SD) reduction in the protamine dose needed to normalize the ACT. A heparin activity assay showed that this effect was not due to anti-heparin activity of lysed platelets such as platelet factor 4 (PF4). Our data indicate that the procoagulant activity of platelet membranes reduced the sensitivity of the ACT to heparin. These findings suggest that membranous platelet microparticles may cause an inaccurate calculation, based on the ACT, of a protamine dose to reverse heparin anticoagulation in cardiopulmonary bypass procedures.

Blood Platelets↗

Effect of reticulocytosis on lactate dehydrogenase isoenzyme distribution in serum: in vivo and in vitro studies.

We investigated the effect of reticulocytosis on the lactate dehydrogenase (LD; EC 1.1.1.27) isoenzyme LD1/LD2 ratio in patients with and without evidence of hemolytic disease. Analysis of sera from patients with reticulocytosis and in vivo hemolysis showed a mean LD1/LD2 ratio of 0.92 compared with a ratio of 0.69 in patients with in vivo hemolysis and normal reticulocyte counts. Determination of LD isoenzymes in erythrocyte lysate revealed significantly increased LD1/LD2 ratios for patients with marked reticulocytosis compared with those for patients with normal-to-minimal increases in reticulocytes. Finally, separation of mature erythrocytes and reticulocytes by flow cytometry revealed marked differences in the LD1/LD2 isoenzyme distribution between these two cell types. The ability of hemolysis to cause a "flipped" LD1/LD2 ratio is dependent on the proportion of the hemolyzed cells that are reticulocytes.

Cells, Cultured↗

Plasmin activity and complement activation during storage of citrated platelet concentrates.

Platelet concentrates were studied for evidence of plasmin activity and complement activation during a 7-to-10-day storage period. When measured by an amidolytic activity assay, plasmin reached a level of 845 +/- 540 nkats/L on day 7 (n = 9). Fibrin(ogen) degradation product (FDP) levels became markedly elevated on the tenth day of storage, rising to 45 +/- 22 micrograms/ml (n = 5). Antiplasmin levels decreased in platelet concentrates by 18% +/- 6% (n = 5) over 7 days, but there was no significant decrease in stored platelet-poor plasma (-1.7%, n = 5, p = 0.5). The amount of plasminogen in platelet concentrate converted to plasmin was estimated to be less than 3% by assay of total plasminogen. Supernatant plasma from stored platelet concentrates was examined for the presence of the complement activation peptides C3a and C5a. From day 0 to day 10 of storage, mean C3a levels rose from 327 ng/ml to 6690 ng/ml. An equivalent increase in C3a levels, from 336 ng/ml at day 0 to 6866 ng/ml at day 10, was also observed in stored platelet-poor plasma. C5a was not detected (less than 10 ng/ml) at any point during the storage period; however, we noted a small decrease of borderline significance (p = 0.04) in total C5 from day 0 (117 micrograms/ml) to day 10 (108 micrograms/ml). Only trace amounts of C3 fragments were found on stored platelets, and there was no evidence of the membrane attack complex. These findings indicate the presence of plasmin activity and conversion of C3 during storage of platelet concentrates.

Blood Platelets↗

Robotic sample preparation evaluated for the immunochemical determination of cardiac isoenzymes.

A general-purpose bench-top laboratory robot was programmed to perform sample preparation for immunoprecipitative and immunoinhibitory determinations of cardiac isoenzymes with commercial kits. Run size could be varied from 1 to 24 patients' samples, and was determined by the robot without prompting. The robot placed the processed samples into a sample rotor for dried transfer to a batch centrifugal analyzer. Robotic precision compared well with that of manual performance of the same procedures at four concentrations of lactate dehydrogenase (EC 1.1.1.27) isoenzyme 1 activity and at one of two concentrations of creatine kinase (EC 2.7.3.2.) isoenzyme MB activity; for the other creatine kinase MB concentration, use of the robot significantly improved precision. Results for 100 samples from patients after open-heart surgery were highly correlated with manually obtained results for both isoenzyme determinations (r less that 0.96 each). Time to completion for small run sizes for either approach was comparable about 25 min. For larger batches, robotic run time increased rapidly, to 169 min for 24 patients' samples vs 41 min by manual assay.

Autoanalysis↗