PubMed Health⌕ Search

Biomedical subjects

W J Earwaker

Publications and source records attributed to W J Earwaker.

7 recordsLinked to original sources

Custom cranioplasty using stereolithography and acrylic.

Numerous methods of cranioplasty have been described. Customization and prefabrication have been reported to reduce operating time and improve cosmesis. An original technique for the manufacture of customized cranioplastic implants has been developed and tested in 30 patients.Thirty patients requiring cranioplasties were selected. Data acquired from computed tomography (CT) were used to manufacture exact plastic replicas (biomodels) of craniotomy defects and master cranioplastic implants using the rapid prototyping technology of stereolithography (SL). The three-dimensional (3D) imaging techniques of mirroring and interpolation were used to extrapolate on existing anatomy to design the master implants. The master implants were hand finished to fit the defect in the corresponding cranial biomodel exactly and were then used to create a cavity mould. The mould was used to cast thermally polymerised custom acrylic implants. The surgeons reported that the customized implants reduced operating time, afforded excellent cosmesis and were cost effective. The patients reported that the opportunity to see the biomodel and implant preoperatively improved their understanding of the procedure. Two complications were noted, one infection and one implant required significant trimming. The simultaneous manufacture of the master implant (male) and biomodel (female) components from SL allowed custom accurate implants to be manufactured. Disadvantages identified were the time required for computer manipulations of the CT data (up to 2 h), difficulty in assessing the accuracy of the computer generated master as a 3D rendering, the potential for SL parts to warp, manufacturing time (minimum 2 days) and the cost of approximately $1300 US per case ($1000 for the SL biomodel and $300 for the acrylic casting).

Humans↗

Cerebrovascular biomodelling: a technical note.

BACKGROUND: Recently computed tomographic angiography (CTA) and MR angiography (MRA) have been used to image cerebrovascular structures. Although CTA and MRA are accurate and sensitive imaging modalities, limitations have been identified in relation to image interpretation. Stereolithographic (SL) biomodelling is a new technology that allows three-dimensional (3D) CT and MR data to be used to accurately manufacture solid plastic replicas of anatomical structures. A prospective trial of SL biomodelling in cerebrovascular surgery has been performed to investigate the feasibility and clinical utility of this new display medium. METHODS: Fifteen patients with cerebral aneurysms and 1 patient with a cerebral arteriovenous malformation (AVM) were selected. 3D CT and/or MR angiograms were acquired and 19 solid anatomical biomodels manufactured using the rapid prototyping technology of stereolithography. The biomodels were used for patient education, diagnosis, operative planning and surgical navigation. RESULTS: The biomodels replicated the CTA and MRA source data. The accuracy of one biomodel was verified by comparison with a post mortem specimen, which corresponded exactly in the x and y planes but differed by 2 mm in the z plane. The ability to closely study an overview of complex cerebrovascular anatomy from any perspective on a solid biomodel was reported to enhance the surgeon's understanding, particularly when conventional images were equivocal. Cerebrovascular biomodels were found to be useful when positioning the patient's head for surgery, for selecting the best aneurysm clip and for the simulation of clipping. Patient informed consent was anecdotally improved. Disadvantages of the technology were the cost and manufacturing time. CONCLUSIONS: Cerebrovascular biomodelling may have utility in complex cases or when the standard imaging is felt to be equivocal.

Adult↗

Stereolithographic biomodelling in cranio-maxillofacial surgery: a prospective trial.

Stereolithographic (SL) biomodelling is a new technology that allows three-dimensional (3-D) computed tomography (CT) data to be used to manufacture solid plastic replicas of anatomical structures (biomodels). A prospective trial with the objective of assessing the utility of biomodelling in complex surgery has been performed. Forty-five patients with craniofacial, maxillofacial, skull base cervical spinal pathology were selected. 3-D CT or MR scanning was performed and the data of interest were edited and converted into a form acceptable to the rapid prototyping technology SL. The data were used to guide a laser to selectively polymerize photosensitive resin to manufacture biomodels. The biomodels were used by surgeons for patient education, diagnosis and operative planning. An assessment protocol was used to test the hypothesis that 'biomodels in addition to standard imaging had greater utility in the surgery performed than the standard imaging alone'. Biomodels significantly improved operative planning (images 44.09%, images with biomodel 82.21%, P < .01) and diagnosis (images 65.63%, images with biomodel 95.23%, P < .01). Biomodels were found to improve measurement accuracy significantly (image measurement error 44.14%, biomodel measurement error 7.91%, P < .05). Surgeons estimated that the use of biomodels reduced operating time by a mean of 17.63% and were cost effective at a mean price of $1031 AUS. Patients found the biomodels to be helpful for informed consent (images 63.53%, biomodels 88.54%, P < .001). Biomodelling is an intuitive, user-friendly technology that facilitated diagnosis and operative planning. Biomodels allowed surgeons to rehearse procedures readily and improved communication between colleagues and patients.

Cephalometry↗

Stereolithographic (SL) biomodelling in craniofacial surgery.

BACKGROUND: Stereolithographic (SL) biomodelling allows 3D CT to be used to generate solid plastic replicas of anatomical structures (biomodels). Case reports in the literature suggest that such biomodels may have a use in craniofacial surgery but no large series or assessment of utility has been reported. A prospective trial to assess the utility of biomodelling in craniofacial surgery has been performed. METHODS: Forty patients with complex craniofacial abnormalities were selected and 3D CT scanning performed. The data of interest was used to guide a laser to selectively polymerise photosensitive resin to manufacture SL biomodels. The biomodels were used for patient education, diagnosis and operative planning. An assessment protocol was designed to test the hypothesis that biomodels in addition to standard imaging had greater utility in the surgery performed than the standard imaging alone. RESULTS: Anecdotally surgeons found biomodelling useful in 40 complex craniofacial operations. The formal assessment of the first 10 cases suggested biomodels improved operative planning (image 76%, image with biomodel 97%, P < 0.01) and diagnosis (image 82.5%, image with biomodel 99.25%, P < 0.01). Surgeons estimated that the use of biomodels had reduced operating time by a mean of 16% and were cost effective at a mean price of $1100 AUS. CONCLUSION: Biomodelling was reported as an intuitive, user-friendly technology that facilitated diagnosis, operative planning and communication between colleagues and patients. Limitations of the technology were manufacturing time and cost.

Attitude of Health Personnel↗

Accuracy of stereolithographic models of human anatomy.

A study was undertaken to determine the dimensional accuracy of anatomical replicas derived from X-ray 3D computed tomography (CT) images and produced using the rapid prototyping technique of stereolithography (SLA). A dry bone skull and geometric phantom were scanned, and replicas were produced. Distance measurements were obtained to compare the original objects and the resulting replicas. Repeated measurements between anatomical landmarks were used for comparison of the original skull and replica. Results for the geometric phantom demonstrate a mean difference of +0.47 mm, representing an accuracy of 97.7-99.12%. Measurements of the skull produced a range of absolute differences (maximum +4.62 mm, minimum +0.1 mm, mean +0.85 mm). These results support the use of SLA models of human anatomical structures in such areas as pre-operative planning of complex surgical procedures. For applications where higher accuracy is required, improvements can be expected by utilizing smaller pixel resolution in the CT images. Stereolithographic models can now be confidently employed as accurate, three-dimensional replicas of complex, anatomical structures.

Humans↗

Integration of 3-D medical imaging and rapid prototyping to create stereolithographic models.

This paper describes current research into the creation of solid models which replicate anatomical structures using rapid prototyping techniques. Stereolithography is particularly efficient in the production of highly-complex structures. This technique was applied to the fabrication of a plastic model of a human skull. A geometric definition of the object was obtained by transferring the three-dimensional medical image volume (x-ray CT) and processing the data on a computer graphics workstation. A 3-D biomedical visualisation software package (ANALYZETM) was used to perform segmentation of structures. A 3-D triangular-mesh representation of the selected structure was calculated and converted to a format suitable for processing and construction using stereolithography (SLA). Improvements in the quality of the anatomical model produced will result from improved data processing techniques. Future work is proposed to investigate the influence of imaging parameters and data processing techniques on the resultant plastic models.

Humans↗