PubMed Health⌕ Search

Biomedical subjects

W J van der Giessen

Publications and source records attributed to W J van der Giessen.

At least 19 recordsLinked to original sources

Reduction in infarct size, but no functional improvement after bone marrow cell administration in a porcine model of reperfused myocardial infarction.

AIMS: Stem cell therapy after myocardial infarction (MI) has been studied in models of permanent coronary occlusion. We studied the effect of intracoronary administration of unselected bone marrow (BM) and mononuclear cells (MNC) in a porcine model of reperfused MI. METHODS AND RESULTS: In 34 swine, the left circumflex coronary artery was balloon-occluded for 2 h followed by reperfusion. Ten swine without MI served as controls. All swine underwent magnetic resonance imaging (MRI) 1 week post-MI. The next day, 10 of the 30 surviving MI swine received BM, 10 other MI swine received MNC, and the remaining MI swine received medium intracoronary. Four weeks later, all swine underwent a follow-up MRI. One week after MI, end-diastolic volume (92+/-16 mL) and left ventricular (LV) weight (78+/-12 g) were greater, whereas ejection fraction (40+/-8%) was lower than in controls (69+/-11 mL, 62+/-13 g, and 53+/-6%). Injection of BM or MNC had no effect on the MI-induced changes in global or regional LV-function. However, there was a significant reduction in infarct size 4 weeks after MNC injection (-6+/-3%) compared with the medium (-3+/-5%). CONCLUSION: Intracoronary injection of BM or MNC in swine does not improve regional or global LV-function 4 weeks after injection. However, a reduction in infarct-size was noted after MNC injection.

Animals↗

One year clinical follow up of paclitaxel eluting stents for acute myocardial infarction compared with sirolimus eluting stents.

OBJECTIVE: To compare clinical outcome of paclitaxel eluting stents (PES) versus sirolimus eluting stents (SES) for the treatment of acute ST elevation myocardial infarction. DESIGN AND PATIENTS: The first 136 consecutive patients treated exclusively with PES in the setting of primary percutaneous coronary intervention for acute myocardial infarction in this single centre registry were prospectively clinically assessed at 30 days and one year. They were compared with 186 consecutive patients treated exclusively with SES in the preceding period. SETTING: Academic tertiary referral centre. RESULTS: At 30 days, the rate of all cause mortality and reinfarction was similar between groups (6.5% v 6.6% for SES and PES, respectively, p = 1.0). A significant difference in target vessel revascularisation (TVR) was seen in favour of SES (1.1% v 5.1% for PES, p = 0.04). This was driven by stent thrombosis (n = 4), especially in the bifurcation stenting (n = 2). At one year, no significant differences were seen between groups, with no late thrombosis and 1.5% in-stent restenosis (needing TVR) in PES versus no reinterventions in SES (p = 0.2). One year survival free of major adverse cardiac events (MACE) was 90.2% for SES and 85% for PES (p = 0.16). CONCLUSIONS: No significant differences were seen in MACE-free survival at one year between SES and PES for the treatment of acute myocardial infarction with very low rates of reintervention for restenosis. Bifurcation stenting in acute myocardial infarction should, if possible, be avoided because of the increased risk of stent thrombosis.

Adult↗

Routine sirolimus eluting stent implantation for unselected in-stent restenosis: insights from the rapamycin eluting stent evaluated at Rotterdam Cardiology Hospital (RESEARCH) registry.

OBJECTIVE: To assess the effectiveness of routine sirolimus eluting stent (SES) implantation for unselected patients with in-stent restenosis and to provide preliminary information about the angiographic outcome for lesion subgroups and for different in-stent restenosis patterns. DESIGN: Prospective, single centre registry. SETTING: Tertiary referral centre. PATIENTS: 44 consecutive patients (53 lesions) without previous brachytherapy who were treated with SES for in-stent restenosis were evaluated. Routine angiographic follow up was obtained at six months and the incidence of major adverse cardiovascular events was evaluated. RESULTS: At baseline, 42% of the lesions were focal, 21% diffuse, 26% proliferative, and 11% total occlusions. Small vessel size (reference diameter < or = 2.5 mm) was present in 49%, long lesions (> 20 mm) in 30%, treatment of bypass grafts in 13%, and bifurcation stenting in 18%. At follow up, post-SES restenosis was observed in 14.6%. No restenosis was observed in focal lesions. For more complex lesions, restenosis rates ranged from 20-25%. At the one year follow up, the incidence of death was 0, myocardial infarction 4.7% (n = 2), and target lesion revascularisation 16.3% (n = 7). The target lesion was revascularised because of restenosis in 11.6% (n = 5). CONCLUSIONS: Routine SES implantation is highly effective for focal in-stent restenosis and appears to be a promising strategy for more complex patterns of restenosis.

Aged↗

Sonotherapy, antirestenotic therapeutic ultrasound in coronary arteries: the first clinical experience.

We studied the safety and feasibility of intracoronary sonotherapy (IST) and its effect on the coronary vessel at 6 months. Thirty-seven patients with stable or unstable angina were included (40 lesions). The indication was de novo lesion (n = 26), restenosis (n = 2), in-stent restenosis (n = 11), and a total occlusion of a venous bypass graft. After successful angioplasty, IST was performed using a 5 Fr catheter with three serial ultrasound transducers operating at 1 MHz. IST was successfully performed in 36 lesions (success rate, 90%). IST exposure time per lesion was 718 +/- 127 sec. During hospital stay, one patient died due to a bleeding complication. At 6-month follow-up, one patient experienced acute myocardial infarction, eight patients underwent repeat PTCA. No patient underwent CABG. Late lumen loss was 1.05 +/- 0.70 mm with a restenosis rate of 25%. IVUS analysis revealed a neointima burden of 25% +/- 11%. IST can be applied safely and with high acute procedural success. Sonotherapy-related major adverse events were not observed. Late lumen loss and neointimal growth were similar to conventional PTCA approaches. These results justify the initiation of randomized clinical efficacy studies.

Aged↗

Initial observation regarding changes in vessel dimensions after balloon angioplasty and stenting followed by catheter-based beta-radiation. Is stenting necessary in the setting of catheter-based radiotherapy?

AIMS: We sought to compare the effect of intracoronary beta-radiation on the vessel dimensions in de novo lesions using three-dimensional intravascular ultrasound quantification after balloon angioplasty and stenting. METHODS AND RESULTS: Forty patients (44 vessels; 28 balloon angioplasty and 16 stenting) treated with catheter-based beta-radiation and 18 non-irradiated control patients (18 vessels; 10 balloon angioplasty and 8 stenting) were investigated by means of three-dimensional volumetric intravascular ultrasound analysis post-procedure and at 6-8 months follow-up. Total vessel (EEM) volume enlarged after both balloon angioplasty and stenting (+37 mm(3) vs +42 mm(3), P=ns), but vessel wall volume (plaque plus media) also increased similarly (+33 mm(3) vs +49 mm(3), P=ns) in the irradiated patients. Lumen volume remained unchanged in both groups (+3 mm(3) vs -7 mm(3), P=ns). In the stent-covered segments, neointima at follow-up was significantly smaller in the irradiated group than the control group (8 mm(3) vs 27 mm(3), P=0.001, respectively), but the total amount of tissue growth was similar in both groups (33 mm(3) vs 29 mm(3), P=ns). CONCLUSIONS: Intracoronary beta-radiation induces vessel enlargement after balloon angioplasty and/or stenting, accommodating tissue growth. Additional stenting may not play an important role in the prevention of constrictive remodelling in the setting of catheter-based intracoronary beta-radiotherapy.

Aged↗

Routine intracoronary beta-irradiation. Acute and one year outcome in patients at high risk for recurrence of stenosis.

AIMS: Intracoronary radiation is a promising therapy potentially reducing restenosis following catheter-based interventions. Currently, only limited data on this treatment are available. The feasibility and outcome in daily routine practice, however, is unknown. METHODS AND RESULTS: In 100 consecutive patients, intracoronary beta-radiation was performed with a (90)Strontium system (Novoste Beta-Cathtrade mark) following angioplasty. Predominantly complex (73% type B2 and C) and long lesions (length 24.3+/-15.3 mm) were included (37% de novo, 19% restenotic and 44% in-stent restenotic lesions). Radiation success was 100%. Mean prescribed dose was 19.8+/-2.5 Gy. A pullback procedure was performed in 19% lesions. Geographic miss occurred in 8% lesions. Periprocedural thrombus formation occurred in four lesions, dissection in nine lesions. During hospital stay, no death, acute myocardial infarction, or repeat revascularization was observed. Major adverse cardiac events occurred predominantly between 6 and 12 months after the index procedure with major adverse cardiac event-free survival of 66% at 12 months (one death, 10 Q-wave myocardial infarctions, 23 target vessel revascularizations; ranked for worst event). CONCLUSION: Routine catheter-based intracoronary beta-radiation therapy after angioplasty is safe and feasible with a high acute procedural success. The clinical 1-year follow-up showed delayed occurrence of major adverse cardiac events between 6 and 12 months after the index procedure.

Aged↗

Platelet GP IIb/IIIa receptor blockers for failed thrombolysis in acute myocardial infarction, alone or as adjunct to other rescue therapies; single centre retrospective analysis of 548 consecutive patients with acute myocardial infarction.

In order to study the safety of 'rescue' strategies in the treatment of patients with failed thrombolysis, all 548 patients admitted with evolving myocardial infarction to the Thoraxcenter, Rotterdam, from January 1997 until April 1999 were reviewed. Of these patients, 49% had received thrombolysis. Of patients treated with thrombolysis and not referred from other hospitals (n = 154) 36% received rescue therapy for failed thrombolysis. Three rescue therapies were used after failed thrombolysis: percutaneous coronary intervention (74%), retreatment with thrombolysis (39%) and platelet glycoprotein (GP) IIb/IIIa receptor blockers (53%), often in combination. Platelet GP IIb/IIIa receptor blockers were administered in 64% of patients treated with rescue percutaneous coronary intervention. Major bleeding occurred in 14% of all thrombolysis treated patients, and in 30% of patients who received multiple rescue therapies. Bleeding was related to heparin usage and platelet GP IIb/IIIa receptor blockers, as was the insertion of catheters for percutaneous coronary intervention or intra-aortic balloon pumps. Major bleeding resulted in one death due to a ruptured ventricle, one haemorrhagic stroke, and three cases of tamponade for which surgery was needed. Four of these patients had received combination rescue therapy. Rescue therapy is a widely used strategy for failed thrombolysis, but is associated with a high bleeding rate. Alternative reperfusion strategies to avoid failed thrombolysis should be considered in high risk patients.

Angioplasty, Balloon, Coronary↗

Radioactive stents delay but do not prevent in-stent neointimal hyperplasia.

BACKGROUND: Restenosis after conventional stenting is almost exclusively caused by neointimal hyperplasia. Beta-particle-emitting radioactive stents decrease in-stent neointimal hyperplasia at 6-month follow-up. The purpose of this study was to evaluate the 1-year outcome of (32)P radioactive stents with an initial activity of 6 to 12 microCi using serial quantitative coronary angiography and volumetric ECG-gated 3D intravascular ultrasound (IVUS). METHODS AND RESULTS: Of 40 patients undergoing initial stent implantation, 26 were event-free after the 6-month follow-up period and 22 underwent repeat catheterization and IVUS at 1 year; they comprised half of the study population. Significant luminal deterioration was observed within the stents between 6 months and 1 year, as evidenced by a decrease in the angiographic minimum lumen diameter (-0.43+/-0.56 mm; P:=0.028) and in the mean lumen diameter in the stent (-0.55+/-0. 63 mm; P:=0.001); a significant increase in in-stent neointimal hyperplasia by IVUS (18.16+/-12.59 mm(3) at 6 months to 27.75+/-11. 99 mm(3) at 1 year; P:=0.001) was also observed. Target vessel revascularization was performed in 5 patients (23%). No patient experienced late occlusion, myocardial infarction, or death. By 1 year, 21 of the initial 40 patients (65%) remained event-free. CONCLUSIONS: Neointimal proliferation is delayed rather than prevented by radioactive stent implantation. Clinical outcome 1 year after the implantation of stents with an initial activity of 6 to 12 microCi is not favorable when compared with conventional stenting.

Adult↗

Clinical and angiographical follow-up after implantation of a 6--12 microCi radioactive stent in patients with coronary artery disease.

AIMS: This study is the contribution by the Thoraxcenter, Rotterdam, to the European(32)P Dose Response Trial, a non-randomized multicentre trial to evaluate the safety and efficacy of the radioactive Isostent in patients with single coronary artery disease. METHODS AND RESULTS: The radioactivity of the stent at implantation was 6--12 microCi. All patients received aspirin indefinitely and either ticlopidine or clopidogrel for 3 months. Quantitative coronary angiography measurements of both the stent area and the target lesion (stent area and up to 5 mm proximal and distal to the stent edges) were performed pre- and post-procedure and at the 5-month follow-up. Forty-two radioactive stents were implanted in 40 patients. Treated vessels were the left anterior descending coronary artery (n=20), right coronary artery (n=10) or left circumflex artery (n=10). Eight patients received additional non-radioactive stents. Lesion length measured 10+/-3 mm with a reference diameter of 3.07+/-0.69 mm. Minimal lumen diameter increased from 0.98+/-0.53 mm pre-procedure to 2.29+/-0.52 mm (target lesion) and 2.57+/-0.44 mm (stent area) post-procedure. There was one procedural non-Q wave myocardial infarction, due to transient thrombotic closure. Thirty-six patients returned for angiographical follow-up. Two patients had a total occlusion proximal to the radioactive stent. Of the patent vessels, none had in-stent restenosis. Edge restenosis was observed in 44%, occurring predominantly at the proximal edge. Target lesion revascularization was performed in 10 patients and target vessel revascularization in one patient. No additional clinical end-points occurred during follow-up. The minimal lumen diameter at follow-up averaged 1.66+/-0.71 mm (target lesion) and 2.12+/-0.72 (stent area); therefore late loss was 0.63+/-0.69 (target lesion) and 0.46+/-0.76 (stent area), resulting in a late loss index of 0.65+/-1.15 (target lesion) and 0.30+/-0.53 (stent area). CONCLUSION: These results indicate that the use of radioactive stents is safe and feasible, however, the high incidence of edge restenosis makes this technique currently clinically non-applicable.

Adult↗

The pattern of restenosis and vascular remodelling after cold-end radioactive stent implantation.

BACKGROUND: Edge restenosis is a major problem after radioactive stenting. The cold-end stent has a radioactive mid-segment (15.9 mm) and non-radioactive proximal and distal 5.7 mm segments. Conceptually this may negate the impact of negative vascular remodelling at the edge of the radiation. METHOD AND RESULTS: ECG-gated intravascular ultrasound with three-dimensional reconstruction was performed post-stent implantation and at the 6-month follow-up to assess restenosis within the margins of the stent and at the stent edges in 16 patients. Angiographic restenosis was witnessed in four patients, all in the proximal in-stent position. By intravascular ultrasound in-stent neointimal hyperplasia, with a >50% stented cross-sectional area, was seen in eight patients. This was witnessed proximally (n=2), distally (n=2) and in both segments (n=4). Echolucent tissue, dubbed the 'black hole' was seen as a significant component of neointimal hyperplasia in six out of the eight cases of restenosis. Neointimal hyperplasia was inhibited in the area of radiation: Delta neointimal hyperplasia=3.72 mm3 (8.6%); in-stent at the edges of radiation proximally and distally Delta neointimal hyperplasia was 7.9 mm3 (19.0%) and 11.4 mm3 (25.6%), respectively (P=0.017). At the stent edges there was no significant change in lumen volume. CONCLUSIONS: Cold-end stenting results in increased neointimal hyperplasia in in-stent non-radioactive segments.

Brachytherapy↗

Coronary restenosis elimination with a sirolimus eluting stent: first European human experience with 6-month angiographic and intravascular ultrasonic follow-up.

AIMS: Coronary stenting is limited by a 10%-60% restenosis rate due to neointimal hyperplasia. Sirolimus is a macrocyclic lactone agent that interacts with cell-cycle regulating proteins and inhibits cell division between phases G1 and S1. The hypothesis tested in this study is that local delivery of sirolimus with an eluting stent can prevent restenosis. METHODS AND RESULTS: Fifteen patients were treated with 18 mm sirolimus eluting BX VELOCITY stents. Quantitative angiography and three-dimensional quantitative intravascular ultrasound were performed at implantation and at the 6 months follow-up. All stent implantations were successful. One patient died on day 2, of cerebral haemorrhage and one patient suffered a subacute stent occlusion due to edge dissection (re-PTCA, CKMB 42). At 9 months no further adverse events had occurred and all patients were angina free. Quantitative coronary angiography revealed no change in minimal lumen diameter and percent diameter stenosis and hence no in-lesion or in-stent restenosis. Quantitative intravascular ultrasound showed that intimal hyperplasia volume and percent obstruction volume at follow-up were negligible at 5.3 mm(3)and 1.8%, respectively. No edge effect was observed in the segments proximal and distal to the stents. CONCLUSION: Implantation of a sirolimus-eluting stent seems to effectively prevent intimal hyperplasia.

Adult↗

Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation.

BACKGROUND: Recent reports demonstrate that intracoronary radiation affects not only neointimal formation but also vascular remodeling. Radioactive stents and catheter-based techniques deliver radiation in different ways, suggesting that different patterns of remodeling after each technique may be expected. METHODS AND RESULTS: We analyzed remodeling in 18 patients after conventional stent implantation, 16 patients after low-activity radioactive stent implantation, 16 patients after higher activity radioactive stent implantation, and, finally, 17 patients who underwent catheter-based radiation followed by conventional stent implantation. Intravascular ultrasound with 3D reconstruction was used after stent implantation and at the 6-month follow-up to assess remodeling within the stent margins and at its edges. Preprocedural characteristics were similar between groups. In-stent neointimal hyperplasia (NIH) was inhibited by high-activity radioactive stent implantation (NIH 9.0 mm(3)) and by catheter-based radiation followed by conventional stent implantation (NIH 6.9 mm(3)) compared with low-activity radioactive stent implantation (NIH 21.2 mm(3)) and conventional stent implantation (NIH 20.8 mm(3)) (P:=0.008). No difference in plaque or total vessel volume was seen behind the stent in the conventional, low-activity, or high-activity stent implantation groups. However, significant increases in plaque behind the stent (15%) and in total vessel volume (8%) were seen in the group that underwent catheter-based radiation followed by conventional stent implantation. All 4 groups demonstrated significant late lumen loss at the stent edges; however, edge restenosis was seen only in the group subjected to high-activity stent implantation and appeared to be due to an increase in plaque and, to a lesser degree, to negative remodeling. CONCLUSIONS: Distinct differences in the patterns of remodeling exist between conventional, radioactive, and catheter-based radiotherapy with stenting.

Adult↗

Inhibition of restenosis with beta-emitting radiotherapy: Report of the Proliferation Reduction with Vascular Energy Trial (PREVENT).

BACKGROUND: Intracoronary gamma- and beta-radiation have reduced restenosis in animal models. In the clinical setting, the effectiveness of beta-emitters has not been studied in a broad spectrum of patients, particularly those receiving stents. METHODS AND RESULTS: A prospective, randomized, sham-controlled study of intracoronary radiotherapy with the beta-emitting (32)P source wire, using a centering catheter and automated source delivery unit, was conducted. A total of 105 patients with de novo (70%) or restenotic (30%) lesions who were treated by stenting (61%) or balloon angioplasty (39%) received 0 (control), 16, 20, or 24 Gy to a depth of 1 mm in the artery wall. Angiography at 6 months showed a target site late loss index of 11+/-36% in radiotherapy patients versus 55+/-30% in controls (P:<0.0001). A low late loss index was seen in stented and balloon-treated patients and was similar across the 16, 20, and 24 Gy radiotherapy groups. Restenosis (>/=50%) rates were significantly lower in radiotherapy patients at the target site (8% versus 39%; P:=0.012) and at target site plus adjacent segments (22% versus 50%; P:=0.018). Target lesion revascularization was needed in 5 radiotherapy patients (6%) and 6 controls (24%; P:<0.05). Stenosis adjacent to the target site and late thrombotic events reduced the overall clinical benefit of radiotherapy. CONCLUSIONS: beta-radiotherapy with a centered (32)P source is safe and highly effective in inhibiting restenosis at the target site after stent or balloon angioplasty. However, minimizing edge narrowing and late thrombotic events must be accomplished to maximize the clinical benefit of this modality.

Angioplasty, Balloon, Coronary↗

True 3-dimensional reconstruction of coronary arteries in patients by fusion of angiography and IVUS (ANGUS) and its quantitative validation.

BACKGROUND: True 3D reconstruction of coronary arteries in patients based on intravascular ultrasound (IVUS) may be achieved by fusing angiographic and IVUS information (ANGUS). The clinical applicability of ANGUS was tested, and its accuracy was evaluated quantitatively. METHODS AND REUSLTS: In 16 patients who were investigated 6 months after stent implantation, a sheath-based catheter was used to acquire IVUS images during an R-wave-triggered, motorized stepped pullback. First, a single set of end-diastolic biplane angiographic images documented the 3D location of the catheter at the beginning of pullback. From this set, the 3D pullback trajectory was predicted. Second, contours of the lumen or stent obtained from IVUS were fused with the 3D trajectory. Third, the angular rotation of the reconstruction was optimized by quantitative matching of the silhouettes of the 3D reconstruction with the actual biplane images. Reconstructions were obtained in 12 patients. The number of pullback steps, which determines the pullback length, closely agreed with the reconstructed path length (r=0.99). Geometric measurements in silhouette images of the 3D reconstructions showed high correlation (0.84 to 0.97) with corresponding measurements in the actual biplane angiographic images. CONCLUSIONS: With ANGUS, 3D reconstructions of coronary arteries can be successfully and accurately obtained in the majority of patients.

Coronary Angiography↗

Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy.

BACKGROUND: A recognized limitation of endovascular beta-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary beta-radiation. METHODS AND RESULTS: We analyzed 50 consecutive patients treated with beta-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis. By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84+/-0.6 versus 0.15+/-0.4 and 0.09+/-0.4 mm, respectively; P<0.0001). Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). CONCLUSIONS: These data support the hypothesis that the combination of injury and low-dose beta-radiation induces deleterious outcome.

Angioplasty, Balloon, Coronary↗

Residual plaque burden, delivered dose, and tissue composition predict 6-month outcome after balloon angioplasty and beta-radiation therapy.

BACKGROUND: Inhomogeneity of dose distribution and anatomic aspects of the atherosclerotic plaque may influence the outcome of irradiated lesions after balloon angioplasty (BA). We evaluated the influence of delivered dose and morphological characteristics of coronary stenoses treated with beta-radiation after BA. METHODS AND RESULTS: Eighteen consecutive patients treated according to the Beta Energy Restenosis Trial 1.5 were included in the study. The site of angioplasty was irradiated with the use of a beta-emitting (90)Sr/(90)Y source. With the side branches used as anatomic landmarks, the irradiated area was identified and volumetric assessment was performed by 3D intracoronary ultrasound imaging after treatment and at 6 months. The type of tissue, the presence of dissection, and the vessel volumes were assessed every 2 mm within the irradiated area. The minimal dose absorbed by 90% of the adventitial volume (D(v90)Adv) was calculated in each 2-mm segment. Diffuse calcified subsegments and those containing side branches were excluded. Two hundred six coronary subsegments were studied. Of those, 55 were defined as soft, 129 as hard, and 22 as normal/intimal thickening. Plaque volume showed less increase in hard segments as compared with soft and normal/intimal thickening segments (P<0.0001). D(v90)Adv was associated with plaque volume at follow-up after a polynomial equation with linear and nonlinear components (r = 0.71; P = 0.0001). The multivariate regression analysis identified the independent predictors of the plaque volume at follow-up: plaque volume after treatment, D(v90)Adv, and type of plaque. CONCLUSIONS: Residual plaque burden, delivered dose, and tiss composition play a fundamental role in the volumetric outcome at 6-month follow-up after beta-radiation therapy and BA.

Angioplasty, Balloon, Coronary↗