PubMed Health⌕ Search

Biomedical subjects

W Keith Sootsman

Publications and source records attributed to W Keith Sootsman.

2 recordsLinked to original sources

Application accuracy of an electromagnetic field-based image-guided navigation system.

OBJECTIVE: We tested the application accuracy of an electromagnetic field-based image guidance system to compare it to traditional optically tracked systems. METHODS: A plastic skull phantom was fitted with fiducial markers rigidly attached via self-drilling bone screws. Volumetric CT scan was obtained to simulate the clinical condition. A metal disc marked in 1-mm increments was placed at the expected target point. Following registration and alignment of a trajectory guide, radial and depth localization errors were measured after both freehand and stabilized approaches on both the right and left sides. Statistical analyses of the localization errors were performed. RESULTS: Total target localization error ranged from 0.71 to 3.51 mm with a mean +/- SEM of 2.13 +/- 0.11 mm. The radial error averaged 0.98 +/- 0.11 mm, depth error 1.74 +/- 0.13 mm. The freehand procedures produced a statistically greater radial, depth and total error than the fixed procedures. CONCLUSIONS: Accuracy of image-guided localization using an electromagnetic field guidance system is similar to that reported for optically guided systems.

Diagnostic Imaging↗

Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging.

A methodology is presented for placing deep brain stimulator electrodes under direct MR image guidance. The technique utilized a small, skull-mounted trajectory guide that is optimized for accurate alignment under MR fluoroscopy. Iterative confirmation scans are used to monitor device alignment and brain penetration. The methodology was initially tested in a human skull phantom and proved capable of achieving submillimeter accuracy over a set of 16 separate targets that were accessed. The maximum error that was obtained in this preliminary test was 2 mm, motivating use of the technique in a clinical study. Subsequently, a total of eight deep brain stimulation electrodes were placed in five patients. Satisfactory placement was achieved on the first pass in seven of eight electrodes, while two passes were required with one electrode. Mean error from the intended target on the first pass was 1.0 +/- 0.8 mm (range = 0.1-1.9 mm). All procedures were considered technical successes and there were no intraoperative complications; however, one patient did develop a postoperative infection.

Brain↗