W Kenneth Ward

Publications and source records attributed to W Kenneth Ward.

12 recordsLinked to original sources

An implantable subcutaneous glucose sensor array in ketosis-prone rats: closed loop glycemic control.

A closed loop system of diabetes control would minimize hyperglycemia and hypoglycemia. We therefore implanted and tested a subcutaneous amperometric glucose sensor array in alloxan-diabetic rats. Each array employed four sensing units, the outputs of which were processed in real time to yield a unified signal. We utilized a gain-scheduled insulin control algorithm which rapidly reduced insulin delivery as glucose concentration declined. Such a system was generally effective in controlling glycemia and the degree of lag between blood glucose and the sensor signal was usually 3-8 min. After prolonged implantation, this lag was sometimes longer, which led to impairment of sensor accuracy. Using a prospective two-point calibration method, sensor accuracy and closed loop control were good. A revised algorithm yielded better glycemic control than the initial algorithm did. Future research needs to further improve calibration methods and reduce foreign body fibrosis in order to avoid a time-related increase in lag duration.

Algorithms↗

A novel insulin delivery algorithm in rats with type 1 diabetes: the fading memory proportional-derivative method.

An algorithm designed to automatically control insulin delivery was tested in rats with Type 1 diabetes. This nonlinear algorithm included a fading memory component of proportional and derivative errors in order to simulate normal insulin secretion. Error-weighting functions for the proportional and derivative terms were used with a performance index designed for error adaptation. In the first version of the algorithm, the proportional gain was adaptively varied. In the second version, a low rate of basal insulin delivery was adaptively varied. Six 6-h studies with each version were conducted using frequent blood sampling and intravenous insulin delivery. In Version 2 studies, blood glucose levels during the last two hours were well-controlled and significantly lower than in Version 1 (118 +/- 2.0 vs. 130 +/- 2.9 mg/dL). Neither version produced hypoglycemia. Future research using this algorithm needs to focus on automated glucose sensing in combination with insulin delivery.

Algorithms↗

The effect of local subcutaneous delivery of vascular endothelial growth factor on the function of a chronically implanted amperometric glucose sensor.

The foreign body capsule that forms around implanted devices such as glucose sensors is hypovascular and has limited permeability to glucose. Such a capsule may function better if well vascularized. We hypothesized that capsular vascularization achieved by local release of vascular endothelial growth factor (VEGF) would lead to enhanced function. Amperometric glucose sensor array disks, each with four indicating electrodes, were implanted into rats. Animals received local subcutaneous infusions of VEGF(165) via osmotic pumps at a location on the sensor face 2 mm from one of the electrodes ("near units"). "Intermediate" electrode units were 15 mm, and "distant" units were 22 mm, from the VEGF source. Every 2 weeks, a glucose infusion was given to assess sensor function by telemetry. Near units demonstrated a lower lag duration (delay after blood glucose) than intermediate and distant units. The mean absolute relative difference for near units was less than for distant units. The percentage of data pairs in the A region of the Clarke error grid of the near sensing units was greater than that of the distant units. Values for the functional measures for saline controls fell between near and distant VEGF values. Glucose sensor function was found to be more favorable in units immediately adjacent to the VEGF infusion port. The most likely cause for this finding is increased neovessel growth in the surrounding foreign body capsule. Slow release of angiogenic growth factors may be a potential method for chronically enhancing the function of a subcutaneously implanted biosensor.

Animals↗

A wire-based dual-analyte sensor for glucose and lactate: in vitro and in vivo evaluation.

Continuous measurement of lactate is potentially useful for detecting physical exhaustion and for monitoring critical care conditions characterized by hypoperfusion, such as heart failure. In some conditions, it may be desirable to monitor more than one metabolic parameter concurrently. For this reason, we designed and fabricated twisted wire-based microelectrodes that can measure both lactate and glucose. These dual-analyte sensors were characterized in vitro by measuring their response to the analyte of interest and to assess whether they were susceptible to interference from the other analyte. When measured in stirred aqueous buffer, lactate sensors detected a very small amount of crosstalk from glucose in vitro, although this signal was less than 3% of the response to lactate. Glucose sensors did not detect crosstalk from lactate. Sensors were implanted subcutaneously in rats and tested during infusions of lactate and glucose. Each sensing electrode responded rapidly to changes in its analyte concentration, and there was no evidence of in vivo crosstalk. This study constitutes proof of the concept that oxidase-based, amperometric wire microsensors can detect changes in glucose and lactate during subcutaneous implantation in rats.

Animals↗

Induction of type-1 diabetes mellitus in laboratory rats by use of alloxan: route of administration, pitfalls, and insulin treatment.

Uncertainties have existed regarding the systematic induction and management of drug-induced diabetes mellitus (DM). Issues have included the optimal route of administration of the drug, methods of reducing drug toxicosis and mortality, how to induce type-1 versus type-2 DM, and how to manage labile DM in rats. In attempting to induce type-1 DM in Sprague-Dawley rats, we classified hyperglycemic animals as having type-1 DM only if their post-treatment blood ketone concentration was high. We found that multiple doses of alloxan led to significantly higher mortality than did a single dose. A single high dose (200 mg/kg of body weight given intraperitoneally) was the best treatment and led to 70% incidence of type-1 DM and only 10% mortality. In contrast, intravenous administration of similar doses was toxic. Assiduous management of alloxan-induced DM is crucial to avoid severe hypoglycemia from massive insulin release and to avoid diabetic ketoacidosis. Frequent glucose monitoring and appropriate administration of carbohydrate and fluids is necessary during this stage. For long-term management, daily administration of long-acting insulin (glargine) appears to be safe and effective. Rapid-acting insulins reduce glucose concentration rapidly, and must be used with caution. If specific precautions are observed, intraperitoneal administration of high-dose alloxan to laboratory rats leads to a condition that closely resembles human type-1 DM.

Alloxan↗

Vascularizing the tissue surrounding a model biosensor: how localized is the effect of a subcutaneous infusion of vascular endothelial growth factor (VEGF)?

Implantable continuous biosensors would improve disease management but long term function of such devices have been limited by a hypovascular foreign body capsule that inhibits influx of analytes. To assess whether capsule vascularity could be increased, we studied the histologic effects of a 28-day continuous infusion of vascular endothelial growth factor (VEGF) (0.45 microg/day) vs. saline from the surface of a model disk biosensor that was implanted subcutaneously in rats. At day 40, tissue was obtained at varying distances from the infusion port and capsular microvessels were counted using two histologic techniques. VEGF treatment led to a marked increase in capillary density. In tissue located 1 mm away from the infusion site, capillary density in VEGF-treated animals was 200-300% higher than in saline controls. Tissue located 13 mm away, but not 25 mm away, also demonstrated neovascularization. Serum obtained from a distant vein during the infusion did not show an elevated concentration of VEGF. These data demonstrate that a subcutaneous infusion of VEGF creates localized neovascularization of the foreign body capsule and suggest that systemic effects of VEGF are avoidable. Vascularization of a foreign body capsule surrounding a subcutaneous biosensor might well extend its useful life.

Animals↗

A fully implantable subcutaneous glucose sensor array: enhanced accuracy from multiple sensing units and a median-based algorithm.

Although continuous electrochemical glucose monitoring holds promise in the management of diabetes, its utility is limited in part because of error of unclear origin. The use of redundant glucose sensors in an array might reduce such error. We hypothesized that in a subcutaneously implanted array, a median-based continuous computation that excludes outlying data would lead to more accurate glucose measurement than averaging of all signals. Each rat was implanted with an array of four sensing units, and each unit transmitted data independently to an external monitoring device. Animals underwent perturbation of glucose by insulin infusions in diabetic animals and glucose infusions in nondiabetic animals, and in both, capillary glucose monitoring was performed frequently. Repeat glucose perturbation studies were performed every 1-2 weeks. We observed that a median-based technique, the Z-score with Median Absolute Deviation (ZMAD), consistently led to greater sensing accuracy as compared with signal averaging. The ZMAD technique yielded a correlation coefficient of 0.93, and 96% of values fell in the A and B regions of the Clarke error grid, demonstrating a high degree of accuracy of the unified signal. When tested in an implanted array of glucose sensors, a median-based technique (ZMAD) yields an accurate unified signal, and its accuracy is superior to signal averaging.

Algorithms↗

The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants.

We addressed the effect of implant thickness, implant porosity, and polyurethane (PU) chemistry on angiogenesis and on the foreign body response in rats. The following materials were implanted subcutaneously for 7 weeks then excised for histologic analysis: a solid PU; a solid polyurethane with silicone and polyethylene oxide (PU-S-PEO); porous expanded polytetrafluoroethylene (ePTFE); and porous polyvinyl alcohol sponge (PVA). Two thicknesses of PU-S-PEO were compared: 300 microns (thin) and 2000 microns (thick). Foreign body capsule (FBC) thickness was much less in PU-S-PEO implants than in PU implants. In addition, FBC were thinner in thin implants than in thick implants. FBC was much more dense in solid implants than in porous implants. As compared with solid implants, porous implants (PVA and ePTFE) led to a marked increase in the number of microvessels that developed adjacent to the implant, as observed both with hematoxylin/eosin staining and with an immunohistochemical anti-endothelial stain. We conclude that the polyethylene oxide and silicone moieties in PU reduce the thickness of the subsequent FBC. In addition, thin implants lead to a thin FBC. Porous implants (PVA and ePTFE) cause more angiogenesis than solid implants. These results may have implications for the measurement of blood-derived analytes by biosensors.

Animals↗

A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation.

For biosensor fabrication, it is important to optimize materials and methods in order to create predictable function in vitro and in vivo. For this reason, we designed a new glucose sensor ('revised protocol') that utilized an outer permselective membrane made of amphiphobic polyurethane which allows glucose passage through hydrophilic segments. An inner polyethersulfone membrane, stabilized with a trimethoxysilane, provided specificity. Before application of the inner membrane, it was necessary to etch the platinum electrode with a radio frequency oxygen plasma. The revised protocol sensors (n=185) were compared with sensors fabricated with an earlier ('original') protocol (n=204) which used an outer polyurethane without hydrophilic segments and a complex inner membrane of cellulose acetate and Nafion. The function of revised protocol sensors was more predictable in vitro as evidenced by a much lower variation of glucose sensitivity than the original protocol sensors. Revised and original protocol sensors were nearly linear up to a glucose concentration of 20 mM. In vitro interference from 0.1 mM acetaminophen was minimal in both groups of sensors and would be expected to represent about 2% of the total sensor response at normal glucose levels for revised protocol sensors. Prolonged testing of the revised protocol sensors for 11 days during immersion in buffer revealed stable sensitivities (day 1: 6.12+/-1.34 nA/mM; day 3: 6.33+/-1.40; day 8: 7.13+/-1.39; and day 11: 7.56+/-1.47; sensitivity for day 1 vs. each other day: not significant) and no critical loss of glucose oxidase activity. The response of the revised protocol sensors (n=7) to intraperitoneal glucose was tested in rats approximately one day after subcutaneous implantation and the sensors tracked glucose closely with a slight lag of 3-6 min.

Animals↗

Prevention of hypoglycemia using risk assessment with a continuous glucose monitoring system.

Due to the lag between sugar intake and the beginning of recovery from hypoglycemia, it is necessary to intervene in an anticipatory way if one wants to prevent, not only detect, hypoglycemia. This article presents the principle of a hypoglycemia prevention system based on risk assessment. The risk situation can be defined as the moment when the system estimates that the glucose concentration is expected to reach a hypoglycemia threshold in less than a given time (e.g., 20 min). Since there are well-known discrepancies between blood and interstitial glucose concentrations, the aim of this experimental study performed in nondiabetic rats was first to validate this strategy, and second to determine whether it can work when the glucose concentration is estimated by a glucose sensor in subcutaneous tissue rather than in blood. We used a model of controlled decrease in blood glucose concentration. A glucose infusion, the profile of which mimicked the appearance of glucose from an intragastric load, was administered either when hypoglycemia was detected or on the basis of risk recognition. Despite the lag between the beginning of the load and that of the increase in blood glucose concentration, which was in all experiments 15-20 min, hypoglycemia was fully prevented without overshoot hyperglycemia in the groups of rats in which the glucose load was started when the hypoglycemia risk was detected, on the basis of either blood or interstitial glucose concentration. This was, of course, not the case when the same glucose load was infused at the detection of the hypoglycemia threshold.

Animals↗