PubMed Health⌕ Search

Biomedical subjects

W L Foley

Publications and source records attributed to W L Foley.

13 recordsLinked to original sources

Patient-controlled analgesia: a comparison of dosing regimens for acute postsurgical pain.

This study compares several dosing regimens for patient-controlled analgesia (PCA) in the management of acute maxillofacial surgical pain. The dosing methods differed by presence or absence of an active drug (morphine [MS] vs saline), presence of a baseline infusion, and dose of drug delivered. Sixty-eight patients were enrolled in this prospective, randomized, double-blind, placebo-controlled trial that lasted 24 hours. The study was completed in two separate parts, each of which involved randomization of patients into four groups (part I) or three groups (part II). No significant differences were noted in pain scores in the preoperative, immediate postoperative, or 4-, 8-, 12-, or 24-hour periods among any of the groups, including the saline-only control groups; in either part I or part II of the study. Significant differences (P < .01), however, were noted in nausea and vomiting scores. Fifty percent (50%) of patients receiving MS vomited, while no patients in the saline groups vomited. This study calls into question the usefulness of PCA with MS in maxillofacial surgery patients. Pain control was questionable at best, and the rate of emesis was unacceptably high in patients with potentially compromised airways. Further research is required to determine if other analgesics provide better pain control with less nausea in the PCA system or if antiemetics can effectively be used to lower the incidence of nausea and vomiting.

Adolescent↗

Torque and pullout analysis of six currently available self-tapping and "emergency" screws.

Insertional torque (IT), stripping torque (ST), and uniaxial pullout tests were performed to evaluate the effectiveness of six screw systems (Wurzburg, Techmedica, Synthes, Timesh, Steinhouser, Luhr) in thin porcine rib. The Timesh 2.2-mm self-tapping screw produced the largest insertional and stripping torque of all systems tested as well as the largest difference between the insertional and stripping torque. The Timesh emergency screw also had the largest insertional and stripping torque as well as the largest difference between the insertional and stripping torque. In pullout tests, the Timesh screw was found to be the most retentive. The overall data indicated that the ideal self-tapping screw should have the largest difference possible between drill size and external diameter, a channel, and at least three self-tapping threads for maximum retention.

Animals↗

Expanding the specialty: a survey of oral and maxillofacial surgery residencies in the United States.

This article reports the results of a survey of oral and maxillofacial surgery (OMS) residency program directors regarding teaching of expanded scope surgical procedures during the academic year 1990 to 1991. Data is provided for the nation as a whole, as well as grouped by geographic regions and type of residency program. Significant differences were found for some procedures based on both geographic region and program type. The majority of program directors responding to this survey disagreed with the trend toward expanding the scope of OMS into cosmetic procedures. Directors of integrated dual degree programs believed that the trend toward expanding the scope of OMS was positive; 2:1 over directors of MD optional or traditional OMS programs.

Curriculum↗

Comparison between uniaxial pull-out tests and torque measurement of 2.0-mm self-tapping screws.

This study investigates the retentive capacity of 2.0-mm self-tapping screws in porcine rib utilizing axial pull-out tests as well as torque measurements of insertion and stripping. These techniques have been performed independently; this analysis assesses the association between pull-out and torque values. The Goodman-Kruskel correlation coefficient between pull-out and insertional torque is 0.13, while the correlation between pull-out and stripping torque is 0.21. Partial correlation indexes control the thickness of bone, a confounding factor. Nonparametric analysis of covariance showed no significant difference between insertion of screws and pull-out of the screws, but stripping versus pull-out test was significant. Given these findings, it appears that insertional torque may be used as an alternative technique for screw retention analysis. Because insertional torque tests can be conducted in the operating room, results of clinical studies can be compared to laboratory analyses.

Analysis of Variance↗

Evaluation of emergency screws in nonstripped pilot holes in bone.

Clinicians continue to search for a rigid internal fixation system that will remain stable in thin bone, such as that found in the lateral walls of the maxilla. Insertion of a large-diameter screw in a pilot hole has been suggested to improve screw retention. This study evaluates insertional and stripping torque of six emergency screw systems placed in nonstripped pilot holes of porcine rib (thickness < or = 2 mm). The Timesh and Synthes emergency screws did not properly fit into the nonstripped pilot holes. The Techmedica emergency screw was the most retentive. The Luhr, Wurzburg, and Steinhouser emergency screws were less retentive. The Techmedica emergency screw had the greatest stripping torque in nonstripped pilot holes, but it was not significantly greater when compared to the stripping torque of identical screws placed in 2.0-mm stripped holes. The Luhr, Wurzburg, and Steinhouser emergency screws placed in 1.5-mm pilot holes had significantly less stripping torque when compared to identical screws placed in 2.0-mm stripped holes. It appears the Luhr, Wurzberg, and Steinhouser 2.0-mm self-tapping screws have a greater stripping torque than the corresponding emergency screw when placed in 1.5-mm pilot holes.

Analysis of Variance↗

In vitro comparison of screw versus plate fixation in the sagittal split osteotomy.

This study evaluated the transverse strength (rigidity) of three groups of sagittal split osteotomies performed in vitro in fresh sheep mandibles. Fixation was accomplished utilizing two different position screw techniques and a monocortical plate technique. Osteotomies fixed with three 2.0-mm screws in an inverted-L pattern and those fixed with one monocortical miniplate were significantly more rigid than those fixed with two 2.7-mm screws placed in a linear pattern. No significant difference in rigidity was noted between the inverted-L group and the miniplate group.

Analysis of Variance↗

The effect of repetitive screw hole use on the retentive strength of pretapped and self-tapped screws.

Multiple systems for internal screw fixation are presently in use in oral and maxillofacial surgery. These systems differ in screw diameter, material, and design. This study evaluated the uniaxial pullout strength of five screw systems. Two-millimeter, 2.7-mm, and 3.5-mm screws were initially evaluated for pullout strength. Pretapped and self-tapped screws were then inserted into the same hole multiple times before pullout testing. Results of pullout testing revealed no significant difference in pullout strength of pretapped and self-tapped screws of equal diameter (P greater than .05). Increased screw diameter produced increased pullout strength. No significant difference in pullout strength was noted in pretapped or self-tapped screws inserted into the same hole one, two, or three times before pullout testing (P greater than .05).

Animals↗

Uniaxial pullout evaluation of internal screw fixation.

Multiple techniques of internal screw fixation are being used in clinical oral and maxillofacial surgery. This study evaluated the uniaxial pull-out strength of five commonly used screws and Kirschner pins placed by five different techniques. The pull-out strength of the Kirschner pins was significantly less (P greater than .0001) than that of the screws. The screw techniques did not differ significantly.

Animals↗

Internal screw fixation: comparison of placement pattern and rigidity.

Multiple screw placement patterns and techniques have been described for fixation of the sagittal split ramus osteotomy. This study evaluated transverse strength (rigidity) of six groups of simulated sagittal osteotomies fixed with different screw patterns and placement techniques. Osteotomies fixed with screws placed in an inverted L pattern were significantly more rigid than those fixed with screws placed in a linear pattern or K-wires placed in a triangular pattern (P less than .05). No significant difference in rigidity was noted between compression and bicortical screws placed in identical patterns.

Animals↗