PubMed Health⌕ Search

Biomedical subjects

W L Greenberg

Publications and source records attributed to W L Greenberg.

2 recordsLinked to original sources

Quantitative potentials of dynamic emission computed tomography.

Statistical uncertainties in emission computed tomography were simulated in 60 computer studies involving various numbers of events and distributions of activity. Previous studies have shown that for a uniform disc of activity of rms percentage of uncertainty per resolution cell is: 120 X (number of resolution cells)1/4 X (number of events per resolution cell)- 1/2. In this work we examined the more general situation where one or two regions of uniform activity are surrounded by a uniform background, and found that for an equal number of recorded events the uncertainties were reduced when the activity was concentrated in a portion of the field. The empirical relation rms % uncertainty in nt = 120(N)1/4(nt)-3/4, where nt is the number of events in an average target (organ) resolution cell and N is the total number of events recorded, satisfactorily described the relationships between uncertainties, contrast, total number of detected events, and number of resolution cells for all 60 computer studies. By means of this relation, we show the theoretical possibility of gated cardiac imaging with 20% uncertainty in 1 cm X 1 cm regions, and of 1-sec cerebral blood-flow images with 20% uncertainty in 2 cm X 2 cm regions.

Computers↗

Emission computer assisted tomography with single-photon and positron annihilation photon emitters.

Computed transverse section emission tomography using 99mTc with the Anger camera is compared to positron annihilation coincident detection using a ring of crystals and 68Ga. The single-photon system has a line spread function (LSF) of 9 mm full width at half maximum (FWHM) at the collimator and gives a transverse section reconstruction LSF of 11 mm FWHM with 144 views. The positron ring has a LSF of 6 mm at the center with a transverse section reconstruction LSF of 7.5 mm FWHM. Correction for uniformity of detector response and accurate center of rotation determination is essential in both techniques. The signal-to-noise ratio in a reconstruction is diminished by a factor of 1.2 x (number of resolution elements)1/4 over that expected from the average number of events per resolution element. Attenuation compensation causes more noise to appear in the center than the edge for both modes and an average increase in uncertainty of 30%. The effects of attenuation result in more loss of data for positron coincidence imaging than for single-photon imaging even at energies of 80 keV. For a 20-cm cylinder imaged in transverse section, only 20% of the positron annihilation events are not scattered; however, at 140 keV, 40% of the photons are not scattered. The relative crystal efficiency gives single-photon imaging an advantage of 5. On the other hand, the solid angle advantage of positron photon coincidence imaging is about 100 for the comparisons of this paper. Taking these factors into account, we find positron-computed section imaging has a tenfold increase in sensitivity over multiple-view imaging with the scintillation camera, which gives multiple sections but requires camera or patient rotation.

Elementary Particles↗