PubMed Health⌕ Search

Biomedical subjects

W M Holls

Publications and source records attributed to W M Holls.

3 recordsLinked to original sources

Ultra-low-noise instrumentation and computer-based data acquisition and processing system for obtaining a noninvasive and intrauterine catheter fetal electrocardiogram.

A fetal electrocardiogram (FECG) from the abdominal surface will be from 20 microVpp to unmeasurable. The intrauterine catheter signal will be from 50 microVpp to unmeasureable and will be corrupted with a significant direct current component of 10 to 200 microV. For electrophysiological information to be obtained from the abdominal and intrauterine catheter signals, the signals must be in a 0.05 to 100.0 Hz bandwidth. Because typical adult electrocardiogram systems have a noise specification of 5 to 10 microVpp from instrumentation, these systems are unacceptable for obtaining a FECG via the intrauterine catheter or noninvasively. Therefore, custom instrumentation has been developed with a noise specification of approximately 1.5 microVpp in a 0.05 to 100.0 Hz bandwidth. Design details of the custom instrumentation will be presented along with a laptop computer based data acquisition and signal processing system using LabVIEW. In addition, clinical data from the intrauterine catheter and noninvasive abdominal wall are presented to determine the feasibility of obtaining a FECG via the custom instrumentation. Clinical data obtained and documented indicates that after maternal electrocardiogram cancellation, a FECG with a good signal-to-noise ratio can be obtained in a diagnostic bandwidth of 0.05 to 100.0 Hz. Because the diagnostic bandwidth is preserved, electrophysiological information can be determined along with heart rate.

Catheterization↗

Cervical Gram stain for rapid detection of colonization with beta-streptococcus.

The group B beta-hemolytic streptococcus has been implicated in significant maternal and neonatal infections. The usual criteria for identifying the organism has been culture. A preliminary prospective study of the applicability of a simple, rapid, and readily available inexpensive screening tool, the Gram stain, was evaluated in 98 high-risk patients (premature rupture of the membranes and/or premature labor). In this selected population, cervical Gram stain was found to have a 98% negative predictive value for subsequent culture-proven group B beta-hemolytic streptococcus colonization. The sensitivity, specificity, and positive predictive values were, respectively, 93, 69, and 33%. Gram stain may be an appropriate test to assist in evaluation of group B beta-hemolytic streptococcus colonization in an at-risk population.

Female↗