PubMed Health⌕ Search

Biomedical subjects

W McDowell Anderson

Publications and source records attributed to W McDowell Anderson.

9 recordsLinked to original sources

Practice parameters for the dopaminergic treatment of restless legs syndrome and periodic limb movement disorder.

Dopaminergic agents, particularly dopamine agonists, have been used with increasing frequency in the treatment of restless legs syndrome and periodic limb movement disorder. These evidence-based practice parameters are complementary to the Practice Parameters for the Treatment of Restless Legs Syndrome and Periodic Limb Movement Disorder, published in 1999. These practice parameters were developed by the Standards of Practice Committee and reviewed and approved by the Board of Directors of the American Academy of Sleep Medicine. Recommendations are based on the accompanying comprehensive review of the medical literature regarding the dopaminergic treatment of restless legs syndrome (RLS) and periodic limb movement disorder (PLMD), which was developed by a task force commissioned by the American Academy of Sleep Medicine. The following recommendations serve as a guide to the appropriate use of dopaminergic agents in the treatment of RLS and PLMD. Levodopa with decarboxylase inhibitor, and the dopaminergic agonists pergolide, pramipexole, and ropinirole are effective in the treatment of RLS and PLMD. Other dopamine agonists (talipexole, cabergoline, piribidel, and alpha-dihydroergocryptine) and the dopaminergic agents amantadine and selegiline may be effective in the treatment of RLS and PLMD, but the level of effectiveness of these medications is not currently established. Lastly, no specific recommendations can be made regarding dopaminergic treatment of children or pregnant women with RLS or PLMD.

Dopamine Agonists↗

Practice parameters for the role of actigraphy in the study of sleep and circadian rhythms: an update for 2002.

Actigraphy is a method used to study sleep-wake patterns and circadian rhythms by assessing movement, most commonly of the wrist. These evidence-based practice parameters are an update to the Practice Parameters for the Use of Actigraphy in the Clinical Assessment of Sleep Disorders, published in 1995. These practice parameters were developed by the Standards of Practice Committee and reviewed and approved by the Board of Directors of the American Academy of Sleep Medicine. Recommendations are based on the accompanying comprehensive review of the medical literature regarding the role of actigraphy, which was developed by a task force commissioned by the American Academy of Sleep Medicine. The following recommendations serve as a guide to the appropriate use of actigraphy. Actigraphy is reliable and valid for detecting sleep in normal, healthy populations, but less reliable for detecting disturbed sleep. Although actigraphy is not indicated for the routine diagnosis, assessment, or management of any of the sleep disorders, it may serve as a useful adjunct to routine clinical evaluation of insomnia, circadian-rhythm disorders, and excessive sleepiness, and may be helpful in the assessment of specific aspects of some disorders, such as insomnia and restless legs syndrome/periodic limb movement disorder. The assessment of daytime sleepiness, the demonstration of multiday human-rest activity patterns, and the estimation of sleep-wake patterns are potential uses of actigraphy in clinical situations where other techniques cannot provide similar information (e.g., psychiatric ward patients). Superiority of actigraphy placement on different parts of the body is not currently established. Actigraphy may be useful in characterizing and monitoring circadian rhythm patterns or disturbances in certain special populations (e.g., children, demented individuals), and appears useful as an outcome measure in certain applications and populations. Although actigraphy may be a useful adjunct to portable sleep apnea testing, the use of actigraphy alone in the detection of sleep apnea is not currently established. Specific technical recommendations are discussed, such as using concomitant completion of a sleep log for artifact rejection and timing of lights out and on; conducting actigraphy studies for a minimum of three consecutive 24-hour periods; requiring raw data inspection; permitting some preprocessing of movement counts; stating that epoch lengths up to 1 minute are usually sufficient, except for circadian rhythm assessment; requiring interpretation to be performed manually by visual inspection; and allowing automatic scoring in addition to manual scoring methods.

Circadian Rhythm↗

Practice parameters for using polysomnography to evaluate insomnia: an update.

Insomnia is a common and clinically important problem. It may arise directly from a sleep-wake regulatory dysfunction and/or indirectly result from comorbid psychiatric, behavioral, medical, or neurological conditions. As an important public-health problem, insomnia requires accurate diagnosis and effective treatment. Insomnia is primarily diagnosed clinically with a detailed medical, psychiatric, and sleep history. Polysomnography is indicated when a sleep-related breathing disorder or periodic limb movement disorder is suspected, initial diagnosis is uncertain, treatment fails, or precipitous arousals occur with violent or injurious behavior. However, polysomnography is not indicated for the routine evaluation of transient insomnia, chronic insomnia, or insomnia associated with psychiatric disorders.

Chronic Disease↗

Gastric bypass is an effective treatment for obstructive sleep apnea in patients with clinically significant obesity.

BACKGROUND: We have demonstrated that obstructive sleep apnea (OSA) is prevalent in 60% of patients undergoing bariatric surgery. A study was conducted to determine whether weight loss following bariatric surgery ameliorates OSA. METHODS: All 100 consecutive patients with symptoms of OSA were prospectively evaluated by polysomnography before gastric bypass. Preoperative and postoperative scores of Epworth Sleepiness Scale (ESS), Respiratory Disturbance Index (RDI), and other parameters of sleep quality were compared using t-test. RESULTS: Preoperative RDI was 40 +/- 4 (normal 5 events/hour, n = 100). 13 patients had no OSA, 29 had mild OSA, while the remaining 58 patients were treated preoperatively for moderate-severe OSA. At a median of 6 months follow-up, BMI and ESS scores improved (38 +/- 1 vs 54 +/- 1 kg/m2, 6 +/- 1 vs 12 +/- 0.1, P < 0.001, postoperatively vs preoperatively). To date, 11 patients have completed postoperative polysomnography (3-21 months) after losing weight (BMI 40 +/- 2 vs 62 +/- 3 kg/m2, P < 0.001). There was significant improvement in ESS (3 +/- 1 vs 14 +/- 2), minimum O2 saturation (SpO2 86 +/- 2 vs 77 +/- 5), sleep efficiency (85 +/- 2% vs 65 +/- 5%), all P < 0.001, postop vs preop; and RDI (56 +/- 13 vs 23 +/- 7, P = 0.041). Regression analysis demonstrated no correlation between preoperative BMI, ESS score and the severity of OSA; and no correlation between % excess body weight loss and postoperative RDI. CONCLUSION: Weight loss following gastric bypass results in profound improvement in OSA. The severity of apnea cannot be reliably predicted by preoperative BMI and ESS; therefore, patients with symptoms of OSA should undergo polysomnography.

Comorbidity↗

Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. An American Academy of Sleep Medicine report.

Continuous positive airway pressure (CPAP) is used to treat patients with the obstructive sleep apnea syndrome (OSAS). The current standard is for an attendant technician to titrate CPAP during full polysomnography to obtain a fixed single pressure. The patient uses CPAP nightly at this fixed single pressure. Recently, devices using new technology that automatically titrate positive airway pressure (APAP) have become available. Such devices continually adjust pressure, as needed, to maintain airway patency (APAP titration). These adjustments can be made with or without attendant technician intervention. Data obtained during APAP titration can be used to provide a fixed single pressure for subsequent treatment. Alternatively, APAP devices can be used in self-adjusting mode for treatment (APAP treatment). A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine reviewed the available literature. Based on this review, the Standards of Practice Committee developed these practice parameters as a guide to the appropriate use of APAP. Recommendations are as follows: 1) A diagnosis of OSAS must be established by an acceptable method. 2) APAP titration and APAP treatment are not currently recommended for patients with congestive heart failure, significant lung disease (e.g., chronic obstructive pulmonary disease), daytime hypoxemia and respiratory failure from any cause, or prominent nocturnal desaturation other than from OSA (e.g., obesity hypoventilation syndrome). In addition, patients who do not snore (either due to palate surgery or naturally) should not be titrated with an APAP device that relies on vibration or sound in the device's algorithm. 3) APAP devices are not currently recommended for split-night studies since none of the reviewed research studies examined this issue. 4) Certain APAP devices may be used during attended titration to identify by polysomnography a single pressure for use with standard CPAP for treatment of OSA. 5) Once an initial successful attended CPAP or APAP titration has been determined by polysomnography, certain APAP devices may be used in the self-adjusting mode for unattended treatment of patients with OSA. 6) Use of unattended APAP to either initially determine pressures for fixed CPAP or for self-adjusting APAP treatment in CPAP naïve patients is not currently established. 7) Patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must be followed to determine treatment effectiveness and safety, and 8) a re-evaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the CPAP or APAP treatment otherwise appears to lack efficacy.

Equipment Design↗

Insomnia and heart disease: a review of epidemiologic studies.

Since the discovery and successful treatment of sleep apnea, researchers seem to believe that the association between sleep disturbance and coronary heart disease (CHD) has been explained. To determine whether subjective nighttime sleep complaints (trouble sleeping, trouble falling asleep, trouble staying asleep), exclusive of apnea, predicted myocardial infarction and other coronary events, a MEDLINE search was conducted for articles published between January 1976 through August 1997. Ten studies with an explicit measure of association between an insomniac complaint and CHD were identified. Reported risk ratios for various sleep complaints and CHD events ranged from 1.0 for waking too early and CHD death in an elderly North Carolina community to 8.0 for the highest versus lowest quintile of a sleep scale in Finnish men. Higher quality studies showed risk ratios of 1.47-3.90 between trouble falling asleep and coronary events after adjusting for age and various coronary risk factors (combined effect=1.7, p<0.0001). While alternative explanations such as medication use still need to be ruled out, we theorize that a subjective insomniac complaint either may be part of a larger syndrome that includes poor health and depression, or it may be related to continual stressors, reduced slow-wave sleep, and autonomic dysfunction, which increase the risk of heart problems.

Confounding Factors, Epidemiologic↗