Shock wave interaction with laser-generated single bubbles.

The interaction of a lithotripter shock wave (LSW) with laser-generated single vapor bubbles in water is investigated using high-speed photography and pressure measurement via a fiber-optic probe hydrophone. The interaction leads to nonspherical collapse of the bubble with secondary shock wave emission and microjet formation along the LSW propagation direction. The maximum pressure amplification is produced during the collapse phase of the bubble oscillation when the compressive pulse duration of the LSW matches with the forced collapse time of the bubble.

High-Energy Shock Waves↗

Cylindrical ultrasonic transducers for cardiac catheter ablation.

This study was designed to evaluate the feasibility of using cylindrical ultrasound transducers mounted on a catheter for the ablation of cardiac tissues. In addition, the effects of ultrasound frequency and power was evaluated both using computer simulations and in vitro experiments. Frequencies of 4.5, 6, and 10 MHz were selected based on the simulation studies and manufacturing feasibility. These transducers were mounted on the tip of 7-French catheters and applied in vitro to fresh ventricular canine endocardium, submerged in flowing degassed saline at 37 degree C. When the power was regulated to maintain transducer interface temperature at 90-100 degree C, the 10-, 6-, and 4.5-MHz transducers generated a lesion depth of 5.9 +/- 0.2 mm, 4.6 +/- 1.0 mm, and 5.3 +/- 0.9 mm, respectively. The 10-MHz transducer was chosen for the in vivo tests since the maximum lesion depth was achieved with the lowest power. Two dogs were anesthetized and sonications were performed in both the left and right ventricles. The 10-MHz cylindrical transducers caused an average lesion depth of 6.4 +/- 2.5 mm. In conclusion, the results show that cylindrical ultrasound transducers can be used for cardiac tissue ablation and that they may be able to produce deeper tissue necrosis than other methods currently in use.

Animals↗

Comparison of gold versus platinum electrodes on myocardial lesion size using radiofrequency energy.

During radiofrequency (RF) catheter ablation of arrhythmias, temperatures that approach 100 degrees C cause a coagulum to form on the ablation electrode that results in an increase in electrical impedance and prevents further energy delivery. Since gold has nearly four times the thermal conductivity as platinum, the metal commonly used, it was postulated that gold tip electrodes could deliver more power and produce deeper lesions because of its greater heat dissipation from the electrode-tissue interface to the circulating blood. To test this hypothesis, RF energy was applied to fresh bovine ventricular myocardium using 6 French catheters with 2-mm long distal electrodes made from gold or platinum. Similar studies were also conducted using 7 French catheters with 4-mm long distal electrodes. Maximum lesion depth was defined as that produced with the level of energy just below that causing an impedance rise. A maximum lesion depth of 6.2 +/- 0.7 mm (mean +/- SD) was obtained with the gold 2-mm electrode and 4.7 +/- 0.5 mm with the platinum electrode (P = 0.003). The 4-mm gold electrode produced a maximum lesion depth of 7.2 +/- 1.4 mm, while a catheter with a 4-mm platinum electrode caused a maximum lesion depth of 5.8 +/- 0.7 mm (P = 0.05). We conclude that deeper lesions should be able to be made when RF energy is delivered to a gold rather than platinum tip electrode.

Animals↗