Lymphoscintigraphy in the detection of cervical metastases from oral carcinoma: a pilot study.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to W N Tauxe.
Explore the source record for details and available documents.
A case of rhabdomyolysis induced by exertional heat stroke in a police officer recruit is reported. Technetium-99m methylene diphosphonate scintigraphy demonstrated marked uptake of the injured skeletal muscle. This bone-scanning agent provided an excellent means of localizing and evaluating the muscle injury of rhabdomyolysis. Nuclear medicine physicians should be aware of the special conditions and causes in which bone scan may demonstrate striking findings.
A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses of 5 and 20 mg. Of 25 known lesions, 17 were detected (sensitivity, 68%). The smallest detected lesion in the lung was 1 cm and in the liver was 1.5 cm. The serum half-life of In-111-labeled CCR 086 MoAb was approximately 64 hours. The formation of human antimouse antibody (HAMA) was detected in the serum of four of five patients who received 20 mg of MoAb. No HAMAs were detected in four patients receiving 5 mg of MoAb. No side effects were encountered. Because of effective detection of liver and lung metastases with lower doses (5-20 mg) of CCR 086 conjugated with In-111, further investigations are warranted to assess clinical and therapeutic potentials of CCR 086 in the management of colorectal cancer.
Explore the source record for details and available documents.
We studied a patient with an alloantibody to the high-frequency red blood cell (RBC) antigen Gerbich. A nationwide search for rare Gerbich-negative blood (less than 1:45,000 donors) located only seven units, and our supply was quickly exhausted. By using an in vivo cross-matching method, we demonstrated that this anti-Gerbich did not cause RBC destruction. Regular Gerbich-positive transfusions could then proceed without hemolysis. This cross-match test was based on the determination of the urinary excretion rates of injected radioactive chromium-labeled donor erythrocytes by which it was possible to determine compatibility only 24 hr after the test was begun. The procedure provides an easy and accurate means for in vivo cross-matching of conventionally incompatible donor blood.
To distinguish segmental impaction from avascular necrosis of the femoral head, 26 consecutive patients who sustained an acute displaced acetabular fracture were assessed preoperatively with routine radiographs, computed tomography, and radionuclide imaging using pinhole collimation and single photon emission computed tomography (SPECT). The diagnostic criterion for avascular necrosis was a photopenic defect of the femoral head, whereas, the criterion for segmental impaction was an area of impaction of at least 1 cm2 noted at the time of surgery. Of this series, 3 incurred a segmental impaction while 1 showed evidence consistent with avascular necrosis on SPECT imaging. None of the patients possessed diagnostic features of both complications. The distinction between these two complications of an acetabular fracture should contribute to the application of appropriate surgical techniques to correct segmental impaction and avascular necrosis.
Elevated levels of carcinoembryonic antigen (CEA) or calcitonin after surgical therapy for medullary carcinoma of the thyroid gland (MCT) indicate the presence of residual or metastatic disease. CEA elevations appear to be prognostically more reliable in patients with metastatic disease and suggest a more virulent tumor. Attempts to stage the disease with use of conventional imaging techniques are usually inadequate, as is the therapy for disseminated or recurrent MCT. An indium-111-labeled anti-CEA monoclonal antibody (ZCE-025) was used to image metastases in a patient with MCT. Potential applications of monoclonal antibody technology in the management of MCT would include (1) preoperative differentiation of unicentric from multicentric thyroid gland involvement, (2) detection of regional or distant metastases or both, (3) measurement of response to systemic therapy, and (4) the facilitation of radionuclide immunoconjugate therapy.
Various in vitro methods employing radioactive indicators have been presented for the determination of glomerular filtration rate (GFR) including slope/intercept (S/I) and single sample (SS) methods. The S/I technique utilizes the analysis of the slope of a certain segment of the plasma disappearance curve of a suitable radioactive indicator and its intercept on the y axis. The SS method is based on the theoretical volumes of distribution derived from a single plasma concentration at some specific time after intravenous injection of the indicator. Using GFRs estimated from the compartmental analysis of the entire plasma disappearance curve as a reference standard, we have compared the errors of GFR estimation calculated from 12 S/I methods, 3 SS methods and 2 techniques in which original formulae were derived. The errors of the SS method of Tauxe et al. gave the lowest standard error of estimate (Sy X x) of all the methods. The S/I methods gave lowest errors when sampling times were taken between 60 min and 240 min. Almost all the errors observed here were significantly less than those observed using scintillation camera techniques. The SS method seems to be the method of choice for estimation of GFR by single injection techniques. The use of the scintillation camera in conjunction with the SS technique would provide a useful right to left ratio so that individual kidney GFR could be calculated.
A method for the determination of the glomerular filtration rate (GFR) in children which involves the use of a single-plasma sample (SPS) after the injection of a radioactive indicator such as radioiodine labeled diatrizoate (Hypaque) has been developed. This is analogous to previously published SPS techniques of effective renal plasma flow (ERPF) in adults and children and GFR SPS techniques in adults. As a reference standard, GFR has been calculated from compartment analysis of injected radiopharmaceuticals (Sapirstein Method). Theoretical volumes of distribution were calculated at various times after injection (Vt) by dividing the total injected counts (I) by the plasma concentration (Ct) expressed in liters, determined by counting an aliquot of plasma in a well type scintillation counter. Errors of predicting GFR from the various Vt values were determined as the standard error of estimate (Sy.x) in ml/min. They were found to be relatively high early after injection and to fall to a nadir of 3.9 ml/min at 91 min. The Sy.x Vt relationship was examined in linear, quadratic, and exponential form, but the simpler linear relationship was found to yield the lowest error. Other data calculated from the compartment analysis of the reference plasma disappearance curves are presented, but at this time have apparently little clinical relevance.
Measurement of glomerular filtration rate (GFR) based on the radioactivity concentration in a single-plasma sample obtained after the injection of radioiodinated diatrizoate (DTZ) has been described. Simultaneous determinations of GFR by use of DTZ based on multiple-sample plasma disappearance curves and inulin correlate highly. Certain theoretical volumes of distribution (injection dose counts divided by plasma concentration expressed as counts per liter of plasma) correlate highly with GFR determined by the multiple-sample plasma disappearance curves. For patients with relatively high GFR (greater than 100 ml/min) best correlations were obtained at 120 min; for patients with GFR 60-100 ml/min, best correlations were obtained at sampling times of 150 min after injection and for patients with GFR less than 60 ml/min, the ideal sampling time was 230 min after injection. For general use the 180-min sampling time may suffice. Since the formulae were found to produce nearly identical GFR values for data obtained from the use of diethylenetriaminepentaacetic acid and DTZ, the former radiopharmaceutical can probably be substituted for diatrizoate using these formulae and sampling times as long as absence of plasma protein binding of the labeled chelate can be demonstrated.
A variety of methods have been proposed to estimate the glomerular filtration rate (GFR) from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. To compare alternative methods, we calculated the GFR in several different ways from measurements in 33 patients and compared the results with an independent GFR measurement based on eight-point plasma clearance of ytterbium Yb 169-DTPA. The best agreement was obtained using an algorithm that has not been described previously, in which correction was made for overlap of the kidneys by the liver and spleen. The correlation coefficient was 0.958, and the residual standard deviation was 12.1 ml/min. This method required a single 20-min blood sample as well as the camera data. The best method not requiring a blood sample was significantly less accurate, with a correlation coefficient of 0.837 and a residual standard deviation of 23.1 ml/min. The accuracy of these methods was comparable to that reported for creatinine clearance, the most commonly used estimate of the GFR in current clinical practice.
Glomerular filtration rate (GFR) can be calculated from the plasma clearance of any of several radiopharmaceuticals that are excreted by glomerular filtration. Simplified methods have been proposed that require only one or two plasma samples in lieu of a more complete clearance curve. We examined the error introduced by this simplification. Forty patients were studied using a dual-isotope technique employing [99mTc]DTPA and [169Yb]DTPA, obtaining eight plasma samples for each clearance curve at intervals from 10 to 240 min after injection. Data were fit to several empirical or semiempirical formulae and also to a two-compartment computer model that permitted GFR estimation from only one or two data points. The computer model gave good fit, but so did several simpler methods. The error that results from replacing the complete clearance curve by a single 3-hr sample was about 8 ml/min (residual s.d.). By using two samples (at 1 and 3 hr), the error could be reduced to 4 ml/min. Recommended one- and two-sample methods are presented.
The relationship between effective renal plasma flow (ERPF) and cardiac output was examined in 46 patients (22 with congestive heart failure and 24 following cardiac surgical procedures) by simultaneously measuring the global ERPF by the single-injection method and cardiac output by the thermodilution method. Of the patients in the heart-failure group, 21 also had pulmonary artery end diastolic pressure (PAEDP) recorded at the same time. ERPF and cardiac output were found to be related by the regression equation: cardiac output = 2.08 +/- 0.0065 ERPF (r, 0.80), with a SE of estimate of 0.81 l/min. ERPF and PAEDP were related by the regression equation: PAEDP = 45.02-0.0675 ERPF (r, 0.86), with a SE of estimate of 5.5 mm Hg. ERPF may be a useful noninvasive method of estimating cardiac output if it is known that no intrinsic kidney disease is present, and if the error of 0.81 l/min (1 SE of estimate) is within the range of clinical usefulness. The error is principally attributable to the determination of cardiac output by the thermodilution method.
Numerous simplified methods for the estimation of ERPF have described, including the so-called slope/intercept (SI) methods, based on the analysis of the slope of certain segments of the 131I-OIH plasma disappearance curve and its y-axis intercept, and the single sample (SS) clearance method, based on theoretical volumes of OIH distribution at some fixed time after injection. Using ERPFs estimated from compartment analysis of the entire 60-min plasma disappearance curve, we have compared the errors of data calculated from use of eight SI methods made at various times along the disappearance curve with that from the optimum SS curve. The errors obtained from the SS method were approximately 50% less than those obtained from the SI methods. The errors of the SI methods are greater at both ends of the 60-min plasma curve than when samples are drawn near the mid-time. The SS method appears to be the method of choice for the estimation of ERPF using single injection techniques.
Radionuclide assessment of ejection fraction was determined early and late postoperatively following cardiac transplantation in 16 patients. In 11 patients, ejection fraction was determined within 48 hours of an endocardial biopsy. There was no relationship between the severity of histologically evident rejection and the ejection fraction (Pearson correlation coefficient [r] = -0.11; p = 0.47). In 2 patients, severe graft fibrosis developed with consequent diminution in ejection fraction. There was no relationship between severity and duration of rejection or the amount of immunosuppression required to treat acute rejection and the development of graft fibrosis. The mean resting ejection fraction in 7 patients in follow-up ranging from 6 to 21 months after transplantation was 0.59 +/- 0.06 (standard deviation), and the mean exercise ejection fraction in 6 of these patients was 0.72 +/- 0.08. Radionuclide-determined ejection fraction is not predictive of rejection early after operation. During short-term late follow-up, systolic left ventricular function at rest and exercise has been retained at normal levels.
Computer-assisted renal scintigraphy was performed on 160 acute and 240 chronic spinal cord injury patients, and 287 noninjured controls. Concurrently, measurements of global and individual kidney effective renal plasma flow, time of maximum activity in each kidney, ratio of maximum counts to the counts at 27 minutes after injection over each kidney and number of counts in each kidney at 1 to 2 minutes after injection were made. The time of peak activity over the kidney and differential function at 1 to 2 minutes after injection were not affected significantly by age, sex or spinal cord status. Global and individual effective renal plasma flows were significantly affected by all of these factors. Both plasma flow measures generally were higher for male than for female patients. Effective renal plasma flow decreased steadily after early adulthood and, except for the youngest and oldest patients, values were lower for spinal cord injury patients than for normal controls. The ratio of peak to 27-minute counts was affected significantly by age and spinal cord injury but not by sex. In patients without obvious pathological conditions followup scintigrams 1 to 3 years after injury showed no significant changes owing to interval since injury on any parameter studied. Lower limits of basal scintigraphic parameters are given for evaluation of renal status in neurologically intact or spinal cord injury persons.
Algorithms for the estimation of organ volumes have been developed which may provide whole organ volumes and which may or may not, at the operator's choice, take into account any voids which may be contained within the organ. These algorithms have been applied to the estimation of the volume of the kidneys, in normal subjects and in patients with renal disease. The dimensions of the kidneys were similar to those derived from ultrasound study measurements which were performed independently. Kidney volume should prove especially useful in the diagnosis of early graft rejection and in the diagnosis of glomerulonephritis.
A case of severe urinary extravasation after renal pyeloplasty resulted in symptoms strongly suggestive of musculoskeletal origin. Bone scintigraphy revealed no findings relating to the skeletal system, but because of renal excretion of the tracer, the cause of the postoperative pain was revealed. The value of bone scintigraphy as a urinary tract diagnostic screening tool is probably underrated, even though at least 15% of studies fortuitously detect abnormalities of the urinary tract.