A new retractor system for thoracoscopic thymectomy using the anterior chest wall-lifting method.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to W R Chitwood.
Explore the source record for details and available documents.
BACKGROUND: In robotic surgery, the ideal position of the system, as well as the optimal working angles and the proper positioning of the thoraco ports position is very important. No robot-assisted bronchoplasty has been reported. Our study describes use of the da VinciTM surgical system (Intuitive Surgical, Inc.) for robotic sleeve upper lobectomy in a human fresh cadaver. METHODS: A male cadaver was placed in the left lateral decubitus position. After thoracoscopic upper lobectomy was performed through the working port and the two ports, the robotic system was then set up behind the cadaver. The working port allowed introduction of the optical scope and the robotic surgical arms were inserted into the thoraco ports. The right bronchus was dissected and wedge was cut out with the robotic scissors. After standard lymph node dissection, end-to-end bronchial anastomosis was performed with robotic instruments. Once the anastomosis was complete, air leakage was checked with saline solution placed in the pleural cavity. RESULTS: Thoracoscopic robot-assisted bronchoplasty was performed successfully. CONCLUSIONS: In evaluating various positions of the system we demonstrated that our technique is sufficient approaches to robotic bronchoplasty. This procedure offers specific advantages over conventional bronchoplasty with accuracy and safety.
OBJECTIVE: In a prospective phase II Food and Drug Administration trial, robotic mitral valve repairs were performed in 112 patients at 10 centers by using the da Vinci surgical system. The safety of performing valve repairs with computerized telemanipulation was studied. METHODS: After institutional review board approval, informed consent was obtained. Patients had moderate to severe mitral regurgitation. Operative technique included peripheral cardiopulmonary bypass, a 4- to 5-cm right minithoracotomy, a transthoracic aortic crossclamp, and antegrade cardioplegia. The successful study end point was grade 0 or 1 mitral regurgitation by transthoracic echocardiography at 1 month after surgery. RESULTS: Valve repairs included quadrangular resections, sliding plasties, edge-to-edge approximations, and both chordal transfers and replacements. The average age was 56.4 +/- 0.09 years (mean +/- SEM). There were 77 (68.8%) men and 35 (31.2%) women. Valve pathology was myxomatous degeneration in 105 (91.1%), and 103 (92.0%) had type II leaflet prolapse. Leaflet repair times averaged 36.7 +/- 0.2 minutes, with annuloplasty times of 39.6 +/- 0.1 minutes. Total robot, aortic crossclamp, and cardiopulmonary bypass times were 77.9 +/- 0.3 minutes, 2.1 +/- 0.1 hours, and 2.8 +/- 0.1 hours, respectively. On 1-month transthoracic echocardiography, 9 (8.0%) had grade 2 mitral regurgitation, and 6 (5.4%) of these had reoperations (5 replacements and 1 repair). There were no deaths, strokes, or device-related complications. CONCLUSIONS: Multiple surgical teams performed robotic mitral valve repairs safely early in development of this procedure, with a reoperation rate of 5.4%. Advancements in robotic design and adjunctive technologies may help in the evolution of this minimally invasive technique by decreasing operative times.
BACKGROUND: Our study evaluates a series of video-assisted minimally invasive mitral operations, showing safe progression toward totally endoscopic techniques. METHODS: Consecutive patients with isolated mitral valve disease underwent either manually directed (n = 55) or voice-activated robotically directed (n = 72) video-assisted mitral operations. Cold blood cardioplegia, a transthoracic aortic clamp, a 5-mm endoscope, and a 5-cm minithoracotomy were used. This video-assisted minimally invasive mitral operation cohort was compared with a previous sternotomy-based mitral operation cohort (n = 100). RESULTS: Group demographics, New York Heart Association classification, and cardiac function were similar. Repairs were performed in 61.8% manually directed (n = 34), 75.0% robotically directed (n = 54), and 54% sternotomy-based (N = 54) mitral operations. The robotically directed technique showed a significant decrease in blood loss, ventilator time, and hospitalization compared with the sternotomy-based technique. Manually directed mitral operations compared with robotically directed mitral operations had decreased arrest times (128.0 +/- 4.5 minutes compared with 90.0 +/- 4.6 minutes; p < 0.001) and decreased perfusion times (173.0 +/- 5.7 minutes compared with 144.0 +/- 4.6 minutes; p < 0.001). In the minimally invasive mitral operation cohort, complications included reexploration for bleeding (2.4%; n = 3) and one stroke (0.8%), whereas the 30-day mortality was 2.3% (n = 3). CONCLUSIONS: Video-assisted mitral surgery provides safe and effective results when compared with conventional sternal approaches. These positive results show a safe and stepwise evolution toward a totally endoscopic mitral valve operation.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The first robotic Nissen fundoplication using the da Vinci robotic surgical system was performed on a 56-year-old woman with a 20-year history of severe gastroesophageal reflux disease refractory to medical management. The recovery was uneventful, and follow-up continues.
OBJECTIVE: To detail robotic procedure development and clinical applications for mitral valve, biliary, and gastric reflux operations, and to implement a multispecialty robotic surgery training curriculum for both surgeons and surgical teams. SUMMARY BACKGROUND DATA: Remote, accurate telemanipulation of intracavitary instruments by general and cardiac surgeons is now possible. Complex technologic advancements in surgical robotics require well-designed training programs. Moreover, efficient robotic surgical procedures must be developed methodically and safely implemented clinically. METHODS: Advanced training on robotic systems provides surgeon confidence when operating in tiny intracavitary spaces. Three-dimensional vision and articulated instrument control are essential. The authors' two da Vinci robotic systems have been dedicated to procedure development, clinical surgery, and training of surgical specialists. Their center has been the first United States site to train surgeons formally in clinical robotics. RESULTS: Established surgeons and residents have been trained using a defined robotic surgical educational curriculum. Also, 30 multispecialty teams have been trained in robotic mechanics and electronics. Initially, robotic procedures were developed experimentally and are described. In the past year the authors have performed 52 robotic-assisted clinical operations: 18 mitral valve repairs, 20 cholecystectomies, and 14 Nissen fundoplications. These respective operations required 108, 28, and 73 minutes of robotic telemanipulation to complete. Procedure times for the last half of the abdominal operations decreased significantly, as did the knot-tying time in mitral operations. There have been no deaths and few complications. One mitral patient had postoperative bleeding. CONCLUSION: Robotic surgery can be performed safely with excellent results. The authors have developed an effective curriculum for training teams in robotic surgery. After training, surgeons have applied these methods effectively and safely.
"The man with a new idea is a crank until the idea succeeds."--Mark Twain. With the profound public stress for minimally invasive surgery that guided General Surgery, Cardiothoracic Surgery has progressed with warranted enthusiasm. The explosion of technological advancements in optics, instrumentation and cardiopulmonary bypass has permitted minimally invasive cardiac procedures to be performed with safety, efficiency, and efficacy. In this chapter, we review the evolution of minimally invasive cardiac valve surgery. The articles of leading minimally invasive valve surgeons, both European and American, are reviewed. The indications for minimally invasive surgery are explained. Furthermore, the present day state of "robotic" mitral valve surgery is described.
BACKGROUND: Beating heart or "off-pump" coronary artery bypass (OP-CAB) has become an accepted method of myocardial revascularization by reducing the perioperative morbidity related to cardiopulmonary bypass (CPB). However, the efficacy of OP-CAB has not been well established in the elderly patient population. METHODS: OP-CABs were performed in 53 patients aged 75 years and older, at Pitt County Memorial Hospital from January 1996 to October 1999, either through a median sternotomy or an anterior thoracotomy. These results were compared with 220 patients who underwent standard coronary artery bypass graft (CABG) operation using CPB during the same time period. RESULTS: Mean patient age for both groups was 79+/-0.5 years and preoperative risk factors were similar. There were no differences in postoperative myocardial infarction, atrial fibrillation, bleeding, neurologic complications, or renal failure. There were no deaths after OP-CAB, compared with the 7.6% operative mortality rate after CABG (p<0.05). The OP-CAB group had a significantly shorter postoperative length of stay (4.4+/-0.4 days vs. 8.4+/-0.6 days) and lower transfusion requirements (0.4+/-0.1 units packed red blood cells vs 1.9+/-0.2 units packed red blood cells) than the CABG group. CONCLUSIONS: Our data demonstrate that OP-CAB is a safe and efficacious method of myocardial revascularization in the elderly, and may actually be preferential in these patients when applicable.
BACKGROUND: The minimally invasive anterior thoracotomy for beating heart coronary bypass offers a modest 10-cm incision and avoids the morbidity of extracorporeal circulation. This study examines minimally invasive direct coronary artery bypass (MIDCAB) wound complications and contributing comorbid factors. METHODS: A retrospective, single-institution review of 165 consecutive MIDCAB cases performed between March 1996 and August 1999 examined all wound abnormalities. Two surgeons performed all cases. RESULTS: Wound complications occurred in 15 patients (9.1%), including three (1.8%) incisional hernias, four (2.4%) superficial dehiscences, three (1.8%) wound infections, three (1.8%) chronic pain syndromes, and two (1.2%) seromas. Two patients with incisional hernias required operative repair. The remaining wound abnormalities responded to conservative therapy. Two chronic pain syndrome cases resolved spontaneously, but the third required advanced pain management. In contrast to MIDCAB, the sternotomy wound complications proved significantly less prevalent (n = 5259, 1.1% vs 9.1%, p < 0.005). CONCLUSIONS: Although MIDCAB offers several advantages over standard approaches, these data suggest that anterior thoracotomy wound complications are not insignificant and may be underestimated by those exploring minimally invasive options.
BACKGROUND: Recent clinical use of vascular endothelial growth factor (VEGF) in the treatment of both myocardial and peripheral ischemia has suggested the possibility of tissue specific coregulation of VEGF and its receptors (eg, kinase domain region [KDR]). The present study was performed to detect the relationship between VEGF and KDR protein levels after acute myocardial and peripheral ischemia. METHODS: Eleven dogs were divided into two groups: peripheral ischemia (n = 6, ligation of major limb arteries) and myocardial ischemia (n = 5, circumflex artery ligation). Muscle biopsy specimens were taken from the perfusion territories of the occluded circumflex artery and limb arteries 3 hours and 6 hours after ligation. Protein levels were determined using Western blot analysis. RESULTS: In myocardium, VEGF levels increased on average eightfold from baseline (p < 0.05) both 3 hours and 6 hours after occlusion, whereas myocardial KDR levels dropped by about 60% at 3 hours and 80% at 6 hours (p < 0.05). With limb ischemia, both VEGF and KDR levels were significantly elevated at 3 hours. CONCLUSIONS: In acute ischemia, regulation of VEGF and KDR may be controlled differently in cardiac and skeletal muscle. Myocardial KDR levels showed a significant decrease from baseline compared with a significant rise with peripheral ischemia.
Explore the source record for details and available documents.
BACKGROUND: Controversy exists as to whether off-pump CABG with local occlusion results in clinically significant myocardial ischemia during the occlusion period. This study was undertaken to delineate the effects of transient local coronary artery occlusion on regional systolic function. METHODS AND RESULTS: Eight consenting patients undergoing left internal mammary to left anterior descending coronary artery (LAD) bypass were instrumented with a left ventricular pressure catheter and 2 subepicardial cylindrical ultrasonic dimension transducers placed in the minor axis dimension in the region served by the LAD. A digital sonomicrometer was used to collect data before, during, and after coronary occlusion from which percent systolic shortening and pressure-dimension loops were derived. Measuring devices were removed immediately after the final time point. All patients tolerated the procedure well, and there were no complications. Average duration of local occlusion needed for CABG was 15.9+/-4.4 minutes (range, 12 to 26 minutes). Local occlusion was associated with a decrease in peak systolic shortening from 5.8+/-0.8% to 1.8+/-0.8%. In all cases, function returned to baseline after restoration of flow. Pressure-dimension loops confirmed these findings and no evidence of diastolic creep. Linear repression analysis of degree of stenosis versus change in segmental shortening revealed a significant inverse correlation. CONCLUSIONS: Local occlusion of the LAD resulted in a transient decrease in myocardial function during occlusion with complete recovery during reperfusion. This change was less significant with increasing degrees of coronary stenosis. These data suggest that local occlusion is not associated with permanent myocardial injury but that ischemic changes do occur that may be clinically significant, especially in patients with lesser degrees of coronary stenosis.
BACKGROUND: Minimally invasive heart operation differs from traditional cardiac operations through the omission of a sternotomy, cardiopulmonary bypass, or both. Current concerns with minimally invasive operation include: operative safety, learning curve, operative times, arrest times, and adequacy of myocardial protection. While many of the protective strategies used for traditional procedures may be applied to minimally invasive cardiac operations, the safe applications of minimally invasive operations require unique techniques of myocardial protection. METHODS AND RESULTS: Omission of extracorporeal perfusion may benefit patients through attenuation of systemic inflammatory response, decrement in neurologic insults, and reduced bleeding complications. As a counterbalance, surgeons must consider long-term operative quality and level of myocardial protection provided during beating heart coronary operation. Current issues that must be addressed include: pharmacologic management, coronary collateralization and ischemic preconditioning, the utility of intraluminal coronary shunts, and technical adequacy of the anastomosis. Nonsternotomy cardiopulmonary bypass methods utilize alternative incisions and "port-access" technology, and may render more rapid patient recovery including: decreased pain, shortened hospital stay, and more rapid return to work. Altered strategies of myocardial protection in a closed chest environment must address: method of cannulation, technique of aortic occlusion, rapidity and maintenance of cardiac arrest, and cardiac de-airing techniques. CONCLUSIONS: Previous obstacles to minimally invasive cardiac operations included limitations in operative exposure, inadequate perfusion technology, and inability to provide myocardial protection. Recent advances in videoscopic visualization and evolving mechanisms of myocardial protection may justify the expanding application of minimally invasive techniques.
Explore the source record for details and available documents.
Our group at East Carolina University recently has shown the efficacy of new video-assisted mitral valve surgery. Moreover, we review the evolution and predict the future of endoscopic and robotic-enabling technology for cardiac valve surgery. Herein, a video-assisted mitral valve operation is described and early results are discussed. Cardiopulmonary bypass was established via the femoral vessels, and blood cardioplegic arrest was induced by using a new percutaneous, transthoracic cross-clamp. A 6-cm minithoracotomy was used in each patient. Videoscopy was helpful for suture placement, chord reconstruction, leaflet resection, knot tying, and valve ring or prosthesis positioning. Thus far, 85 patients have undergone this surgery successfully with a 1.2% surgical mortality rate. Our early study with cost data is reviewed in detail. Cardiopulmonary perfusion times and cross-clamp periods for the entire group have been longer than for conventional sternotomy patients at 167 +/- 4.6 minutes and 120 +/- 4.0 minutes, respectively, but complications have been less. Complex repairs and replacements were possible. Bleeding, ventilatory times, and hospital lengths of stay have been reduced. One patient required a second surgery for a failed repair. Recently, we have used voice-activated, robotic assistance for camera control in 28 patients. This has decreased camera motion artifact and lens cleaning while providing direct cerebral-eye tracking of instruments by the surgeon. From this and other studies we reviewed, we conclude that video-assisted and computer-assisted robotic techniques are safe and may be the pathway to truly endoscopic mitral valve surgery.
The aim of the study was to develop a computer-enhanced, video-assisted approach for mitral valve repair as a potential step toward a complete endoscopic procedure. In 10 patients with nonischemic mitral valve insufficiency, computer-enhanced telemetric mitral valve repair using the Intuitive surgical telemanipulation system was performed. A femorofemoral bypass was initiated using Port-Access (Heartport, Redwood City, CA) cannulation. A small minithoracotomy was made in the right 4th intercostal space, and a custom-made rib retractor was placed. The pericardium was opened manually, and four traction stay sutures were placed to enhance exposure. After endoaortic balloon clamping, the left atrium was opened and stabilized. The end-effectors were placed in the left atrium through two ports (3rd ICS and 6th ICS, midaxillary line). A 30 degrees three-dimensional (3D)-videoscope angled up was placed through the incision. Mitral valve repair was then performed remotely from the surgical console. This included inspection of the valve, leaflet resection, leaflet repair, and ring implantation. After completion of the repair and testing of the valve, the end effectors were withdrawn, and the left atrium was closed manually using standard endoscopic instruments (Heartport). In all but 1 patient, successful repair, including quadrangular resection, chordal shortening, Whooler-plasty, and Alfieri-plasty, could be accomplished using the computer-enhanced telemanipulation system. A partial ring was implanted in 6 patients and a complete ring was implanted in 3 patients, respectively. Time for surgery, CPB, and clamp time were 170 to 330 minutes (median, 185 minutes), 140 to 220 minutes (median, 149 minutes), and 78 to 133 minutes (median, 94 minutes), respectively. In one patient, intraoperative transesophageal echocardiography (TEE) showed insufficient repair, a second surgery was performed via an enlarged left thoracotomy. One patient with recurrent mitral insufficiency had to have a second surgery on postoperative day 3 for a torn-out ring. Median time of hospitalization was 8 days. At 3 months follow-up (completed in 7 patients), all patients had improved clinically. Computer-enhanced mitral valve repair is feasible and can be performed with good functional results. The telemanipulation system offers the potential for true endoscopic mitral valve repair. However, surgical time is prolonged, and a learning curve has to be overcome.