PubMed Health⌕ Search

Biomedical subjects

W R Matson

Publications and source records attributed to W R Matson.

29 records · Page 2Linked to original sources

Kynurenine pathway measurements in Huntington's disease striatum: evidence for reduced formation of kynurenic acid.

Recent evidence suggests that there may be overactivation of the N-methyl-D-aspartate (NMDA) subtype of excitatory amino acid receptors in Huntington's disease (HD). Tryptophan metabolism by the kynurenine pathway produces both quinolinic acid, an NMDA receptor agonist, and kynurenic acid, an NMDA receptor antagonist. In the present study, multiple components of the tyrosine and tryptophan metabolic pathways were quantified in postmortem putamen of 35 control and 30 HD patients, using HPLC with 16-sensor electrochemical detection. Consistent with previous reports in HD putamen, there were significant increases in 5-hydroxyindoleacetic acid, 5-hydroxytryptophan, and serotonin concentrations. Within the kynurenine pathway, the ratio of kynurenine to kynurenic acid was significantly (p less than 0.01) increased twofold in HD patients as compared with controls, consistent with reduced formation of kynurenic acid in HD. CSF concentrations of kynurenic acid were significantly reduced in HD patients as compared with controls and patients with other neurologic diseases. Because kynurenic acid is an endogenous inhibitor of excitatory neurotransmission and can block excitotoxic degeneration in vivo, a relative deficiency of this compound could directly contribute to neuronal degeneration in HD.

Aged↗

Cerebrospinal fluid constituents of cat vary with susceptibility to motion sickness.

Six female cats, varying in susceptibility to motion sickness, were implanted with chronic cannulae in the rostral portion of the fourth ventricle. The cats were then challenged with a motion sickness-inducing stimulus. Samples of cerebrospinal fluid were withdrawn before and after emesis or 30 min of motion if emesis did not occur and again on control (no motion) days. The samples were analyzed by HPLC with an array of 16 coulometric detectors. Thirty-six compounds were identified in the samples. Baseline levels of DOPAC, MHPGSO4, uric acid, DA, 5-HIAA and HVA were lower on motion and control days in cats which became motion sick when compared with cats which did not become motion sick. None of the identified compounds varied as a function of either exposure to motion or provocation of emesis. It is concluded that susceptibility to motion sickness is a manifestation of individual differences related to fundamental neurochemical composition.

Animals↗

EC array sensor concepts and data.

The use of multiple parameter assays of entire metabolic pathways is potentially a powerful tool for unraveling mechanisms of disorders or drug action and classification of neurological diseases. Coulometric electrode series array sensors, coupled with liquid chromatography (n-ELC), provide a route to multiplying the resolving power of conventional LC by factors of 10 to 50. Since the original description of the n-ELC concept by Matson et al. (1), fundamental issues of optimizing sensor design and integration with computer controlled LC systems have been addressed. Femtogram level potential time (ET) separations can now be performed for multiple components in both isocratic and gradient modes. A 56-component isocratic method for the study of the kynurenine system in Huntington's Disease (HD) is presented as an indication of the analytical definitions and nomenclature used to qualify an n-ELC procedure, and an indication of the implications of multiparameter data bases on data handling and experimental design.

Amino Acids↗

Serotoninergic system in dementia of the Alzheimer type. Abnormal forms of 5-hydroxytryptophan and serotonin in cerebrospinal fluid.

Serotonin (5-HT), its precursor 5-hydroxytryptophan (5-HTP), and its major metabolite 5-hydroxyindoleacetic acid (5-HIAA) were measured in the cerebrospinal fluid (CSF) of 14 patients with dementia of the Alzheimer type (DAT) and in nine controls by high-performance liquid chromatography with a novel multisensor coulometric detection system. Concentrations of both 5-HT and 5-HIAA detected by this system were lower than the concentrations obtained using conventional amperometric detection. This difference was caused by coelution of compounds that could be resolved from 5-HT and 5-HIAA by the multisensor coulometric system. One of the coelution compounds, observed in DAT but not in control CSF, behaved like a partially oxidized 5-HT. A compound behaving like partially oxidized 5-HTP was also observed in DAT CSF. Concentrations of 5-HTP, 5-HT, and 5-HIAA were lower in DAT CSF than in a corresponding fraction of control CSF. These results indicate involvement of the serotoninergic system in DAT and might lead to development of a diagnostic test for DAT.

5-Hydroxytryptophan↗

n-Electrode three-dimensional liquid chromatography with electrochemical detection for determination of neurotransmitters.

Coulometric electrodes in series have been used with liquid chromatography with electrochemical detection to increase selectivity and resolution for the direct analysis of tissue neurotransmitters. Use of three coulometric sensors for electrochemical modification, selectivity, and peak identification has been expanded into "gate" cells of three or four coulometric electrodes that allow elimination of all electrochemically irreversible substances, and "array" cells of up to 15 coulometric electrodes for separation of co-eluting compounds by their current/voltage characteristics. On-column sensitivity of the sensor arrays is 0.4 to 4 pg. Gate cell selectivity favors electrochemically reversible compounds over irreversible ones, e.g., 3-methoxy-4-hydroxyphenylglycol vs ascorbate, by a factor of up to 10(4). Resolution across the multi-electrode array cells allows separation of co-eluting compounds with half-wave potentials differing by as little as 30 to 40 mV. Cells with three to 15 electrodes have been used to measure monoamines and metabolites in brain; monoamines directly in serum filtrate; and the state of oxidation of 5-hydroxytryptamine and 5-hydroxytryptophan in cerebrospinal fluid of patients with Alzheimer's disease.

5-Hydroxytryptophan↗

Rapid direct determination of lead in evaporated milk by anodic stripping voltammetry without sample pretreatment.

The method presented describes the direct determination of lead in evaporated milk in which the milk ashing step prior to analysis is eliminated. Digital instrument readout units are microgram Pb/mL milk. Total analysis time after instrument calibration is less than 3 min per sample. Range of the method is 0.05-1.0 ppm lead in milk, and precision of the method expressed by relative standard deviation of duplicate pairs ranged from 30% at 0.1 micrograms/mL to 3% at 1.0 micrograms/mL of lead in milk. The method compares favorably with the AOAC official first action anodic stripping voltammetric method (25.074). In addition, the method appears to work equally well for skim evaporated milk, sweetened condensed milk, and nonfat powdered dry milk when the latter two are reconstituted with water according to product label instructions. Recovery and interference studies are presented.

Animals↗

Direct determination of lead in evaporated milk and apple juice by anodic stripping voltammetry: collaborative study.

A method for the direct determination of lead in evaporated milk and in fruit juice with no prior sample digestion was successfully collaborated by 13 laboratories. The anodic stripping voltammetric (ASV) method studied consisted of adding 0.2 mL aliquots of evaporated milk or 0.3 mL aliquots of fruit juice to 2.9 mL of a dechelating reagent, Metexchange. The reagent-sample mixture is then analyzed for lead by ASV with no further sample preparation. Each collaborator received 24 samples, 2 each at 5 different levels (0.07-0.70 ppm for spiked evaporated milk and 0.09-0.87 ppm for spiked apple juice) along with duplicate practice samples of labeled lead content at each of 2 levels for each sample type. All unknowns were coded with random numbers. Approximately 69% of the reporting laboratories had never analyzed either evaporated milk or fruit juice for lead. Average time between receipt of samples and reporting of results was 1.6 days for all laboratories. The pooled variations between duplicate determinations for apple juice and evaporated milk were 0.00059 and 0.00043, respectively. The method was adopted official first action for both fruit juice and evaporated milk.

Animals↗

Analysis of total arsenic in urine and blood by high speed anodic stripping voltammetry.

A method for the measurement of parts per billion levels of total arsenic in urine and blood is described. Samples are wet ashed with a mixture of HNO3, HCIO4, and H2SO4 acids. Ashed materials are subjected to a reductillationTM procedure to reduce As (V) to As (III) and to separate arsenic from the sample matrix. Collected arsenic is then quantitated by anodic stripping voltammetry (ASV) at a gold film electrode. ASV analysis time is only 2 minutes. By simultaneous reductillation of 4 samples, ppb arsenic determinations can be accomplished at a rate of about 12 per hour. The method is as accurate, precise and reliable at the nanogram level as the more universally accepted colorimetric techniques are at the microgram and milligram levels. For replicate analysis of real samples, method precision ranged from +/- 1.4 ppb at the 5 ppb level to +/- 0.96 ppb at the 25 ppb level. Accuracy is estimated at +/- 6% over the range 5 to 500 ppb arsenic.

Arsenic↗

Direct analysis of lead in fruit juice by anodic stripping voltammetry with no prior sample preparation.

A method is presented for determining lead in fruit juice in less than 3 min after instrument calibration. The range examined is 0.01 to 1.3 ppm lead. The method is compared with 3 other methods in general use. Standard error of estimates between the methods compared range from 0.023 to 0.051 ppm for a set of 50 samples and from 0.037 to 0.091 ppm for a set of 9 samples. Regression correlation coefficients between methods range from 0.968 to 0.995. Judged by the comparisons, the direct method is precise and accurate over greater than a 100-fold range of lead concentrations.

Beverages↗