PubMed Health⌕ Search

Biomedical subjects

W S Berg

Publications and source records attributed to W S Berg.

3 recordsLinked to original sources

Transpedicular screw fixation.

Spinal fixation employing transpedicular screws has recently been the focus of increased attention at various institutions throughout the world, but concerns about the safety and efficacy of transpedicular screws linger. This study was undertaken to address some of these concerns. The study included evaluation of the internal and external morphology of the vertebral pedicles, which revealed that adequate bone stock is generally available at T2, T7, T12, and L1-L5 spinal levels to accept screws in the 4-7-mm diameter range. The pedicle was observed to be composed of abundant cancellous bone internally with relatively thick cortical walls. The method of pilot hole preparation for pedicle screws was also examined. Screws inserted in pilot holes prepared with a 3.4-mm blunt probe (ganglion knife) resulted in higher pullout forces in eight of 10 trials as compared with those with pilot holes prepared using a 3.2-mm drill. Furthermore, the probes afford greater control of hole depth and alignment. Fatigue studies on three screw designs revealed a graduation of strength between a 7.0-mm pedicle screw, a 5.5-mm pedicle screw, and a modified 6.5-mm cancellous lag screw. The modified cancellous lag screw has an inherent stress riser that affected fatigue life. It was noted that extreme care must be exercised to prevent bending of the pedicle screws during implantation. If bending occurs one can expect a 50% reduction in the number of cycles to failure.

Bone Screws↗

Evaluation of Dacron-covered and plain bovine xenografts as replacements for the anterior cruciate ligament.

Surgical repair of the anterior cruciate ligament often involves the use of a suitable autograft. As alternatives to sacrificing these normal structures, various allografts, xenografts, and synthetic materials have been investigated as ligament replacement materials. This study investigates Dacron fabric-covered and plain bovine xenograft tendon as such materials in the canine knee. The implants were tested to failure in an MTS machine following 13 weeks of implantation in a canine knee. Dacron woven fabric-covered implants became more firmly attached than those covered by Dacron mesh fabric or plain xenografts. The implants were also analyzed according to their method of attachment (fixation staples or sutures). Overall, the sutured implants failed at slightly higher forces than did the stapled ones. Histologically, limited vascular invasion of the xenograft was observed. No host fibrous or osseous tissue could be identified within the graft. Fibrous tissues did form between the bone and xenograft. The implants exhibited extreme intraarticular wear, which suggests a low potential for intraarticular ligament replacement.

Animals↗

A morphometric study of human lumbar and selected thoracic vertebrae.

The results of a morphometric study of selected human vertebrae undertaken to provide data for implant design are presented in this report. Twenty-seven dimensions were measured from thoracic (T2, T7, T12) and lumbar (L1-L5) vertebrae using prepared spinal columns from 30 skeletons belonging to the Hamann-Todd Osteological Collection. Maximum and minimum pedicle dimensions indicated that the pedicles are less symmetric cephalad than they are caudal. Vertebral body height increases caudally except posteriorly where, after an initial increase, it decreases in the lower lumbar region. Major and minor body diameters and the major spinal canal diameter slightly increase caudally, whereas minor spinal canal diameter exhibits little or no change.

Female↗