PubMed Health⌕ Search

Biomedical subjects

W S Ellis

Publications and source records attributed to W S Ellis.

14 recordsLinked to original sources

Body surface mapping of counterclockwise and clockwise typical atrial flutter: a comparative analysis with endocardial activation sequence mapping.

OBJECTIVES: This study was directed at developing spatial 62-lead electrocardiogram (ECG) criteria for classification of counterclockwise (CCW) and clockwise (CW) typical atrial flutter (Fl) in patients with and without structural heart disease. BACKGROUND: Electrocardiographic classification of CCW and CW typical atrial Fl is frequently hampered by inaccurate and inconclusive scalar waveform analysis of the 12-lead ECG. METHODS: Electrocardiogram signals from 62 torso sites and multisite endocardial recordings were obtained during CCW typical atrial Fl (12 patients), CW typical Fl (3 patients), both forms of typical Fl (4 patients) and CCW typical and atypical atrial Fl (1 patient). All the Fl wave episodes were divided into two or three successive time periods showing stable potential distributions from which integral maps were computed. RESULTS: The initial, intermediate and terminal CCW Fl wave map patterns coincided with: 1) caudocranial activation of the right atrial septum and proximal-to-distal coronary sinus activation, 2) craniocaudal activation of the right atrial free wall, and 3) activation of the lateral part of the subeustachian isthmus, respectively. The initial, intermediate and terminal CW Fl wave map patterns corresponded with : 1) craniocaudal right atrial septal activation, 2) activation of the subeustachian isthmus and proximal-to-distal coronary sinus activation, and 3) caudocranial right atrial free wall activation, respectively. A reference set of typical CCW and CW mean integral maps of the three successive Fl wave periods was computed after establishing a high degree of quantitative interpatient integral map pattern correspondence irrespective of the presence or absence of organic heart disease. CONCLUSIONS: The 62-lead ECG of CCW and CW typical atrial Fl in man is characterized by a stereotypical spatial voltage distribution that can be directly related to the underlying activation sequence and is highly specific to the direction of Fl wave rotation. The mean CCW and CW Fl wave integral maps present a unique reference set for improved clinical detection and classification of typical atrial Fl.

Aged↗

The role of the crista terminalis in atrial flutter and fibrillation: a computer modeling study.

Although atrial fibrillation is a common arrhythmia, the underlying mechanisms are incompletely understood. Recent studies have determined the role of the crista terminalis in the mechanisms of a simpler arrhythmia, atrial flutter. We hypothesize that as transverse coupling across the crista terminalis increases, the activation pattern that results is less like typical atrial flutter and more like atrial fibrillation. 6480 Van Capelle elements were coupled in an icosahedron, simulating the right atrium. Atrial simulations were created which incorporated no heterogeneity, heterogeneous coupling, heterogeneous effective refractory periods, and both heterogeneous coupling and effective refractory periods. When the entire crista terminalis was uncoupled, typical atrial flutter occurred. When transverse coupling allowed activation to propagate across the crista terminalis, the flutter cycle length decreased (p<0.0001). In addition, when heterogeneity was present, both the coefficient of variation of cycle length and the number of activation wavelets increased (p<0.0001). Thus, a more rapid reentrant circuit in the superior right atrium drove fibrillatory activity in the remainder of the atrium, as predicted by the "mother wavelet hypothesis." While awaiting in vivo validation, our study indicates that transverse coupling along the crista terminalis may play an important role in the development of atrial fibrillation from atrial flutter.

Atrial Fibrillation↗

Organized activation during atrial fibrillation in man: endocardial and electrocardiographic manifestations.

INTRODUCTION: Atrial fibrillation is not entirely random, but little is known about the spatiotemporal endocardial organization and its surface ECG manifestations. METHODS AND RESULTS: In 16 patients with atrial fibrillation (chronic, n = 14), endocardial mapping of the trabeculated, the posteroseptal smooth right atrium, and the coronary sinus was performed using multipolar catheters. The surface ECG was analyzed by determining "fibrillation wave" (F wave) amplitude, rate, and polarity. During 50 minutes of atrial fibrillation, an organized activation was present 72% +/- 32% of the analyzed time on the trabeculated, 19% +/- 15% on the smooth right atrium (P < 0.01), and 51% +/- 33% along the coronary sinus (P < 0.05). The direction of organized activation was craniocaudal in 72% +/- 16%, caudocranial in 10% +/- 9% (P < 0.01), and indeterminable in 18% +/- 11%. The mean surface F wave amplitude in lead V1 was 0.128 +/- 0.06 mV during 28 seconds of atrial fibrillation with a craniocaudal direction of activation and 0.065 +/- 0.02 mV during a disorganized activation (P < 0.01). A stable relation between surface F waves and organized trabeculated right atrial activation was observed, and the mean F wave cycle length (190 +/- 27 msec) was highly comparable to the simultaneously measured endocardial cycle length (191 +/- 27 msec, correlation coefficient 0.97). F wave polarity in V1 was positive in 12 of 14 patients during craniocaudal and negative in 11 of 14 patients during caudocranial right atrial free-wall activation. CONCLUSION: An organized activation during atrial fibrillation with a predominant craniocaudal direction on the trabeculated right atrium is frequently present and influences the appearance of "coarse" or "fine" atrial fibrillation as well as F wave polarity on the surface ECG.

Adult↗

Deconvolution: a novel signal processing approach for determining activation time from fractionated electrograms and detecting infarcted tissue.

BACKGROUND: Two important signal processing applications in electrophysiology are activation mapping and characterization of the tissue substrate from which electrograms are recorded. We hypothesize that a novel signal-processing method that uses deconvolution is more accurate than amplitude, derivative, and manual activation time estimates. We further hypothesize that deconvolution quantifies changes in morphology that detect electrograms recorded from regions of myocardial infarction. METHODS AND RESULTS: To determine the accuracy of activation time estimation, 600 unipolar electrograms were calculated with a detailed computer model using various degrees of coupling heterogeneity to model infarction. Local activation time was defined as the time of peak inward sodium current in the modeled myocyte closest to the electrode. Deconvolution, minimum derivative, and maximum amplitude were calculated. Two experienced electrophysiologists blinded to the computer-determined activation times marked their estimates of activation time. F tests compared the variance of activation time estimation for each method. To evaluate the performance of deconvolution to detect infarction, 380 unipolar electrograms were recorded from 10 dogs with infarcts resulting from ligation of the left anterior descending coronary artery. The amplitude, duration, number of inflections, peak frequency, bandwidth, minimum derivative, and deconvolution were calculated. Metrics were compared by Mann-Whitney rank-sum tests, and receiver operating curves were plotted. CONCLUSIONS: Deconvolution estimated local activation time more accurately than the other metrics (P < .0001). Furthermore, the algorithm quantified changes in morphology (P < .0001) with superior performance, detecting electrograms recorded from regions of myocardial infarction. Thus, deconvolution, which incorporates a priori knowledge of electrogram morphology, shows promise to improve present clinical metrics.

Algorithms↗

Fractionated electrograms from a computer model of heterogeneously uncoupled anisotropic ventricular myocardium.

BACKGROUND: The relation between heterogeneously coupled myocardium and fractionated electrograms is incompletely understood. The purpose of this study was to use a detailed computer model of nonuniformly anisotropic myocardium to test the hypothesis that spatial variation of morphology of electrograms recorded simultaneously from multiple sites increases with increasing heterogeneity of intercellular coupling. METHODS AND RESULTS: A sheet of elements with Beeler-Reuter ionic kinetics was coupled with cytoplasmic resistivity to model cells. Gap junctional resistance values were assigned by recursive randomization to produce a fractal pattern of heterogeneous coupling, simulating damage resulting from infarction. The correlation dimension of the pattern, D, measured heterogeneity of intercellular coupling. The peak-to-peak amplitude, duration, minimum derivative (steepest downslope), number of inflections, frequency of peak power, and bandwidth of unfiltered unipolar electrograms were calculated. Linear regressions indicate (P < .001) that the coefficient of variation of five electrogram metrics increases with increasing substrate heterogeneity and that the distance over which electrogram morphology decorrelates decreases with increasing heterogeneity of intercellular coupling. CONCLUSIONS: These findings confirm our hypothesis that the spatial variation of morphology of electrograms recorded simultaneously from multiple sites increases with increasing heterogeneity of intercellular coupling.

Anisotropy↗

Effects of coupling heterogeneity on fractionated electrograms in a model of nonuniformly anisotropic ventricular myocardium.

To further understand the relation between heterogeneously infarcted myocardium and fractionated electrograms, a computer model was used to test the hypothesis that the way electrogram metrics change with electrode location relates to statistical properties of the underlying myocardium. A sheet of Beeler-Reuter elements was coupled with cytoplasmic resistance to form cells. Junctional resistance values were assigned using a recursive randomization to produce a fractal pattern, simulating damage from disrupted blood supply. The pattern's correlation dimension, D, was a statistical measure of heterogeneity. Unipolar electrogram's amplitude, duration, number of inflections, peak frequency, bandwidth, and the rate of change of metrics with height were calculated. Analysis of variance indicated (P < .0001) that peak-to-peak amplitude and bandwidth decreased at a slower rate when height was increased above heterogeneous tissue as compared with homogeneous tissue. These findings could be useful during clinical mapping procedures as statistical estimates of tissue structure.

Anisotropy↗

Using LabVIEW to facilitate calibration and verification for respiratory impedance plethysmography.

A system for calibrating the Respitrace impedance plethysmograph was developed with the capacity to quantitatively verify the accuracy of calibration. LabVIEW software was used on a Macintosh II computer to create a user-friendly environment, with the added benefit of reducing development time. The system developed enabled a research assistant to calibrate the Respitrace within 15 min while achieving an accuracy within the normally accepted 10% deviation when the Respitrace output is compared to a water spirometer standard. The system and methods described were successfully used in a study of 10 subjects smoking cigarettes containing marijuana or cocaine under four conditions, calibrating all subjects to 10% accuracy within 15 min.

Analog-Digital Conversion↗

Inbreeding as measured by isonymy, pedigrees, and population size in Törbel, Switzerland.

Törbel provides an interesting test case for the study of the relationship between inbreeding measured by pedigrees and inbreeding measured by isonymy. At the start of this investigation, we were aware that isonymy could introduce biases into the calculation of the inbreeding coefficient in either direction. However, it was expected that in Switzerland, inbreeding from isonymy would be an overestimate due to patrilocal residence and polyphyletic names. One way of dealing with this problem [13] was not to be concerned with the absolute value of inbreeding but only in the difference between estimates. Any bias introduced in the estimate itself disappears in such comparisons, so that a trend of inbreeding can be ascertained correctly. However, it was considered equally important to subject several populations to both a complete pedigree analysis and an isonymic analysis to determine the relationship between estimates of inbreeding. Despite the fact that several authors (Swedlund [18], for example) warned users of isonymy to exercise caution, the careless application of isonymy still persists. In the present study, estimates of inbreeding from isonymy were brought into line with other methods based on pedigree analysis and population size. However, it was possible to do this only in Törbel where pedigree depth was extensive and relatively complete. Similar corrections are possible only when the distribution of mono- and polyphyletic names is known and when migration data are reliable. If the trouble is taken to make these corrections, the same time and effort might as well be spent in pedigree analysis (when fairly complete ascertainment is possible) to achieve the same end result.

Consanguinity↗