PubMed Health⌕ Search

Biomedical subjects

W S L Strauss

Publications and source records attributed to W S L Strauss.

2 recordsLinked to original sources

Variable-angle total internal reflection fluorescence microscopy (VA-TIRFM): realization and application of a compact illumination device.

A novel compact illumination device in variable-angle total internal reflection fluorescence microscopy (VA-TIRFM) is described. This device replaces the standard condensor of an upright microscope. Light from different laser sources is delivered via a monomode fibre and focused onto identical parts of a sample under variable angles of total internal reflection. Thus, fluorophores in close proximity to a cell-substrate interface are excited by an evanescent wave with variable penetration depth, and localized with high (nanometre) axial resolution. In addition to quantitative measurements in solution, fluorescence markers of the cytoplasm and the plasma membrane, i.e. calcein and laurdan, were examined using cultivated endothelial cells. Distances between the glass substrate and the plasma membrane were determined using the mathematical algorithm of a four-layer model, as well as a Gaussian-shaped intensity profile of the illumination spot on the samples. Distances between 0 and 30 nm in focal contacts and between 100 and 300 nm in other parts of the cell were thus determined. In addition to measurements of cell-substrate topology, the illumination device appears appropriate for numerous applications in which high axial resolution is required, e.g. experiments on endocytosis or exocytosis, as well as measurements of ion concentrations proximal to the plasma membrane. The compact illumination device is also suitable for combining TIRFM with further innovative techniques, e.g. time-resolved fluorescence spectroscopy, fluorescence lifetime imaging (FLIM) or fluorescence resonance energy transfer (FRET).

2-Naphthylamine↗

Time-gated total internal reflection fluorescence spectroscopy (TG-TIRFS): application to the membrane marker laurdan.

A novel setup for total internal reflection fluorescence microscopy with spectral and temporal (nanosecond) resolution was used to measure the emission spectra of the membrane marker laurdan either selectively within the plasma membrane or in whole living cells, depending on the incident angle of the excitation light. With increasing temperature, the intensity of the fluorescence band around 490 nm increased in comparison with the band around 440 nm, which has previously been assigned to a phase transition of membrane lipids from gel to liquid crystalline phase. For a better separation of the overlapping spectral bands, time-gated detection with a delay of 10-15 ns with respect to the exciting laser pulse was used. As a parameter of membrane dynamics the so-called generalized polarization GP = (I440 - I490)/(I440 + I490) was evaluated at temperatures between 24 and 41 degrees C and variable angles of the incident light permitting to excite laurdan molecules either within the plasma membrane or in the whole cell. A decrease of the GP values by approximately 0.2 units between 28 and 41 degrees C indicated an increase in membrane fluidity or a decrease in membrane stiffness with increasing temperature. In addition, higher GP values were observed for the plasma membrane as compared with intracellular membranes, probably due to a higher amount of cholesterol. Because properties of the plasma membrane have a large influence on the uptake or release of certain pharmaceutical agents or metabolites, the direct assessment of the dynamics of the plasma membrane by total internal reflection fluorescence spectroscopy appears to be important for pharmacology.

2-Naphthylamine↗