Residual speech recognition and cochlear implant performance: effects of implantation criteria.
OBJECTIVE: This study aimed to determine the effects of preoperative speech reception on postoperative speech recognition with a cochlear implant and to develop a statistical index allowing prediction of postoperative speech recognition before implantation. STUDY DESIGN: The study design was a retrospective case review with statistical modeling. SETTING: The study was conducted at a tertiary referral center with an associated Veteran's Administration hospital. PATIENTS: Postlingually deafened adults with and without residual speech reception participated. INTERVENTION: Cochlear implantation with Cochlear Corporation CI-22 and CI-24 devices was performed. MAIN OUTCOME MEASURES: Monosyllabic word recognition was measured. RESULTS: Duration of deafness and preoperative sentence recognition are both significant predictors of word recognition with a cochlear implant and can account for 80% of the variance in word recognition. CONCLUSIONS: Cochlear implant outcomes are variable but predictable within specific ranges.