PubMed Health⌕ Search

Biomedical subjects

W Sauerwein

Publications and source records attributed to W Sauerwein.

At least 19 recordsLinked to original sources

[Retinoblastoma].

Retinoblastomas are the most frequent intraocular tumors in childhood. Untreated, the tumor is almost always fatal. Using a multidisciplinary approach combining the efforts of ophthalmologists, radiation oncologists, pediatric oncologists and geneticists a survival rate of more than 95% can be achieved. Molecular genetic research on the origin of retinoblastomas has substantially helped in our understanding of the origin of malignant tumors in general, as well as to the key role of the Rb-1 gene as a tumor suppressor.

Diagnosis, Differential↗

[Analysis of ocular surface alterations following proton beam radiation in eyes with conjunctival malignant melanoma].

BACKGROUND: In cases of large, diffuse or multilocular growth pattern of conjunctival melanoma, proton beam irradiation can serve as an alternative therapy to exenteration. In extended tumours, ocular surface problems can result after therapy. In this study we examined ocular surface integrity of ten patients who underwent proton beam radiation between 1996 and 2002. METHODS: The patients were examined during their follow-up. Eight of the ten cases who underwent proton radiotherapy were recurrent tumours, which were previously treated with other adjuvant therapies. We performed a standard ophthalmological examination and detailed tear film diagnostics. RESULTS: The follow-up was 17-87 months (mean: 40.9+/-20.1). In six cases more than 50% of the upper and lower eyelids were included in the radiation field. All of these cases showed moderate to severe sicca symptoms. The impression cytology revealed squamous metaplasia of conjunctival cells in nine of ten cases. CONCLUSIONS: Squamous metaplasia of conjunctival epithelia indicates a radiogenic, persisting disturbance of differentiation of the conjunctival epithelial cells. The tear film instability correlates with the loss of mucin-secreting goblet cells and meibomian gland dysfunction.

Adult↗

Ruthenium-106 plaque brachytherapy for symptomatic vasoproliferative tumours of the retina.

AIM: To investigate the safety and efficacy of beta ray brachytherapy in treatment of vasoproliferative tumours of the retina (VTR). METHODS: 35 consecutive patients with symptomatic VTR were treated with a ruthenium-106 ((106)Ru) plaque. Three tumours had been treated previously (two with cryotherapy; one with transpupillary thermotherapy). 32 VTR (91.4%) were located in the lower half of the retina and all of them were found between the mid-periphery and the ora serrata. The mean tumour thickness was 2.8 mm. An exudative retinal detachment was present in 25 eyes (71.4%) and in 15 cases (42.9%) hard exudates were found in the macula. The major symptom was loss of vision (77.1%). RESULTS: Brachytherapy was well tolerated by every patient. The mean applied dose was 416 Gy at the sclera and 108 Gy at the tumour apex. In all but four eyes (88.6%), it was possible to control the VTR activity. The median follow up time was 24 months. Three of the above mentioned four eyes with treatment failure had had secondary glaucoma before therapy. There was no case of radiation induced neuropathy or retinopathy. Cataract surgery was necessary for five patients. The development of epiretinal gliosis was the most common event during follow up (n = 10, 28.6%). The mean visual acuity decreased slightly (0.33 before and 0.29 after brachytherapy). Multivariate analysis showed that the presence of macular pathology before treatment was associated with a 6.1-fold risk of vision of 0.25 or better (p = 0.03). CONCLUSIONS: beta ray brachytherapy with (1106)Ru plaques was able to control the activity of VTR and retain vision. Cases with secondary glaucoma before treatment had a very poor prognosis.

Brachytherapy↗

Design of a rotating facility for extracorporal treatment of an explanted liver with disseminated metastases by boron neutron capture therapy with an epithermal neutron beam.

In 2001, at the TRIGA reactor of the University of Pavia (Italy), a patient suffering from diffuse liver metastases from an adenocarcinoma of the sigmoid was successfully treated by boron neutron capture therapy (BNCT). The procedure involved boron infusion prior to hepatectomy, irradiation of the explanted liver at the thermal column of the reactor, and subsequent reimplantation. A complete response was observed. This encouraging outcome stimulated the Essen/Petten BNCT group to investigate whether such an extracorporal irradiation could be performed at the BNCT irradiation facility at the HFR Petten (The Netherlands), which has very different irradiation characteristics than the Pavia facility. A computational study has been carried out. A rotating PMMA container with a liver, surrounded by PMMA and graphite, is simulated using the Monte Carlo code MCNP. Due to the rotation and neutron moderation of the PMMA container, the initial epithermal neutron beam provides a nearly homogeneous thermal neutron field in the liver. The main conditions for treatment as reported from the Pavia experiment, i.e. a thermal neutron fluence of 4 x 10(12) +/- 20% cm(-2), can be closely met at the HFR in an acceptable time, which, depending on the defined conditions, is between 140 and 180 min.

Computer Simulation↗

Analysis of 10B antitumoral compounds by means of flow-injection into ESI-MS/MS.

Boron neutron capture therapy (BNCT) is a promising binary treatment for cancer. BNCT is based on the ability of the nonradioactive isotope (10)B to capture, with a very high probability, thermal neutrons. This nuclear reaction results in two particles (an alpha and a lithium nucleus). The particles have a high biological effectiveness, which is limited in tissue to approximately the diameter of one cell. If the reaction can be limited to a tumor cell, the physical characteristic opens up the possibility to selectively destroy cancer cells, while sparing the surrounding healthy tissue. Quality control of (10)B-containing compounds and their distribution at present are very important, and different analytical methods have been developed, such as time-of-flight secondary ion mass spectrometry (TOF-SIMS), electron energy loss spectrometry (EELS), prompt gamma analysis and inductively coupled plasma-optical emission spectrometry (ICP-OES). These methods allow the analyses of (10)B, but it is not possible to characterize the specific molecular compounds containing (10)B. For this reason, we propose a fast and quantitative method that permits the determination of closo-undecahydro-1-mercaptododecaborate (BSH) and (10)boron-phenylalanine (BPA) and their eventual metabolites. In particular, (10)B-containing compounds are detected by means of flow-injection electrospray tandem mass spectrometry (FI/ESI-MS/MS). This approach allows the identification of Boron compounds, BSH and BPA, using tandem mass spectrometry, and quantitative analysis is also possible (c.v. +/-4.7%; n = 5; linear range 10-10,000 ng/ml). Furthermore, (10)B-containing compounds were detected in actual biological sample (urine and plasma, diluted 10,000- and 1,000-fold, respectively) injecting a small volume (1 microl) of diluted samples.

Adult↗

Evaluation of the standard membrane feeding assay (SMFA) for the determination of malaria transmission-reducing activity using empirical data.

Host responses to the transmittable stages of the malaria parasite may reduce transmission effectively. Transmission-reducing activity (TRA) of human serum can be determined as a percentage, using the Standard Membrane Feeding Assay (SMFA). This laboratory assay was evaluated using the results of 121 experiments with malaria-endemic sera among which many repeated measurements were obtained. The assay consists of the feeding of Anopheles stephensi mosquitoes with cultured Plasmodium falciparum gametocytes, mixed with human red blood cells, and control and experimental sera. The TRA of individual sera was determined by the comparison of oocyst densities between these sera. Bootstrap data on oocyst densities in individual mosquitoes in control feeds were used to construct confidence limits for TRA percentages of serum feeds. Low (<20%) and high TRA (>90%) values for individual sera were usually reproduced in a second experiment, whereas this was more difficult for values between 20% and 90%. The observed variability of TRA values is explained in part by the variability in oocyst density per mosquito. Oocyst densities in control feeds varied more between experiments than within experiments and showed a slight decline over the 3 years of experiments. Reproducibility of TRA of field sera was low (20%) between experiments, but much higher (61 %) within experiments. A minimum of 35 oocysts per mosquito in control feeds gave optimal reproducibility (44%) between experiments. We recommend that (1) sera are compared within an experiment, or (2) assays are only analysed where controls have at least 35 oocysts per mosquito. The SMFA is under the recommended conditions appropriate for the study of factors that may influence TRA, e.g. transmission blocking vaccines.

Animals↗

Absolute dosimetry in a d(14 MeV) + Be fast neutron beam.

Since 1978, the Universitätsklinikum in Essen operates a d(14 MeV) + Be fast neutron beam for patient treatment. Dosimetric studies were performed in a rectangular 40 x 40 mm2 neutron/photon field using a transportable water calorimeter, which had been developed at the Physikalisch-Technische Bundesanstalt. The water calorimeter allowed small dosimeters to be directly calibrated in units of absorbed dose-to-water in a cylindrical phantom of 50 mm in diameter. Also, the twin detector method was applied in order to determine the photon and the neutron dose separately. By making use of a calibrated ionization chamber, the absorbed dose-to-water calibration in the cylindrical water phantom was transferred to a water phantom, a cube 300 mm on a side. Experiments and Monte Carlo calculations covering the neutron producing target, the collimator and the influence of the water calorimeter on the spectral neutron fluence at the measurement position allow the relative uncertainty of the absorbed dose-to-water determination to be reduced to 2.6% (1 SD). This direct absorbed dose-to-water determination by calorimetry has shown that the treatment planning system underestimates the physical dose to tissue by 9%. For clinical purposes, the statement of the prescribed dose had to be increased by 9% in order that the absolute absorbed dose remains constant and that the same biological endpoints are reached.

Boron Neutron Capture Therapy↗

Advantage and limitations of weighting factors and weighted dose quantities and their units in boron neutron capture therapy.

Defining the parameters influencing the biological reaction due to absorbed dose is a continuous topic of research. The main goal of radiobiological research is to translate the measurable dose of ionizing radiation to a quantitative expression of biological effect. Mathematical models based on different biological approaches (e.g., skin reaction, cell culture) provide some estimations that are often misleading and, to some extent, dangerous. Conventional radiotherapy is the simplest case because the primary radiation and secondary radiation are both low linear energy transfer (LET) radiation and have about the same relative biological effectiveness (RBE). Nevertheless, for this one-dose-component case, the dose-effect curves are not linear. In fact, the total absorbed dose and the absorbed dose per fraction as well as the time schedule of the fractionation scheme influence the biological effects. Mathematical models such as the linear-quadratic model can only approximate biological effects. With regard to biological effects, fast neutron therapy is more complex than conventional radiotherapy. Fast neutron beams are always contaminated by gamma rays. As a consequence, biological effects are due to two components, a high-LET component (neutrons) and a low-LET component (photons). A straight transfer of knowledge from conventional radiotherapy to fast neutron therapy is, therefore, not possible: RBE depends on the delivered dose and several other parameters. For dose reporting, the European protocol for fast neutron dosimetry recommends that the total absorbed dose with gamma-ray absorbed dose in brackets is stated. However, boron neutron capture therapy (BNCT) is an even more complex case, because the total absorbed dose is due to four dose components with different LET and RBE. In addition, the terminology and units used by the different BNCT groups is confusing: absorbed dose and weighted dose are both to be stated in grays and are never "photon equivalent." The ICRU/IAEA made proposals, which should be followed by all BNCT groups, to report always the four absorbed dose components, boron dose DB, proton dose Dp, gamma-ray dose Dgamma, and neutron dose Dn, as well as the sum DT of all components, as total absorbed dose, together with the total weighted dose Dw (to be used only for internal purposes, indicating the used weighting factors) at all points of interest and the treatment conditions.

Body Burden↗

Reno, a European postmarket surveillance registry, confirms effectiveness of coronary brachytherapy in routine clinical practice.

PURPOSE: To assess, by a European registry trial, the clinical event rate in patients with discrete stenotic lesions of coronary arteries (de novo or restenotic) in single or multiple vessels (native or bypass grafts) treated with beta-radiation. MATERIALS AND METHODS: Between April 1999 and September 2000, 1098 consecutive patients treated in 46 centers in Europe and the Middle East with the Novoste Beta-Cath System were included in Registry Novoste (RENO). RESULTS: Six-month follow-up data were obtained for 1085 patients. Of 1174 target lesions, 94.1% were located in native vessels and 5.9% in a bypass graft; 17.7% were de novo lesions, 4.1% were restenotic, and 77.7% were in-stent restenotic lesions. Intravascular brachytherapy was technically successful in 95.9% of lesions. Multisegmental irradiation, using a manual pullback stepping maneuver to treat longer lesions, was used in 16.3% of the procedures. The in-hospital rate of major adverse cardiac events was 1.8%. At 6 months, the rate was 18.7%. Angiographic follow-up was available for 70.4% of the patients. Nonocclusive restenosis was seen in 18.8% and total occlusion in 5.7% of patients. A combined end point for late (30-180 days) definitive or suspected target vessel closure was reached in 5.4%, but with only 2% of clinical events. Multivariate analysis was performed for major adverse cardiac events and late thrombosis. CONCLUSIONS: Data obtained from the multicenter RENO registry study, derived from a large cohort of unselected consecutive patients, suggest that the good results of recent randomized controlled clinical trials can be replicated in routine clinical practice.

Aged↗

[Brachytherapy after coronary interventions: current state and future perspectives].

Intracoronary brachytherapy is a novel, meanwhile established therapy. It is currently the only interventional procedure which has proven to effectively reduce the restenosis rates after intervention of long and diffuse in-stent restenosis. For this indication, brachytherapy can be regarded as the current treatment of choice. Randomized studies yield promising results for bypass interventions or interventions in small vessels or diabetic patients. These findings may encourage the decision to perform a percutaneous, transluminal intervention in such high-risk patients. In clinical practice, implantation of new stents in combination with brachytherapy procedures should be avoided as far as possible. In any case, the combined antiaggregatory therapy should be conducted sufficiently long to minimize the danger of late stent thrombosis. Under this treatment, the expected thrombosis rates ar within the range of placebo-treated patients. The length of the radiation source should be sufficient to cover the entire interventional injury length to avoid recurrent edge stenosis. De novo lesions are currently not a routine indication for intracoronary brachytherapy. Although intracoronary brachytherapy may effectively reduce restenosis rates in sufficiently irradiated de novo lesion segments, de novo lesions should be treated only within the set-up of controlled studies. The current available data with a follow-up period of up to 5 years show that intracoronary brachytherapy is also in the mid-term a safe and effective therapy for the reduction of restenosis after coronary interventions.

Angioplasty, Balloon, Coronary↗

Subcellular localization of boron in cultured melanoma cells by electron energy-loss spectroscopy of freeze-dried cryosections.

Boron neutron capture therapy (BNCT) is based on the ability of the non-radioactive isotope 10B to capture thermal neutrons and to disintegrate instantaneously. This reaction opens a way to selectively destroy tumour cells after specific uptake of 10B. In this paper, a method based on electron energy-loss spectroscopy is presented for detecting and quantifying boron in freeze-dried cryosections of human melanoma cells. A practical detection limit of around 6 mmol kg-1 in 0.1- micro m2 areas is estimated using specimens prepared from standard boron solutions. Preliminary results of boron mapping in the spectrum-imaging acquisition mode reveal boron penetration and probably spot-like accumulation within melanoma cells when exposed to culture medium containing sodium borocaptate.

Boron↗

[Intraoperative radiotherapy in Germany].

BACKGROUND: Intraoperative radiotherapy (IORT) represents an attractive method for local tumour control after surgical resection. IORT was introduced into multimodal treatment protocols in the 1980s. Aim of this study was to analyse the actual clinical and scientific activity of IORT in Germany. METHODS: Questionnaires were sent to 102 centres in Germany. The analysis was focussed on indications in general surgery including bone tumours to evaluate the activity of IORT. The literature was analysed by a medline search for the years 1975 to 2001. RESULTS: Questionnaires were answered by 92% of the centres. 24 departments are working with IORT in Germany (16 of them are university hospitals). Main Indications for IORT treatment are rectum carcinoma and soft tissue sarcoma. Furthermore, IORT is used in patients suffering from gastric, pancreatic and bile duct malignancies. Some IORT programs are also targeting on patients with head and neck malignancies and brain tumours. German institutions published within the last 5 years about 14% of all " Medline"-listed publications concerning IORT. CONCLUSION: There is an profound activity of IORT in Germany, which is concentrated on a few centres. A need for better national and international cooperation of centres performing IORT for clinical trials and to collect significant numbers of patients seems to be evident.

Bile Duct Neoplasms↗

Validation of a pencil beam model-based treatment planning system for fast neutron therapy.

Treatment planning systems (TPSs) are used to compute dose delivered to the patient. In the case of fast neutron therapy, TPSs are mostly not of general purpose but are dedicated to one facility. This is due to the few fast neutron facilities worldwide and due to the high variation in the neutron energy distributions. Efforts have been undertaken to develop a new TPS that could be applied to all the existing fast neutron facilities. The University Hospital of Essen operates a d (14 MeV) + Be fast neutron beam and the TPS used is based on an empirical model. In a previous study, the empirical model has been evolved to a pencil beam model of 35 monoenergetic neutron beams. Monte Carlo techniques have been utilized to compute distributions of the energy deposition due to primary and scattered neutrons in a simple geometry water phantom. The experimental validation of the method is now presented. Depth dose curves in water of monoenergetic neutrons have been derived from the distributions of energy deposition. The resultant depth dose curves have been utilized in order to determine the depth dose curves of the fast neutron beam of the Essen facility for the 14 radiation field sizes available in this facility. This determination requires the initial neutron spectrum. As this spectrum could not be measured at the Essen facility, the initial neutron spectrum of the Physikalisch Technische Bundesanstalt, Braunschweig, Germany, which operates the same cyclotron, was used. The calculated depth dose curves were compared to experimental depth dose curves that have been obtained in water at the University Hospital of Essen. The comparison between calculated and experimental depth dose curves showed significant deviations in the case of large radiation fields and of depth less than 5 cm. In the case of radiation field areas less than 150 cm2 and depth more than 5 cm (usual clinical situation), the measured and calculated values are in a good agreement. In the case of clinical situation, the dependence on the radiation field size is relatively well taken into account by the model presented here.

Computer Simulation↗

Towards in vivo monitoring of neutron distributions for quality control of BNCT.

Dose delivery in boron neutron capture therapy (BNCT) is complex because several components contribute to the dose absorbed in tissue. This dose is largely determined by local boron concentration, thermal neutron distribution and patient positioning. In vivo measurements of these factors would considerably improve quality control and safety. During therapy, a y-ray telescope measures the y-rays emitted following neutron capture by hydrogen and boron in a small volume of the head of a patient. Scans of hydrogen y-ray emissions could be used to verify the actual distribution of thermal neutrons during neutron irradiation. The method was first tested on different phantoms. These measurements showed good agreement with calculations based on thermal neutron distributions derived from a treatment planning program and from Monte Carlo N-particle (MCNP) simulations. Next, the feasibility of telescope scans during patient irradiation therapy was demonstrated. Measurements were reproducible between irradiation fractions. In theory, this method can be used to verify the positioning of the patient in vivo and the delivery of thermal neutrons in tissue. However, differences between measurements and calculations based on a routine treatment planning program were observed. These differences could be used to refine the treatment planning. Further developments will be necessary for this method to become a standard quality control system.

Algorithms↗

The EORTC Boron Neutron Capture Therapy (BNCT) Group: achievements and future projects.

Boron Neutron Capture Therapy (BNCT) is an experimental treatment modality that takes place in a nuclear research reactor. To progress from preclinical studies to patient treatment is a challenge requiring strict quality management and special solutions to licensing, liability, insurance, responsibility and logistics. The European Organisation for the Research and Treatment of Cancer (EORTC) BNCT group has started the first European clinical trial of BNCT for glioblastoma patients at the European High Flux Reactor (HFR) in Petten, The Netherlands, conducted by the Department of Radiotherapy of the University of Essen, Germany. A very strict quality management had to be installed following the European rules on safety and quality assurance for nuclear research reactors, for radioprotection, for radiotherapy and for clinical trials. The EORTC BNCT Group has created a virtual European-wide hospital to handle the complex management of patients treated with BNCT. New clinical trials are currently under development.

Boron Neutron Capture Therapy↗

Empirical description and Monte Carlo simulation of fast neutron pencil beams as basis of a treatment planning system.

The fast neutron beam, used for fast neutron therapy in Essen, is produced by the nuclear reaction of a 14 MeV cyclotron-based deuteron beam on a thick beryllium target. The resulting neutron beam has a continuous energy spectrum with a mean and a maximum energy equal to 5.5 and 18 MeV, respectively. The dose delivered to the patient is computed by a treatment planning system (TPS) based on an empirical model, in which the dose components (neutron and photon) are described by analytical functions. In order to improve the dose calculation, and thus to use the fast neutron beam for other applications (e.g., Boron Neutron Capture Enhancement of Fast Neutron Therapy), in this work we aim to develop a new TPS. For this purpose, a model based on pencil beams of mono-energetic neutrons has been created. The neutron energy ranged from 0.25 MeV up to 17.25 MeV by steps of 0.5 MeV in order to cover the energy range of the Essen facility. The Monte Carlo method was then used to simulate the transport of neutrons within such pencil beams in a homogeneous water phantom. By using Monte Carlo techniques, it is possible to distinguish the energy deposition due to a primary collision in water to that due to scattered neutrons. The energy deposition due to pencil beams of 2.224 MeV photons, coming from hydrogen neutron capture reaction in the phantom or in the collimator, was also determined. In order to complete this work, air filled cylinders have been introduced in the water phantom. It is shown that the resulting depth dose curves for primary neutrons can be easily derived using the homogeneous phantom, and that the description of the effect on scattered neutron dose distribution is more complex. In this work we demonstrate the relevance of Monte Carlo simulations of mono-energetic neutron pencil beams for purposes of neutron treatment planning. Some additional work is still required to describe a clinical situation (continuous energy neutron spectrum) as well as to experimentally validate the method described here.

Adipose Tissue↗

A scheme for a dose-escalation study when the event is lagged.

Classical designs for clinical phase I trials assume that information about a dose-limiting event (DLE) is available for all the included patients, or advise not to treat new patients until the information is present. If a DLE occurs after a lag, however, information at the current time might not be sufficient to make clear-cut decisions according to these designs. In particular, if new patients are available, it is not clear whether to include them in the trial. We suggest a rule that decides on the accrual of each individual eligible patient. Simulation studies are presented that indicate an advantage over the standard 'three-at-once' design in the length of the study.

Boron Neutron Capture Therapy↗