PubMed Health⌕ Search

Biomedical subjects

W Serlo

Publications and source records attributed to W Serlo.

At least 19 recordsLinked to original sources

Treatment of pectus excavatum with bioabsorbable polylactide plates: Preliminary results.

BACKGROUND/PURPOSE: Pectus excavatum usually is corrected by thoracoplasty using metal plates. Recently bioabsorbabe polylactide plates have been developed. The aim of this study was to compare outcome after use of metal and bioasorbable plates in thoracoplasty performed for correction of pectus excavatum. METHODS: Eighty-three children (<16 years old) underwent thoracoplasty (Sulamaa's technique). In 75 patients, metallic plates, and in 8 patients, self-reinforced poly-L-lactide (SR-PLLA) plates, were used. Seven patients in the SR-PLLA group and 13 patients in the metal plate group were assessed 0.5 to 13 years postoperatively. RESULTS: The mean operating time was 121 minutes in the metal plate group, and 87 minutes in the SR-PLLA plate group. In the metal plate group, complications were pain caused by instability of the metal plates (n = 17), wound infection (n = 3), recurrence of deformity (n = 3), postoperative pain (n = 3), pneumothorax (n = 1), and nonspecific postoperative fever (n = 1). Thirteen patients underwent reoperation to refix the position of the metallic plates. In the SR-PLLA group, one case of pneumothorax occurred, and plate fragment palpability caused local pain in one patient. Cosmetic results and lung function values were similar. CONCLUSION: Our preliminary results show that bioabsorbable plates are a useful option in the treatment of pectus excavatum in children.

Absorbable Implants↗

Use of self-reinforced polylactide osteosynthesis devices in craniofacial surgery: a long-term follow-up study.

Self-reinforced polylactic acid or polylactide (SR-PLA) is a biodegradable polymer, which is strong enough to fix weight-bearing cortical bone fractures and osteotomies. We report our experience and follow-up of the use of SR-PLA plates in 15 clinical cranioplasties. Two of the cases are described in greater detail. In one of them SR-PLA plates were used in addition to titanium plates, and in the other an SR-PLA plate fixed with mini-titanium screws was used as the only fixation material. In the other patients SR-PLA plates or wire were used in addition to titanium. So far no complications have been observed in these 15 patients. The only small superficial fistula was associated with a titanium plate and titanium screws. The longest follow-up has been over eight years. Recent results show metal-like deformation properties in addition to complete late resorption, making SR-PLA osteosynthesis devices promising for use in craniofacial surgery.

Absorbable Implants↗

Developments in craniomaxillofacial surgery: use of self-reinforced bioabsorbable osteofixation devices.

Because of the problems associated with the conventional osteofixation devices used in craniomaxillofacial surgery, absorbable devices present an appealing alternative. Devices made of the polymers polylactide, polyglycolide, and their copolymers (PLGA and P[L/DL]LA) are currently the most commonly used. Ultrahigh-strength implants can be manufactured from these polymers with the self-reinforcing technique. Over the authors' almost two decades of study, both in experimental and clinical settings, self-reinforced devices have proved to be biocompatible, easy to handle, and mechanically strong, even for the fixation of femoral neck fractures. In craniomaxillofacial surgery, the authors have used self-reinforced devices for over 8 years without complications. Because of the more favored degradation characteristics, currently the copolymeric self-reinforced devices (P[L/DL]LA, Biosorb FX and PLGA, Biosorb PDX; Elite Performance Technologies, Solana Beach, Calif.) represent the advancing front in the application of absorbable devices in craniomaxillofacial surgery. The authors' share their experience and their studies of self-reinforced devices, which possess the highest strength and ductility of all bioabsorbable products.

Absorbable Implants↗

Frontal head posture in shunt-treated hydrocephalic patients.

OBJECTS: The aim of this study was to evaluate frontal head posture in shunt-treated hydrocephalic patients and its relation to the sidedness of the shunt device. METHODS: Natural head position and frontal cephalograms of 55 shunt-treated Finnish hydrocephalic patients and 33 healthy Finnish subjects were analysed using a computerised digitising program (X-METRIX). The following reference angles were used: ORB/HOR, indicating the head position related to the true horizontal; CER/VER, indicating the cervical position related to the true vertical; and CER/CR, indicating the craniocervical position. CONCLUSIONS: The results showed an increased skewness of the head in the shunt-treated subjects, which was not related to the shunt side.

Adolescent↗

A new technique for correction of trigonocephaly in an infant: application of an absorbable endocranial plate.

We report on a new method of cranial bone osteofixation using absorbable material, which is applied endocranially to avoid the application of a thick, cosmetically inferior system epicranially in the frontal area. This is especially important in the correction of deformity in trigonocephaly cases. A 9-month-old boy presented with a prominent trigonocephalic deformity. Cranioplasty was performed, in which a supraorbital bar (bandeau) was removed, reinforced with a self-reinforced polylactide (SR-PLA) plate and reshaped to correct the deformity. The plate was applied on the inner side of the bony bar, with its ends fixed epicranially to the temporal bones by means of SR-PLA miniscrews. 3-D CT scans and rapid prototypes were used to evaluate the results. Stable and secure fixation was obtained, and the cosmetic result appeared excellent. No complications occurred during the postoperative period of 1 year. Hence, stabilisation of cranial bone can be achieved endocranially using an absorbable plate and screws, with an encouraging cosmetic result. The method is thought to be reliable.

Biocompatible Materials↗

Bone healing and mineralization, implant corrosion, and trace metals after nickel-titanium shape memory metal intramedullary fixation.

Its shape memory effect, superelasticity, and good wear and damping properties make the NiTi shape memory alloy a material with fascinating potential for orthopedic surgery. It provides a possibility for making self-locking, self-expanding, and self-compressing implants. Problems, however, may arise because of its high nickel content. The purpose of this work was to determine the corrosion of NiTi in vivo and to evaluate the possible deleterious effects of NiTi on osteotomy healing, bone mineralization, and the remodeling response. Femoral osteotomies of 40 rats were fixed with either NiTi or stainless steel (StSt) intramedullary nails. The rats were killed at 2, 4, 8, 12, 26, and 60 weeks. Bone healing was examined with radiographs, peripheral quantitative computed tomography, (pQCT) and histologically. The corrosion of the retrieved implants was analyzed by electron microscopy (FESEM). Trace metals from several organs were determined by graphite furnace atomic absorption spectrometry (GF-AAS) or by inductively coupled plasma-atomic emission spectrometry (ICP-AES). There were more healed bone unions in the NiTi than in the StSt group at early (4 and 8 weeks) time points. Callus size was equal between the groups. The total and cortical bone mineral densities did not differ between the NiTi and StSt groups. Mineral density in both groups was lower in the osteotomy area than in the other areas along the nail. Density in the nail area was lower than in the proximal part of the operated femur or the contralateral femur. Bone contact to NiTi was close. A peri-implant lamellar bone sheet formed in the metaphyseal area after 8 weeks, indicating good tissue tolerance. The FESEM assessment showed surface corrosion changes to be more evident in the StSt implants. There were no statistically significant differences in nickel concentration between the NiTi and StSt groups in any of the organs. NiTi appears to be an appropriate material for further intramedullary use because it has good biocompatibility in bone tissue.

Animals↗

Bone modeling and cell-material interface responses induced by nickel-titanium shape memory alloy after periosteal implantation.

The purpose of this study was to evaluate the new bone formation, modeling and cell-material interface responses induced by nickel-titanium shape memory alloy after periosteal implantation. We used a regional acceleratory phenomenon (RAP) model, in which a periosteal contact stimulus provokes an adaptive modelling response. NiTi has thermal shape memory and superelasticity properties uncommon in other implant alloys. So far, there are insufficient data concerning the biocompatibility of NiTi as a bone implant. NiTi was compared to stainless steel (stst) and Ti-6Al-4V. The test implant was placed in contact with the intact femur periosteum, but it was not fixed inside the bone. Histomorphometry with digital image analysis was used to determine the bone formation and resorption parameters. The ultrastructural features of cell-material adhesion were analysed with scanning electron microscopy (FESEM). A typical peri-implant bone wall modelation was seen due to the normal RAP. The maximum new woven bone formation started earlier (2 weeks) in the Ti-6Al-4V group than in the NiTi (P < 0.01) group, but also decreased earlier, and at 8 weeks the NiTi (P < 0.05) and stst (P < 0.005) groups had greater cortical bone width. At 12 and 26 weeks no statistical differences were seen in the histomorphometric values. The histological response of the soft tissues around the NiTi implant was also clearly non-toxic and non-irritating. Cell adhesion and focal contacts were similar between the materials studied by FESEM. We conclude that NiTi had no negative effect on total new bone formation or normal RAP after periosteal implantation during a 26-week follow-up.

Alloys↗

Comparison of self-reinforced poly-L-lactide and steel wire in fixation of sternotomy in rabbits.

BACKGROUND AND AIMS: To investigate the healing of sternotomies fixed with biodegradable self-reinforced poly-L-lactide (SR-PLLA) wire and comparing it with steel wire fixation. MATERIAL AND METHODS: Sixteen rabbits (15 Chinchilla and one New Zealand White rabbit) were operated on. Two parallel holes of 1.5 mm in diameter were drilled in the sternum at the level of the second and third rib and similar holes of 0.8 mm were drilled at the level of the third and fourth rib. A transverse sternotomy was created between both drill hole pairs. The sternotomy with larger drill holes was fixed with 1.1-mm thick SR-PLLA wire. The sternotomy between the smaller drill holes was fixed using 2.0 steel wire. The animals were sacrificed at 2, 7, 26 and 52 weeks postoperatively and specimens were taken, radiographed and studied by both light and scanning electron microscopy. RESULTS: One rabbit died at four months postoperatively as a result of gastrointestinal problems. No other complications were seen. The SR-PLLA wire was slowly degraded. There was no disturbance of bone healing. The implants were surrounded by a fibrous tissue capsule, which also contained chronic inflammatory cells. Both SR-PLLA and steel wires provided sufficient fixation security. No differences in the healing of the sternotomies were observed between SR-PLLA and steel wire fixation. CONCLUSIONS: SR-PLLA wires are biocompatible and useful for sternotomy fixation. They may be suitable for use in clinical applications.

Absorbable Implants↗

In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: muscle and perineural tissue responses and encapsule membrane thickness.

Nickel-titanium shape memory alloy (Nitinol) has properties that could be very useful in surgical applications. Thermal shape memory, superelasticity, and high damping properties make such alloys behave differently compared to other implant metals. There has previously been a lack of sufficient evidence on the biocompatibility of Nitinol. The purpose of this study was to evaluate general soft tissue response and biocompatibility to Nitinol in vivo, and to clarify neural and perineural responses, previously unreported. Seventy-five rats were randomized into three groups. Test specimens were implanted into paravertebral muscle and near the sciatic nerve. A comparison was made between Nitinol, stainless steel, and Ti-6Al-4V. The animals were euthanized at 2, 4, 8, 12, and 26 weeks after implantation. General morphologic and histologic observations were made under light microscopy. Semiautomatic computerized image analysis was used to measure the encapsule membrane thickness around the implants. The muscular tissue response to Nitinol was clearly nontoxic, regardless of the time period. The overall inflammatory response to Nitinol was very similar to that of stainless steel and Ti-6Al-4V alloy. There were no necroses, granulomas, or signs of dystrophic soft tissue clacification. The immune cell response to Nitinol remained low. Only a few foreign-body giant cells were present. The detected neural and perineural responses were also clearly nontoxic and nonirritating with Nitinol. No qualitative differences in histology between the different test materials could be seen. At 8 weeks, the encapsule membrane of Nitinol was thicker than that of stainless steel (mean 62 +/- 25 microns vs. 41 +/- 8 microns). At the end of the study, the encapsule thickness was equal to all the materials tested. We concluded that Nitinol had good in vivo biocompatibility after intramuscular and perineural implantation in rats in the 26-week follow-up. Based on the results of the present study, Nitinol appears to have good potential for clinical use.

Animals↗

Pituitary function in children with hydrocephalus before and after the first shunting operation.

OBJECTIVE: Children with shunted hydrocephalus experience slow linear growth in prepuberty, accelerated pubertal maturation and a reduced final height. A substantial proportion of these patients have a poor growth hormone (GH) response to stimulation and reduced pituitary volume. The basic mechanisms behind these phenomena are still unknown, but one can hypothesize that an unphysiological intracranial pressure (ICP) may be involved. This study was undertaken to investigate the effect of increased ICP on pituitary function. DESIGN: Twenty-one children (nine males) aged 4 months to 15 years were evaluated for pituitary function before and after their first shunting operation. METHODS: A clinical examination was performed, bone age was determined and a combined pituitary stimulation test was performed to evaluate GH, luteinizing hormone, follicle-stimulating hormone, cortisol, thyrotropin and prolactin secretion. RESULTS: GH concentrations were significantly higher 10 and 15 min before the operation (P=0.04 and P=0.03 respectively) than after it. The basal levels of insulin-like growth factor-I (IGF-I) tended to be higher before the operation than afterwards and those of its binding protein-3 (IGFBP-3) were significantly so (P<0.01). CONCLUSIONS: The higher GH response to GH releasing hormone and circulating IGFBP-3 levels in children with hydrocephalus before compared with after their first shunting operation raise the possibility that the reduced GH secretion and retarded linear growth observed in children with shunted hydrocephalus may be a consequence of decreased ICP and/or the lack of physiological pressure variations.

Adolescent↗

Lateral release and proximal realignment for patellofemoral malalignment. A prospective study of 40 knees in 36 adolescents followed for 1-8 years.

We performed lateral release and proximal realignment for painful patellofemoral malalignment in 36 adolescents (40 knees), with a mean age of 14 (9-16) years. The mean follow-up was 4 (1-8) years. The subjective outcome was excellent in 20 knees, good in 13, fair in 5, and poor in 2. The mean radiographic correction of the lateral patellar shift was 75%, and of the tilting angle of the patellar 27%. There was a positive association between the realignment effect and the subjective outcome.

Adolescent↗

Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures.

Nickel-titanium alloy (Nitinol) is a metallic biomaterial that has a unique thermal shape memory, superelasticity, and high damping properties. Nitinol is potentially very useful in orthopedic surgery, for example. At present, there are not enough confirmative biocompatibility data available on Nitinol. The aim of our study was to clarify the primary cytotoxicity and corrosion rate of Nitinol in human cell cultures. Comparisons were made with stainless steel (Stst), titanium (Ti), composite material (C), and control cultures with no test discs. Human osteoblasts (OB) and fibroblasts (FB) were incubated for 10 days with test discs of equal size, 6 x 7 mm. The cultures were photographed and the cells counted. Samples from culture media were collected on days 2, 4, 6, and 8, and the analysis of metals in the media was done using flameless atomic absorption spectrophotometry. The proliferation of FB was 108% (Nitinol), 134% (Ti) (p < 0.02), 107% (Stst), and 48% (C)(p < 0.0001) compared to the control cultures. The proliferation of OB was 101% (Nitinol), 100% (Ti), 105% (Stst), and 54% (C) (p < 0.025) compared to the controls. Initially, Nitinol released more nickel (129-87 micrograms/L) into the cell culture media than Stst (7 micrograms/L), but after 2 days the concentrations were about equal (23-5 micrograms/L versus 11-1 micrograms/L). The titanium concentrations from both Nitinol and Ti samples were all < 20 micrograms/L. We conclude that Nitinol has good in vitro biocompatibility with human osteoblasts and fibroblasts. Despite the higher initial nickel dissolution, Nitinol induced no toxic effects, decrease in cell proliferation, or inhibition on the growth of cells in contact with the metal surface.

Biocompatible Materials↗

Pituitary size and function in children and adolescents with shunted hydrocephalus.

OBJECTIVE: Most previous reports of endocrine disorders in children with shunted hydrocephalus have been case reports and there is a lack of systematic information on pituitary anatomy and function among these children. We have obtained these data in a large group of individuals with shunted hydrocephalus. DESIGN: A controlled cross-sectional study. PATIENTS: Fifty-four children and adolescents with shunted hydrocephalus were studied for pituitary anatomy and function. They had 54 age- and sex-matched controls (group I). The mean age of the patients and controls was 12.6 years and the mean shunting period 10.6 years. There was a second control group (II) for the magnetic resonance imaging (MRI) and a third control group (III) for the radiography of the sella turcica. MEASUREMENTS: The anatomy was visualized by MRI of the pituitary gland and by radiography of the sella turcica. The functional evaluation included an arginine-insulin test and a combined stimulation test with corticotrophin releasing factor (CRF), GnRH and TRH. RESULTS: The patients were shorter (height 148.4 cm vs 153.7 cm, P < 0.05 and relative height -0.5 SDS vs 0.4 SDS, P < 0.05) and had a higher BMI than the control group I (20.6 kg/m2 vs 18.0 kg/m2, P < 0.001). They had also a greater pituitary height than the control group II (5.8 mm vs 5.1 mm, P < 0.01). The patients had significantly lower basal GH levels (P < 0.001) than controls I. Sixteen patients (30%) had a poor GH response (< 20 mU/l) in the arginine-insulin test. Pituitary height was significantly lower among these patients than in those with a normal response (4.7 mm vs 6.3 mm, P < 0.01), who had an increased pituitary height compared to controls II (5.1 mm, P < 0.01). The area under the curve (AUC) for GH correlated with the pituitary volume (r = 0.50, P < 0.001). The patients had higher basal FSH and LH concentrations than controls I (P < 0.001). The peak to basal ratios of FSH and LH were increased in the prepubertal patients and that of LH at Tanner pubertal stage II in the females. The basal FSH and LH levels correlated with the pituitary volume (r = 0.50 and r = 0.54, P < 0.001 for), as did FSH AUC and LH AUC (r = 0.48 and r = 0.75, P < 0.001 for both). CONCLUSIONS: These observations indicate that children with shunted hydrocephalus have an increased pituitary size on average. About one-third of these patients had signs of reduced GH secretion and significantly lower pituitary height, which probably contributes to their poor linear growth. Increased pituitary size was associated with enhanced gonadotrophin secretion, which may result in early puberty in children with shunted hydrocephalus.

Adolescent↗

Reduced levels of growth hormone, insulin-like growth factor-I and binding protein-3 in patients with shunted hydrocephalus.

OBJECTIVE: Children with hydrocephalus are characterised by slow linear growth in prepuberty, accelerated physical maturation during puberty, and reduced final height. We aimed to study the possible roles of growth hormone, insulin-like growth factor-I (IGF-I), and IGF binding protein-3 (IGFBP-3) in this growth pattern. STUDY DESIGN: One hundred and fourteen patients with shunted hydrocephalus (62 males) aged 5 to 20 years, of whom 17 had spina bifida (six males), and 73 healthy controls (38 males) were studied. Anthropometric measures, body mass index, and body fat mass were assessed and the stage of puberty was determined. Serum growth hormone and plasma IGF-I and IGFBP-3 concentrations were measured. RESULTS: The patients comprised 44 (26 males) who were prepubertal and 70 (36 males) pubertal or postpubertal, while 32 of the controls (19 males) were prepubertal and 41 (19 males) pubertal or postpubertal. The prepubertal children with hydrocephalus had lower IGF-I (p = 0.002) and IGFBP-3 concentrations (p < 0.001) than the controls, and the pubertal children had four times lower basal growth hormone concentrations (p < 0.001). There was a correlation between height SD score and IGF-I levels in the total patient population (r = 0.23; p = 0.01). Peripheral IGF-I concentrations peaked at pubertal stages 2-3 in the female patients and at stage 4 in the controls. The prepubertal patients on antiepileptic treatment, carbamazepine in most cases (73%), had higher IGF-I (p = 0.01) and IGFBP-3 concentrations (p = 0.03) than those who had never been treated with antiepileptic drugs, but still lower IGFBP-3 levels than the controls (p = 0.01). CONCLUSION: Based on these findings, it can be concluded that reduced growth hormone secretion may contribute to the pattern of slow linear growth and reduced final height observed in these patients.

Adolescent↗

Intraventricular rhabdomyosarcoma after resection of hyperplastic choroid plexus.

Primary intracranial rhabdomyosarcoma is extremely rare. Here, a case that is most consistent with a botryoid rhabdomyosarcoma is described in a 4.5-year-old boy. The case is unique because it was preceded by a congenital Dandy-Walker malformation, choroid plexus hyperplasia and an enormous oversecretion of cerebrospinal fluid during infancy.

Brain Diseases↗

Axial radiography or CT in the measurement of patellofemoral malalignment indices in children and adolescents?

The present study compares the repeatability of patellofemoral malalignment (PFM) indices obtained by 20 degree flexion axial radiography (AR) and computerized tomography (CT) with 0 degree and 20 degree flexion of the knees in children and adolescents. Thirty-one patients with a mean age of 14.2 years (range 8 to 19.2 years) suffering from PFM were examined using these two radiographic techniques. The lateral patellofemoral angle (LPA), the lateral patellar tilt (LPT), and the lateral patellar displacement (LPD) were measured by by two different investigators on different occasions, and the agreement of these indices between CT and AR was evaluated according to Bland and Altman's statistical method. LPT and LPD obtained by AR were more reliable and repeatable than those obtained by CT. The quadriceps muscle contraction exacerbates PFM indices significantly with the knees in full extension (P = 0.0001). LPT and LPD measured at 20 degrees AR show reliably the two pathological components (the patellar tilt and the lateral patellar displacement) of PFM which are necessary for diagnosis and treatment planning. CT with quadriceps contractions is better in qualitative screening of more subtle cases of PFM.

Adolescent↗

Arthroscopy in the diagnostics and treatment of non-acute knee disorders in children.

199 arthroscopies were performed on children with non-acute knee problems during 1985-1992 at the University Hospital of Oulu (76 boys and 123 girls). The mean age was 13 (2-15) years. The ratio between boys and girls was 1:1.6 showing the incidence among girls to be greater. The mean duration of symptoms was 16 (0.3-96) months before the arthroscopy. Major diagnostic groups were plica syndrome (43 cases), malalignment of the patella (29 cases), osteochondritis dissecans (28 cases) and arthritis of the knee (28 cases). The accuracy of clinical diagnosis was 47% in preadolescents and 51% in adolescents. Operations were performed arthroscopically in 71 cases, by open arthrotomy in 15 and by other extra-articular operations in 39. These children were followed until no further treatment was needed. The mean follow-up time was 4 years and 6 months (20-97 months). A total of 172 (87%) patients needed no further treatment, while 27 (13%) children were rearthroscopied and a reoperation was performed on 15 of these.

Adolescent↗