Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high-molecular-weight polyethylene.

Surface damage of the tibial plateau components of knee prostheses made from medical grade ultra-high-molecular-weight polyethylene (UHMW-PE) has been attributed to delamination wear caused by a fatigue fracture mechanism. It has been proposed that factors such as component design and method of sterilization contribute to such failure mechanisms. Understanding the fracture behaviour of UHMW-PE is therefore critical in optimizing the in vivo life-span of total joint components. The elastic-plastic fracture toughness parameter J was consequently determined for a commercial UHMW-PE at ambient and body temperatures, before and after gamma-irradiation sterilization in air at a minimum dose of 29 kGy. Both ductile stability theory and experimental data suggest that cracks propagate in a stable manner, although stability is affected by the sterilization process. Sterilization with gamma-irradiation results in a loss in fracture toughness JIc of 50% and a decrease in tearing modulus (Tm) of 30%. This dramatic reduction could result in a 50% decrease in the residual strength of the components, maximum permissible crack size under service loading and service life (assuming flaws such as fusion defects exist). The time required for a crack to grow from its original size to the maximum permissible size could be decreased by 30%, resulting in earlier failure. In terms of the design of joint replacement components the critical factor to envisage is the design stress level, which should be halved to account for the irradiation process. A scanning electron microscope study reveals that the material fails in layers parallel to the fracture surface.

Biocompatible Materials↗

Effects of batch to batch variations and test methodology on degree of crystallinity and melting temperature of UHMW-PE as measured by differential scanning calorimetry.

The thermal and structural analysis of a total 22 batches from three medical grade ultrahigh molecular weight polyethylene (UHMW-PE) resins was determined using the DSC method. Batch to batch variations of approximately 5% were obtained for the melting temperature and the degree of crystallinity. The variations correlated both to the changes caused by gamma-irradiation sterilization and subsequent aging, and to the differences in DSC results obtained from various laboratories on materials believed to exhibit essentially similar clinical performances. Varying the sample weight from 4.4 to 27.1 mg resulted in a significant relative increase of 5% in the degree of crystallinity. The study shows that the standard double melting/recrystallisation procedure for DSC evaluation produces variations in the melting behaviors of approximately the same magnitude as those indicated by batch lot or sterilization/aging.

Calorimetry, Differential Scanning↗