Overcoming early cyclosporine nephrotoxicity after liver transplantation.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to W T Merritt.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The validity of the Dinamap automated oscillometric blood pressure monitor, an instrument frequently used for continuous monitoring in intensive care settings, was evaluated in comparison to two standard methods of blood pressure measurement. Oscillometric monitoring was compared to random-zero sphygmomanometry in 28 ambulatory subjects, using the instruments in a random order. The oscillometric monitor overestimated random-zero systolic pressure (mean difference = 5.7 mm Hg; P less than 0.001), but did not differ in diastolic pressure (difference = 1.3 mm Hg, P greater than 0.3). Correlation (r) between methods was 0.94 for systolic pressure and 0.83 for diastolic pressure. Repeatability of sequential measures did not differ between methods. To evaluate the oscillometric monitor in the intraoperative setting, it was used simultaneously with a radial artery catheter to measure blood pressure in 14 patients undergoing peripheral vascular or other major surgery. The oscillometric monitor underestimated intra-arterial systolic pressure (mean difference = -9.4 mm Hg; P less than 0.002), but overestimated intraarterial diastolic pressure (difference = 5.7 mm Hg; P less than 0.005). There was no difference in mean arterial pressure (P greater than 0.1). Correlation between methods was 0.88 for systolic, 0.71 for diastolic, and 0.79 for mean arterial pressure. The oscillometric instrument had a sensitivity of 63% and specificity of 97% in detecting intraarterial systolic pressures of 160 mm Hg or greater, and a sensitivity of 89% and specificity of 89% in detecting intraarterial systolic pressures of 100 mm Hg or less. These findings demonstrate differences between the oscillometric monitor and other standard methods of blood pressure measurement.(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
We observed the comparative serum levels and mean peak serum antistaphylococcal activity in eight fasting adults who received 500 mg each of dicloxacillin, cloxacillin, oxacillin, and nafcillin. Dicloxacillin achieved higher and more prolonged serum levels and greater peak serum antistaphylococcal titers than the other drugs studied. The higher degree of protein binding of dicloxacillin was reflected in a greater disparity between the peak antistaphylococcal activity observed when dilutions were done in serum compared to broth. The lesser protein-bound penicillins showed less disparity, but this effect was offset by the higher serum levels obtained by dicloxacillin. The higher protein binding of dicloxacillin did not prevent its having equal or superior antistaphylococcal activity in serum when the drugs were given in equal doses.
Explore the source record for details and available documents.
Explore the source record for details and available documents.