Blood flow estimation with harmonic Flash Echo Imaging.

Blood volume flow estimation remains an important task for the functional evaluation of internal organs. In vitro and in vivo flow estimation has been carried out using Flash Echo Imaging in harmonic mode after the administration of microbubble-based ultrasound contrast agents. The in vitro flow volume rate correlated with the constant replenishment level but less so with the video intensity decay rate. The in vivo volume flow rates obtained in four dogs agreed well with CVI-Q (time domain correlation) based flow measurement. Our experimental results indicate that the volume flow rate can be accurately estimated in vitro and in vivo using harmonic Flash Echo imaging.

Animals↗

Subharmonic imaging of contrast agents.

Ultrasound contrast agents promise to improve the sensitivity and specificity of diagnostic ultrasound imaging. It is of great importance to adapt ultrasound equipment for optimal use with contrast agents e.g., by exploiting the nonlinear properties of the contrast microbubbles. Harmonic imaging is one technique that has been extensively studied and is commercially available. However, harmonic imaging is associated with problems, due to second harmonic generation and accumulation within the tissue itself. Given the lack of subharmonic generation in tissue, one alternative is the creation of subharmonic images by transmitting at the fundamental frequency (fo) and receiving at the subharmonic (fo/2). Subharmonic imaging should have a much better lateral resolution and may be suitable for scanning deep-lying structures owing to the higher transmit frequency and the much smaller attenuation of scattered subharmonic signals. In this paper, we will review different aspects of subharmonic imaging including implementation, in-vitro gray-scale imaging and subharmonic aided pressure estimation.

Acoustics↗

Destruction of contrast microbubbles and the association with inertial cavitation.

The destruction of insonified Sonazoid microbubbles and its association with inertial cavitation in vitro utilizing an active acoustic detector was investigated. The experimental observation indicated that contrast microbubbles could be damaged at moderate acoustic pressures of 0.6-1.6 MPa (0.4-1.0 in mechanical index, MI). A damaged bubble could be dissolved into the medium on the order of 1 ms, implying that the destruction at moderate pressures is a relatively slow (relative to inertial bubble collapse), nonviolent dissolution process following the disruption of encapsulating surface materials. Inertial cavitation events in the presence of contrast microbubbles were observed using multiple highly intense ultrasound (US) pulses (>1.6 MPa). This observation suggested that intense US might disintegrate contrast microbubbles, and fragments of disintegrated microbubbles could be activated by an upcoming highly intense imaging pulse. The above results imply that inertial cavitation is unlikely to take place in the presence of Sonazoid contrast microbubbles when exposed to diagnostic US with an MI <1.

Contrast Media↗

Ultrasonic characterization of the nonlinear properties of contrast microbubbles.

The nonlinear properties of microbubble contrast agents have been used to create contrast-specific imaging modalities such as harmonic imaging and subharmonic imaging. Thus, a better understanding of the nonlinear performance of contrast microbubbles may enhance the diagnostic capabilities of medical ultrasound (US) imaging. The first and second harmonic, the 1/2 order subharmonic and the 3/2 order ultraharmonic components in spectra of scattered signals from Optison microbubbles insonified at 2 and 4 MHz have been investigated using an in vitro laboratory pulse-echo system. The development of these signal components over time is quite different for 2-MHz insonification compared to 4-MHz insonification. Scattered subharmonic and ultraharmonic signals are much more time-dependent than first and second harmonic echoes. The dependence of the first and second harmonic, subharmonic and ultraharmonic components on acoustic pressure for 2-MHz insonification is similar to that for 4-MHz insonification. The first and second harmonic components increase linearly with acoustic pressure (in double logarithmic scales) and the subharmonic and ultraharmonic amplitudes undergo rapid growths in the intermediate acoustic pressure range and much slower increases at both lower and higher acoustic pressures.

Albumins↗

Pressure dependence of subharmonic signals from contrast microbubbles.

Noninvasive pressure estimation in heart cavities and in major vessels would provide clinicians with a valuable tool for assessing patients with heart and vascular diseases. Some microbubble-based ultrasound contrast agents are particularly well suited for pressure measurements because their substantial compressibility enables microbubbles to vary significantly in size in response to changes in pressure. Pressure changes should then affect reflectivity of microbubbles after intravenous injection of a contrast agent. This has been demonstrated with a galactose-based contrast agent using 2.0-MHz ultrasound tone bursts. Preliminary results indicate that, over the pressure range of 0-186 mmHg, the subharmonic amplitude of scattered signals decreases by as much as 10 dB under optimal acoustic settings and the first and second harmonic amplitudes decrease by less than 3 dB. An excellent correlation between the subharmonic amplitude and the hydrostatic pressure suggests that the subharmonic signal may be utilized for noninvasive detection of pressure changes.

Contrast Media↗

Effect of filling gases on the backscatter from contrast microbubbles: theory and in vivo measurements.

Two surfactant-based contrast agents, ST44 and ST68, were produced according to US Patent # 5,352,436 and filled with either air, C4F10 (perfluorobutane) or SF6 (sulfur hexaflouride). Ten rabbits received i.v. injections of each agent/gas combination with 5 repetitions of each dose (range: 0.005-0.13 mL/kg). A custom-made 10-MHz cuff transducer was placed around the surgically exposed distal aorta and audio Doppler signals were acquired in vivo. Quantitative in vivo dose responses were calculated off-line using spectral power analysis and compared to a theoretical model of microbubble dissolution and enhancement. For qualitative comparisons, 10 rabbits were imaged pre- and postcontrast administration (dose: 0.1 mL/kg) in gray-scale and colour. All agent/gas combinations produced marked Doppler enhancement with air bubbles enhancing least of all (p < 0.0001) and ST68-SF6 best of all (maximum: 27.6 +/- 2.04 dB; p < 0.012). There were no significant differences between other agent/gas combinations (0.30 < p < 0.70). Theoretical enhancement was within 1 order of magnitude of the experimental observations (i.e., deviations of up to 10 dB). The duration of contrast enhancement was 1-2 min for air-filled bubbles, 3-5 min for SF6-filled bubbles and more than 7 min for C4F10-filled bubbles. In conclusion, ST68-SF6 microbubbles produced most in vivo enhancement of the agent/gas combinations studied. Theory matched the measurements within an order of magnitude.

Animals↗

Tissue-specific US contrast agent for evaluation of hepatic and splenic parenchyma.

PURPOSE: To evaluate the recently developed ultrasonographic (US) contrast agent SHU 563A, which is specifically taken up by the reticuloendothelial system (RES). MATERIALS AND METHODS: Color Doppler imaging (CDI) was performed in a gel phantom, with SHU 563A microbubbles in stationary suspension. CDI was performed in vivo in five woodchucks with natural hepatomas and in 12 rabbits before and after intravenous bolus injections of SHU 563A (0.16-0.48 mL/kg). After a 15-135-minute delay, the liver and spleen were scanned again, and the image findings were compared with pathologic analysis results. RESULTS: Phantom CDI demonstrated a random mosaic color pattern in spite of the lack of flow. This phenomenon, which is associated with bubble rupture, is termed induced acoustic emission. In vivo, delayed imaging demonstrated acoustic emission signals in normal parenchyma, whereas no mosaic color was seen in regions lacking reticuloendothelial cells (e.g., tumors). Four of 12 VX-2 tumors detected with pathologic analysis were detected with US alone; the remaining eight tumors were detected by using US with contrast agent (100%, P = .0078). Nine of 20 hepatomas were detected at baseline US, whereas 17 were detected after administration of SHU 563A (P = .0215). Acoustic emission enabled detection of hepatic tumors as small as 3 mm in diameter. CONCLUSION: CDI with SHU 563A demonstrates a random mosaic color pattern, even without flow. The characteristic appearance of acoustic emission signals provides a distinctive method of visualizing normal hepatic tissues and substantially improves the detectability of hepatic tumors.

Animals↗

Subharmonic imaging with microbubble contrast agents: initial results.

The subharmonic emission from insonified contrast microbubbles was used to create a new imaging modality called Subharmonic Imaging. The subharmonic response of contrast microbubbles to ultrasound pulses was first investigated for determining adequate acoustic transmit parameters. Subharmonic A-lines and gray scale images were then obtained using a laboratory pulse-echo system in vitro and a modified ultrasound scanner in vivo. Excellent suppression of all backscattered signals other than from contrast microbubbles was achieved for subharmonic A-lines in vitro while further optimization is required for in vivo gray scale subharmonic images.

Animals↗