Analysis of codeine, dihydrocodeine and their glucuronides in human urine by electrokinetic capillary immunoassays and capillary electrophoresis-ion trap mass spectrometry.

Screening for and confirmation of illicit, abused and banned drugs in human urine is a timely topic in which capillary separation techniques play a key role. Capillary electrophoresis (CE) represents the newest technology employed in this field of analysis. Two rapid competitive binding, electrokinetic capillary-based immunoassays are shown to be capable of recognizing the presence, but not the identity, of urinary opioids, namely codeine (COD), codeine-6-glucuronide, dihydrocodeine (DHC), dihydrocodeine-6-glucuronide, morphine (MOR), morphine-3-glucuronide and ethylmorphine (EMOR). In these approaches, aliquots of urine and immunoreagents of a commercial, broadly cross-reacting fluorescence polarization immunoassay for opiates were combined and analyzed by capillary zone electrophoresis or micellar electrokinetic capillary chromatography with laser induced fluorescence detection. With the fluorescent tracer solution employed, the former method is shown to provide simple electropherograms which are characterized by an opioid concentration dependent magnitude of the free tracer peak. In presence of dodecyl sulfate micelles, however, two tracer peaks with equal opioid concentration sensitivity are monitored. These data suggest the presence of two fluorescent tracers which react competitively with the urinary opioids for the binding sites of the antibody. Assay sensitivities for COD and MOR are comparable (10 ng/ml), whereas those for DHC and EMOR are about four-fold lower. Furthermore, glucuronides are shown to react like the corresponding free opioids. Analysis of urines that were collected after administration of 7 mg COD and 25 mg DHC tested positively in both assay formats. The presence of the free and conjugated codeinoids in these urines and their identification was accomplished by capillary electrophoresis-ion trap mass spectrometry (CE-MS). This confirmatory assay is based upon solid-phase extraction using a mixed-mode polymer cartridge followed by CE hyphenated to the LCQ mass spectrometer with electrospray ionization in the positive ion mode. With this technology, MS2 is employed for proper identification of COD (m/z 300.4) and DHC (m/z 302.4) whereas MS3 provides unambiguous identification of the glucuronides of COD (m/z 476.5) and DHC (m/z 478.5) via their fragmentation to COD and DHC, respectively. MSn (n > or = 2) is shown to be capable of properly identifying the urinary codeinoids on the 100-200 ng/ml concentration level.

Chromatography, Micellar Electrokinetic Capillary↗

Analysis of carnitine and acylcarnitines in urine by capillary electrophoresis.

A capillary electrophoresis method is described for the simultaneous analysis of carnitine and short-chain acylcarnitines in aqueous standard solutions and urine samples. Samples were worked up using silica gel extraction and derivatization with 4'-bromophenacyl trifluoromethanesulfonate. Separation was performed in less than 8 min using a binary buffer system containing phosphate/phosphoric acid and sodium dodecyl sulfate. 3-(2,2,2-Trimethylhydrazinium)propionate (mildronate) was used as an internal standard. The method was developed with aqueous standard solutions and then applied successfully to spiked and unspiked human urine samples. The limit of detection for both carnitine and acetylcamitine is 3 microM.

Carnitine↗

Enantioselective determination of drugs in body fluids by capillary electrophoresis.

During the past decade, chiral capillary electrophoresis (CE) emerged as a promising, effective and economic approach for the enantioselective determination of drugs in body fluids, hair and microsomal preparations. This review discusses the principles and important aspects of CE-based chiral bioassays, provides a survey of the assays developed and presents an overview of the key achievements encountered. Applications discussed encompass the pharmacokinetics of drug enantiomers, the elucidation of the stereoselectivity of drug metabolism and bioanalysis of drug enantiomers of toxicological and forensic interest.

Body Fluids↗

Confirmation testing of amphetamines and designer drugs in human urine by capillary electrophoresis-ion trap mass spectrometry.

Monitoring of amphetamines and designer drugs in human urine is a timely topic in clinical toxicology, surveillance of drug substitution, forensic science, drug testing at the workplace, and doping control. Confirmation testing of urinary amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) and 3,4-methylenedioxyamphetamine (MDA) by capillary electrophoresis (CE) combined with atmospheric pressure electrospray ionization and ion trap mass spectrometry (MS) is described. Using an aqueous pH 4.6 buffer composed of ammonium acetate/acetic acid, CE-MS and CE-MS2 provided data that permitted the unambiguous confirmation of these drugs in external quality control urines. Furthermore, other drugs of abuse present in alkaline urinary extracts, including methadone and morphine, could also be monitored. The data presented illustrate that the sensitivity achieved with the benchtop MS is comparable to that observed by CE with UV absorption detection. CE-MS2 is further shown to be capable of identifying comigrating compounds, including the comigration of amphetamine with nicotine.

Amphetamines↗

Therapeutic drug monitoring of albendazole: determination of albendazole, albendazole sulfoxide, and albendazole sulfone in human plasma using nonaqueous capillary electrophoresis.

A nonaqueous capillary electrophoretic method (NACE) for the fast determination of plasma levels of albendazole (ABZ), albendazole sulfoxide (ABZSO), and albendazole sulfone (ABZSO2) is described. The assay is based upon liquid/liquid extraction of these compounds using dichloromethane at pH 10.2 (recovery between 63 and 98%), followed by a NACE separation performed within 8 min employing a 0.036 M borate buffer (apparent pH 9.9) in a mixture of methanol and N-methylformamide (1:3) and on-column absorbance detection at 280 nm. Using 0.5 mL of plasma and extract reconstitution in 200 microL N-methylformamide, drug levels between 1.0-10 microM were found to provide linear calibration graphs. Intraday and interday imprecisions evaluated from peak area ratios (n = 5) were <10% and <12%, respectively. Corresponding imprecisions of detection times (n = 5) were <1% and <6%, respectively. The limit of detection (LOD) for ABZ, ABZSO and ABZSO2 was 8 x 10(-7) M. The reliability of the method developed was verified via analysis of 45 plasma samples obtained from patients treated with ABZ. Good agreement was obtained between the levels of ABZSO and those determined by routine HPLC. ABZ was found to be undetectable in all patient samples, whereas the levels of ABZSO2 were below or close to LOD.

Albendazole↗

Sample self-stacking in capillary zone electrophoresis: behavior of samples containing multiple major coionic components.

It is a frequent phenomenon in practice that a sample contains bulk levels of more than one coionic component that affect the stacking behavior of minor analytes and in this way also the sensitivity of the method. Here, attention is paid to stacking resulting from the presence of a macrocomponent of leading type that is deteriorated by the presence of another macrocomponent of like charge in the sample. Based on the isotachophoretic model of migration in the initial period of separation, a theoretical approach was elaborated both for strong and weak electrolytes which describes the separation process and finds the conditions that define whether transient isotachophoretic stacking of the analyte takes place or not. It is shown that the crucial parameter is the ratio of the concentrations of macrocomponents migrating in front and behind the analyte of interest. The destacking effect can also be expected when the coion of the background electrolyte is present in the sample. Rules how to cope with effects of destackers present in the sample are given. Theoretical considerations are illustrated by computer simulations and verified experimentally. Examples of antagonistic effects of macrocomponents are demonstrated for model serum samples.

Electrophoresis, Capillary↗

Head-column field-amplified sample stacking in binary system capillary electrophoresis. Preparation of extracts for determination of opioids in microliter amounts of body fluids.

Head-column field-amplified sample stacking (head-column FASS) is an efficient, on-line sample concentration technique that can easily provide a sensitivity enhancement of three orders of magnitude. Application of head-column FASS to the capillary electrophoretic analysis of opioid extracts prepared from 20 to 100 microliters of human plasma, serum or urine is reported. In the described approach, efficient concentration of cationic opiates from low conductivity extracts of body fluids is effected across a water plug, with separation taking place in a binary buffer comprising 60% (v/v) ethylene glycol, 75 mM Na2HPO4 and 25 mM NaH2PO4 (pH 7.9), and detection is effected at 210 nm. Sample extracts are prepared in 55% (v/v) ethylene glycol containing 100 microM H3PO4. Application of mixed-mode polymer solid-phase resins is shown to provide extracts that are either too salty or contain quite a large number of endogenous substances that could interfere with certain opioids. Liquid-liquid extraction with hexane, dichloromethane, ethyl acetate and dichloromethane-isopropanol is shown to provide extracts that are sufficiently clean. At a given pH, however, only closely related opioids can be extracted. Using ethyl acetate at alkaline pH, dihydrocodeine and nordihydrocodeine can reproducibly be recovered from 20-100 microliters of plasma, serum and urine. Application of head-column FASS and UV absorption detection thereby leads to the determination of ppb concentrations (> or = 1 ng/ml) of these compounds, an approach that only requires microliter amounts of sample and organic solvents.

Body Fluids↗

Characterization of the stereoselective metabolism of thiopental and its metabolite pentobarbital via analysis of their enantiomers in human plasma by capillary electrophoresis.

Using capillary zone electrophoresis (CZE) with a 75 mM phosphate buffer at pH 8.5 containing 5 mM hydroxypropyl-gamma-cyclodextrin (OHP-gamma-CD) as chiral selector, the separation of the enantiomers of thiopental and its oxybarbiturate metabolite, pentobarbital, is reported. Enantiomer assignment was performed via preparation of enantiomerically enriched fractions using chiral recycling isotachophoresis (rITP) processing of racemic barbiturates and analysis of rITP fractions by chiral CZE and circular dichroism spectroscopy. Thiopental and pentobarbital enantiomers in plasma were extracted at low pH using dichloromethane and extracts were reconstituted in acetonitrile or 10-fold diluted, achiral running buffer. The stereoselectivity of the thiopental and pentobarbital metabolism was assessed via analysis of 12 plasma samples that stemmed from patients undergoing prolonged or having completed long-term racemic thiopental infusion. The data obtained revealed a modest stereoselectivity with R-(+)-thiopental/S-(-)-thiopental and R-(+)-pentobarbital/S-(-)-pentobarbital plasma ratios being < 1 (P < 0.05 compared to data obtained with racemic controls) and > 1 (P < 0.001), respectively. The total S-(-)-thiopental plasma concentration was found to be on average about 24% higher compared to the concentration of R-(+)-thiopental, whereas the total R-(+)-pentobarbital plasma level was observed to be on average 29% higher compared to the S-(-)-pentobarbital concentration.

2-Hydroxypropyl-beta-cyclodextrin↗

Analysis of urinary drugs of abuse by a multianalyte capillary electrophoretic immunoassay.

This paper characterizes a novel multianalyte competitive binding, electrokinetic capillary-based immunoassay for urinary methadone, opiates, benzoylecgonine (cocaine metabolite) and amphetamines. After incubation of 25 microliters urine with the reactants for several minutes in the presence of an internal standard, a small aliquot of the mixture is applied onto a fused-silica capillary and the unbound fluorescein labelled drug tracers are monitored by capillary electrophoresis with on-column laser induced fluorescence detection. The multianalyte assay is shown to be rapid, simple, quantitative, capable of recognizing urinary drug concentrations > or = 30 ng/ml and suitable for screening of patient urines. Data are demonstrated to compare well with those obtained by routine screening methods based on enzyme multiplied immunoassay techniques and fluorescence polarization immunoassays. The electrokinetic capillary assay has been validated via analysis of external quality control urines and confirmation analysis of patient urines using GC-MS.

Amphetamines↗

Stereoselective screening for and confirmation of urinary enantiomers of amphetamine, methamphetamine, designer drugs, methadone and selected metabolites by capillary electrophoresis.

Data presented in this paper demonstrate that a competitive binding, electrokinetic capillary-based immunoassay previously used for screening of urinary amphetamine and analogs cannot be employed to distinguish between the enantiomers of amphetamine and methamphetamine. However, capillary zone electrophoresis with a pH 2.5 buffer containing (2-hydroxypropyl)-beta-cyclodextrin as chiral selector is shown to permit the enantioselective analysis of urinary extracts containing methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (Ecstasy) and other designer drugs, and methadone together with its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine. In that approach, enantiomer identification is based upon comparison of extracted polychrome UV absorption data and electropherograms obtained by rerunning of spiked extracts with spectra and electropherograms monitored after extraction of fortified blank urine. The suitability of the described chiral electrokinetic capillary method for drug screening and confirmation is demonstrated via analysis of unhydrolyzed quality control urines containing a variety of drugs of abuse. Furthermore, in a urine of a patient under selegiline pharmacotherapy, the presence of the R-(-)-enantiomers of methamphetamine and amphetamine could be unambiguously identified. Direct intake of an R-enantiomer or ingestion of drugs that metabolize to the R-enantiomers can be distinguished from the intake of S-(+)-enantiomers (drug abuse) or prescribed drugs that metabolize to the S-enantiomers of methamphetamine and amphetamine. The described approach is simple, reproducible, inexpensive and reliable (free of interferences of other major basic drugs that are frequently found in toxicological urines) and could thus be used for screening for and confirmation of urinary enantiomers in a routine laboratory.

Amphetamine↗

Capillary electrophoresis in clinical and forensic analysis: recent advances and breakthrough to routine applications.

This paper is a comprehensive review article on capillary electrophoresis (CE) in clinical and forensic analysis. It is based upon the literature of 1997 and 1998, presents CE examples in major fields of application, and provides an overview of the key achievements encountered, including those associated with the analysis of drugs, serum proteins, hemoglobin variants, and nucleic acids. For CE in clinical and forensic analysis, the past two years witnessed a breakthrough to routine applications. As most coauthors of this review are associated with diagnostic or forensic laboratories now using CE on a routine basis, this review also contains data from routine applications in drug, protein, and DNA analysis. With the first-hand experience of providing analytical service under stringent quality control conditions, aspects of quality assurance, assay specifications for clinical and forensic CE and the pros and cons of this maturing, cost-and pollution-controlled age technology are also discussed.

Electrophoresis, Capillary↗

Efficacies of albendazole sulfoxide and albendazole sulfone against In vitro-cultivated Echinococcus multilocularis metacestodes.

The metacestode stage of Echinococcus multilocularis is the causative agent of alveolar echinococcosis (AE), a parasitic disease affecting the liver, with occasional metastasis into other organs. Benzimidazole carbamate derivatives such as mebendazole and albendazole are currently used for chemotherapeutic treatment of AE. Albendazole is poorly resorbed and is metabolically converted to its main metabolite albendazole sulfoxide, which is believed to be the active component, and further to albendazole sulfone. Chemotherapy with albendazole has been shown to have a parasitostatic rather than a parasitocidal effect; it is not effective in all cases, and the recurrence rate is rather high once chemotherapy is stopped. Thus, development of new means of chemotherapy of AE is needed. This could include modifications of benzimidazoles and elucidiation of the respective biological pathways. In this study we performed in vitro drug treatment of E. multilocularis metacestodes with albendazole sulfoxide and albendazole sulfone. High-performance liquid chromatography analysis of vesicle fluids showed that the drugs were taken up rapidly by the parasite. Transmission electron microscopic investigation of parasite tissues and nuclear magnetic resonance spectroscopy of vesicle fluids demonstrated that albendazole sulfoxide and albendazole sulfone had similar effects with respect to parasite ultrastructure and changes in metabolites in vesicle fluids. This study shows that the in vitro cultivation model presented here provides an ideal first-round test system for screening of antiparasite drugs.

Albendazole↗

Capillary electrophoresis in clinical toxicology.

During the past decade, capillary electrophoresis (CE) emerged as a promising, effective and economic approach for separation of a large variety of substances, including those encountered in clinical toxicology. Reliable and automated CE instruments became commercially available and promoted the exploration of an increasing number of CE methods for illicit and licit drugs in body fluids. The widespread applicability of CE, its enormous separation power and high-sensitivity detection schemes make this technology an attractive and promising tool. This review provides an overview of the key achievements encountered with CE in clinical toxicology, including (i) the rapid assessment of drug intoxications via direct sample injection, (ii) the screening for and determination of illicit and licit drugs in body fluids with drug extraction, drug concentration (stacking) and chiral discrimination, (iii) the application of immunological single and multianalyte assays in the capillary format to the screening for drugs in body fluids, and (iv) drug confirmation by on-column multiwavelength absorbance and fluorescence detection and/or CE coupled to mass spectrometry. With its distinct features (automation, small sample size, minimal sample preparation, requirement of almost no organic solvents, ease of buffer change and method development, speed of analysis, low cost of capillaries and chemicals) CE has a bright future and the twenty-first century will witness the widespread use of a large number of simple and reliable CE based assays for drugs, methods that will be employed in clinical toxicology, therapeutic drug monitoring and forensic science.

Body Fluids↗

Determination of naproxen in liver and kidney tissues by electrokinetic capillary chromatography with laser-induced fluorescence detection.

Pharmacotherapy through the targeting of drugs is a promising new approach that requires adequate analytical methods capable of monitoring the free drug, the drug carrier and metabolites in body fluids and organs. A micellar electrokinetic capillary chromatography (MECC) based assay for analysis of naproxen (NAP) in extracts of hydrolyzed liver and kidney tissue homogenates using salicylate as internal standard and solute detection by laser-induced fluorescence is reported. The assay described uses 100 microliters of hydrolyzed tissue homogenate and has a detection limit of 0.07 microgram/ml. It is shown to be selective, reproducible (at a NAP level of 0.25 microgram/ml, intra-day and inter-day R.S.D. values are 3.73% and 6.39%, respectively), simple and economical (operates with inexpensive separation columns and small amounts of chemicals). It has been successfully applied to the assessment of the total NAP content within liver and kidney tissues of male Sprague Dawley rats that have been treated with NAP conjugated to human serum albumin (the drug targeting carrier) and free NAP. Compared to previously applied techniques, including high-performance liquid chromatography, MECC offers the advantage of having lower running costs and lower consumption of organic solvents.

Animals↗

Head-column field-amplified sample stacking in binary system capillary electrophoresis. 2. Optimization with a preinjection plug and application to micellar electrokinetic chromatography.

In capillary electrophoresis, head-column field-amplified sample stacking (FASS) provides the largest sensitivity enhancement of all electrokinetic concentration techniques (Zhang, C.-X.; Thormann, W. Anal. Chem. 1996, 68, 2523). Application of head-column FASS to the analysis of closely related opioids by capillary zone electrophoresis in binary systems with ethylene glycol is described. It is shown that sample condensation is further increased about 2-fold by introduction of a preinjection plug, i.e., introduction of a short solution plug of high conductivity, high pH, and high viscosity at the capillary tip prior to injection. The preinjection plug acts as a temporary trap for solutes. Its effective length is shown to be limited to a few millimeters. The highest sample stacking efficiency in head-column FASS is obtained via optimization of the electric field strength and the effective electrophoretic mobility of the solutes within the sample and the adjacent zones and is thus strongly dependent on the compositions of both the sample matrix and the preinjection plug. Binary sample solutions of low conductivity and low viscosity containing small amounts of a weak acid are demonstrated to be most effective for the stacking of positively charged opioids. The procedure developed for capillary zone electrophoresis of opioids in binary systems with ethylene glycol and UV absorbance detection is documented to provide a 3 orders of magnitude sensitivity enhancement, exhaustive sample injection from an external reservoir of up to 20 microL (i.e., from a volume that is more than 20-fold the volume of the capillary employed), and a lowest detectable concentration of 0.1 ng/mL (S/N = 3). Using internal calibration, typical intraday and interday imprecisions of solute concentrations between 3 and 10 ng/mL and between 0.5 and 1.5 ng/mL are < or = 5% and < or = 15%, respectively. The stacking approach has been successfully applied to the analysis of dihydrocodeine in extracts of 20 microL of human plasma and is shown to permit the precise (imprecision < or = 10%) determination of dihydrocodeine plasma levels of pharmacological interest (3-300 ng/mL or 10-1000 nM). Furthermore, using a modified protocol for micellar electrokinetic chromatography, head-column FASS is shown to provide a 400-fold sensitivity enhancement for a number of opioids. The stacking procedure is based on insertion of a surfactant-free preinjection plug and temporary application of reversed voltage after electroinjection.

Analgesics, Opioid↗

Screening for urinary methadone by capillary electrophoretic immunoassays and confirmation by capillary electrophoresis-mass spectrometry.

This paper characterizes competitive binding, electrokinetic capillary-based immunoassays for urinary methadone using reagents which were commercialized for a fluorescence polarization immunoassay. After incubation of 25 microL urine with the reactants, a small aliquot of the mixture is applied onto a fused-silica capillary and the unbound fluorescein-labeled methadone tracer is monitored by capillary electrophoresis with on-column laser-induced fluorescence detection. Configurations in presence and absence of micelles were investigated, found to be capable of recognizing urinary methadone concentrations > or = 10 ng/mL, and shown to be suitable for rapid methadone screening of patient urines. Based upon shorter run times and a much better separation of free tracer and antibody-tracer complex, conditions without micelles are preferred. For confirmation analysis of urinary methadone and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), capillary electrophoresis in a pH 4.6 ammonium acetate-acetic acid buffer was interphased to an atmospheric pressure ionization triple quadrupole mass spectrometry system. Using positive ion electrospray ionization and the tandem mass spectrometry mode with collision-induced dissociation in the collision cell, fragmentation of the two substances was determined. For confirmation via direct urine injection or application of a urinary extract, in-source fragmentation was employed and the first quadrupole was operated in the selected ion monitoring mode by switching between the masses of relevant precursor/product ion sets for methadone (m/z = 310, 265) and EDDP (m/z = 278, 249, 234). This capillary electrophoresis-mass spectrometry approach is shown to permit the confirmation of methadone and EDDP in patient urines that tested positive for methadone using electrokinetic capillary-based immunoassays, a fluorescence polarization immunoassay, and capillary electrophoresis with UV absorption detection.

Electrophoresis, Capillary↗

Enantiomeric separation of methadone by cyclodextrin-based capillary and recycling isotachophoresis.

The separation of methadone enantiomers by cationic capillary isotachophoresis (CITP) and recycling isotachophoresis (RITP) having (2-hydroxypropyl)-beta-cyclodextrin (OHP-beta-CD) as chiral selector in the leading electrolyte is described. Sodium acetate/acetic acid (pH between 4 and 5) served as leading electrolyte (catholyte) and acetic acid as terminator (anolyte). Complete separation of the enantiomers was obtained by CITP in a 50 microm internal diameter (ID) fused-silica capillary and in a 500 microm ID Teflon capillary. In the first approach, enantiomeric separation could be monitored via UV absorbance detection at low wavelength. With the second instrumental setup, an additional conductivity sensor permitted the visualization of the enantiomeric separation and the characterization of the buffer system employed. A 10 mM sodium acetate/acetic acid leading buffer of pH 4.3, containing 5 mM OHP-beta-CD, was found to provide best enantiomeric separation and was thus chosen for RITP. With RITP processing of a few mg of racemic methadone, partial separation of methadone enantiomers was obtained. R-(-)-methadone and S-(+)-methadone were found to be significantly (up to about 80%) enriched at the front and back side, respectively, of the isotachophoretic zone. The enantiomeric composition of methadone in the collected fractions was assessed by chiral capillary zone electrophoresis (CZE) and circular dichroism spectroscopy. CZE was found to represent a simple and efficient method for the determination of the enantiomeric excess, whereas the latter technology was noted to be the superior approach for properly characterizing fractions that contain similar amounts of the two enantiomers. Furthermore, chiral RITP and analysis of the collected fractions by circular dichroism spectroscopy is shown to be potentially useful for identification of single enantiomers in absence of pure chiral standards.

Circular Dichroism↗

Capillary electrophoresis in drug analysis.

Capillary electrophoresis has become one of the advanced analytical methods for drugs in pharmaceutical, therapeutic, diagnostic and forensic applications. This review discusses key issues and provides key references to the topic of drug analysis using capillary electrophoresis. It gives readers a brief summary of the current status of the technology and serves as an editorial for the paper symposium "Capillary electrophoresis in drug analysis".