PubMed Health⌕ Search

Biomedical subjects

W Van Thuyne

Publications and source records attributed to W Van Thuyne.

8 recordsLinked to original sources

Evidence of natural hybridization and introgression between Vasconcellea species (Caricaceae) from southern Ecuador revealed by chloroplast, mitochondrial and nuclear DNA markers.

BACKGROUND AND AIMS: Vasconcellea x heilbornii is believed to be of natural hybrid origin between V. cundinamarcensis and V. stipulata, and is often difficult to discriminate from V. stipulata on morphological grounds. The aim of this paper is to examine individuals of these three taxa and of individuals from the closely related species V. parviflora and V. weberbaueri, which all inhabit a hybrid zone in southern Ecuador. METHODS: Molecular data from mitochondrial, chloroplast and nuclear DNA from 61 individuals were analysed. KEY RESULTS: Molecular analysis confirmed occasional contemporary hybridization between V. stipulata, V. cundinamarcensis and V. x heilbornii and suggested the possible involvement of V. weberbaueri in the origin of V. x heilbornii. In addition, the molecular data indicated unidirectional introgression of the V. cundinamarcensis nuclear genome into that of V. stipulata. Several of the individuals examined with morphology similar to that of V. stipulata had genetic traces of hybridization with V. cundinamarcensis, which only seems to act as pollen donor in interspecific hybridization events. Molecular analyses also strongly suggested that most of the V. x heilbornii individuals are not F(1) hybrids but instead are progeny of repeated backcrosses with V. stipulata. CONCLUSIONS: The results of the present study point to the need for re-evaluation of natural populations of V. stipulata and V. x heilbornii. In general, this analysis demonstrates the complex patterns of genetic and morphological diversity found in natural plant hybrid zones.

Caricaceae↗

Distribution of caffeine levels in urine in different sports in relation to doping control before and after the removal of caffeine from the WADA doping list.

Caffeine concentrations were measured in the urine of 4633 athletes tested for doping control in the Ghent Doping Control Laboratory in 2004. Determination of these concentrations was done using an alkaline extraction with a mixture of dichloromethane and methanol (9 : 1; v/v) followed by high performance liquid chromatography and ultraviolet detection (HPLC-UV). The method was validated according to ISO 17 025 standards (International Organisation for Standardisation). Quantification was done by using a linear calibration curve in the range from 0 to 20 microg/ml. The limit of quantification (LOQ) was 0.10 microg/ml. Because the results were not normally distributed, transformation of the data was done to evaluate the difference in detected concentrations in several sports. This resulted in an overall average concentration of 1.12 +/- 2.68 microg/ml. Comparison of the most frequently tested sports in 2004 demonstrated that caffeine concentrations in samples originating from power lifters are significantly higher in comparison to urines taken in other sports. Also, a significant difference between caffeine concentrations found in cycling and concentrations found in other sports, including athletics and some ball sports, was observed. A comparison was made between results obtained in 2004 and results obtained before the removal of caffeine from the WADA (World Anti-Doping Agency) doping list indicating that average caffeine concentrations decreased after the withdrawal of caffeine from the list of prohibited substances. The overall percentage of positive samples between the two periods remained the same although the percentage of positive samples noticed in cycling increased after the removal of caffeine from the doping list.

Bicycling↗

Quantitative analysis of androst-4-ene-3,6,17-trione and metabolites in human urine after the administration of a food supplement by liquid chromatography/ion trap-mass spectrometry.

6-OXO, a new nutritional supplement commercially available on the internet, is sold as an aromatase-inhibitor and contains androst-4-ene-3,6,17-trione as active ingredient. This anabolic steroid is a prohibited substance in sports. Androst-4-ene-3,6,17-trione is metabolised to androst-4-ene-6alpha-ol-3,17-dione and androst-4-ene-6alpha,17beta-diol-3-one. A fast, sensitive and accurate LC/MS method was developed and validated for the quantification of androst-4-ene-3,6,17-trione and its metabolites in urine. The method is capable of determining the stereochemical position of the hydroxy-group at C-6 of the metabolites and consists of a liquid-liquid extraction step with diethylether after enzymatic hydrolysis, followed by separation on a reversed phase column. Ionisation of the analytes is carried out using atmospheric pressure chemical ionisation. The limit of quantification of the method was 5 ng/mL for all compounds. The accuracy ranged from 14.8 to 1.3% for androst-4-ene-3,6,17-trione, 9.4 to 1.6% for androst-4-ene-6alpha-ol-3,17-dione and 4.1 to 3.2% for androst-4-ene-6alpha,17beta-diol-3-one in the range of 5-1000 ng/mL. Using this method androst-4-ene-6alpha-ol-3,17-dione was identified as a major urinary metabolite, whereas androst-4-ene-6alpha,17beta-diol-3-one as a minor metabolite. While the parent compound is predominantly excreted in conjugated form, both metabolites are solely excreted as conjugates.

Adult↗

Detection of androst-4-ene-3,6,17-trione (6-OXO) and its metabolites in urine by gas chromatography-mass spectrometry in relation to doping analysis.

The metabolism and excretion of androst-4-ene-3,6,17-trione after administration of the 'nutritional' supplement 6-OXO was investigated by gas chromatography-mass spectrometry (GC-MS) in full-scan mode. The parent drug androst-4-ene-3,6,17-trione and androst-4-ene-6alpha,17beta-diol-3-one and androst-4-ene-6alpha-ol-3,17-dione were detected in the post-administration urine samples. Because androst-4-ene-3,6,17-trione is an anabolic steroid and an aromatase inhibitor, this substance is regarded as a doping agent. Hence, a selective and sensitive GC-MS method in selected ion monitoring mode for the detection of the TMS-enol-TMS-ether derivatives of these substances was developed and validated for doping control purposes. The limit of detection (LOD) of the investigated compounds ranged from 5 to 10 ng/mL. Using this method, the detection time for androst-4-ene-3,6,17-trione and androst-4-ene-6alpha,17beta-diol-3-one was 24 h, while androst-4-ene-6alpha-ol-3,17-dione could be detected up to 37 h after administration of the dose recommended by the manufacturer.

Adult↗

Distribution of caffeine levels in urine in different sports in relation to doping control.

Caffeine concentrations were measured in the urines of 11 361 athletes tested for doping control in the Ghent doping control laboratory during the period 1993 - 2002. Determination of these concentrations was done using an alkaline extraction with a mixture of dichloromethane and methanol (9:1; v/v) followed by high performance liquid chromatography and ultraviolet detection (HPLC-UV). The method was validated according to ISO 17 025 standards (International Organisation for Standardisation). Quantification was done by using a calibration curve in the range from 0 to 20 microg/ml. The limit of quantification (LOQ) was 0.10 microg/ml. Most caffeine concentrations were far below 12 microg/ml. Because the results were not normally distributed, transformation of the data was done to evaluate the difference in detected concentrations in several sports. This resulted in an overall average concentration of 1.22 microg/ml +/- 2.45 microg/ml. Comparison of those sports with more than 200 samples being analysed demonstrated that caffeine concentrations in urine samples from bodybuilders are significantly higher in comparison to urines taken in the other sports. Also, a significant difference between caffeine concentrations found in cycling and concentrations found in other sports, including athletics and some ball sports, was observed.

Bicycling↗

Validation of a GC-MS screening method for anabolizing agents in aqueous nutritional supplements.

A sensitive and selective method for the screening of anabolizing agents in aqueous nutritional supplements is described and validated. A total of 28 different anabolizing agents are screened for, including testosterone and prohormones, nandrolone and prohormones, stanozolol, and metandienone. The different analytes are extracted from the aqueous nutritional supplements by liquid-liquid extraction with a mixture of pentane and freshly distilled diethylether (1:1) after the supplements have been made alkaline with a NaHCO3-K2CO3 (2:1) buffer. The anabolizing agents are derivatized with a mixture of MSTFA-NH4I-ethanethiol (320:1:2) as routinely used for the screening of anabolic steroids extracted from urine. The derivatives are analyzed by gas chromatography (GC)-mass spectrometry (MS) in the selective ion monitoring mode. The limits of detection range from 1 to 10 ng/mL. One aqueous nutritional supplement (creatine serum) was analyzed with this screening method and was found to contain dehydroepiandrosterone (DHEA) at very low concentrations. The presence of DHEA could be confirmed with GC-MS-MS. Results of the application of this method and a similar method for solid nutritional supplements previously described are given.

Anabolic Agents↗

Validation of a GC-MS screening method for anabolizing agents in solid nutritional supplements.

A sensitive and selective method for the screening of 28 different compounds including testosterone and prohormones, nandrolone and prohormones, stanozolol and metandienone in solid nutritional supplements is described and validated. The different substances are extracted from the solid nutritional supplements by liquid-liquid extraction with a mixture of pentane and freshly distilled diethylether (9/1) after dissolving the supplement in NaOH (1 N). The anabolizing agents are derivatized with a mixture of MSTFA/NH(4)I/ethanethiol (320/1/2), routinely used for the derivatization of anabolic steroids extracted from urine. The TMS-derivatives are analysed by GC-MS in the SIM mode. The limits of detection were in the range from 2 to 40 ng/g. One supplement was analysed with this method and was found to contain several forbidden substances according to IOC doping regulations. All detected compounds, except dihydrotestosterone, could be confirmed with GC-MS(2), proving that the proposed method is suitable for the screening of anabolizing agents in solid nutritional supplements.

Anabolic Agents↗

Urinary concentrations of morphine after the administration of herbal teas containing Papaveris fructus in relation to doping analysis.

A quantitative method for the analysis of morphine in human urine in the concentration range between 0.25 and 2 microg/ml is described and validated. Morphine was determined after enzymatic hydrolysis of the urine. After liquid-liquid extraction with dichloromethane-methanol (9:1) at pH 9.5, morphine was derivatized with N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA) and analyzed with GC-MS (full scan). The limit of quantification of the method was 0.25 microg/ml. Two Papaveris fructus containing herbal teas were administered to five male volunteers and urine samples were taken quantitatively during the first 12 h after the administration. The morphine concentration in the tea was 10.4 and 31.5 microg/ml, respectively. Morphine was detected in the urine of all volunteers by 1 h after drinking the tea. Maximum morphine concentrations, 4.3 and 7.4 microg/ml, respectively, were obtained 4-6 h after administration. Doping positive urine samples were delivered for 1-9 h.

Adult↗