Biocompatibility of electrophoretical deposition of nanostructured hydroxyapatite coating on roughen titanium surface: in vitro evaluation using mesenchymal stem cells.

A nano hydroxyapatite (HAp) layer was coated on a roughen titanium surface by means of electrophoretic deposition with an acetic anhydride solvent system. The objectives of this current study are to investigate whether nano-HAp can improve mechanical strength at a lower sintering temperature and biocompatibility. Densification temperature was lowered from usual 1000 to 800 degrees C. The coating interfacial bonding strength, phase purity, microstructure, and biocompatibility were investigated. Degradation of HA phase was not detected in XRD. A porous TiO2 layer acts as a gradient coating layer with an intermediate thermal expansion coefficient between hydroxyapatite and titanium that reduces the thermal stress. From SEM image, the coating does not contain any crack. Mesenchymal stem cell (MSC) is the progenitor cell for various tissues in mature animals, which can improve integration of bone tissue into implant. In this in vitro study, rabbit MSCs culture indicated that the HAp/Ti nanocomposite biomaterial had good biocompatibility and bioactivity. Around materials and on its surface cell grew well with good morphology. Proliferation of the MSCs on the nano-HAp coating was higher than its micron counterpart in XTT assay. These properties show potential for the orthopaedic and dental applications.

Animals↗

Osteoprecursor cell response to strontium-containing hydroxyapatite ceramics.

The objective of this study was to investigate the in vitro bioactivity of strontium-containing hydroxyapatite (Sr-HA), and its effect on cellular attachment, proliferation, and differentiation. The effect of Sr-HA has been compared with that of hydroxyapatite (HA), which is widely used in orthopedics and dentistry. Sr-HA ceramic containing 10 mol % was prepared. The bioactivity of Sr-HA was evaluated in vitro by immersion in simulated body fluid (SBF). After immersion in SBF, Sr-HA exhibited greater ability to induce apatite precipitation on its surface than did HA. The possible effects on cell behavior of Sr-HA were examined by culturing osteoprecursor cells (OPC1) on materials surfaces. Cell shape and cell-material interactions were analyzed by scanning electron microscope (SEM) and the MTT assay was used to determine cell proliferation on samples. When compared with HA, Sr-HA promoted better OPC1 cell attachment and proliferation, and showed no deleterious effects on extracellular matrix formation and mineralization. Confocal scanning microscopy was used to assess the expression of specific osteoblast proteins: alkaline phosphatase (ALP) and osteopontin (OPN). The results obtained indicate that the presence of Sr stimulates OPC1 cell differentiation, and enhances ALP and OPN expression.

Alkaline Phosphatase↗

Osteogenic behavior of alginate encapsulated bone marrow stromal cells: an in vitro study.

Sodium alginate is a useful polymer for the encapsulation and immobilization of a variety of cells in tissue engineering because it is biocompatible, biodegradable and easy to process into injectable microbeads. Despite these properties, little is known of the efficacy of calcium cross-linked alginate gel beads as a biodegradable scaffold for osteogenic cell proliferation and differentiation. In this study, we investigated the ability of rabbit derived bone marrow cells (BMCs) to proliferate and differentiate in alginate microbeads and compared them with BMCs cultured in poly-L-lysine (PLL) coated microbeads and on conventional 2D plastic surfaces. Results show that levels of proliferation and differentiation in microbeads and on tissue culture plastics were comparable. Cell proliferation in microbeads however diminished after fortification with a coating layer of PLL. Maximum cell numbers observed were, 3.32 x 10(5) +/- 1.72 x 103; 3.11 x 10(5) +/- 1.52 x 10(3) and 3.28 x 10(5) +/- 1.21 x 10(3 ) for the uncoated, PLL coated and plastic surface groups respectively. Alkaline phosphatase and protein expressions reflected the stage of cell differentiation. We conclude that calcium cross-linked alginate microbeads can act as a scaffold for BMC proliferation and osteogenic differentiation and has potential for use as 3D degradable scaffold.

Alginates↗

Chemical composition, crystal size and lattice structural changes after incorporation of strontium into biomimetic apatite.

Recently, strontium (Sr) as ranelate compound has become increasingly popular in the treatment of osteoporosis. However, the lattice structure of bone crystal after Sr incorporation is yet to be extensively reported. In this study, we synthesized strontium-substituted hydroxyapatite (Sr-HA) with different Sr content (0.3%, 1.5% and 15% Sr-HA in mole ratio) to simulate bone crystals incorporated with Sr. The changes in chemical composition and lattice structure of apetite after synthetic incorporation of Sr were evaluated to gain insight into bone crystal changes after incorporation of Sr. X-ray diffraction (XRD) patterns revealed that 0.3% and 1.5% Sr-HA exhibited single phase spectrum, which was similar to that of HA. However, 15% Sr-HA induced the incorporation of HPO4(2-) and more CO3(2-), the crystallinity reduced dramatically. Transmission electron microscopy (TEM) images showed that the crystal length and width of 0.3% and 1.5% Sr-HA increased slightly. Meanwhile, the length and width distribution were broadened and the aspect ratio decreased from 10.68+/-4.00 to 7.28+/-2.80. The crystal size and crystallinity of 15% Sr-HA dropped rapidly, which may suggest that the fundamental crystal structure is changed. The findings from this work indicate that current clinical dosage which usually results in Sr incorporation of below 1.5% may not change chemical composition and lattice structure of bone, while it will broaden the bone crystal size distribution and strengthen the bone.

Biocompatible Materials↗

In vitro evaluation of alginate encapsulated adipose-tissue stromal cells for use as injectable bone graft substitute.

This study aims to investigate the survival and osteogenic behavior of murine-derived adipose-tissue stromal cells (ATSCs) encapsulated in alginate microcapsules thereby instigating further studies in this cell delivery strategy for in vivo osteogenesis. Cell viability was quantified using a tetrazolium-based assay and osteogenic differentiation was evaluated by both alkaline-phosphatase (ALP) histochemistry and osteocalcin mRNA analysis. Following microencapsulation, cell numbers increased from 3.9 x 10(3) on day 1 to 7.8 x 10(3) on day 7 and maintained excellent viability in the course of 21-day culture. ALP was 6.9, 5.5, and 3.2 times higher than monolayer cultures on days 7, 14, and 21, respectively. In addition, osteocalcin mRNA was detectable in encapsulated cultures earlier (day 14) than monolayer cultures. We conclude that alginate microcapsules can act as three-dimensional matrix for ATSC proliferation and has potential for use as injectable, biodegradable scaffold in bone tissue engineering.

Adipocytes↗

Interfacial behaviour of strontium-containing hydroxyapatite cement with cancellous and cortical bone.

The bone-bonding behaviors of various biomaterials have been extensively investigated. However, the precise mechanisms of bone bonding have not yet been clarified, and the differences in interfacial behaviors of biomaterial bonding with cancellous bone and cortical bone have not yet been understood. In this study, strontium-containing hydroxyapatite (Sr-HA) cement, in which 10% calcium ions were substituted by strontium, was performed in a rabbit hip replacement model. Six months later, the morphology and chemical composition of interfaces between Sr-HA cement with cancellous bone and cortical bone were evaluated by field emission scanning electron microscopy (FESEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Remarkable differences between these two interfaces were suggested both in morphology and chemical compositions. An apatite layer was found between Sr-HA cement and cancellous bone with a thickness of about 70 microm. However, only a very thin interface (about 1 microm) was formed with cortical bone. As for the cancellous bone/cement interface, high ions intensity of Ca, P, Sr, Na, and O were confirmed by FESEM-EDX and ToF-SIMS. Differences in morphology and chemical component between these two interfaces provided convincing evidences for the proposed dissolution-precipitation coupling mechanism in the formation of biological apatite.

Animals↗

Cervical intervertebral disc degeneration induced by unbalanced dynamic and static forces: a novel in vivo rat model.

STUDY DESIGN: Establishment of a novel in vivo animal model of cervical spondylosis. OBJECTIVE: To investigate apoptotic, degenerative, and inflammatory changes occurring in the cervical intervertebral discs of rats. SUMMARY OF BACKGROUND DATA: Cervical degeneration occurs as the result of imbalance of both static and dynamic spinal stabilizers. The disc degeneration that occurs is characterized by increased local inflammation and increased apoptosis of intervertebral disc cells. METHODS: By excising the paraspinal musculature and posterior cervical spinal ligaments of rats, both static and dynamic cervical stabilizers were disrupted. The resultant biomechanical imbalance resulted in biochemical and histologic changes, which were characterized by light microscopy, electron microscopy, immunostaining, enzyme-linked immunosorbent assay, polymerase chain reaction, and in situ hybridization. RESULTS: Histologic analysis showed characteristic degenerative changes of the intervertebral discs and vertebral endplates following surgery. Ultrastructural examination revealed apoptotic changes, which were verified by immunostaining. Instability also resulted in significant up-regulation of inflammatory factors, as shown by enzyme-linked immunosorbent assay, polymerase chain reaction, and in situ hybridization. CONCLUSIONS: By creating static and dynamic posterior instability of the cervical spine, this novel model of cervical spondylosis results in rapid intervertebral disc degeneration characterized by increased apoptosis and local inflammation, such as that seen clinically.

Animals↗

Strontium-containing hydroxyapatite bioactive bone cement in revision hip arthroplasty.

Clinical outcome of cemented implants to revision total hip replacement (THR) is not as satisfactory as primary THR, due to the loss of bone stock and normal trabecular pattern. This study evaluated a bioactive bone cement, strontium-containing hydroxyapatite (Sr-HA) bone cement, in a goat revision hip hemi-arthroplasty model, and compared outcomes with polymethylmethacrylate (PMMA) bone cement. Nine months after operation, significantly higher bonding strength was found in the Sr-HA group (3.36+/-1.84 MPa) than in the PMMA bone cement group (1.23+/-0.73 MPa). After detached from the femoral component, the surface of PMMA bone cement mantle was shown relatively smooth, whereas the surface of the Sr-HA bioactive bone cement mantle was uneven, by SEM observation. EDX analysis detected little calcium and no phosphorus on the surface of PMMA bone cement mantle, while high content of calcium (14.03%) and phosphorus (10.37%) was found on the surface of the Sr-HA bone cement mantle. Even higher content of calcium (17.37%) and phosphorus (10.84%) were detected in the concave area. Intimate contact between Sr-HA bioactive bone cement and bone was demonstrated by histological and SEM observation. New bone bonded to the surface of Sr-HA cement and grew along its surface. However, fibrous tissue was observed between PMMA bone cement and bone. The results showed good bioactivity of Sr-HA bioactive bone cement in this revision hip replacement model using goats. This in vivo study also suggested that Sr-HA bioactive bone cement was superior to PMMA bone cement in terms of bone-bonding strength. Use of bioactive bone cement may be a possible solution overcoming problems associated with the use of PMMA bone cement in revision hip replacement.

Animals↗

Surface characteristics, mechanical properties, and cytocompatibility of oxygen plasma-implanted porous nickel titanium shape memory alloy.

Good surface properties and biocompatibility are crucial to porous NiTi shape memory alloys (SMA) used in medical implants, as possible nickel release from porous NiTi may cause deleterious effects in the human body. In this work, oxygen plasma immersion ion implantation (O-PIII) was used to reduce the amount of nickel leached from porous NiTi alloys with a porosity of 42% prepared by capsule-free hot isostatic pressing. The mechanical properties, surface properties, and biocompatibility were studied by compression tests, X-ray photoelectron spectroscopy (XPS), and cell culturing. The O-PIII porous NiTi SMAs have good mechanical properties and excellent superelasticity, and the amount of nickel leached from the O-PIII porous NiTi is much less than that from the untreated samples. XPS results indicate that a nickel-depleted surface layer predominantly composed of TiO(2) is produced by O-PIII and acts as a barrier against out-diffusion of nickel. The cell culturing tests reveal that both the O-PIII and untreated porous NiTi alloys have good biocompatibility.

Alloys↗

Strontium-containing hydroxyapatite (Sr-HA) bioactive cement for primary hip replacement: an in vivo study.

The purpose of this study was to evaluate the strontium-containing hydroxyapatite (Sr-HA) cement in primary hip replacement, using a rabbit model, and to investigate the histological findings at the cement-implant and bone-cement interfaces under weight-bearing conditions. Unilateral hip replacement was performed with Sr-HA cement or polymethylmethacrylate (PMMA) cement in rabbits and observations were made after 6 months. Good fixation between the Sr-HA cement and implant was observed. Osseointegration of the Sr-HA cement with cancellous bone was widespread. Many multinucleus cells covered the surface of the cement, and resorbed the superficial layer of the cement. By scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX) analysis, high calcium and phosphorus levels were detected at the interface with a thickness of about 10 microm. Intimate contact was also observed between the Sr-HA cement and cortical bone without fibrous layer intervening. The overall affinity index of bone on Sr-HA cement was (85.06 +/- 5.40)%, which is significantly higher than that on PMMA cement (2.77%+/- 0.49%). On the contrary, a fibrous layer was consistently observed between PMMA cement and bone, and PMMA cement evoked an inflammatory response and foreign body reaction in the surrounding bony tissues. Results suggested good bioactivity and bone-bonding ability of the Sr-HA cement under weight-bearing conditions.

Animals↗

Nano-structural bioactive gradient coating fabricated by computer controlled plasma-spraying technology.

The poor mechanical property of hydroxyapatite was the major problem for load bearing and implant coating in clinical applications. To overcome this weakness, a bioactive gradient coating with a special design composition of hydroxyapatite (HA), ZrO2, Ti, bioglass was developed. This 120 microm coating with an upper layer of 30-50 microm porous HA produced by computer controlled plasma spraying which maintained energy level of the plasma which ensure proper melting of powder. The crystal size of the coating was 18.6-26.2 nm. Transformation of t-ZrO2 to m-ZrO2 reduced the thermal stress that weakened the coating and lowered down interfacial strength of the coating and metal substrate. Thermal stress of sprayed coating was 16.4 MPa which was much smaller than the sample without thermal treatment of 67.1 MPa. Interfacial strength between the coating and metal substrate was 53 MPa which is much higher than conventional Hydroxyapatite coating. Based on XRD analysis crystallinity of HA approached 98%. Therefore, high temperature treatment improved long term stability of the coating through improved crystallinity of hydroxyapatite and reduced other impure calcium phosphate phase.

Aluminum Oxide↗

Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys.

Nickel-titanium shape memory alloys are promising materials in orthopedic applications because of their unique properties. However, for prolonged use in a human body, deterioration of the corrosion resistance of the materials becomes a critical issue because of the increasing possibility of deleterious ions released from the substrate to living tissues. We have investigated the use of nitrogen, acetylene, and oxygen plasma immersion ion implantation (PIII) to improve the corrosion resistance and mechanical properties of the materials. Our results reveal that the corrosion resistance and mechanical properties such as hardness and elastic modulus are significantly enhanced after surface treatment. The release of nickel is drastically reduced as compared with the untreated control. In addition, our in vitro tests show that the plasma-treated surfaces are well tolerated by osteoblasts. Among the three types of samples, the best biological effects are observed on the nitrogen PIII samples.

Alloys↗

Nano-mechanics of bone and bioactive bone cement interfaces in a load-bearing model.

Many bioactive bone cements were developed for total hip replacement and found to bond with bone directly. However, the mechanical properties at the bone/bone cement interface under load bearing are not fully understood. In this study, a bioactive bone cement, which consists of strontium-containing hydroxyapatite (Sr-HA) powder and bisphenol-alpha-glycidyl dimethacrylate (Bis-GMA)-based resin, was evaluated in rabbit hip replacement for 6 months, and the mechanical properties of interfaces of cancellous bone/Sr-HA cement and cortical bone/Sr-HA cement were investigated by nanoindentation. The results showed that Young's modulus (17.6+/-4.2 GPa) and hardness (987.6+/-329.2 MPa) at interface between cancellous bone and Sr-HA cement were significantly higher than those at the cancellous bone (12.7+/-1.7 GPa; 632.7+/-108.4 MPa) and Sr-HA cement (5.2+/-0.5 GPa; 265.5+/-39.2 MPa); whereas Young's modulus (6.3+/-2.8 GPa) and hardness (417.4+/-164.5 MPa) at interface between cortical bone and Sr-HA cement were significantly lower than those at cortical bone (12.9+/-2.2 GPa; 887.9+/-162.0 MPa), but significantly higher than Sr-HA cement (3.6+/-0.3 GPa; 239.1+/-30.4 MPa). The results of the mechanical properties of the interfaces were supported by the histological observation and chemical composition. Osseointegration of Sr-HA cement with cancellous bone was observed. An apatite layer with high content of calcium and phosphorus was found between cancellous bone and Sr-HA cement. However, no such apatite layer was observed at the interface between cortical bone and Sr-HA cement. And the contents of calcium and phosphorus of the interface were lower than those of cortical bone. The mechanical properties indicated that these two interfaces were diffused interfaces, and cancellous bone or cortical bone was grown into Sr-HA cement 6 months after the implantation.

Animals↗

Investigation of nickel suppression and cytocompatibility of surface-treated nickel-titanium shape memory alloys by using plasma immersion ion implantation.

Nickel-titanium (NiTi) shape memory alloys are increasingly being used in orthopedic applications. However, there is a concern that Ni is harmful to the human body. We have recently investigated the use of nitrogen, or oxygen plasma immersion ion implantation to mitigate this deleterious effect. Our results reveal that the near-surface Ni concentration in all the treated samples is significantly suppressed. In addition, our in vitro tests show that the plasma-treated surfaces are cytologically compatible allowing the attachment and proliferation of osteoblasts. Among the two types of samples, the best biological effects are found on the samples with nitrogen implantation.

Animals↗

Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys.

Nickel-titanium (NiTi) shape memory alloys possess super-elasticity in addition to the well-known shape memory effect and are potentially suitable for orthopedic implants. However, a critical concern is the release of harmful Ni ions from the implants into the living tissues. We propose to enhance the corrosion resistance and other surface and biological properties of NiTi using carbon plasma immersion ion implantation and deposition (PIII&D). Our corrosion and simulated body fluid tests indicate that either an ion-mixed amorphous carbon coating fabricated by PIII&D or direct carbon PIII can drastically improve the corrosion resistance and block the out-diffusion of Ni from the materials. Our tribological tests show that the treated surfaces are mechanically more superior and cytotoxicity tests reveal that both sets of plasma-treated samples favor adhesion and proliferation of osteoblasts.

Animals↗

Adaptive signal enhancement of somatosensory evoked potential for spinal cord compression detection: an experimental study.

The objective of this study was to assess the efficacy of adaptive signal enhancement (ASE) as a means of indicating intraoperative spinal cord impingement. ASE technique was used to determine the changes in the somatosensory evoked potential (SEP) elicited from eighteen rats with varying levels of spinal cord compression. ASE technique was found to be able to effectively extract SEP signals for the detection of spinal cord injury. Furthermore, while the traditional ensemble averaging (EA) technique requires more than 500 trials for meaningful signal processing in severe noisy SEP recordings, the ASE method required only 50 trials to provide similar information. Because of its fast and reliable SEP detection, the ASE method is ideal for spinal cord monitoring in the clinical setting.

Algorithms↗

Cemented or uncemented femoral component in primary total hip replacement? A review from a clinical and radiological perspective.

Controversy exists regarding the optimal method of fixation for primary total hip replacement, particularly the femoral component. We performed a systematic literature review to explore whether cemented total hip replacement can achieve better clinical and radiological outcomes. A total of 29 publications were selected using computer-aided and manual searches. A qualitative comparison of results in clinical and radiological changes was then conducted. Most of the literature showed that better short-term clinical and functional outcomes could be obtained from cemented femoral fixation than from uncemented femoral fixation. Results were less clear for the mid-term clinical outcome, though in general, cemented fixation still appeared to show a superior clinical outcome. Radiographic differences are variable and do not seem to correlate with clinical findings. For the short- and mid-term, cemented femoral component is recommended. However, a long-term randomised trial combined with a large cohort study or registry is needed.

Arthroplasty, Replacement, Hip↗

Biomechanical and electromyographic evaluation of ankle foot orthosis and dynamic ankle foot orthosis in spastic cerebral palsy.

This study evaluated the biomechanical and electromyographic effects of conventional ankle foot orthoses (AFOs) and dynamic ankle foot orthoses (DAFOs) on gait in patients with spastic cerebral palsy (CP). Thirteen patients with dynamic equinus underwent motion analysis with electromyography. Both AFOs and DAFOs provided longer stride length, permitted pre-positioning for initial contact, and successfully controlled the excessive plantarflexion during the swing phase. Median frequency (MF) of EMG signal indicated that extremely high firing was found in the patient's lower limbs compared to controls that resulted in tiredness. The DAFOs allowed a significantly larger total ankle range of motion than the AFOs. However, AFOs significantly reduced the MF while DAFOs did not. The reduced MF seen when wearing AFOs suggested an improvement of walking endurance. The DAFO had the advantage of less restriction on ankle movement, which avoids muscular atrophy and improves orthotic compliance.

Ankle Joint↗