Cleaning products and air fresheners: emissions and resulting concentrations of glycol ethers and terpenoids.

UNLABELLED: Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m3 room ventilated at approximately 0.5/h. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 microg/m3 for individual terpenoids, including alpha-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and alpha-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or d-limonene were 300-6000 microg/m3 after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractional emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, and approximately 25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were approximately 35-70% with towels retained, and 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and beta-citronellol) were emitted at 35-180 mg/day over 3 days while air concentrations averaged 30-160 microg/m3. PRACTICAL IMPLICATIONS: While effective cleaning can improve the healthfulness of indoor environments, this work shows that use of some consumer cleaning agents can yield high levels of volatile organic compounds, including glycol ethers--which are regulated toxic air contaminants--and terpenes that can react with ozone to form a variety of secondary pollutants including formaldehyde and ultrafine particles. Persons involved in cleaning, especially those who clean occupationally or often, might encounter excessive exposures to these pollutants owing to cleaning product emissions. Mitigation options include screening of product ingredients and increased ventilation during and after cleaning. Certain practices, such as the use of some products in dilute solution vs. full-strength and the prompt removal of cleaning supplies from occupied spaces, can reduce emissions and exposures to 2-butoxyethanol and other volatile constituents. Also, it may be prudent to limit use of products containing ozone-reactive constituents when indoor ozone concentrations are elevated either because of high ambient ozone levels or because of the indoor use of ozone-generating equipment.

Air Pollutants↗

Indoor particle dynamics.

UNLABELLED: Airborne particulate matter is a diverse pollutant class whose excessive presence in indoor air contributes to an array of adverse health and material-damage effects. Particles are classified according to their diameter into three size modes: ultrafine (0.1 microm), accumulation (0.1-2 microm), and coarse (= 2 microm). These modes have largely distinct sources and composition, and they exhibit different dynamic behaviors. The concept of mass conservation or material balance provides a foundation for quantitatively and mechanistically linking important outcome variables, such as concentrations and exposures, to the influencing input parameters. The factors governing indoor particle concentrations include direct emissions from indoor sources, ventilation supply from outdoor air, filtration, deposition onto indoor surfaces, and removal from indoor air by means of ventilation. In some circumstances, transport and transformation processes within indoor environments may also play an important role in influencing particle concentrations and consequences. Such processes include mixing, interzonal transport, resuspension, coagulation, and phase change. PRACTICAL IMPLICATIONS: The paper gives a practical overview of issues related to particulate matter indoors, as well as valuable information for understanding filtration and how particles contribute to adverse health effects.

Air Movements↗

Dynamic behavior of semivolatile organic compounds in indoor air. 2. Nicotine and phenanthrene with carpet and wallboard.

The surface interactions of nicotine and phenanthrene with carpet, painted wallboard, and stainless steel were investigated in a room-sized environmental test chamber. Adsorption kinetics were tested by flash evaporating a known mass of each compound into a sealed 20 m3 chamber containing one or more of the tested sorbents. In each experiment, one or more emissions were performed after the gas-phase concentration had reached an apparent plateau. At the end of each experiment, the chamber was ventilated and resealed to monitor reemission of the compound from the sorbents. Kinetic sorption parameters were determined by fitting a mass-balance model to the experimental results. The sorption capacity of stainless steel was of similar magnitude for nicotine and phenanthrene. Sorption of nicotine on carpet and wallboard was much stronger, with equilibrium partitioning values 2-3 orders of magnitude higher. The sorption capacities of phenanthrene on carpet and wallboard were smaller, approximately 10-20% of the stainless steel values. The rates of uptake are of similar magnitude for all sorbate--sorbent pairs and are consistent with the limit imposed by gas-phase boundary-layer mass transport. The rates of desorption are much faster for phenanthrene than for nicotine. Model simulations predict average nicotine levels in a typical smoking residence that are consistent with published data.

Adsorption↗

Inhalation transfer factors for air pollution health risk assessment.

To facilitate routine health risk assessments, we develop the concept of an inhalation transfer factor (ITF). The ITF is defined as the pollutant mass inhaled by an exposed individual per unit pollutant mass emitted from an air pollution source. A cumulative population inhalation transfer factor (PITF) is also defined to describe the total fraction of an emitted pollutant inhaled by all members of the exposed population. In this paper, ITFs and PITFs are calculated for outdoor releases from area, point, and line sources, indoor releases in single zone and multizone indoor environments, and releases within motor vehicles. Typical PITFs for an urban area from emissions outdoors are approximately 10(-6)-10(-3). PITFs associated with emissions in buildings or in moving vehicles are typically much higher, approximately 10(-3)-10(-1).

Air Pollutants↗

Radon entry into houses: the importance of scale-dependent permeability.

Soil permeability to air can increase substantially with measurement length scale. We tested the hypothesis that the scale effect could resolve large model underpredictions of radon and soil-gas entry into two experimental basement structures located in natural sandy-loam soil at a field site in Ben Lomond, CA. Previously, the model input for permeability at the site had been assessed based on 0.5-m scale measurements. After determining the soil-structure interaction scale (system scale) to be approximately 3 m, the model input was changed to reflect 3-m scale permeability measurements. This adjustment reduced unacceptably large model underpredictions, of a factor of 3 to 5, to a range near that of acceptable experimental error, 20 to 40%. The permeability scale effect may explain large and persistent model underestimates of radon entry into real houses. The results argue strongly for determining permeability at a length scale consistent with that of the system under study.

Air Pollution, Indoor↗

Indoor air quality impacts of ventilation ducts: ozone removal and emissions of volatile organic compounds.

The concentrations of contaminants in the supply air of mechanically ventilated buildings may be altered by pollutant emissions from and interactions with duct materials. We measured the emission rate of volatile organic compounds (VOCs) and aldehydes from materials typically found in ventilation ducts. The emission rate of VOCs per exposed surface area of materials was found to be low for some duct liners, but high for duct sealing caulk and a neoprene gasket. For a typical duct, the contribution to VOC concentrations is predicted to be only a few percent of common indoor levels. We exposed selected materials to approximately 100-ppb ozone and measured VOC emissions. Exposure to ozone increased the emission rates of aldehydes from a duct liner, duct sealing caulk, and neoprene gasket. The emission of aldehydes from these materials could increase indoor air concentrations by amounts that are as much as 20% of odor thresholds. We also measured the rate of ozone uptake on duct liners and galvanized sheet metal to predict how much ozone might be removed by a typical duct in ventilation systems. For exposure to a constant ozone mol fraction of 37 ppb, a lined duct would initially remove approximately 9% of the ozone, but over a period of 10 days of ozone removal efficiency would diminish to less than 4%. In an unlined duct, in which only galvanized sheet metal is exposed to the air-stream, the removal efficiency would be much lower, approximately 0.02%. Therefore, ducts in ventilation systems are unlikely to be a major sink for ozone.

Air Pollution, Indoor↗

Reducing the risk of accidental death due to vehicle-related carbon monoxide poisoning.

Emissions of carbon monoxide (CO) from motor vehicles cause several hundred accidental fatal poisonings annually in the United States. The circumstances that could lead to fatal poisonings in residential settings with motor vehicles as the source of CO were explored. The risk of death in a garage (volume = 90 m3) and a single-family dwelling (400 m3) was evaluated using a Monte Carlo simulation with varying CO emission rates and ventilation rates. Information on emission rates was obtained from a survey of motor vehicle exhaust gas composition under warm idle conditions in California, and information on ventilation rates was obtained from a summary of published measurements in the U.S. housing stock. The risk of death ranged from 16 to 21% for a 3-hr exposure in a garage to 0% for a 1-hr exposure in a house. Older vehicles were associated with a disproportionately high risk of death. Removing all pre-1975 vehicles from the fleet would reduce the risk of death by one-fourth to two-thirds, depending on the exposure scenario. Significant efforts have been made to control CO emissions from motor vehicles with the goal of reducing CO concentrations in outdoor air. Substantial public health benefit could also be obtained if vehicle control measures were designed to take account of acute CO poisonings explicitly.

Accidents, Traffic↗

Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control.

Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.

Filtration↗

Effectiveness of smokeless ashtrays.

Most environmental tobacco smoke (ETS) issues from the tips of smoldering cigarettes between puffs. Smokeless ashtrays are designed to reduce ETS exposure by removing particulate and/or gas-phase contaminants from this plume. This paper describes an experimental investigation of the effectiveness of four smokeless ashtrays: two commercial devices and two prototypes constructed by the authors. In the basic experimental protocol, one or more cigarettes was permitted to smolder in a room. Particulate or gas-phase pollutant concentrations were measured in the room air over time. Device effectiveness was determined by comparing pollutant concentrations with the device in use to those obtained with no control device. A lung deposition model was applied to further interpret device effectiveness for particle removal. The commercial ashtrays were found to be substantially ineffective in removing ETS particles because of the use of low-quality filter media and/or the failure to draw the smoke through the filter. A prototype ashtray using HEPA filter material achieved better than 90% particle removal efficiency. Gas-phase pollutant removal was tested for only one prototype smokeless ashtray, which employed filters containing activated carbon and activated alumina. Removal efficiencies for the 18 gas-phase compounds measured (above the detection limit) were in the range of 70 to 95%.

Adult↗

Imaging indoor tracer-gas concentrations with computed tomography: experimental results with a remote sensing FTIR system.

This work demonstrates for the first time the feasibility of computed tomography (CT) reconstructions of pollutant concentrations in a real room setting. A remote sensing Fourier transform infrared spectrometer was mounted on a moving base in a controlled ventilation chamber. A passive tracer was released from a point source into the room under constant ventilation conditions. A series of experiments gathered multiple path-averaged measurements in a two-dimensional plane for CT reconstruction. Simultaneous readings were gathered with a multiple-point sampling array for later comparison to the CT reconstructed concentrations. Good qualitative agreement between the reconstruction and point sample data was obtained. Limitations encountered due to the temporal resolution, size, and geometry of the experimental apparatus are clearly surmountable with better instrumentation.

Air Pollutants, Occupational↗

Potable water as a source of airborne 222Rn in U.S. dwellings: a review and assessment.

Using a long-term-average, single-cell model and available data for U.S. housing, the concentration of 222Rn in indoor air due to the use of potable water is assessed. The ratio of the airborne 222Rn concentration to the concentration in water is represented by a lognormal distribution with geometric mean and geometric standard deviation of 0.65 X 10(-4) and 2.88, respectively, in fair agreement with the previously reported results of direct measurements of the ratio in 13 houses. By combining this result with data on 222Rn concentrations in U.S. water supplies, potable water is estimated to contribute an average of 24, 1.3, and 0.1 Bq m-3 to the airborne 222Rn concentration in residences served by private wells, public ground water, and surface water supplies, respectively.

Air Pollutants↗

Distribution of airborne radon-222 concentrations in U.S. homes.

Apparently large exposures of the general public to the radioactive decay products of radon-222 present in indoor air have led to systematical appraisal of monitoring data from U.S. single-family homes; several ways of aggregating data were used that take into account differences in sample selection and season of measurements. The resulting distribution of annual-average radon-222 concentrations can be characterized by an arithmetic mean of 1.5 picocurie per liter (55 becquerels per cubic meter) and a long tail with 1 to 3% of homes exceeding 8 picocuries per liter, or by a geometric mean of 0.9 picocurie per liter and a geometric standard deviation of about 2.8. The standard deviation in the means is 15%, estimated from the number and variability of the available data sets, but the total uncertainty is larger because these data may not be representative. Available dose-response data suggest that an average of 1.5 picocuries per liter contributes about 0.3% lifetime risk of lung cancer and that, in the million homes with the highest concentrations, where annual exposures approximate or exceed those received by underground uranium miners, long-term occupants suffer an added lifetime risk of at least 2%, reaching extraordinary values at the highest concentrations observed.

Air Pollutants↗

Characterizing the sources, range, and environmental influences of radon 222 and its decay products.

Recent results from our group directly assist efforts to identify and control excessive concentrations of radon 222 and its decay products in residential environments. We have demonstrated directly the importance of pressure-induced flow of soil gas for transport of radon from the ground into houses. Analysis of available information from measurements of concentrations in U.S. homes has resulted in a quantitative appreciation of the distribution of indoor levels, including the degree of dependence on geographic location. Experiments on the effectiveness of air cleaning devices for removal of particles and radon decay products indicate the potential and limitations of this approach to control.

Construction Materials↗

Radon entry into houses having a crawl space.

The transport of 222Rn from soil, through a vented crawl space, and into the living space of single-family residences was studied. Two houses were monitored in detail for periods of 5 and 7 weeks. With crawl space vents open, the average indoor 222Rn concentrations were 1.2 and 0.6 pCi 1.-1 (44 and 22 Bq m-3); with the vents sealed the averages rose to 2.2 and 1.0 pCi 1.-1 (81 and 37 Bq m-3). The data suggest that, of the Rn released into the crawl space from the soil beneath the house, a significant fraction, perhaps 50% or more, enters the living space. The effect of 3 meteorological parameters--wind speed, indoor-outdoor temperature difference, and rate of barometric pressure change--on Rn concentration and entry rate were examined. In 1 of the houses a higher temperature difference corresponded to a higher indoor concentration, suggesting that the increased infiltration rate is more than compensated by an increase in the Rn entry rate. On the other hand, a high wind speed tended to reduce the indoor concentration, presumably by increasing both cross-ventilation of the crawl space and the infiltration rate of the living space. Results suggest that Rn transport into the crawl space of at least 1 of the houses occurred by pressure-driven flow, rather than solely by molecular diffusion. The diffusion coefficient of 222Rn through polyethylene sheeting, such as was present on the ground beneath this house, was measured in the laboratory and found to range from 0.65 X 10(-7) cm2 s-1 at 11 degrees C to 1.6 X 10(-7) cm2 s-1 at 25 degrees C, implying that the maximum diffusive flux through the sheet was many times smaller than that necessary to account for the rate of Rn entry into the house. A third house was studied using a tracer gas injected into the crawl space at a controlled rate. The fraction of air leaving the crawl space that entered the living space ranged from 0.3 to 0.65, in good agreement with results for Rn transmission in the other 2 houses, assuming that the 222Rn flux into the crawl space was comparable to that which would have resulted from molecular diffusion from soil having a 222Rn diffusion length of 1.0 m. By sealing leaks in the floor of this house, the average infiltration rate was reduced by 25%, but the indoor concentration of the tracer gas remained constant.

Air Pollutants↗

Optimizing the total-alpha three-count technique for measuring concentrations of radon progeny in residences.

A technique for measuring 222Rn-progeny concentrations in air, involving counting alpha decays for three intervals on a filter through which air has been drawn, is optimized for measuring low concentrations typically found indoors. Sampling and counting intervals are selected to minimize a linear combination of the minimum measurable concentrations (MMCs)--concentrations at which the relative standard deviation in the measurement due to counting statistics is 20%. The effects on the MMCs of varying total measurement time, sampling and delay times, and of radon-progeny activity ratios are considered. The effect on measurement precision of variations in the collection rate of radon progeny on the filter is also evaluated. Previous work on this technique has often focused on measurements in uranium mines where concentrations of radon progeny are typically much higher than in residences. With sequential sampling and counting intervals, extending the total measurement time from 35 to 60 min reduces the MMCs by factors of 3, 7 and 4 for 218Po, 214Pb and 214Bi, respectively, thereby permitting precise measurement of indoor concentrations down to the order of one pCi/1. By employing an instrument that counts while sampling, the MMCs can be further reduced by factors of 5.5 for 218Po, 2 for 214Pb and 2.5 for 214Bi, again for a 60-min measurement period.

Air Pollutants↗

Time-averaged indoor Rn concentrations and infiltration rates sampled in four U.S. cities.

Indoor Rn concentrations, measured in 58 houses during a 4- to 5-mon period during the winter and spring of 1981-1982, varied from 0.1-16 pCi l-1 (4-590 Bq m-3). Average infiltration rates were determined for each house during the same period, based on a measurement of the effective leakage area and an infiltration model, and found to range from 0.2-2.2 air changes per hour (h-1). Indoor Rn concentrations correlated poorly with infiltration rates for houses within each city as well as for the entire sample. Differences in Rn entry rates among houses thus appear to be more important than differences in infiltration rates in determining whether a house has high indoor Rn levels, consistent with previous indications from grab-sample measurements. Radon entry rates and indoor Rn concentrations were generally higher in houses in Fargo, ND, and Colorado Springs, CO, than in houses in Portland, ME, and Charleston, NC.

Air Pollutants↗

Radon concentrations and infiltration rates measured in conventional and energy-efficient houses.

To elucidate any connection between high radon concentrations and low-infiltration houses, we have concurrently measured the 222Rn concentration and the infiltration rate in U.S. houses. Three housing surveys have been undertaken: one in "energy-efficient" houses located throughout the U.S. and two in "conventional" houses in the San Francisco area and in Maryland. In each of the groups surveyed, no clear correlation was observed between 222Rn concentrations and infiltration rate, although each parameter varied over a wide range. Infiltration rates for the entire sample, numbering 98 houses, ranged between 0.02 and 1.6 air changes per hr, and 222Rn concentrations ranged from 0.1 to 27 pCi/l. It appears that the major cause of the observed differences in 222Rn concentration is variation from one house to another in the rate at which 222Rn enters houses from its sources.

Air↗