A bacteriologically occlusive clothing system for use in the operating room.

A comparison was made in a laminar-flow operating room between total-body exhaust gowns and a clothing system made from Fabric 450. This disposable clothing was found to be much more comfortable and convenient than the total-body exhaust gowns. The average airborne bacterial counts obtained during total hip replacement operations from each of the clothing systems were identical when the downflow method of ventilation was used (0.7 per cubic metre) and no significant difference could be demonstrated when the crossflow system was used (2.2 per cubic metre with the total-body exhaust gowns and 3.1 per cubic metre with the disposable clothing). Tests in a dispersal chamber were carried out to find the effectiveness of each item of the disposable clothing in reducing bacterial dispersion. These tests demonstrated the relative ineffectiveness of wearing a surgical gown as compared with wearing the complete system. It was confirmed bacteriologically that the downflow system of ventilation was more efficient than the crossflow type; the importance of this observation with respect to clothing and sepsis is discussed in this paper.

Air Microbiology↗

Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study.

In a multicentre study of sepsis after total hip or knee replacement the operations performed by each surgeon were allocated at random between control and ultraclean-air operating rooms. Records were obtained from over 8000 such operations. In the patients whose prostheses were inserted in an operating room ventilated by an ultraclean-air system the incidence of joint sepsis confirmed at reoperation within the next one to four years was about half that of patients who had had the operation in a conventionally ventilated room at the same hospital. When whole-body exhaust-ventilated suits had been worn by the operating team in a theatre ventilated by an ultraclean-air system the incidence of sepsis was about a quarter of that found after operations performed with conventional ventilation. When all groups in the trial were considered together the analysis showed deep sepsis after 63 out of 4133 operations in the control group (1.5%) and after 23 out of 3922 operations in the ultraclean-air groups (0.6%) (ratio 2.6, 95% confidence limits 1.6-4.2; p less than 0.001). The design of the study did not include a strictly controlled test of the effect of prophylactic antibiotics, but their use was associated with a lower incidence of sepsis than in patients who had received no antibiotic prophylaxis at their operations (0.6% (34/5831) v 2.3% (52/2221); ratio 4.0).

Air Microbiology↗

Bacterial dispersion in relation to operating room clothing.

The effect of operating clothing on the dispersal of bacterial particles from the wearers was studied in a dispersal chamber. A comparison was made of six gowns as well as four types of trousers. The gowns were of three basic types, namely a conventional cotton type, disposable types made of non-woven fabric and those of the total-body exhaust system (Charnley type). The dispersal chamber could simulate conditions as expected both in down-flow unidirectional ultra-clean systems and in a conventional turbulent plenum-ventilated system. It was found that the disposable gowns would reduce the dispersal rate by about 30% in the simulated conventionally ventilated system and about 65% in the laminar flow system. The total-body exhaust system (Charnley) would reduce the count by 10-fold in the conventional ventilated system and by 66-fold in the laminar-flow system. The poor performance of the gowns in conventionally ventilated systems was caused by the dispersal of bacterial particles from underneath the gown (about 80%). This was not reduced by the disposable gown and only partially by the Charnley type. This small drop would be further decreased in a conventionally ventilated operating-room as only scrubbed staff would wear the gown. In order to overcome this poor performance in conventionally ventilated operating-rooms impervious trousers would be required. Four types were studied and it was demonstrated that those made either from Ventile or non-woven fabric would reduce the bacterial dispersion fourfold. As these tests had been carried out in an artificial environment checks were carried out in the unidirectional-flow operating-room during total-hip arthroplasty. This was done by comparing conventional cotton gowns with non-woven gowns and total-body exhaust gowns. The results showed good correlation between the operating room and the chamber with the non-woven fabric gown but the total-body exhaust system did not perform as well in the operating room (12-fold compared to 66-fold) the difference being possibly due to the contribution from the patient. However, as this comparison was that which would be most open to influence from other variables confidence could be placed on the chamber test results. Values were also obtained for the total number of bacterial particles dispersed by persons during a standard exercise wearing different clothing. This count was dependent on the clothing worn but a median count of between 1000 and 1500 bacterial particles/min. would be expected when conventional clothing was worn, with a range of between 300 and 19,000. This count could be reduced to about 100/min. if a total-body exhaust suit was worn (range 30-400).

Air Microbiology↗

Coagulase-negative staphylococci and micrococci in urinary tract infections.

One hundred catalase-positive, coagulase-negative, Gram-positive cocci isolated in significant numbers from the urine of patients with urinary tract infections, provisionally subdivided by their sensitivity to nonoviocin, were classified according to a slightly model version of Baird-Parker's schemes (1965 and 1972). It appeared that strains of Micrococcus were nearly all of sub-group 3, and that these were important pathogens of young women presenting with urinary infections in general practice. All such strains were resistant to novobiocin. Strains of staphylococcus were heterogeneous, and were found principally in infections arising in hospital, among older prople. Most staphylococci were sensitive to novobiocin. It is suggested that it is easy and sufficiently accurate to separate staphylococci and micrococci isolated from cases of urinary tract infection on the basis of their sensitivity or resistance to novo-biocin. The distinction is useful because of its therapeutic and epidemiological significance.

Adolescent↗

The effect of obstructions and thermals in laminar-flow systems.

The influence of obstructions and thermals on the air flow in unidirectional or laminar flow systems was studied with special reference to operating rooms. It was shown that thermals induced in the operating rooms would have little influence in the normal laminar-flow system. The importance however of obstructions such as operating lamps and personnel was shown.

Air Conditioning↗

An evaluation of a partial-walled laminar-flow operating room.

This paper contains an assessment of the physical performance of a permanently installed down-flow laminar-flow operating room at the London Hospital. This system employs partial walls extending 0.76 m (2.5 ft.) from the ceiling, from which the air is allowed to issue freely downwards at an initial velocity of about 0.4 m./sec. (80 ft./min.).The usefulness of the partial wall, as compared with a free issuing system, was demonstrated and a comparison made with a fully walled system. It was shown that a fully walled system would be more efficient than a partial-walled system as there was a loss in air velocity of about 20-25% with the partial wall due to the nonconstrained flow of air. This loss would be reflected in an increase in airborne bacterial count and would mean that an increase of 20-25% in the air volume would be required to obtain the same conditions as with the full-walled system. Entrainment of contaminated air was demonstrated but it was concluded that this would be of little consequence in the centre of the clean area, i.e. at the wound site. Sterile instruments, etc., however, on the outside of the clean area, would be more liable to airborne contamination.Bacterial and dust airborne counts taken during total hip operations gave a very low average figure (0.3 bacteria/ft.(3) or 10.5/m.(3)) from which we conclude that the system was about 30 times cleaner in terms of airborne bacteria than a well ventilated conventional operating-room. We concluded that although the partial-walled system was slightly less efficacious than a normal full-walled system, the freedom of movement and of communication for the operating team could in some circumstances outweigh this disadvantage.Sound levels were such that normal conversation was possible with little or no awareness of background noise.

Air↗

A bacteriological evaluation of laminar-flow systems for orthopaedic surgery.

An evaluation has been undertaken of the efficiency of laminar-flow ventilation in operating-rooms in which conventional operating-room clothing was used. It has been demonstrated that velocities in the region of 0.3-0.4 m./sec. will give maximum returns for effort in both down-flow and cross-flow systems. At this velocity the laminar-flow system, in terms of airborne bacteria measured at the wound site, was about 11 times more efficient using horizontal air-flow and 35-90 times more efficient using vertical air-flow than a plenum-ventilated operating-room.

Air Conditioning↗