PubMed Health⌕ Search

Biomedical subjects

W Wijns

Publications and source records attributed to W Wijns.

At least 19 recordsLinked to original sources

Diagnostic and prognostic value of non-invasive imaging in known or suspected coronary artery disease.

The role of non-invasive imaging techniques in the evaluation of patients with suspected or known coronary artery disease (CAD) has increased exponentially over the past decade. The traditionally available imaging modalities, including nuclear imaging, stress echocardiography and magnetic resonance imaging (MRI), have relied on detection of CAD by visualisation of its functional consequences (i.e. ischaemia). However, extensive research is being invested in the development of non-invasive anatomical imaging using computed tomography or MRI to allow detection of (significant) atherosclerosis, eventually at a preclinical stage. In addition to establishing the presence of or excluding CAD, identification of patients at high risk for cardiac events is of paramount importance to determine post-test management, and the majority of non-invasive imaging tests can also be used for this purpose. The aim of this review is to provide an overview of the available non-invasive imaging modalities and their merits for the diagnostic and prognostic work-up in patients with suspected or known CAD.

Coronary Artery Disease↗

Management and outcome of patients with established coronary artery disease: the Euro Heart Survey on coronary revascularization.

AIMS: The purpose of the Euro Heart Survey Programme of the European Society of Cardiology is to evaluate to which extent clinical practice endorses existing guidelines as well as to identify differences in population profiles, patient management, and outcome across Europe. The current survey focuses on the invasive diagnosis and treatment of patients with established coronary artery disease (CAD). METHODS AND RESULTS: Between November 2001 and March 2002, 7769 consecutive patients undergoing invasive evaluation at 130 hospitals (31 countries) were screened for the presence of one or more coronary stenosis >50% in diameter. Patient demographics and comorbidity, clinical presentation, invasive parameters, treatment options, and procedural techniques were prospectively entered in an electronic database (550 variables+29 per diseased coronary segment). Major adverse cardiac events (MACE) were evaluated at 30 days and 1 year. Out of 5619 patients with angiographically proven coronary stenosis (72% of screened population), 53% presented with stable angina while ST elevation myocardial infarction (STEMI) was the indication for coronary angiography in 16% and non-ST segment elevation myocardial infarction or unstable angina in 30%. Only medical therapy was continued in 21%, whereas mechanical revascularization was performed in the remainder [percutaneous coronary intervention (PCI) in 58% and coronary artery bypass grafting (CABG) in 21%]. Patients referred for PCI were younger, were more active, had a lower risk profile, and had less comorbid conditions. CABG was performed mostly in patients with left main lesions (21%), two- (25%), or three-vessel disease (67%) with 4.1 diseased segments, on average. Single-vessel PCI was performed in 82% of patients with either single- (45%), two- (33%), or three-vessel disease (21%). Stents were used in 75% of attempted lesions, with a large variation between sites. Direct PCI for STEMI was performed in 410 cases, representing 7% of the entire workload in the participating catheterization laboratories. Time delay was within 90 min in 76% of direct PCI cases. In keeping with the recommendations of practice guidelines, the survey identified under-use of adjunctive medication (GP IIb/IIIa receptor blockers, statins, and angiotensin-converting enzyme-inhibitors). Mortality rates at 30 days and 1 year were low in all subgroups. MACE primarily consisted of repeat PCI (12%). CONCLUSION: The current Euro Heart Survey on coronary revascularization was performed in the era of bare metal stenting and provides a global European picture of the invasive approach to patients with CAD. These data will serve as a benchmark for the future evaluation of the impact of drug-eluting stents on the practice of interventional cardiology and bypass surgery.

Angina, Unstable↗

Clinical and angiographic outcome of patients with mild coronary lesions treated with balloon angioplasty or coronary stenting. Implications for mechanical plaque sealing.

AIMS: To investigate the clinical and angiographic outcome of patients with mild coronary lesions treated with balloon angioplasty or coronary stenting (coronary plaque sealing, i.e. dilatation of angiographically non-significant lesions) compared to moderate and severe stenoses. METHODS AND RESULTS: Patients with chronic stable angina and a single de novo lesion in a native coronary vessel scheduled to undergo percutaneous coronary intervention (PCI) were selected from 14 different studies. Off-line analysis of angiographic outcomes was assessed in all patients using identical and standardised methods of data acquisition, analysis and definitions. Clinical endpoints were adjudicated by independent clinical events committees. All quantitative coronary angiographic (QCA) analyses were performed in the same core laboratory. Stenosis severity prior to PCI was categorised into three groups: <50% diameter stenosis (DS), 50-99%DS and >99%DS pre. A total of 3812 patients were included in this study; 1484 patients (39%) were successfully treated with balloon angioplasty (BA) only and stented angioplasty was performed in 2328 patients (61%).One-year mortality and rate of non-fatal myocardial infarction (MI) (Kaplan-Meier) did not differ between BA and stented angioplasty for any of the stenosis severity categories. Following BA, the combined event rate (death and non-fatal MI) was 4.8, 4.6 and 0% in the <50, 50-99 and >99%DS categories, respectively. Following stented angioplasty, the combined event rate was 3.1, 4.4 and 4.8% in the same categories. The need for repeat revascularisation corrected for stenosis severity in the Cox proportional-hazards regression model was reduced by 20% after stented angioplasty (hazard ratio (HR) 0.80, 95%CI 0.69-0.93). CONCLUSION: The concept of plaque sealing is appealing from the theoretical point of view. However, with current technology, plaque sealing cannot prevent death and future non-fatal MIs in the long-term because 1-year event rates after PCI of non-significant stenoses remain unacceptably elevated when compared with the estimated 1-year probability of a non-fatal MI in lesions with a <50%DS. Moreover, major adverse cardiac events at 1-year after PCI are not directly related to the degree of pre-procedural stenosis severity.

Angina Pectoris↗

Clinical and angiographic acute and follow up results of intracoronary beta brachytherapy in saphenous vein bypass grafts: a subgroup analysis of the multicentre European registry of intraluminal coronary beta brachytherapy (RENO).

OBJECTIVE: To assess clinically and angiographically the feasibility, safety, and effectiveness of vascular brachytherapy (VBT) in saphenous vein bypass grafts (SVG). PATIENTS AND METHODS: 67 of 1098 (6.1%) consecutive patients of the European registry of intraluminal coronary beta brachytherapy underwent treatment for 68 SVG lesions by VBT using a Sr/Y(90) source train (BetaCath). Clinical follow up data were obtained for all of them after a mean (SD) of 6.3 (2.4) months and angiographic follow up was performed in 61 patients (91.0%) after 6.9 (2.0) months. RESULTS: 58 (86.6%) patients were men, their mean (SD) age was 66 (10) years, 28 (41.8%) had unstable angina, and 21 (31.3%) had diabetes. Fifty three (77.9%) lesions were in-stent restenosis, 13 (19.1%) de novo lesions, and 2 (3.0%) non-stented restenotic lesions. Mean (SD) reference diameter before the intervention was 4.19 (0.52) mm, mean (SD) lesion length was 23.56 (20.38) mm, and mean (SD) minimum lumen diameter measured 0.73 (0.62) mm. Mean (SD) acute gain was 3.02 (0.88) mm. The prescribed radiation dose was 20.1 (3.2) Gy. Pullback manoeuvres were performed in 17 (25.0%) of cases. Most patients received combined aspirin and thienopyridin treatment for 6 or 12 months after the procedure. Technical success was obtained in 62 (91.2%) treated lesions and in-hospital major adverse cardiac events occurred in 4.5%. At follow up, mean (SD) reference diameter was 4.20 (0.53) mm, minimum lumen diameter 2.94 (1.50) mm, and late loss 0.86 (1.25) mm. The overall major adverse cardiac events rate was 26.7%. CONCLUSION: VBT of SVG is feasible and safe. At follow up the reintervention rate and cardiac morbidity and mortality seem to be favourable, considering that interventions in SVG usually are associated with the highest risks.

Aged↗

Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size.

BACKGROUND: Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, approximately 40% of the vessels were small (<2.5 mm). The present study evaluates the relationship between angiographic outcome and vessel diameter for sirolimus-eluting stents. METHODS AND RESULTS: Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into tertiles according to their reference diameter (RD; stratum I, RD <2.36 mm; stratum II, RD 2.36 mm to 2.84 mm; stratum III, RD >2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01+/-0.25 versus 0.80+/-0.43 mm in stratum I, 0.01+/-0.38 versus 0.88+/-0.57 mm in stratum II, and -0.06+/-0.35 versus 0.74+/-0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Delta -0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, DeltaMLD <-0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation (P<0.001) and postprocedural MLD (P= 0.008). CONCLUSIONS: Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group.

Angioplasty, Balloon, Coronary↗

Angiographical follow-up after radioactive "Cold Ends" stent implantation: a multicenter trial.

BACKGROUND: Radioactive stents with an activity of 0.75 to 12 microCi have shown >40% edge restenosis due to neointimal hyperplasia and negative remodeling. This trial evaluated whether radioactive Cold Ends stents might resolve edge restenosis by preventing remodeling at the injured extremities. METHODS AND RESULTS: The 25-mm long (15-mm radioactive center and 5-mm nonradioactive ends) Cold Ends stents had an activity of 3 to 12 microCi at implantation. Forty-three stents were implanted in 43 patients with de novo native coronary artery disease. Two procedural, 1 subacute, and 1 late stent thrombosis occurred. A restenosis rate of 22% was observed with a shift of the restenosis, usually occurring at the stent edges of radioactive stents, into the Cold Ends stents. The most severe restenosis occurred at the transition zone from radioactive to nonradioactive segments, a region located in dose fall-off. CONCLUSION: Cold Ends stents did not resolve edge restenosis.

Adult↗

Intracoronary beta-radiation to reduce restenosis after balloon angioplasty and stenting; the Beta Radiation In Europe (BRIE) study.

AIMS: The BRIE trial is a registry evaluating the safety and performance of (90)Sr delivered locally (Beta-Cath TM system of Novoste) to de-novo and restenotic lesions in patients with up to two discrete lesions in different vessels. METHODS AND RESULTS: In total, 149 patients (175 lesions) were enrolled; 62 treated with balloons and 113 with stents. The restenosis rate, the minimal luminal diameter and the late loss were determined in three regions of interest: (a) in a subsegment of 5mm containing the original minimal luminal diameter pre-intervention termed target segment; (b) the irradiated segment, 28 mm in length, and (c) the entire analysed segment, 42 mm in length, termed the vessel segment. Binary restenosis was 9.9% for the target segment, 28.9% for the irradiated segment, and 33.6% for the vessel segment. These angiographic results include 5.3% total occlusions. Excluding total occlusions binary restenosis was 4.9%, 25% and 29.9%, respectively. At 1 year the incidence of major adverse cardiac events placed in a hierarchical ranking were: death 2%, myocardial infarction 10.1%, CABG 2%, and target vessel revascularization 20.1%. The event-free survival rate was 65.8%. Non-appropriate coverage of the injured segment by the radioactive source termed geographical miss affected 67.9% of the vessels, and increased edge restenosis significantly (16.3% vs 4.3%, P=0.004). It accounted for 40% of the treatment failures. CONCLUSION: The results of this registry reflect the learning process of the practitioner. The full therapeutic potential of this new technology is reflected by the restenosis rate at the site of the target segment. It can only be unravelled once the incidence of late vessel occlusion and geographical miss has been eliminated by the prolonged use of thienopyridine, the appropriate training of the operator applying this new treatment for restenosis prevention, and the use of longer sources.

Adult↗

[The immunology-hematology-transfusion department].

New immunotherapies derived from biotechnology offer fascinating perspectives in different fields of medicine including anti-infectious vaccines, cancer, organ transplantation and autoimmune diseases. In this paper, we illustrate how the Department of Immunology can contribute to the development of these new treatments within a academic hospital such as the Erasme Hospital at the Université Libre de Bruxelles.

Allergy and Immunology↗

Abnormal epicardial coronary resistance in patients with diffuse atherosclerosis but "Normal" coronary angiography.

BACKGROUND: Coronary arteries without focal stenosis at angiography are generally considered non-flow-limiting. However, atherosclerosis is a diffuse process that often remains invisible at angiography. Accordingly, we hypothesized that in patients with coronary artery disease, nonstenotic coronary arteries induce a decrease in pressure along their length due to diffuse coronary atherosclerosis. METHODS AND RESULTS: Coronary pressure and fractional flow reserve (FFR), as indices of coronary conductance, were obtained from 37 arteries in 10 individuals without atherosclerosis (group I) and from 106 nonstenotic arteries in 62 patients with arteriographic stenoses in another coronary artery (group II). In group I, the pressure gradient between aorta and distal coronary artery was minimal at rest (1+/-1 mm Hg) and during maximal hyperemia (3+/-3 mm Hg). Corresponding values were significantly larger in group II (5+/-4 mm Hg and 10+/-8 mm Hg, respectively; both P<0.001). The FFR was near unity (0.97+/-0.02; range, 0.92 to 1) in group I, indicating no resistance to flow in truly normal coronary arteries, but it was significantly lower (0.89+/-0.08; range, 0.69 to 1) in group II, indicating a higher resistance to flow. In 57% of arteries in group II, FFR was lower than the lowest value in group I. In 8% of arteries in group II, FFR was <0.75, the threshold for inducible ischemia. CONCLUSION: Diffuse coronary atherosclerosis without focal stenosis at angiography causes a graded, continuous pressure fall along arterial length. This resistance to flow contributes to myocardial ischemia and has consequences for decision-making during percutaneous coronary interventions.

Blood Flow Velocity↗

Fractional flow reserve in patients with prior myocardial infarction.

BACKGROUND: Fractional flow reserve (FFR), an index of coronary stenosis severity, can be calculated from the ratio of hyperemic distal to proximal coronary pressure. An FFR value of 0.75 can distinguish patients with normal and abnormal noninvasive stress testing in case of normal left ventricular function. The present study aimed at investigating the value of FFR in patients with a prior myocardial infarction. Methods and Results-- In 57 patients who had sustained a myocardial infarction >/=6 days earlier, myocardial perfusion single photon emission scintigraphy (SPECT) imaging and FFR were obtained before and after angioplasty. The sensitivity and specificity of the 0.75 value of FFR to detect flow maldistribution at SPECT imaging were 82% and 87%. The concordance between the FFR and SPECT imaging was 85% (P<0.001). When only truly positive and truly negative SPECT imaging were considered, the corresponding values were 87%, 100%, and 94% (P<0.001). Patients with positive SPECT imaging before angioplasty had a significantly lower FFR than patients with negative SPECT imaging (0.52+/-0.18 versus 0.67+/-0.16, P=0.0079) but a significantly higher left ventricular ejection fraction (63+/-10% versus 52+/-10%, P=0.0009) despite a similar degree of diameter stenosis (67+/-13% versus 68+/-16%, P=NS). A significant inverse correlation was found between LVEF and FFR (R=0.29, P=0.049). CONCLUSIONS: The present data indicate (1) that the 0.75 cutoff value of FFR to distinguish patients with positive from patients with negative SPECT imaging is valid after a myocardial infarction and (2) that for a similar degree of stenosis, the value of FFR depends on the mass of viable myocardium.

Angioplasty, Balloon, Coronary↗

Fractional flow reserve to determine the appropriateness of angioplasty in moderate coronary stenosis: a randomized trial.

BACKGROUND: PTCA of a coronary stenosis without documented ischemia at noninvasive stress testing is often performed, but its benefit is unproven. Coronary pressure-derived fractional flow reserve (FFR) is an invasive index of stenosis severity that is a reliable substitute for noninvasive stress testing. A value of 0.75 identifies stenoses with hemodynamic significance. METHODS AND RESULTS: In 325 patients for whom PTCA was planned and who did not have documented ischemia, FFR of the stenosis was measured. If FFR was >0.75, patients were randomly assigned to deferral (deferral group; n=91) or performance (performance group; n=90) of PTCA. If FFR was <0.75, PTCA was performed as planned (reference group; n=144). Clinical follow-up was obtained at 1, 3, 6, 12, and 24 months. Event-free survival was similar between the deferral and performance groups (92% versus 89% at 12 months and 89% versus 83% at 24 months) but was significantly lower in the reference group (80% at 12 months and 78% at 24 months). In addition, the percentage of patients free from angina was similar between the deferral and performance groups (49% versus 50% at 12 months and 70% versus 51% at 24 months) but was significantly higher in the reference group (67% at 12 and 80% at 24 months). CONCLUSIONS: In patients with a coronary stenosis without evidence of ischemia, coronary pressure-derived FFR identifies those who will benefit from PTCA.

Angina Pectoris↗

Endoluminal beta-radiation therapy for the prevention of coronary restenosis after balloon angioplasty. The Dose-Finding Study Group.

BACKGROUND: Beta radiation is effective in reducing vascular neointimal proliferation in animals after injury caused by balloon angioplasty. However, the lowest dose that can prevent restenosis after coronary angioplasty has yet to be determined. METHODS: After successful balloon angioplasty of a previously untreated coronary stenosis, 181 patients were randomly assigned to receive 9, 12, 15, or 18 Gy of radiation delivered by a centered yttrium-90 source. Adjunctive stenting was required in 28 percent of the patients. The primary end point was the minimal luminal diameter six months after treatment, as a function of the delivered dose of radiation. RESULTS: At the time of follow-up coronary angiography, the mean minimal luminal diameter was 1.67 mm in the 9-Gy group, 1.76 mm in the 12-Gy group, 1.83 mm in the 15-Gy group, and 1.97 mm in the 18-Gy group (P=0.06 for the comparison of 9 Gy with 18 Gy), resulting in restenosis rates of 29 percent, 21 percent, 16 percent, and 15 percent, respectively (P=0.14 for the comparison of 9 Gy with 18 Gy). At that time, 86 percent of the patients had had no serious cardiac events. In 130 patients treated with balloon angioplasty alone, restenosis rates were 28 percent, 17 percent, 16 percent, and 4 percent, respectively (P=0.02 for the comparison of 9 Gy with 18 Gy). Among these patients, there was a dose-dependent enlargement of the lumen in 28 percent, 50 percent, 45 percent, and 74 percent of patients, respectively (P<0.001 for the comparison of 9 Gy with 18 Gy). The rate of repeated revascularization was 18 percent with 9 Gy and 6 percent with 18 Gy (P=0.26). CONCLUSIONS: Intracoronary beta radiation therapy produces a significant dose-dependent decrease in the rate of restenosis after angioplasty. An 18-Gy dose not only prevents the renarrowing of the lumen typically observed after successful balloon angioplasty, but actually induces luminal enlargement.

Aged↗

Angiographic and clinical one-year follow-up of the Cordis tantalum coil stent in a multicenter international study demonstrating improved restenosis rates when compared to pooled PTCA and BENESTENT-I data: the European Antiplatelet Stent Investigation (EASI).

The Cordis tantalum coil stent was assessed in a nonrandomized multicenter trial: 275 patients with stable or unstable angina were entered. Clinical follow-up was for 1 year, with repeat angiography at 6 months. The major adverse cardiac event rates (MACE) were 3%, 14%, and 17% at 1, 7, and 13 months, respectively. The procedural success rate was 96% and the subacute occlusion rate 1.5%, in a group of patients over 60% of whom had ACC/AHA type B2 or C lesions. The binary restenosis rate at 6 months was 17.3%. Minimum lumen diameter increased from 1.07 +/- 0.28 mm preprocedure to 2.93 +/- 0.34 mm poststenting and at 6 months was 1.99 +/- 0.69 mm. These results demonstrate that the Cordis tantalum stent can be used to treat complex lesions with good procedural success and low rates of subacute thrombosis and restenosis at 6 months.

Aged↗

Clinical and quantitative coronary angiographic predictors of coronary restenosis: a comparative analysis from the balloon-to-stent era.

OBJECTIVES: We sought to assess whether coronary stents have modified the predictive value of demographic, clinical and quantitative coronary angiographic (QCA) predictors of coronary restenosis. BACKGROUND: A systematic analysis in a large cohort of registries and randomized trials of the percutaneous transluminal coronary angioplasty (PTCA) and stent era has never been performed. METHODS: A total of 9,120 treated lesions in 8,156 patients included in nine randomized trials and 10 registries, with baseline, post-procedural and six-month follow-up QCA analyses, were included in this study. Predictors of restenosis were identified with univariate and multivariate logistic regression analyses. Interaction terms were introduced in the regression equation to evaluate whether the predictors of restenosis were common to both eras or specific for either one of the revascularization techniques. RESULTS: The restenosis rate was 35% after PTCA and 19% after angioplasty with additional stenting. In the univariate analysis, favorable predictors were previous coronary artery bypass graft surgery (CABG), stent use, stent length and a large pre-procedural minimal lumen diameter (pre-MLD); unfavorable predictors were weight, body mass index, diabetes mellitus, multi-vessel disease, lesion length and a high residual post-procedural diameter stenosis (post-DS). Predictors specific for the PTCA population were a large post-procedural MLD (post-MLD) as favorable and a severe pre-procedural DS (pre-DS) as unfavorable. Favorable predictors specific for the stent population were a large post-MLD and a large pre-procedural reference diameter (pre-RD). In the multivariate analysis, the best model included the following favorable predictors: stent use, a large post-MLD, previous CABG and the interaction term between stent use and a large post-MLD; unfavorable predictors were lesion length and diabetes mellitus. CONCLUSIONS: There are no major differences in demographic and clinical predictors of coronary restenosis between PTCA and stent populations. In the modern (stent) era, a severe pre-DS is no longer an unfavorable predictor of restenosis. Still important, but more so in the stent population, is a large post-MLD (optimal result). Finally, a larger pre-RD became a favorable predictor with the advent of stenting.

Aged↗