PubMed Health⌕ Search

Biomedical subjects

Walid Saliba

Publications and source records attributed to Walid Saliba.

47 records · Page 3Linked to original sources

Use of different catheter ablation technologies for treatment of typical atrial flutter: acute results and long-term follow-up.

OBJECTIVES: We report the acute success and long-term follow-up in consecutive patients undergoing catheter ablation of typical right atrial flutter (AFL) using different ablation technologies. METHODS: One hundred and two patients presenting for treatment of AFL to our laboratory were included in the study. Based on availability and physician preference, ablation was performed with either a cooled-tip catheter (39 patients, group I), an 8- or 10-mm tip catheter connected to a high-power radiofrequency (RF) generator (25 patients, group II), or a 4- or 5-mm tip catheter (38 patients, group III). Acute ablation success was achieved in all group II and group III patients. Among the 38 patients undergoing ablation with the conventional catheter tip (group I), crossover to an 8-mm tip or a cooled tip ablation catheter was required in 11 patients (29%). The mean fluoroscopy time was significantly higher in group I (54.3 +/- 26.4 minutes) when compared to group II (39.6 +/- 19.6 minutes; P < 0.05) and group III (40 +/- 16 minutes; P = 0.0.5). After a mean follow up of 20 +/- 5 months no patient in group II experienced recurrence of AFL, whereas 18.4% (7 of 38 patients; P < 0.05) in group I and 10% (4 of 39 patients; P < 0.05) in group III had recurrence of AFL. Ablation technologies designed to obtain larger size lesions appeared to be more effective in achieving acute ablation success of AFL and in limiting the long-term recurrence rate of this arrhythmia.

Atrial Flutter↗

Three-dimensional reconstruction of pulmonary veins in patients with atrial fibrillation and controls: morphological characteristics of different veins.

Multidetector computed tomography can be used to evaluate the anatomy of pulmonary veins (PVs) in patients with AF. The study evaluated two groups. Group 1 included 61 patients assessed following PV ablation with ultrasound of RF energy. Group 2 included 15 patients undergoing ablation for AF and 14 control subjects without a history of AF matched for age and sex. The anatomy of the PVs was analyzed in this group prior to the ablation and compared to controls. Computed tomography was used to measure the ostium of the left superior, left inferior, right superior, right inferior PVs, and the left atrial appendage size. In group 1, PV stenosis was seen in 14 (30%) of 46 patients undergoing ablation with RF energy and in none of the 15 patients receiving ablation with ultrasound energy. In group 2, the ostium size was not different between patients with AF and controls. Similarly, the ostium of the PV that appeared to trigger AF was not larger than the ostium of the remaining veins. A "clustering pattern" of PV branches near the right inferior PV ostium was seen in almost every patient, independent of the presence of the arrhythmia. Computed tomography frequently detects PV stenosis following RF ablation. Ultrasound ablation does not appear to result in PV narrowing. Overall, patients with AF do not have larger sizes of PV ostia. Multiple ramifications from the right inferior PV ostium is a common pattern and may represent a protective anatomic variant.

Atrial Fibrillation↗

Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies.

OBJECTIVES: We conducted this study to compare the efficacy and safety of different catheter ablation technologies and of distal versus ostial pulmonary veins (PV) isolation using the circular mapping technique. BACKGROUND: Electrical isolation of the PVs in patients with atrial fibrillation (AF) remains a technical challenge. METHODS: Two hundred eleven patients (163 men; mean age 53 +/- 11 years) with symptomatic AF were included in this study. In the first 21 patients (group 1), distal isolation (> or = 5 mm from the ostium) was achieved targeting veins triggering AF. In the remaining 190 patients (group 2), ostial isolation of all PVs was performed using 4-mm tip (47 patients), 8-mm tip (21 patients), or cooled-tip (122 patients) ablation catheters. RESULTS: Distal isolation was able to eliminate premature atrial contractions (PACs) and AF in six of 21 patients (29%) and 10 of 34 PVs. After a mean follow-up time of 6 +/- 4 months, no patients treated with the 8-mm tip catheter experienced recurrence of AF, whereas 21% (10 of 47 patients) and 15% (18 of 122 patients) of the patients ablated with the 4-mm tip and the cooled-tip ablation catheters experienced recurrence of AF after a mean follow-up of 10 +/- 3 and 4 +/- 2 months, respectively. Significant complications including stroke, tamponade, and severe stenosis occurred in 3.5% (8/211) of patients. CONCLUSIONS: Catheter technologies designed to achieve better lesion size appeared to have a positive impact on procedure time, fluoroscopy time, number of lesions, and overall efficacy. Although distal isolation can be achieved with fewer lesions, ostial isolation is required in the majority of patients to eliminate arrhythmogenic PACs and AF.

Adult↗

Three-dimensional nonfluoroscopic mapping and ablation of inappropriate sinus tachycardia. Procedural strategies and long-term outcome.

OBJECTIVES: We conducted this study to assess long-term results of three-dimensional (3-D) mapping-guided radiofrequency ablation (RFA) of inappropriate sinus tachycardia (IST). Change in activation after the administration of esmolol was also assessed and compared to the shift documented with successful sinus node (SN) modification. BACKGROUND: The long-term results after RFA of IST have been reported to vary between 27% and 66%. METHODS: Thirty-nine patients (35 women, mean age 31 +/- 9 years) with debilitating IST were included in the study. The area around the earliest site of activation recorded using the 3-D mapping system was targeted for ablation. The shift in the earliest activation site after administration of esmolol was compared with the shift after RFA. RESULTS: The heart rate at rest and in drug-free state ranged between 95 and 125 beats/min (mean 99 +/- 14 beats/min). Sinus node was successfully modified in all patients. Following ablation, the mean heart rate dropped to 72 +/- 8 beats/min, p < 0.01. The extent of the 3-D shift in caudal activation along the crista terminalis was more pronounced after RFA than during esmolol administration (23 +/- 11 mm vs. 7 +/- 5 mm, respectively, p < 0.05). No patient required pacemaker implantation after a mean follow-up time of 32 +/- 9 months; 21% of patients experienced recurrence of IST and were successfully re-ablated. CONCLUSIONS: Three-dimensional electroanatomical mapping seems to facilitate and improve the ablation results of IST. The difference in caudal shift seen after esmolol administration and following SN modification suggests that adrenergic hypersensitivity is not the only mechanism responsible for the inappropriate behavior of the SN.

Adult↗

Matching approved "nondedicated" hardware to obtain biventricular pacing and defibrillation: feasibility and troubleshooting.

Biventricular ICDs may offer increased benefit for patients with severe congestive heart failure and ventricular arrhythmia. Currently there are no approved dedicated biventricular ICDs available. Twenty-one consecutive patients who had approved nondedicated hardware implanted for biventricular pacing and defibrillation were included in this study. All device therapies were evaluated using stored electrograms. During mean follow-up at 13 +/- 7 months, 8 (36%) patients had inappropriate shocks. Ventricular fibrillation therapy was delivered for slow ventricular tachycardia because of double counting in two patients. In one patient, AV nodal reentrant tachycardia below detection rate cut off triggered device therapy because of ventricular double counting. Sinus tachycardia or premature atrial contraction initiating AV conduction and ventricular double counting resulted in shocks in five patients. The number of shocks per patient ranged from 1 to 64. Two patients required transient disconnection of the LV lead and subsequent ICD generator replacement for premature battery depletion. Two patients required AV junction ablation and three needed slow pathway ablation. Two patients were treated by upgrading to a device that was capable of a higher atrial tracking rate. The patients with impaired AV conduction or constant ventricular pacing did not have inappropriate therapy for sinus tachycardia or supraventricular arrhythmia. Use of conventional nondedicated hardware for biventricular pacer/defibrillator is feasible but should be considered only in patients with poor AV node function or less likely to require antitachycardic therapy, to avoid ICD double counting of ventricular sensed events and consequent high incidence of inappropriate therapies.

Adult↗

Nonexcitatory stimulus delivery improves left ventricular function in hearts with left bundle branch block.

INTRODUCTION: Preliminary data in a heart failure animal model and isolated muscle preparation have suggested that nonexcitatory stimulation (NES) improves left ventricular (LV) function. METHODS AND RESULTS: We compared biventricular (BV) pacing with NES in an animal model with left bundle branch block (LBBB). The left bundle branch (LBB) was ablated in eight normal heart pigs and led to >50% increase in QRS duration (mean 100 +/- 15 msec). End-diastolic LV pressure, end-systolic LV pressure, LV pressure (LV dP/dtmax), aortic pulse pressure, and LV ejection fraction were measured before pre-LBB ablation and compared with post-LBB ablation (AAI pacing), BV pacing, NES delivery, and BV+NES. Moreover, to evaluate LV diastolic function, we measured the early (E wave) and late flows (A wave) through the mitral valve using spectral Doppler. Compared with post-LBB ablation, NES led to a significant increase in LV dP/dtmax (1,047 +/- 224 mmHg/sec vs 897 +/- 116 mmHg/sec; P < 0.05), LV ejection fraction (64% +/- 18% vs 49% +/- 17%; P < 0.05), and aortic pulse pressure (18 +/- 3.6 mmHg vs 16 +/- 2.8 mmHg; P < 0.05). Moreover, improvement in LV hemodynamic parameters was significantly higher during NES delivery when compared with BV pacing. No significant changes in E wave, A wave, and E/A were recorded during NES, NES+BV, and BV pacing. CONCLUSION: Our preliminary data demonstrate that NES is superior to BV pacing in improving LV function in an animal model with LBBB. Moreover, we demonstrated that NES does not affect transmitral valve flow and subsequently LV diastolic function.

Animals↗

Circumferential ultrasound ablation for pulmonary vein isolation: analysis of acute and chronic failures.

INTRODUCTION: In patients undergoing circumferential isolation of the pulmonary veins with an ultrasound ablation system, we analyzed the temperatures achieved while delivering circumferential ostial lesions in the pulmonary veins. We also reviewed the angiograms obtained during the procedure and identified anatomic variants that could be responsible for ineffective lesion formation. METHODS AND RESULTS: During the early clinical use in 33 patients, a total of 85 veins were ablated. A mean of 16.9 +/- 12.3 ablations were delivered per patient, and a mean of 6.7 ablations per vein were applied. Entry block was assessed by placing a deflectable octapolar or a circular catheter in the vein. The following anatomic characteristics and technical limitations were identified as possible reasons for ineffective energy delivery: (1) funnel-shaped ostium; (2) ostial diameter larger than the balloon diameter; (3) inability to deliver the catheter to the right inferior or other vein ostia; (4) ostial instability; (5) early branching of the vein; and (6) eccentric position of the ultrasound transducer in the vein. In patients with recurrence of atrial fibrillation, 40% of the ostial lesions reached a temperature >60 degrees C. However, in patients cured by the ablation, 64% of the ostial lesions reached a temperature >60 degrees C (P < 0.06). At least 12 of the 20 chronic recurrences could have been related to technical limitations of the first system. Duration of atrial fibrillation and eccentric deployment of the ultrasound transducer were more frequent in patients with recurrence of arrhythmias at follow-up. CONCLUSION: Ostial anatomy of the veins may affect delivery of ultrasound energy to achieve circumferential lesions. Energy delivery at the ostium with a temperature > 60 degrees C may be important to maximize success. Reconfiguration of the system to overcome the shortcomings identified in the initial experience could increase its performance.

Adult↗

Ventricular fibrillation: ablation of a trigger?

We report the case of a patient with recurrent ventricular fibrillation (VF) and no evidence of structural heart disease. VF was consistently initiated by a relatively early-coupled premature ventricular contraction with identical morphology on each occasion. Treatment with antiarrhythmic agents failed to suppress the arrhythmia. Electrophysiologic testing showed high-frequency potential at the earliest activation site, and radiofrequency ablation resulted in abolition of the ventricular ectopy with no further VF recurrence. Suppression of VF arising from focal triggers in patients with frequent ventricular ectopy and normal heart can be achieved with catheter ablation, but further studies are needed to evaluate the prevalence of such a mechanism.

Adult↗