Consistent non-cartesian off-axis MRI quality: calibrating and removing multiple sources of demodulation phase errors.

The consistency of off-axis MRI with non-Cartesian sequences across a large number of scanners is highly variable. Improper timing alignment of the gradient fields, data acquisition system, and real-time frequency demodulation reference signal, which are necessary for off-axis imaging, is an important source of this variability. In addition, eddy currents and anisotropic gradient delays cause deviations in k-space trajectories that in turn make the demodulation reference signals inaccurate. A method is presented to quickly measure the timing error in the frequency demodulation reference signal and separate it from anisotropic gradient delays. k-Space deviations, as measured with a previous gradient calibration technique, are shown to be a second source of demodulation phase errors that degrade image quality. Using the timing delay and k-space deviations, a retrospective phase correction is applied to each k-space sample before the data are regridded during reconstruction. The timing delays of four MR scanners were measured to be 4.2-7.5 micros below the manufacturer's suggested delay. Significant degradation in 3D radial (3D projection reconstruction (PR)) knee and breast images are retrospectively corrected while a partial prospective correction is applied for spiral imaging. The method allows for more consistent performance of non-Cartesian sequences across multiple scanners without operator intervention.

Algorithms↗

Background suppression in time-resolved MR angiography without mask acquisition or operator intervention.

PURPOSE: To suppress static and background tissue in time-resolved MRA studies of the full thorax or abdomen without the need of a mask image or operator intervention. MATERIALS AND METHODS: The time course of each voxel is projected onto the orthogonal complement space of a matrix that spans static and linearly enhancing signal vectors. The norm of the solution, or the projection length, acts as a confidence measure for segmenting vascular and nonvascular tissue. Voxels whose confidence measures fall below an automatically detected threshold value are considered nonvascular. These voxels undergo an increasing level of suppression as the distance of the confidence measure from the threshold grows. RESULTS: MIPs of processed volunteer studies were compared to the original unaltered studies to assess the improvement in clarity of vascular structures. Qualitative and quantitative comparisons of full body MIPs verify excellent suppression of nonvascular tissue in time-resolved three-dimensional image volumes. CONCLUSION: Contrast increased by an average factor of 13 in five volunteer studies, quantitatively emphasizing the improvement in MIP processing achieved by this method. Improvement in the clarity of vascular structures in subvolume MIPs is also demonstrated to emphasize the significant increase in ease with which regions of interest can be identified.

Abdomen↗

Advances in locally constrained k-space-based parallel MRI.

In this article, several theoretical and methodological developments regarding k-space-based, locally constrained parallel MRI (pMRI) reconstruction are presented. A connection between Parallel MRI with Adaptive Radius in k-Space (PARS) and GRAPPA methods is demonstrated. The analysis provides a basis for unified treatment of both methods. Additionally, a weighted PARS reconstruction is proposed, which may absorb different weighting strategies for improved image reconstruction. Next, a fast and efficient method for pMRI reconstruction of data sampled on non-Cartesian trajectories is described. In the new technique, the computational burden associated with the numerous matrix inversions in the original PARS method is drastically reduced by limiting direct calculation of reconstruction coefficients to only a few reference points. The rest of the coefficients are found by interpolating between the reference sets, which is possible due to the similar configuration of points participating in reconstruction for highly symmetric trajectories, such as radial and spirals. As a result, the time requirements are drastically reduced, which makes it practical to use pMRI with non-Cartesian trajectories in many applications. The new technique was demonstrated with simulated and actual data sampled on radial trajectories.

Abdomen↗

3D fluoroscopy with real-time 3D non-cartesian phased-array contrast-enhanced MRA.

For optimized CE-MRA of the chest and abdomen, the scan time and breath-hold must be coordinated with the arrival of contrast. A 3D fluoroscopy system is demonstrated that performs real-time 3D projection reconstruction acquisition, reconstruction, and visualization using only the standard scanner hardware and operator console workstation. Unlike 2D fluorotriggering techniques, no specification of a monitoring slab or careful placement of the imaging volume is required. 3DPR data are acquired continuously throughout the examination using an eight-channel receiver and 1 s interleaved subframes. The data are reconstructed using 1 s segments for real-time monitoring with 0.8-cm isotropic spatial resolution over the entire torso, allowing full-volume axial, coronal, and sagittal MIPs to be displayed simultaneously with minimal latency. The system later uses the same scan data to generate high-spatial-resolution time-resolved sequences of the breath-hold interval. The 3D fluoroscopy system was validated on phantoms and human volunteers.

Artifacts↗

Upper limb dynamic responses to impulsive forces for selected assembly workers.

This study evaluated the upper limb, dynamic, mechanical response parameters for 14 male assembly workers recruited from selected jobs based on power tool use. It was hypothesized that the type of power tool operation would affect stiffness, effective mass, and damping of the upper extremity; and workers with symptoms and positive physical examination findings would have different mechanical responses than asymptomatic workers without physical examination findings. Participants included operators who regularly used torque reaction power hand tools, such as nutrunners and screwdrivers, and nontorque reaction power hand tools, such as riveters. The mechanical parameters of the upper limb were characterized from the loading response of an apparatus having known dynamic properties while worker grasps an oscillating handle in free vibration. In addition, all workers underwent a physical examination, magnetic resonance imaging, and completed a symptom survey. Workers were categorized as controls or cases based on reported forearm symptoms and physical exam findings. A total of seven workers were categorized as cases and had less average mechanical stiffness (46%, p > 0.01), damping (74%, p > 0.01), and effective mass (59%, p > 0.05) than the seven workers categorized as controls. Magnetic resonance imaging (MRI) findings suggestive of muscle edema were observed for two workers classified as cases and who regularly used torque reaction power tools. No MRI enhancement was observed in the seven subjects who did not regularly use torque reaction power tools. The ergonomic consequences of less stiffness, effective mass, and damping in symptomatic workers may include reduced capacity to react against rapidly building torque reaction forces encountered when operating power hand tools.

Adult↗

Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory.

Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CE-MRA) has gained in popularity relative to X-ray Digital Subtraction Angiography because it provides three-dimensional (3-D) spatial resolution and it is less invasive. We have previously presented methods that improve temporal resolution in CE-MRA while providing high spatial resolution by employing an undersampled 3-D projection (3D PR) trajectory. The increased coverage and isotropic resolution of the 3D PR acquisition simplify visualization of the vasculature from any perspective. We present a new algorithm to develop a set of time-resolved 3-D image volumes by preferentially weighting the 3D PR data according to its acquisition time. An iterative algorithm computes a series of density compensation functions for a regridding reconstruction, one for each time frame, that exploit the variable sampling density in 3D PR. The iterative weighting procedure simplifies the calculation of appropriate density compensation for arbitrary sampling patterns, which improve sampling efficiency and, thus, signal-to-noise ratio and contrast-to-noise ratio, since it is does not require a closed-form calculation based on geometry. Current medical workstations can display these large four-dimensional studies, however, interactive cine animation of the data is only possible at significantly degraded resolution. Therefore, we also present a method for interactive visualization using powerful graphics cards and distributed processing. Results from volunteer and patient studies demonstrate the advantages of dynamic imaging with high spatial resolution.

Algorithms↗

Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction.

Three-dimensional projection reconstruction (3D PR)-based techniques are advantageous for steady-state free precession (SSFP) imaging for several reasons, including the capability to achieve short repetition times (TRs). In this paper, a multi-half-echo technique is presented that dramatically improves the data-sampling efficiency of 3D PR sequences while it retains this short-TR capability. The k-space trajectory deviations are measured quickly and corrected on a per-sample point basis. A two-pass RF cycling technique is then applied to the dual-half-echo implementation to generate fat/water-separated images. The resultant improvement in the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) was demonstrated in volunteer studies. Volumetric images with excellent spatial resolution, coverage, and contrast were obtained with high speed. The non-contrast-enhanced SSFP studies show that this technique has promising potential for MR angiography (MRA).

Brain↗

Time-resolved undersampled projection reconstruction magnetic resonance imaging of the peripheral vessels using multi-echo acquisition.

The hybrid projection reconstruction (PR) imaging provides high temporal resolution through an undersampled PR acquisition for the in-plane dimensions and Cartesian slice encoding for the through-plane dimension. The undersampling of projection data introduces streak artifact, which may severely compromise image quality. This study reports on a combination of multi-echo acquisition with time-resolved undersampled PR imaging and its application to peripheral magnetic resonance angiography. Multi-echo acquisition improved imaging speed effectively, thereby reducing the undersampling streak artifact and improving the temporal resolution. The gradient distortion was reduced through gradient calibration and accurate k-space trajectory measurement.

Artifacts↗

Fat/water separation in single acquisition steady-state free precession using multiple echo radial trajectories.

Phase detection in fully refocused SSFP imaging has recently allowed fat/water separation without preparing the magnetization or using multiple acquisitions. Instead, it exploits the phase difference between fat and water at an echo time at the midpoint of the TR. To minimize the TR for improved robustness to B0 inhomogeneity, a 3D projection acquisition collecting two half echoes at the beginning and end of each excitation was previously implemented. Since echoes are not formed at the midpoint of the TR, this method still requires two passes of k-space for fat/water separation. A new method is presented to linearly combine the half echoes to separate fat and water in a single acquisition. Separation using phase detection provides superior contrast between fat and water voxels. Results from high resolution angiography and musculoskeletal studies with improved robustness to inhomogeneity and a 50% scan time reduction compared to the two pass method are presented.

Adipose Tissue↗

Anatomical and mechanical changes following repetitive eccentric exertions.

BACKGROUND: Submaximal eccentric exertions occur occupationally when rapidly rising tool-generated forces exceed the operator's capacity to react against them. The purpose of this study was to investigate the effects of short duration repetitive submaximal eccentric forearm exertions at levels comparable to industrial power hand tool use on dynamic mechanical properties (stiffness, effective mass and damping) and on forearm edema. METHODS: This study investigated changes following short term repetitive submaximal eccentric exertions comparable to occupational levels. Eight male participants exercised eccentrically for 30 min at 50% of isometric maximum voluntary contraction forearm supination in a posture and loading similar to power hand tool use in the workplace. Dynamic mechanical properties (stiffness, effective mass and damping) of the upper limb were measured before, immediately following, and daily for three days after the activity. An MRI scan to assess edema was also performed for five of the participants before, on day one and day three following the activity. FINDINGS: Mechanical stiffness decreased 51% (P < 0.05) and effective mass decreased 43% (P = 0.052) immediately following eccentric exercise. Average isometric strength also decreased 42% immediately following exercise (P < 0.01) and pain persisted for two days. The recovery of static strength however was not correlated with changes in mechanical stiffness (r = 0.56) or effective mass (r = 0.30). The exercised arms had a 360% increase (P < 0.01) in supinator-extensor T(2) relaxation time difference, a quantifiable measure of edema, one day after exercise while the non-exercised arms had no significant changes. INTERPRETATION: Changes in both T(2) relaxation time, indicative of edema, and forearm mechanical properties, were observed following short duration submaximal repetitive exercise. If similar changes in dynamic mechanical properties of the upper extremity occur following repetitive submaximal eccentric activity in the workplace, they could negatively impact the ability of the arm to react to rapid forceful loading during repetitive industrial work activities and increase mechanical loading of the upper limb.

Adaptation, Physiological↗

PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography.

BACKGROUND AND PURPOSE: Three-dimensional phase-contrast (3DPC) is limited by long imaging times, limited coverage, flow artifacts, and the need to perform multiple additional 2D examinations (2DPC) to measure flow. A highly undersampled 3D radial acquisition (isotropic-voxel radial projection imaging [PCVIPR]) makes it possible to increase the product of volume coverage and spatial resolution by a factor of 30 for the same imaging time as conventional Cartesian 3DPC. This provides anatomic information over a large volume with high isotropic resolution and permits retrospective measurement of average flow rates throughout the volume. METHODS: PCVIPR acquires a reference and three flow-encoded acquisitions for each VIPR projection. Complex difference images were formed by combining information from all flow directions. Following retrospective definition of planes perpendicular to selected vessels, volume flow rates were determined by using phase-difference information. The accuracy of average flow measurement was investigated in a phantom and in six volunteers. Anatomic PCVIPR images acquired in three patients and three volunteers by using a 384(3) matrix were compared with conventional Cartesian 3DPC. RESULTS: The flow validation produced R2 = 0.99 in vitro and R2 = 0.97 in vivo. PCVIPR produced minimal streak and pulsatile flow artifacts. PCVIPR produced far higher resolution and volume coverage in comparable imaging times. The highest acceleration factors relative to 3DPC were achieved by using gadolinium-contrast material. Ultimately, acceleration factors are limited by signal-to-noise ratio. CONCLUSION: PCVIPR rapidly provides isotropic high-resolution angiographic images and permits retrospective measurement of average flow rate throughout the volume without the need to prescribe multiple 2D acquisition planes.

Adult↗

Improved spectral selectivity and reduced susceptibility in SSFP using a near zero TE undersampled three-dimensional PR sequence.

PURPOSE: To improve the performance of fat/water separation and reduce the sensitivity to susceptibility variation in balanced SSFP sequences. MATERIALS AND METHODS: Decreasing the repetition time (TR) reduces susceptibility artifacts in SSFP imaging. A shorter TR may also improve the spectral selectivity obtained when linearly combining data acquired using different radiofrequency phase cycling schedules. The desired short TR is achieved by using an angularly undersampled three-dimensional radial acquisition sequence that achieves a near zero echo time (TE) and also a short TR. RESULTS: Images from human volunteers demonstrate broad coverage of the cervical spine and knee with isotropic resolution. Excellent fat/water separation is achieved in these studies. CONCLUSION: The short TR capability of the proposed sequence greatly improves the fat suppression in SSFP imaging. High-resolution volumetric T2-like contrast imaged with reduced susceptibility artifacts can be obtained from a single acquisition using this technique.

Cartilage, Articular↗

Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction.

PURPOSE: To investigate the application of time-resolved vastly undersampled isotropic projection reconstruction (VIPR) in contrast-enhanced magnetic resonance angiography of the distal extremity (single station), and peripheral run-off vasculature in the abdomen, thigh, and calf (three stations). MATERIALS AND METHODS: Time-resolved distal extremity imaging was performed using VIPR sequence through the comparison of two acquisition matrix sizes: 256 with TR/TE=3.7/1.4 msec and 320 with TR/TE=4.5/1.8 msec under the same scan time of two minutes. VIPR acquisition was combined with a bolus-chase technique to image the peripheral run-off vasculature. The time-resolved images were reconstructed using a revised sliding window reconstruction filter whose temporal aperture remained narrow for low spatial frequencies and increased quadratically to include all the projection data for high spatial frequencies. RESULTS: The new temporal filter significantly suppressed the undersampling streak artifacts and venous contamination, while maintaining a high temporal resolution. Both high spatial resolution (ranging from 1.56 x 1.56 x 1.56 mm to 1.25 x 1.25 x 1.25 mm) and high temporal resolution (three seconds per frame) distal extremity images and peripheral run-off images were generated using time-resolved VIPR acquisition, which provides isotropic spatial resolution and isotropic coverage. CONCLUSION: Time-resolved VIPR acquisition was demonstrated to be well suited for distal extremity imaging by providing isotropic spatial resolution, isotropic coverage, and high temporal resolution. The combination of time-resolved VIPR and bolus chase technique provided a novel approach for peripheral run-off examinations.

Abdomen↗

Time-resolved 3D MR angiography of the abdomen with a real-time system.

This study reports on the implementation of a real-time MR acquisition, reconstruction, and display system on standard hardware for 3D contrast-enhanced MR abdominal angiography. The system allows for dynamic imaging of the contrast passage with good spatial resolution in a single breathhold. It is capable of synchronously acquiring and processing multiple coil data. Bolus arrival can be detected confidently from the display of MIP images from sagittal 3D slabs with moderate spatial resolution. Upon detection of the contrast agent, the patient is asked to hold their breath and a novel 3D acquisition is started for a coronal volume. Temporal imaging within the breathhold is achieved through applying a modified time-resolved imaging of contrast kinetics (TRICKS) technique with elliptical centric view ordering. The technique displays contrast passage from the arterial phase through enhancement of the hepatic venous system. It also provides the ability to quantify motion of the diaphragm over a long breathhold.

Abdomen↗

Floating table isotropic projection (FLIPR) acquisition: a time-resolved 3D method for extended field-of-view MRI during continuous table motion.

In this work, 3D vastly undersampled isotropic projection (VIPR) acquisition is used simultaneously with continuous table motion to extend the superior/inferior (S/I) FOV for MR angiograms. The new technique is termed floating table isotropic PR (FLIPR). The use of 3D PR in conjunction with table motion obviates the need to locate and prescribe imaging volumes containing the major blood vessels over the large superior-inferior (S/I) ranges encountered in whole-body imaging. In addition, the FLIPR technique provides extended anterior-posterior (A/P) abdominal coverage, isotropic spatial resolution, and temporal resolution. In volunteer studies, FLIPR MR angiograms with 1.6-mm isotropic spatial resolution that approached whole body in extent were acquired in less than 2 min.

Contrast Media↗

Combined time-resolved and high-spatial-resolution 3D MRA using an extended adaptive acquisition.

PURPOSE: To combine the benefits of time-resolved dynamic imaging and single elliptical centric acquisitions in a reasonable scan time. MATERIALS AND METHODS: A time series of images with moderate spatial resolution was acquired using the 3D Time-Resolved Imaging of Contrast KineticS (3D TRICKS) technique with elliptical centric encoding during contrast arrival. Following venous opacification, a complete large centrically encoded k-space volume was acquired. The high-spatial-frequency portions of this volume were combined with a 3D TRICKS time frame to form a high-resolution image. An additional single image is formed by suppressing background and signal averaging all acquired data, including post-venous low-spatial-frequency data. For this image, 2D temporal correlation analysis is used to suppress low-spatial-frequency vein contributions. Arrival time and spatial correlations are used to suppress background. RESULTS: The 3D TRICKS time frame may be selected to ensure a combined high-resolution image that has optimal central k-space sampling for any vascular region. The single image formed by signal averaging all acquired data has increased contrast-to-noise (CNR) and signal-to-noise (SNR) ratios. CONCLUSION: The advantages of time-resolved and high-spatial-resolution imaging were combined using an extended dual-phase acquisition. Some SNR and CNR gain was achieved by signal averaging. This process is facilitated by background and vein suppression.

Animals↗

Short echo time MR spectroscopic imaging of the lung parenchyma.

PURPOSE: To perform short echo time MR spectroscopic imaging of the lung parenchyma on normal volunteers. MATERIALS AND METHODS: A short echo time projection-reconstruction spectroscopic imaging sequence was implemented on a commercial 1.5T whole body MRI scanner. Images and spectra of the lung parenchyma were obtained from five normal volunteers. Breath-held spectroscopic imaging was also performed. RESULTS: Spectroscopic imaging of short-T2* species allows visualization of different anatomic structures based upon their frequency shifts. A characteristic peak from the parenchyma was seen at three ppm from water frequency. CONCLUSION: Short echo time MR spectroscopic imaging of the lung parenchyma was demonstrated in normal volunteers. This method may improve proton imaging of the lungs and add specificity to the diagnosis of pulmonary disease.

Adult↗

Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory.

Time-resolved contrast-enhanced 3D MR angiography (MRA) methods have gained in popularity but are still limited by the tradeoff between spatial and temporal resolution. A method is presented that greatly reduces this tradeoff by employing undersampled 3D projection reconstruction trajectories. The variable density k-space sampling intrinsic to this sequence is combined with temporal k-space interpolation to provide time frames as short as 4 s. This time resolution reduces the need for exact contrast timing while also providing dynamic information. Spatial resolution is determined primarily by the projection readout resolution and is thus isotropic across the FOV, which is also isotropic. Although undersampling the outer regions of k-space introduces aliased energy into the image, which may compromise resolution, this is not a limiting factor in high-contrast applications such as MRA. Results from phantom and volunteer studies are presented demonstrating isotropic resolution, broad coverage with an isotropic field of view (FOV), minimal projection reconstruction artifacts, and temporal information. In one application, a single breath-hold exam covering the entire pulmonary vasculature generates high-resolution, isotropic imaging volumes depicting the bolus passage.

Abdomen↗