PubMed Health⌕ Search

Biomedical subjects

Walter Heindel

Publications and source records attributed to Walter Heindel.

At least 19 recordsLinked to original sources

The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT.

The purpose of this study was to assess the effect of dose reduction and the potential of noise reduction filters on image quality and the detection of liver lesions using MSCT. Twenty-nine patients with a total of 40 liver lesions underwent 16-slice CT (120 kV; 180 mAs). Virtual noise was added to CT raw datasets simulating effective mAs levels of 155, 130, 105, 80, 55, 30 and 10 mAs. All datasets were post-processed with an edge-preserving noise-reduction filter (ANR-3D), yielding a total of 15 datasets per patient. Ten radiologists performed independent evaluations of image quality, the presence of liver lesions and diagnostic confidence. Quantitative noise and contrast-to-noise ratios (CNR) were obtained. Superior image quality (P < 0.02), reduction of image noise (P < 0.001) and the increase of lesion-to-liver CNR (P < 0.001) were observed in images processed with the ANR-3D filter. Sensitivity for lesion detection remained unchanged down to 105 mAs (CTDI(w) 6.6 mGy) without filter and 80 mAs (CTDI(w) 5.1 mGy) with ANR-3D. Confidence was rated significantly higher for datasets reconstructed with ANR-3D. The use of a noise-reducing, but edge-preserving filter (ANR-3D) is a promising option to reduce further the radiation dose in liver CT.

Adult↗

Cognitive coping style modulates neural responses to emotional faces in healthy humans: a 3-T FMRI study.

Repression designates coping strategies that aim to shield the organism from distressing stimuli by disregarding their aversive characteristics. In contrast, sensitization comprises coping strategies that are employed to reduce situational uncertainty such as analyzing the environment. Functional magnetic resonance imaging was used to study neural correlates of coping styles during the perception of threatening and nonthreatening socially relevant information. Pictures of human faces bearing fearful (ambiguously threatening), angry (unambiguously threatening), happy (nonthreatening), and neutral expressions were presented masked and unmasked. Two groups of subjects were examined who were defined as consistent repressors versus consistent sensitizers with the Mainz Coping Inventory. Sensitizers tended to exhibit stronger neural responses in the amygdala to unmasked fearful faces compared with repressors. Overall, repressors were cortically more responsive to fearful (ambiguously threatening) and happy (nonthreatening) facial expressions than sensitizers, whereas sensitizers presented an enhanced responsivity to angry faces in several prefrontal areas, that is, unambiguously threatening expressions. Results from time series analyses suggest that sensitizers could exhibit less top-down cortical regulation of the amygdala than repressors in the processing of fearful faces. An increased responsivity of the amygdala to ambiguously threatening stimuli may represent a biological determinant of sensitizers' feelings of uncertainty.

Adaptation, Psychological↗

Amygdala reactivity predicts automatic negative evaluations for facial emotions.

The amygdala is a key structure in a limbic circuit involved in the rapid and unconscious processing of facial emotions. In the present study, the role of the amygdala in automatic, involuntary appraisal processes, which are believed to be a crucial component of emotion processing, was investigated in 23 healthy subjects. Amygdala activity was recorded in response to masked displays of angry, sad, and happy facial expressions using functional magnetic resonance imaging (fMRI). In a subsequent experiment, the subjects performed a masked affective priming task that characterizes automatic emotion processing by investigating the biasing effect of subliminally presented emotional faces on evaluative ratings to subsequently presented neutral stimuli. In the affective priming task, significant valence-congruent evaluation manipulation was observed. Subjects rated neutral targets more positively if they were primed by happy faces. Significant correlations were found between amygdala responses to masked negative facial expressions and negative evaluation shifts elicited by the corresponding emotion quality in the affective priming task. Spontaneous amygdala reactivity to facial emotions appears to be a determinant of automatic negative evaluative response tendencies. This finding might shed some light on how amygdala hyperresponsivity contributes to negative cognitive biases commonly observed in affective disorders.

Adult↗

In vivo imaging of integrin alpha v beta 3 expression using fluorescence-mediated tomography.

PURPOSE: Optical imaging would be desirable for cancer diagnostics since it can potentially resolve relevant oncological target structures in vivo. We therefore synthesised an alpha v beta(3) targeted fluorochrome and imaged tumour xenografts with different alpha v beta(3) expression levels using both planar and tomographic optical imaging methods. METHODS: An alpha v beta(3)-targeted RGD peptide was labelled with a cyanine dye (Cy 5.5). Binding of the optical tracer was tested on M21 melanoma (n=5), HT-1080 fibrosarcoma (n=6) and MCF-7 adenocarcinoma (n=5) cells and their tumour xenografts. All optical imaging studies were performed using two-dimensional planar fluorescence reflectance imaging (FRI) technology and three-dimensional fluorescence-mediated tomography (FMT). RESULTS: In vitro, the peptide-dye conjugate showed a clear binding affinity to alpha v beta(3)-positive M21 and HT-1080 cells while alpha v beta(3)-negative MCF-7 cells and pre-dosing with the free RGD peptide revealed little to no fluorescence. In vivo, tumour xenografts were clearly visualised by FRI and FMT up to 24 h post injection. FMT allowed quantification of the fluorochrome distribution in deeper tissue sections showing an average fluorochrome concentration of 417.61 +/- 105.82 nM Cy 5.5 (M21), 353.68 +/- 54.02 nM Cy 5.5 (HT-1080) and 262.83 +/- 155.36 nM Cy 5.5 (MCF-7) in the target tissue 60 min after tracer administration. Competition with the free RGD peptide resulted in a reduction in the fluorochrome concentration in M21 tumour tissue (294.35 +/- 84.27 nM). CONCLUSION: RGD-Cy 5.5 combined with novel tomographic optical imaging methods allows non-invasive imaging of tumour-associated alpha v beta(3) expression and may thus be a promising strategy for sensitive evaluation of tumour target expression.

Animals↗

Assessment of bone marrow angiogenesis in patients with acute myeloid leukemia by using contrast-enhanced MR imaging with clinically approved iron oxides: initial experience.

PURPOSE: To prospectively assess bone marrow (BM) angiogenesis in patients with acute myeloid leukemia (AML) by using iron oxide-enhanced magnetic resonance (MR) imaging. MATERIALS AND METHODS: The study was institutional ethics committee approved. Informed signed consent was obtained from each study participant. The requirement for informed consent for use of data from a reference database was waived. Eleven patients (seven women, four men; mean age, 53 years+/-4.40 [standard deviation]) with an initial diagnosis of AML were enrolled in the study and underwent T2*-weighted two-echo echo-planar MR imaging of the pelvis before and after intravenous injection of a clinically approved iron oxide blood-pool contrast agent. Six healthy control subjects (one woman, five men; mean age, 35 years+/-2.31) were examined with the same MR protocol. The iron oxide-induced change in R2* relaxation rate (DeltaR2*) was calculated, and the vascular volume fraction (VVF) of the BM was derived by dividing the DeltaR2* of the BM by the DeltaR2* of the muscle. Parametric DeltaR2* maps were calculated to visualize vessel distribution. Patients underwent BM biopsy for correlative determination of microvessel density (MVD) and vascular endothelial growth factor (VEGF). Differences in DeltaR2*, VVF, VEGF, and MVD were compared by using the Wilcoxon rank sum test. RESULTS: DeltaR2* maps showed prominent areas of highly vascularized BM in the patients with AML, whereas the control subjects had moderately vascularized BM with homogeneous vessel distribution. Quantitative analysis revealed VVF values to be significantly higher in patients with AML than in control subjects: The mean VVF in the pelvis was 9.18%+/-1.54 for patients versus 3.91%+/-0.61 for control subjects (P=.010). In accordance with MR results, MVD (P=.009) and VEGF expression (P=.017) were significantly elevated in the AML group compared with values in the control group. CONCLUSION: Iron oxide-enhanced MR imaging enables assessment of BM angiogenesis in patients with AML.

Bone Marrow Neoplasms↗

Glial cell activation in a subgroup of patients with schizophrenia indicated by increased S100B serum concentrations and elevated myo-inositol.

Post-mortem and in-vivo studies support the hypothesis that astrocytes might be involved in the pathogenesis of schizophrenia. To further substantiate this hypothesis two markers of astroglial activation (myo-inositol, S100B) acquired with independent methods ((1)H-MRS, quantitative immunoassay) were concomitantly measured in schizophrenic patients. Patients with increased S100B levels showed elevated myo-inositol concentrations. This pilot study demonstrates a concomitant elevation of two markers indicating astrocyte activation in a subgroup of schizophrenic patients.

Adult↗

Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging.

This study compares quantitative and qualitative information on global and regional left ventricular (LV) function obtained with multidetector-row computed tomography (MDCT) with that obtained with magnetic resonance imaging (MRI) in patients with a high prevalence of LV wall motion abnormalities. Thirty patients (19 male, 63.7+/-15.1 years) with myocardial infarction (n=12), coronary artery disease (n=9), arrhythmogenic right ventricular cardiomyopathy (n=6), and dilation cardiomyopathy (n=3) were included. Segmental LV wall motion (LV-WM) was assessed using a 4-point scale. Wall thickness measurements were calculated in diastolic and systolic short axis images. Two hundred and fifty-two out of 266 (94.7%) normal and 189 out of 214 (88.3%) segments with decreased wall motion were correctly identified by MDCT, yielding a sensitivity of 88% and specificity of 95% for identification of wall motion abnormalities. LV-WM scores were identical in 86.7% of 480 segments (kappa=0.809). MDCT had a tendency to underestimate the degree of wall motion impairment. Interobserver agreement was lower in MDCT (66.5%) than in MRI (89.1%; p<0.01). Normokinetic segments are reliably identified with MDCT. Sensitivity for detection and accurate classification of LV wall motion abnormalities need to be improved. Better temporal resolution of the CT system seems to be the most important factor for enhancing MDCT performance.

Adrenergic beta-Antagonists↗

Cognitive impairment and in vivo metabolites in first-episode neuroleptic-naive and chronic medicated schizophrenic patients: a proton magnetic resonance spectroscopy study.

Involvement of the prefrontal cortex in schizophrenia has been implicated by neuropsychological, as well as neuropathological and imaging studies. Reductions of N-acetylaspartate (NAA), an in vivo marker of neuronal integrity, have repeatedly been detected in the frontal lobes of patients with schizophrenia by proton magnetic resonance spectroscopy (1H-MRS). In chronic medicated patients, a positive correlation between NAA levels of the prefrontal cortex and cognitive functioning has been observed, but to date, there have been no studies in first-episode neuroleptic-naive patients. In this study, single-voxel 1H-MRS was used to investigate neuronal function of the dorsolateral prefrontal cortex in 15 first-episode and 20 chronic schizophrenic patients. Outcomes were compared to 20 age-matched healthy controls to assess the relationship between prefrontal metabolism and neuropsychological performance. Patients with chronic schizophrenia had significant reductions of NAA, glutamate/glutamine, and choline levels compared to first-episode patients and healthy controls. Furthermore, creatine and phosphocreatine were significantly reduced in both patient groups compared to healthy controls. In the neuropsychological tests, chronic schizophrenic patients performed significantly poorer in the Auditory Verbal Learning Task (AVLT) compared to first-episode patients. In both patient groups, NAA levels of the left frontal lobe significantly correlated with performances in verbal learning and memory. These results corroborate data from recent structural and spectroscopic imaging studies of the frontal lobes in schizophrenia, in which cortical gray matter reductions after onset of symptoms as well as reduced levels of NAA in chronic, but not in first-episode schizophrenic patients have been reported.

Adult↗

Detection of colorectal polyps: comparison of multi-detector row CT and MR colonography in a colon phantom.

PURPOSE: To compare multi-detector row (four- and 16-section) computed tomography (CT), including a low-dose protocol, with high-field-strength (1.5- and 3.0-T) magnetic resonance (MR) imaging for reader detection of colorectal polyps in a colon phantom. MATERIALS AND METHODS: A colon phantom with simulated haustral folds and 10 polyps of varying size (2.0-8.0 mm) was imaged at four- and 16-section CT (section thicknesses of 1.25 and 0.75 mm, reconstruction increments of 0.8 and 0.7 mm, and 100 and 10 mAs, respectively, and 120 kV for both) and at 1.5- and 3.0-T MR imaging (three-dimensional gradient-recalled echo sequence, section thickness of 1.4 mm). Three-dimensional endoluminal images were assessed by 10 reviewers for each modality regarding polyp detection. Comparisons of sensitivities were performed by using logistic regression. RESULTS: Overall, polyps were detected with a sensitivity of 87% (95% confidence interval [CI]: 80%, 94%) at four-section CT, 92% (95% CI: 87%, 97%) at 16-section CT, 56% (95% CI: 46%, 66%) at 1.5-T MR imaging, and 55% (95% CI: 45%, 65%) at 3.0-T MR imaging. The detection of polyps at least 4 mm in diameter was not influenced by the modality or radiation dose (sensitivity of 100%). CT performed in low-dose mode depicted all polyps with a diameter of at least 3 mm. Polyps smaller than 3 mm in diameter were detected with a sensitivity of 7.5% (1.5-T MR imaging), 22.5% (3.0-T MR imaging), and 20% (low-dose CT); detection rates were significantly greater (P < .001) with normal-dose CT (four section, 67.5%; 16 section, 82.5%). Increased spatial resolution (with CT) and higher field strength (with MR imaging) had no significant effect on polyp detection. CONCLUSION: With both multi-detector row CT and MR imaging, readers detected polyps above the clinically relevant threshold diameter of 6 mm, with similar sensitivities.

Colonic Polyps↗

CT angiography in acute stroke: does it provide additional information on occurrence of infarction and functional outcome after 3 months?

OBJECTIVE: To investigate whether acute phase intracranial CT angiography (CTA) independently predicts infarction and functional outcome in ischemic stroke. METHODS: Hundred and fifty-one consecutive patients with acute (<12 h) ischemic stroke who received intracranial CTA were investigated. Stroke severity on admission was determined using the National Institute of Health Stroke Scale (NIHSS). Reconstructed CTAs were investigated for relevant pathology. Follow-up imaging was performed 24-48 h after admission. Functional outcome was assessed after 3 months using the modified Rankin scale. Single factor and multiple logistic regression analyses were performed to predict infarction and dependency (modified Rankin scale > or = 3) on follow-up. RESULTS: Median NIHSS on admission was 10 (IQR 3-14). Out of the 151 patients, 61 (40%) had pathological CTA findings. Infarction was demonstrated in 60/61 patients (98%) with and in 67/90 patients (74%) without vessel pathology. Presence of infarction on follow-up imaging and dependency at 3 months were correlated with pathological CTA findings on admission in single factor analysis (each p < 0.001). After adjustment for age (> or =/<65 years), NIHSS (> or =/<10), sex, therapy, and time to presentation (> or =/<3 h), only NIHSS > or = 10 on admission was predictive of dependency at follow-up (p < 0.001). CONCLUSIONS: Pathological CTA findings in the acute phase of ischemic stroke do not independently predict a poor outcome at 3 months after acute stroke.

Acute Disease↗

Selective coronary artery plaque visualization and differentiation by contrast-enhanced inversion prepared MRI.

AIMS: We sought to evaluate the utility of contrast-enhanced coronary magnetic resonance imaging (CE-MRI) for selective visualization and non-invasive differentiation of atherosclerotic coronary plaque in humans. METHODS AND RESULTS: Nine patients with coronary artery disease (CAD) as confirmed by X-ray angiography and multidetector computed tomography (MDCT) were studied by T1-weighted black blood inversion recovery coronary MRI before (N-IR) and after administration of Gd-DTPA (CE-IR). Plaques were categorized as calcified, non-calcified, and mixed based on their Hounsfield number derived from MDCT. With MDCT, a total of 29 plaques were identified, including calcified (n=6), non-calcified (n=6), and mixed calcified/non-calcified (n=17). On N-IR MRI, 26 plaques (90%) were dark, whereas three plaques (two non-calcified and one mixed) appeared bright. On CE-MRI, 13/29 (45%) plaques, 11 of which were mixed, one non-calcified, and one calcified showed contrast uptake. All others remained dark. CONCLUSION: In this preliminary study, we demonstrate the potential utility of CE-IR MRI for selective plaque visualization and differentiation of plaque types. The observed contrast uptake may be associated with endothelial dysfunction, neovascularization, inflammation, and/or fibrosis.

Adult↗

Amygdala activation during masked presentation of emotional faces predicts conscious detection of threat-related faces.

It has been argued that critical functions of the human amygdala are to modulate the moment-to-moment vigilance level and to enhance the processing and the consolidation of memories of emotionally arousing material. In this functional magnetic resonance study, pictures of human faces bearing fearful, angry, and happy expressions were presented to nine healthy volunteers using a backward masking procedure based on neutral facial expression. Activation of the left and right amygdala in response to the masked fearful faces (compared to neutral faces) was significantly correlated with the number of fearful faces detected. In addition, right but not left amygdala activation in response to the masked angry faces was significantly related to the number of angry faces detected. The present findings underscore the role of the amygdala in the detection and consolidation of memory for marginally perceptible threatening facial expression.

Adult↗

Idiopathic spinal cord herniation causing progressive Brown-Séquard syndrome.

We report a 59-year-old woman with a 2.5 year history of progressive loss of temperature sensation and dysesthesia in the right and weakness in the contralateral lower limb. Magnetic resonance imaging (MRI) and computed tomography myelography of the spinal cord demonstrated transdural herniation and deformation of the spinal cord in the upper thoracic spine. The herniated part of the spinal cord was untethered and replaced, and the anterior dural defect was closed. At a clinical follow-up 3 months later, the motor and sensory functions were almost restored. MRI at this time showed disentanglement of spinal cord adherence.

Brown-Sequard Syndrome↗

fMRI studies of sensitivity and habituation effects within the auditory cortex at 1.5 T and 3 T.

PURPOSE: To assess habituation effects in relation to field strength by fMRI at 1.5 vs. 3.0 T within the auditory cortex of healthy subjects. MATERIALS AND METHODS: fMRI experiments were performed on 19 healthy subjects at 1.5 T (N = 12) and 3 T (N = 12). The auditory cortex was stimulated binaurally by digitally generated pulsed (nu = 5 Hz) 800 Hz sine tones with three alternating on and off periods. RESULTS: The mean activation after stimulation (4.4% +/- 1.2% (1.5 T) and 5.3% +/- 2.3% (3 T)) and number of activated pixels (96.7 +/- 49.8 (1.5 T) and 139.9 +/- 101 (3 T)) were higher at 3 T compared to 1.5 T; however, that difference did not reach statistical significance. A characteristic signal decay with repeated stimuli was revealed at both 1.5 and 3 T, and the response to the second and third stimulation blocks was significantly lower compared to the first. The habituation pattern was the same, independently of field strength and age. CONCLUSION: The mean activation and number of pixels were only modestly higher at 3 T, probably due to higher physiologic noise and higher local macroscopic susceptibility gradients within the temporal lobes at 3 T. Our data reveal that measured auditory habituation is independent of field strength, and data obtained at two different field strengths do not differ fundamentally in this context.

Acoustic Stimulation↗

64- Versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience.

OBJECTIVES: We sought to assess the visualization of different coronary artery stents and the delineation of in-stent stenoses using 64- and 16-slice multidector computed tomography (MDCT). MATERIALS AND METHODS: A total of 15 different coronary stents with a simulated in-stent stenosis were placed in a vascular phantom and scanned with a 16-slice and a 64-slice MDCT at orientations of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis. Visible lumen diameter and attenuation in the stented and the unstented segment of the phantom were measured. Three readers assessed stenosis delineation and visualization of the residual lumen using a 5-point scale. RESULTS: Artificial lumen narrowing (ALN) was significantly reduced with 64-slice CT compared with 16-slice CT. At an angle of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis, the ALN for 16-slice CT was 42.2%, 39.8%, and 44.0% using a slice-thickness of 1.0 mm and 40.9%, 40.4%, and 41.6% using a slice thickness of 0.75 mm, respectively. With 64-slice CT, the ALN was 39.1%, 37.3%, and 36.0% at the respective angles. The differences between attenuation values in the stented and unstented segment of the tube were significantly lower for 64-slice CT. Mean visibility scores were significantly higher for 64-slice CT. CONCLUSION: Use of the 64-slice CT results in superior visualization of the stent lumen and in-stent stenosis compared with 16-slice CT, especially when the stent is orientated parallel to the x-ray beam.

Coronary Angiography↗

Effect of field strengths on magnetic resonance angiography: comparison of an ultrasmall superparamagnetic iron oxide blood-pool contrast agent and gadopentetate dimeglumine in rabbits at 1.5 and 3.0 tesla.

OBJECTIVES: We sought to compare the intravascular enhancement of an ultrasmall superparamagnetic iron oxide (USPIO) blood-pool contrast agent to gadopentetate dimeglumine for contrast-enhanced magnetic resonance angiography (CE-MRA) at field strengths of 1.5 and 3.0 T in rabbits. MATERIALS AND METHODS: CE-MRA at 1.5 and 3.0 T was performed at several time points (50 seconds and 5, 10, 20, and 30 minutes) after the manual intravenous injection of 40 micromol Fe/kg body weight of an USPIO (SH U 555 C; Schering AG, Berlin, Germany) and 100 micromol/kg body weight gadopentetate dimeglumine (Magnevist; Schering AG, Berlin, Germany). MRA was performed with comparable acquisition parameters at both field strengths (Turbo-gradient sequence; 1.5 T: TR/TE/alpha: 5.5/1.7 milliseconds/40 degrees ; 3.0 T: TR/TE/alpha: 5.1/1.8 milliseconds/40 degrees ) on clinical imaging systems (both: Gyroscan Intera, Philips Medical Systems, Best, The Netherlands). At either field strength, 6 rabbits were studied with both contrast agents (n = 24 in total). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated from signal intensity measurements in the abdominal aorta. RESULTS: Compared with 1.5 T, the SNR and CNR of gadopentetate dimeglumine significantly increased at 3.0 T by a factor of 2.2 and 2.3, respectively (P or= 0.05). At both field strength and either time point, CNR and SNR of SH U 555 C were significantly higher compared with gadopentetate dimeglumine at 3.0 T (P <or= 0.01). CONCLUSIONS: SNR and CNR of gadopentetate dimeglumine significantly increased with increasing field strength. No SNR or CNR gain was observed for SH U 555 C. However, blood-pool MRA with SH U 555 C is feasible at 3.0 T. Compared with gadopentetate dimeglumine, SNR and CNR of SH U 555 C were significantly higher from 5 to 30 minutes at both field strengths (P <or= 0.01).

Animals↗

Spontaneous acute dissection of the internal carotid artery: high-resolution magnetic resonance imaging at 3.0 tesla with a dedicated surface coil.

PURPOSE: Magnetic Resonance Imaging (MRI) has become the method of choice in the evaluation of patients with suspected cervical artery dissection (CAD). However, reliable identification of acute CAD might be impaired by the limited spatial resolution of standard 1.5 T MRI. In this preliminary study, we implemented a multicontrast high-resolution noninvasive vessel wall imaging approach at 3.0 T in patients with spontaneous CAD. METHODS AND MATERIALS: Ten patients with CAD of the internal carotid artery (ICA) were included in the study. 3.0 T MRI (Gyroscan Intera, Philips) was acquired using a dedicated phased-array coil. MRI-protocol consisted of: (1) bright blood 3D inflow MRA (TR/TE/FA = 25 milliseconds/3.1 millisecond/16 degrees , 120 slices, reconstructed voxel size 0.3 x 0.3 x 0.8 mm); (2) black blood cardiac-gated water-selective T1w 3D spoiled GE (TR/TE/FA = 31 milliseconds/7.7 milliseconds/15 degrees , 36 slices, 0.3 x 0.3 x 1.0 mm); and (3) black blood cardiac triggered fat suppressed T2w TSE (TR/TE/ETL = 3 heart beats/44 milliseconds/7, 18 slices, 0.3 x 0.3 x 2 mm). Three observers in consensus performed image analysis. Special attention was paid to the integrity of the luminal and adventitial vessel boundary and the presence of a communicating intimal tear or flap. RESULTS: 3.0 T MRI provided excellent delineation of vessel lumen and vessel wall as a result of the nearly complete suppression of arterial blood signal. An intramural hematoma could be identified in all patients, confined between the luminal and adventitial vessel boundary. In no patient a communicating intimal tear could be identified. Clear distinction between intramural hematoma and thrombus was possible. CONCLUSION: High-resolution vessel wall imaging in patients with acute CAD is feasible. The increased signal-to-noise ratio at 3.0 T can be invested to obtain a higher spatial resolution, permitting depiction of intimal and adventitial vessel wall boundary and the intramural hematoma in the diseased vessel segment. The morphologic information that is gained is helpful in the understanding of the underlying pathomechanismen of CAD.

Adult↗

Electrocardiogram-independent image reconstruction in cardiac multidetector computed tomography using retrospective motion synchronization.

OBJECTIVE: We sought to evaluate an electrocardiogram (ECG)-independent image reconstruction technique for coronary computed tomography (CT)-angiography based on cardiac motion. MATERIALS AND METHODS: The raw data from 20 patients was reconstructed with both an ECG-gated algorithm and a motion-dependent algorithm that calculates the cardiac motion-function directly from the CT raw data using a center of mass technique. Images were reconstructed in 5% steps over the R-R interval and the cardiac motion-cycle. For both approaches multiplanar reformations were created and the set of images with the least motion artifacts was used for the evaluation. Motion artifacts affecting the ascending aorta, the left main coronary artery and the entire course of the LAD, LCX and RCA were scored using a 5-point scale. RESULTS: The mean optimal reconstruction window was at 60% of the R-R interval and 30% of the cardiac motion cycle. A total of 73 of 100 vascular regions showed no motion artifacts in ECG-gated images, with the motion-synchronized algorithm only 41 regions were free of motion artifacts. The mean motion-score was 1.4 (+/-0.6) and 2.4 (+/-1.2) respectively (P < 0.05). CONCLUSION: In the currently implemented form the motion-gated algorithm is inferior to ECG-gated image reconstruction but can be used in patients with an incomplete or corrupt ECG-signal.

Algorithms↗