PubMed Health⌕ Search

Biomedical subjects

Wang-Chou Sung

Publications and source records attributed to Wang-Chou Sung.

4 recordsLinked to original sources

Pharmacokinetic applications of capillary electrophoresis: a review on recent progress.

This article covers recent publications from 2003 to 2005 on the subject of pharmacokinetic applications of CE. Many analytical methods were validated and more importantly, they were shown to have sufficient sensitivities to access pharmacokinetic data on different models. Because of unique advantages, such as simplified sample preparation methods, small sample amount required, high separation power, and speedy analysis, CE-based assays were found to gain popularity not only as a second method but also as a major method for many pharmacokinetic studies.

Animals↗

Stable permanently hydrophilic protein-resistant thin-film coatings on poly(dimethylsiloxane) substrates by electrostatic self-assembly and chemical cross-linking.

Poly(dimethylsiloxane) (PDMS) is a biomaterial that presents serious surface instability characterized by hydrophobicity recovery. Permanently hydrophilic PDMS surfaces were created using electrostatic self-assembly of polyethyleneimine and poly(acrylic acid) on top of a hydrolyzed poly(styrene-alt-maleic anhydride) base layer adsorbed on PDMS. Cross-linking of the polyelectrolyte multilayers (PEMS) by carbodiimide coupling and covalent attachment of poly(ethylene glycol) (PEG) chains to the PEMS produced stable, hydrophilic, protein-resistant coatings, which resisted hydrophobicity recovery in air. Attenuated total reflection Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy revealed that the thin films had excellent chemical stability and resisted hydrophobicity recovery in air over 77 days of measurement. The spectra also showed a dense coverage for PEG dialdehyde and excellent resistance to protein adsorption from undiluted rat serum. Atomic force microscopy revealed dense coverage with PEG dialdehyde and PEG diamine. Contact angle measurements showed that all films were hydrophilic and that the PEG dialdehyde-topped thin film had a virtually constant contact angle (approximately 20 degrees ) over the five months of the study. Electrokinetic analysis of the coatings in microchannels always exposed to air also gave good protein separation and constant electroosmotic flow during the five months that the measurements were done. We expect that the stable, hydrophilic, protein-resistant thin-film coatings will be useful for many applications that require long-term surface stability.

Animals↗

Chip-based microfluidic devices coupled with electrospray ionization-mass spectrometry.

We present the current status of the development of microfluidic devices fabricated on different substrates for coupling with electrospray ionization-mass spectrometry (ESI-MS). Until now, much success has been gained in fabricating the ESI chips, which show better performances due to miniaturization when compared with traditional methods. Integration of multiple steps for sample preparation and ESI sample introduction, however, remains a great challenge. This review covers the main technical development of electrospray device that were published from 1997 to 2004. This article does not attempt to be exclusive. Instead, it focuses on the publications that illustrated the breath of the development and applications of microchip devices for MS-based analysis.

Electrophoresis, Microchip↗

Poly(dimethylsiloxane)-based microfluidic device with electrospray ionization-mass spectrometry interface for protein identification.

An easy method to fabricate poly(dimethylsiloxane) (PDMS)-based microfluidic chips for protein identification by tandem mass spectrometry is presented. This microchip has typical electrophoretic microchannels, a flow-through sampling inlet, and a sheathless nanoelectrospray ionization (ESI) interface. The surface of the microchannel was modified with 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) and the generated electroosmotic flow under acidic buffer condition used for the separation was found to be more stable compared to that generated by the microchannel without modification. The feasibility of the device for flow-through sampling, separation, and ESI-MS/MS analysis was demonstrated by the analysis of a standard mixture composed of three tryptic peptides. Results show that four peaks corresponding to three peptide standards and acetylated products of the standard peptide were well resolved and the deduced sequences were consistent with those expected. Furthermore, the compatibility of this device with other miniaturized devices to integrate the whole process was also explored by connecting a miniaturized enzymatic digestion cartridge and a desalting cartridge in series to the sampling inlet of the microchip for the identification of a model protein, beta-casein.

Amino Acid Sequence↗