PubMed Health⌕ Search

Biomedical subjects

Warren Macdonald

Publications and source records attributed to Warren Macdonald.

5 recordsLinked to original sources

Stepwise introduction of a bone-conserving osseointegrated hip arthroplasty using RSA and a randomized study: I. Preliminary investigations--52 patients followed for 3 years.

BACKGROUND: We developed a total hip system using osseointegration guidelines, a metaphyseal-loading proximal femoral replacement in the retained neck and a dual-geometry titanium shell in the acetabulum. PATIENTS AND METHODS: A randomized controlled clinical trial was undertaken in 52 patients (53 hips), using the cemented Spectron stem and cementless Harris-Galante II cup as control implants (24 patients in experimental group, 29 control patients). Clinical measures of Harris Hip Score (HHS), pain score and radiostereometric analysis (RSA) at regular intervals for up to three years were used to monitor progress. RESULTS: No statistically significant differences were found in HHS and pain score; the stability of the cementless experimental implant was also comparable to that of the cemented controls by RSA. 3 revisions were required for migration in the experimental group and 1 was required for component dislocation in the control group. INTERPRETATION: Our findings indicate the practicality of osseointegration of titanium implants, but suggest that current performance is inadequate for clinical introduction. However, the stable fixation achieved in the retained neck in the majority of patients is indicative of osseointegration. This finding will encourage technical and design improvements for enhancement of clinical osseointegration and should also encourage further study. Periprosthetic osteolysis might be avoided by the establishment and maintenance of direct implant-bone connection: "osseointegration".

Acetabulum↗

Stepwise introduction of a bone-conserving osseointegrated hip arthroplasty using RSA and a randomized study: II. Clinical proof of concept--40 patients followed for 2 years.

BACKGROUND: We have developed a bone-conserving commercially pure titanium hip replacement system using osseointegration principles: a metaphyseal loading proximal femoral component affixing into the retained neck and metaphysis only, leaving the femoral canal untouched. The acetabular cup closely fits a dual-geometry cavity, avoiding stress protection at the dome. PATIENTS AND METHODS: After extensive laboratory and clinical pilot trial investigations, the surface-engineered implants were submitted to a prospective randomized controlled clinical trial involving 40 patients (40 hips), in which they were compared to the cemented Spectron femoral component and cementless Trilogy cup as control implant. The following clinical measures were used to monitor progress at regular intervals for the first 2 postoperative years: radiostereometric analysis (RSA), Harris Hip Score, pain score, WOMAC, and SF-36. RESULTS: After 2 years of follow-up, no statistically significant differences were seen between the groups concerning rotation or translation along the cardinal axes. The patients receiving the Gothenburg osseointegrated titanium (GOT) system had significantly higher Harris Hip Score at 6 months, suggesting more rapid recovery. WOMAC, SF-36 and pain analysis were similar for the first 2 postoperative years. INTERPRETATION: Our RSA data suggest that osseointegration was achieved for all patients receiving the GOT hip system. This bone-conserving prosthesis may provide a good alternative, especially for young and active patients.

Acetabulum↗

Variation in surface texture measurements.

Surface texture influences cellular response to implants, implant wear, and fixation, yet measurement and reporting of surface texture can be confusing and ambiguous. Seven specimens of widely different surface textures were submitted to three internationally renowned laboratories for surface texture characterization. The specimens were from dental implants, orthopedic implants, and femoral heads. Areas to be measured were clearly marked; simplified instructions were supplied but specific measurement parameters were not requested. Techniques used included contact profilometry, two- and three-dimensional laser profilometry, and atomic force microscopy. Four to thirteen parameters were reported, 2D or 3D, including R(a) or S(a); only three were common to all centers. The results varied by as much as +/-300-1000%, depending on technique and surface type. Some surfaces were not measurable by some techniques. One dental implant surface was reported with R(a) of 0.17, 0.85, 1.9, and 4.4 microm. The CoCr femoral head ranged from an R(a) of 0.011 to 0.10 microm; the zirconia head from 0.006 to 0.05 microm. Similar variability was reported for the other parameters. Useful surface texture characterization requires reporting of all measurement parameters. Comparisons between studies may be compromised if differences in technique are not considered.

Dental Implants↗

Improved tibial cutting accuracy in knee arthroplasty.

Initial stability and development of long-term fixation for cementless tibial components at the knee both depend on the accuracy of fit between implanted components and prepared bone surfaces. Tibial surfaces prepared for total knee replacement with conventional saw-blades and guides were shown by Toksvig-Larsen to vary by over 2 mm, from a flat surface at the point of maximum variation, and all points varied with a standard deviation of up to 0.4 mm. Surface cutting errors are caused by flexion of the saw-blade and blade angulation from the ideal alignment, due to poor guidance or control by the saw-block or guide. Most conventional knee instrumentation relies on flat surface or slotted cutting blocks, constraining the moving saw-blade against one or two guide surfaces. Improved cutting action was achieved by constraining the saw from the pivot point of the blade, and controlling motion of this constraint with parallel action slides. Using this saw-guide and an improved saw-blade, tibial cuts were made in mock arthroplasty procedures on twenty four cadaveric tibiae in mortuo. Analysis of Variance and Tukey's HSD test showed that the improved saw technique yielded significantly better flatness (p < 0.03) and greatly improved roughness (p < 0.0005).

Adult↗

A novel liner locking mechanism enhances retention stability.

Acetabular liner retention of a novel design of liner locking was evaluated in static and cyclic endurance modes. The locking mechanism combines geometric form and accurate machining to give high conformity to the acetabular shell and minimise relative motion against the metal shell, minimising debris generation and escape or ingress. Using amended test liners with integral coupling, mean static pullout strength was determined to be 399+/-53 N and lever-out strength 28.03+/-2.8 N m. Cyclic loading of 5 N m for up to 10 million cycles caused no significant reduction in strength, no detectable fretting wear, and the sealing mechanism prevented particle access between the cup interior and the "effective joint space". The stability measured ensures secure and reliable in vivo retention of the liner, comparable with extant component designs using other liner locking mechanisms.

Compressive Strength↗