Application of comprehensive two-dimensional gas chromatography with nitrogen-selective detection for the analysis of fungicide residues in vegetable samples.

Comprehensive two-dimensional gas chromatography (GCxGC) with nitrogen-phosphorus detection (NPD) has been investigated for the separation and quantitation of fungicides in vegetable samples. The detector gas flows (H(2), N(2) and air) were adjusted to achieve maximum response of signal whilst minimizing peak width. The comparison of different column sets and selection of the temperature program were carried out with a mixture of nine N-containing standard fungicides, eight of which were chlorinated. The results from GCxGC-NPD and GCxGC with micro electron-capture detection (muECD) were compared. External calibrations of fungicides were performed over a concentration range from 1 to 1,000 microgL(-1). The peak area calibration curves generally had regression coefficients of R(2)>0.9980, however for iprodione which was observed to undergo on-column degradation, an R(2) of 0.990 was found. The limit of detection (LOD) and limit of quantitation (LOQ) were less than about 74 and 246 ng L(-1), respectively. The intra-day and inter-day RSD values were measured for solutions of concentration 0.100, 0.500 and 1.50 mg L(-1). For the 0.500 mg L(-1) solution, intra- and inter-day precision of peak area and peak height for most of the pesticides were about 2% and 8%, respectively. Excellent linearity was observed for these standards, from 0.001 to 25.00 mg L(-1). The standard mixture peak positions were identified by using GCxGC with quadrupole mass spectrometry (qMS). To illustrate the potential and the versatility of both GCxGC-NPD and GCxGC-muECD, the method was applied to determination of fungicides in a vegetable extract. Decomposition of one fungicide standard (iprodione) during chromatography elution was readily observed in the two-dimensional (2D) GCxGC plot as a diagonal ridge response in the 2D chromatogram between the degrading compound and the decomposition product.

Aminoimidazole Carboxamide↗

Modulation ratio in comprehensive two-dimensional gas chromatography.

Comprehensive two-dimensional chromatography employs a serially coupled two-column arrangement where effluent from the first column is collected or sampled and then introduced to the second column according to a chosen modulation period. This is effected by use of a modulator at or near the column junction. One of the considerations in applying the technique is the period of the modulator, which determines the sampling duration of the first column effluent. Here, we propose that the sampling rate can be most effectively described by a new term, called the modulation ratio (MR). This is defined as the ratio of 4 times the first column peak standard deviation (4sigma) divided by the modulation period (PM) or 1.6985 times the half-height width of the peak (wh): MR = 4sigma/PM = wb/PM = (wh x 1.6985)/PM. The 4sigma value is more commonly recognized as the peak base width (wb). The use of 4sigma as the numerator is preferred to simply sigma because when the PM value used for an experiment is equal to sigma, then the MR value is calculated to be 4, implying that the primary peak will be modulated approximately 4 times as is normally recommended for a comprehensive multidimensional separation. The less well-defined term of modulation number (NM) has been previously used and proposed as the number of modulations per peak and, therefore, is intended to convey the manner in which the primary column peak is sampled; this is a subjective and not well-characterized value. The use of MR should provide users with a meaningful and strictly defined value when reporting experimental conditions. The utility of MR is demonstrated through a mathematical model of the modulation process for both Gaussian and tailing peaks, supported by an experimental study of the modulation ratio. It is shown that for the analysis of trace compounds where precise quantitative measurements are being made, the experiment should be conducted with an MR of at least 3. Conversely, for semiquantitative methods or the analysis of major components, an MR of approximately 1.5 should suffice.

Journal Article↗

Detector technologies for comprehensive two-dimensional gas chromatography.

The detector is an integral and important part of any chromatographic system. The chromatographic peak profiles (i.e. peak separation) should, ideally, be unaffected by the detector--it should only provide the sensing capacity required at the end of a column separation process. The relatively new technique of comprehensive 2-D GC (GC x GC) extends the performance of GC manyfold, but comes at a price--existing GC systems may not be adequately designed with the requirements of GC x GC in mind. This is primarily the need for precise measurement of very fast peaks entering the detector (e.g. as fast as 50 ms basewidth in some instances). The capacity of the detector to closely track a rapidly changing chromatographic peak profile depends on a number of factors, such as design of flow paths and make-up gas introduction, type of detector response mechanism, and the chemistry of the response. These factors are discussed here as a means to appreciate the technical demands of detection in GC x GC. The MS detector will not be included in this review.

Chromatography, Gas↗