PubMed Health⌕ Search

Biomedical subjects

Wei Zhan

Publications and source records attributed to Wei Zhan.

9 recordsLinked to original sources

Electrogenerated chemiluminescence. 83. Immunoassay of human C-reactive protein by using Ru(bpy)3(2+)-encapsulated liposomes as labels.

Liposomes ( approximately 100-nm diameter) containing Ru(bpy)32+ (bpy = 2,2'-bipyridine) were prepared as an electrogenerated chemiluminescent (ECL) tag for a sandwich-type immunoassay of human C-reactive protein (CRP). Polyclonal human CRP antibodies were introduced onto liposomes and magnetic beads through biotin-streptavidin interaction. The antigen-antibody conjugates formed on addition of a CRP-containing sample were separated from unreacted species magnetically. Addition of 0.1 M tri-n-propylamine and 0.1 M phosphate buffer (pH 7.6) containing 0.1 M NaCl and 1% (v/v) Triton X-100 caused liberation of the Ru(bpy)32+ from the liposome. ECL obtained in this medium showed a detection limit of 100 ng/mL for human CRP with good linearity of ECL intensity versus antigen concentration over the range 100 ng/mL-10 microg/mL.

2,2'-Dipyridyl↗

Chemically imaging living cells by scanning electrochemical microscopy.

Scanning electrochemical microscopy (SECM) is useful in probing and characterizing interfaces at high resolution. In this paper, the general principles of this technique are described and several applications of SECM to biological systems, particularly to living cells, is discussed, along with several example systems. Thiodione was detected and monitored electrochemically during the treatment of hepatocytes with cytotoxic menadione. The antimicrobial effects of silver(I) was followed by SECM through bacterial respiration. Living HeLa cells were shown to accumulate ferrocencemethanol (FcMeOH) and generated positive feedback for FcMeOH oxidation that can be further used to monitor the cell viability. Finally, individual giant liposomes, as cell models, with encapsulated redox compounds were successfully probed by SECM. In general SECM has the advantage of very high spatial resolution and versatility, especially for the detection of electroactive substances.

Biosensing Techniques↗

Scanning electrochemical microscopy. 56. Probing outside and inside single giant liposomes containing Ru(bpy)32+.

Giant liposomes containing Ru(bpy)(3)(2+) (bpy = 2,2'-bipyridine) were prepared as model systems for biomembranes and cells and studied by scanning electrochemical microscopy (SECM). Conical carbon fiber tips of submicrometer size were used to approach, image, and puncture individual liposomes immobilized on glass substrates. SECM images of the liposomes were obtained, and the leakage of Ru(bpy)(3)(2+) through the lipid membrane was probed. The tip was also pushed into liposomes and characteristic breakthrough transients, corresponding to liposomes with different compartmental configurations, were obtained. Voltammograms were obtained with the tip inside a single liposome after breaking through the membrane, and the influx of mediator and efflux of encapsulant after puncture could be observed.

2,2'-Dipyridyl↗

Microelectrochemical logic circuits.

We report microelectrochemical devices that mimic some functions of solid-state circuit components such as diodes and transistors. The operation of this new family of devices is enabled by a network of microfluidic electrochemical cells that communicate with one-another via conductive solutions and, in some cases, bipolar electrodes. The output of the devices can be either electrochemical or optical. The approach reported here is a first step toward the development of large-scale integrated electrochemical systems having parallel processing capabilities.

Journal Article↗

A multichannel microfluidic sensor that detects anodic redox reactions indirectly using anodic electrogenerated chemiluminescence.

Here, we describe a new approach for detecting redoxactive targets by electrochemical oxidation and reporting their presence by electrogenerated chemiluminescence (ECL) based on electrochemical oxidation of Ru(bpy)3(2+) (bpy = 2,2'-bipyridine) and tripropylamine (TPA). This new strategy, which complements our previous reports of using ECL to signal the presence of targets undergoing electrochemical reduction, takes advantage of many of the attractive attributes of microfluidic-based electrochemical cells. These attributes include close proximity of multiple flow channels and electrodes, ability to move reagents through channels under laminar flow conditions, and the capacity to precisely place device components relative to one another using photolithography. Specifically, the microfluidic electrochemical sensor described here consists of three channels. The analyte and ECL reporting cocktail flow through separate channels, but they share a common anode. The cathode resides in a channel containing a sacrificial reductant. In this configuration, the target analyte competes with Ru(bpy)3(2+) and TPA to provide electrons for the reductant. Accordingly, in this competitive assay approach, the presence of the analyte is signaled as a lowering of the ECL intensity. In this report, the device performance characteristics are reported, and the detection of both ferrocyanide and dopamine is demonstrated at micromolar concentrations.

Journal Article↗

A two-channel microfluidic sensor that uses anodic electrogenerated chemiluminescence as a photonic reporter of cathodic redox reactions.

This paper describes a new approach for sensing electrochemically active substrates in microfluidic systems. This two-electrode sensor relies on electrochemical detection at one electrode and electrogenerated chemiluminescent (ECL) reporting at the other. Each microfabricated indium tin oxide electrode is located in a separate microfluidic channel, but the channels are connected downstream of the electrodes to maintain a complete electrical circuit. Because of laminar flow, there is no bulk mixing of the fluids in the detecting and reporting channels. This approach allows the ECL reaction to be physically and chemically decoupled from the sensing channel of the device, which greatly expands the number of analytes that can be detected. However, because the cathode and anode are connected, electron-transfer processes occurring at the sensing electrode are electrically coupled to the ECL reaction. Charge balance permits the ECL light output to be quantitatively correlated to electrochemical reductions at the cathode. The system is used to detect Fe(CN)6(3-), Ru(NH3)6(3+), and benzyl viologen and report their presence via Ru(bpy)3(2+) (bpy = bipyridine) luminescence. Each different redox target initiates ECL at a unique potential bias related to its standard redox potential. The influence of the concentrations of Ru(bpy)3(2+) and the target analytes is discussed.

Journal Article↗

Electrochemical sensing in microfluidic systems using electrogenerated chemiluminescence as a photonic reporter of redox reactions.

This paper describes a microfluidics-based sensing system that relies on electrochemical detection and electrogenerated chemiluminescent (ECL) reporting. The important result is that the ECL reporting reaction is chemically decoupled from the electrochemical sensing reaction. That is, the electrochemical sensing reaction does not participate directly in the ECL process, but because electrochemical cells require charge balance, the sensing and ECL reactions are electrically coupled. This provides a convenient and sensitive means for direct photonic readout of electrochemical reactions that do not directly participate in an ECL reaction and thus broadens the spectrum of redox compounds that can be detected by ECL. The approach can be implemented in either a two-electrode or bipolar (single-electrode) configuration. By manipulating the placement and dimensions of the conductors, the photonic response can be enhanced. The system is used to electrochemically detect benzyl viologen present in solution and report its presence via Ru(bpy)(3)(2+) (bpy = 2,2'-bipyridine) luminescence.

Journal Article↗

Hydrogel-based microreactors as a functional component of microfluidic systems.

A simple two-step method for fabricating poly(ethylene glycol) (PEG) hydrogel-based microreactors and microsensors within microfluidic channels is described. The intrachannel micropatches contain either a dye, which can report the pH of a solution within a fluidic channel, or enzymes that are able to selectively catalyze specific reactions. Analytes present within the microfluidic channel are able to diffuse into the micropatches, encounter the enzymes, and undergo conversion to products, and then the products interact with the coencapsulated dye to signal the presence of the original substrate. The micropatches are prepared by photopolymerizing the PEG precursor within the channel of a microfluidic system consisting of a poly(dimethylsiloxane) mold and a glass plate. Exposure takes place through a slit mask oriented perpendicular to the channel, so the size of the resulting micropatch is defined by the channel dimensions and the width of the slit mask. Following polymerization, the mold is removed, leaving behind the micropatch(es) atop the glass substrate. The final microfluidic device is assembled by irreversibly binding the hydrogel-patterned glass slide to a second PDMS mold that contains a larger channel. Multiple micropatches containing the same or different enzymes can be fabricated within a single channel. The viability of this approach is demonstrated by sensing glucose using micropatches copolymerized with glucose oxidase, horseradish peroxidase, and a pH-sensitive dye.

Journal Article↗

Fabrication of microchambers defined by photopolymerized hydrogels and weirs within microfluidic systems: application to DNA hybridization.

This paper describes fabrication of serial microchamber arrays within the channels of a microfluidic device. The chambers are defined using a combination of weirs and UV-cross-linked hydrogel plugs (poly(ethylene glycol) diacrylates). This approach permits the microchambers to be addressed by pump-driven pressure in one dimension and by electrophoresis in the other. The function of the device is demonstrated by detecting DNA targets. Single-strand DNA (ssDNA) probes labeled with biotin were immobilized onto microbeads coated with streptavidin. The DNA-functionalized microbeads were packed into each of three microchambers by injection through inlet wells. Three oligonucleotides were designed as probes and four as targets. Hybridization reactions were performed by moving the targets across the array of probe-containing microchambers by electrophoresis. The hybridization of fluorescein-labeled ssDNA targets to complementary probes was observed by fluorescence microscopy. These studies resulted in four key observations: (1) there was no detectable binding of targets to noncomplementary probes; (2) hybridization was 90% complete within 1 min; (3) once captured, the targets could be independently released and recovered from the microbeads by treatment with 0.1 N NaOH; (4) multiple analyses could be performed using a single bead set, but there was degradation in performance after each capture/release cycle.

DNA, Single-Stranded↗