PubMed Health⌕ Search

Biomedical subjects

Wenqing Shui

Publications and source records attributed to Wenqing Shui.

7 recordsLinked to original sources

Nanopore-based proteolytic reactor for sensitive and comprehensive proteomic analyses.

Various silica-based microreactors have been designed that use enzyme immobilization to address technical concerns in proteolysis including inefficient and incomplete protein digestion. Most of current designs for proteolytic reactors can improve either protease stability or proteolysis efficiency of individual protein(s). However, the desired features such as rapid digestion, larger sequence coverage, and high sensitivity have not been achieved by a single microreactor design for broad range proteins with diverse physical properties. Here, unlike conventional enzyme immobilization strategies, we describe a novel proteolytic nanoreactor based on the unique three-dimensional nanopore structure of our newly synthesized mesoporous silica (MPS), FDU-12, which integrates substrate enrichment, "reagent-free" protein denaturation, and efficient proteolytic digestion. In our design, protein substrates were first captured by MPS nanopore structure and were concentrated from the solution. Following the pH change and applying trypsin, the denaturation and concurrent proteolysis of broad-range proteins were efficiently achieved. In minutes, many more sample peptides from the in-nanopore digestion of protein mixtures were detected by mass spectrometry, resulting in the identifications of a broad range of diverse proteins with high sequence coverage. The unique features of FDU-12 nanostructure that allow rapid, complete proteolysis and resulting enhanced sequence coverage of individual proteins were investigated by using Raman spectroscopy and comparative studies with respect to other MPSs.

Animals↗

Mesoporous silica nanoreactors for highly efficient proteolysis.

Protein digestion inside the nanoreactor channels of mesoporous silica (SBA-15) is reported, and evaluated by using peptide-mass mapping. Both proteases and substrates were efficiently captured within these biocompatible nanoreactors. After 10 minutes, the mass spectrum of the protein digests released from the mesoporous-silica-based nanoreactors revealed the presence of eight peptides covering 58% of the protein sequence with an intense signal (signal/noise ratio > 70). In comparison, the conventional overnight in-solution digestion of proteins under otherwise identical conditions generated only three peptides (27% sequence coverage). We propose that this order-of-magnitude increase in the proteolytic reaction rate is mainly attributed to two factors: substrate enrichment within mesoporous silica channels and enzyme immobilization. The surface properties and macrostructure of the mesoporous silica were studied to reveal their significant influence on proteolytic reactions.

Hydrolysis↗

Micro-electrospray with stainless steel emitters.

The physical processes underlying micro-electrospray (micro-ES) performance were investigated using a stainless steel (SS) emitter with a blunt tip. Sheathless micro-ES could be generated at a blunt SS tip without any tapering or sanding if ESI conditions were optimized. The Taylor cone was found to shrink around the inner diameter of the SS tubing, which permitted a low flow rate of 150 nL/min for sheathless microspray on the blunt tip (100 microm i.d. x 400 microm o.d.). It is believed that the wettability and/or hydrophobicity of SS tips are responsible for their micro-ES performance. The outlet orifice was further nipped to reduce the size of the spray cone and limit the flow rate to 50-150 nL/min, resulting in peptide detection down to attomole quantities consumed per spectrum. The SS emitter was also integrated into a polymethylmethacrylate microchip and demonstrated satisfactory performance in the analysis and identification of a myoglobin digest.

Gramicidin↗

High accuracy mass measurement of peptides with internal calibration using a dual electrospray ionization sprayer system for protein identification.

A dual-ESI-sprayer system was constructed and applied to achieve high accuracy of peptide mass measurement for protein identification by means of peptide mapping. Sample was introduced in one sprayer, and reference in the other, thus making internal calibration possible greatly enhancing the mass accuracy. Several samples were utilized to evaluate the reliability of this dual-ESI-sprayer system. The range of mass errors was 0.16-5.37 ppm. The peptide masses of tryptic digests of myoglobin (horse) were measured by the HPLC/dual-ESI-MS system, with mass deviations ranging from 0.01-7.67 ppm, and about 75% mass deviations below 5 ppm with 40% below 1[?]ppm. These peptide masses were utilized to perform database searching for protein identification, and compared to results obtained by external calibration. This comparison showed that the internal calibration provides a more reliable method of protein identification, with a much smaller number of required peptides for matching, and with less CPU time consumed for database searching.

Animals↗

Naturally and externally pulsed electrospray.

The current studies on pulsation phenomena in electrospray ionization, and pulsed electrospray ionization (ESI) under external electrical control are reviewed. A number of investigations have shown that two types of pulsation processes exist: low-frequency fluctuation and high-frequency droplet-formation. The low-frequency pulsation is induced by an imbalance between the flow rate of the input sample to the Taylor cone and the feed rate of the output solution to the liquid filament. The high-frequency pulsation mainly results from the initial droplet formation process, and is modulated by the low-frequency pulsation. The fundamental and experimental sections of these two pulsations are discussed. Experimental results also show that low and high pulsations can both be controlled electrically to create a pulsed ESI so that high sensitivity and an enhanced S/N ratio can be achieved. However, the co-ordination of the synchronization between a natural pulsation and a pulsed ESI, as well as its application to mass spectrometer (MS) analysis, demands further research.

Journal Article↗

Enhancing TOF/TOF-based de novo sequencing capability for high throughput protein identification with amino acid-coded mass tagging.

Because of the intrinsic physical properties of single- or double-charged ions, MALDI-based CID on these peptide precursor ions tends to be incomplete, resulting in a large number of MS/MS spectra unassigned or ambiguously identified. Consequently, the TOF/TOF high throughput capability may not be fully explored and utilized. Here, we describe a novel method for de novo sequence assignment of those MALDI TOF/TOF MS/MS spectra with incomplete or weak fragment ion series. In this approach, the deuterium-labeled lysine and leucine precursors were used in parallel to mass-tag the proteome of a metastatic human hepatocellular carcinoma (HCC) cell line during in vivo cell culturing. These stable isotope precursor markers not only position at terminal but at internal MS/MS fragment ions with the characteristic isotope pattern induced by multiple mass tagging in parallel. This enhanced signal specificity evidently resolved ambiguities in those sparse poor-quality TOF/TOF spectra by providing critical sequential links among MS/MS fragment ions. Our data-dependent approach was able to reduce many false-positives in current genome sequence-based peptide sequencing. With developing new algorithms accordingly, our approach is amenable for automation that will lead to more comprehensive and reliable identification for proteomes.

Carcinoma, Hepatocellular↗