PubMed Health⌕ Search

Biomedical subjects

Wenrui Jin

Publications and source records attributed to Wenrui Jin.

At least 19 recordsLinked to original sources

Characterization of prolidase activity using capillary electrophoresis with tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence detection and application to evaluate collagen degradation in diabetes mellitus.

A new method for prolidase (PLD, EC 3.4.13.9) activity assay was developed based on the determination of proline produced from enzymatic reaction through capillary electrophoresis (CE) with tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)3(2+)] electrochemiluminescence detection (ECL). A detection limit of 12.2 fmol (S/N = 3) for proline, corresponding to 1.22 x 10(-8) units of prolidase catalyzing for 1 min was achieved. PLD activity determined by CE-ECL method was in agreement with that obtained from the classical Chinard's one. CE-ECL showed its powerful resolving ability and selectivity as no sample pretreatment was needed and no interference existed. The clinical utility of this method was successfully demonstrated by its application to assay PLD activity in the serum of diabetic patients in order to evaluate collagen degradation in diabetes mellitus (DM). The results indicated that enhanced collagen degradation occurred in DM.

2,2'-Dipyridyl↗

High-throughput single-cell analysis for enzyme activity without cytolysis.

A novel high-throughput method without cytolysis for determination of enzyme activity inside single cells was developed by a combination of chemical cell perforation and an intracellular enzyme-catalyzed reaction. Peroxidase (PO) inside human neutrophils was chosen as the model system. Cells were perforated with digitonin to form micropores on the cell membrane. The perforated cells, with physiological buffer saline of pH 7.4 containing hydroquinone (H2Q) and H2O2, were continuously propelled by pressure through a capillary as the microsampler and microreactor. Small molecules H2Q and H2O2 could diffuse into the cell interior through the micropores on the cell membrane, and the large molecule PO remained in the cell interior. Intracellular PO converted H2Q into benzoquinone (BQ). BQ diffused out from the cell interior to the cell surface through the micropores and formed a BQ zone around the cell. The process proceeded in the capillary during cell movement. The BQ zones around every moving perforated cell were continuously delivered to the capillary outlet by hydraulic flow and detected. An average detection rate of >1 cell/min was obtained.

Catalysis↗

Measurement of enzyme activity in single cells by voltammetry using a microcell with a positionable dual electrode.

The electrochemical single-cell analysis for enzyme activity was developed using microcells on a microcell array coupled with a positionable dual microelectrode. The microcell array with the nanoliter-scale microcells was constructed using simple chemical etching without photolithographic techniques. The positionable dual microelectrodes consisted of the nanometer-to-micrometer-radius Au disk working electrode and a approximately 80-microm-radius Ag/AgCl reference electrode. Peroxidase was chosen as the model enzyme. Factors that concern electrochemical single-cell analysis in microcells such as solution evaporation, interference of soluble oxygen, electrode size, solution volume, and electrode fouling were investigated and discussed. The 20 or 100 nL of detection volume was found to be suitable for peroxidase determination in single neutrophils or single acute promyelocytic leukemia cells without interference from intracellular macromolecules and electrode fouling, when the dual electrode with a 10-microm-radius Au disk working electrode was used. Cells were perforated with digitonin before transferring them into the microcells, to lyse cells easily. The perforated cells were transferred into the microcells by pushing a microscope slide on a drop of the cell suspension on the microcell array. After a single cell in the microcell was lysed using a freeze-thawing technique and allowed to dry, physiological buffer saline containing 2.0 x 10(-3) mol/L hydroquinone and 2.0 x 10(-3) mol/L H2O2 as the substrates of the enzyme-catalyzed reaction was added. The microcell array was positioned in a constant-humidity chamber to prevent evaporation. Then the dual electrode was inserted into the microcell by means of a scanning electrochemical microscope and the product benzoquinone of the enzyme-catalyzed reaction was voltammetrically detected. Peroxidase activity could be quantified using the steady-state current on the voltammogram after subtracting the blank and using the calibration curve.

Biosensing Techniques↗

Kinetic study of paracetamol on prolidase activity in erythrocytes by capillary electrophoresis with Ru(bpy)(3) (2+) electrochemiluminescence detection.

We explored the CE with (bpy) (2+) (3) electrochemiluminescence detection for the kinetic study of drug-enzyme interaction. Effects of four nonsteroidal anti-inflammatory drugs including aspirin, paracetamol, sodium salicylate and phenacetin on prolidase (PLD) activity in erythrocytes were investigated. Aspirin enhanced PLD activity whereas the other three had inhibiting effects. This may reveal their different effects on the collagen biosynthesis and catabolism that influence tumor invasiveness. Kinetic study of paracetamol on PLD showed that the value of Michaelis constant K(m) for PLD was 1.23 mM. The mechanism of PLD inhibition by paracetamol is noncompetitive inhibition, and the inhibitor constant K(i) value obtained in our research was 9.73 x 10(3) microg/L.

Acetaminophen↗

Determination of lactate dehydrogenase isoenzymes in single rat glioma cells by capillary electrophoresis with electrochemical detection.

A method for determination of lactate dehydrogenase (LDH) isoenzymes in single rat glioma cells (C6) was developed. In this method, a whole cell was electrokinetically injected into the front end of the separation capillary. After that, the cell was lysed by ultrasonication and the isoenzymes in the cell were pre-separated at 20 kV for 5 min and then incubated for 2 min with the enzyme substrates nicotinamide adenine dinucleotide (NAD(+)) and lactate in the capillary electrophoresis running buffer. The electroactive product NADH generated by the isoenzymes through on-capillary enzyme-catalyzed reaction was detected at the outlet of capillary by using the end-capillary amperometric detection with a constant potential mode at a carbon fiber bundle microdisk electrode. Since the amplification of signal via the enzyme reaction, the concentration of nicotinamide adenine dinucleotide (NADH) is much higher than that of LDH. The external standardization was used to quantify isoenzymes in individual cells. Three LDH isoenzymes in single rat glioma cells (C6) were determined and quantified.

Animals↗

Single-cell analysis by intracellular immuno-reaction and capillary electrophoresis with laser-induced fluorescence detection.

A novel method for single-cell analysis was developed by combining electroporation for intracellular immuno-reaction and capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. Human interferon-gamma (IFN-gamma) in natural killer (NK) cells was chosen as the test antigen. Two forms of IFN-gamma in single cells could be well separated and detected with a limit of detection of zeptomole. In this assay, the anti-IFN-gamma monoclonal antibody labeled with fluorescein isothiocyanate (Ab*) was introduced into NK cells by electrophoration for intracellular immuno-reaction. After completion of the intracellular immuno-reaction, the NK cells were chemically pre-perforated with digitonin to lyse easily. Then, one NK cell containing the complexes of IFN-gamma isoantigens with Ab* was electrokinetically injected into the capillary. The cell adsorbed on the tip of capillary was lysed by ultrasonication. Finally, the complexes of the different forms of IFN-gamma in the cell were separated and detected by CE-LIF detection.

Electrophoresis, Capillary↗

Single-cell analysis by electrochemical detection with a microfluidic device.

A novel electrochemical method with a microfluidic device was developed for analysis of single cells. In this method, cell injection, loading and cell lysis, and electrokinetic transportation and detection of intracellular species were integrated in a microfluidic chip with a double-T injector coupled with an end-channel amperometric detector. A single cell was loaded at the double-T injector on the microfluidic chip by using electric field. Then, the docked cell was lysed by a direct current electric field strength of 220 V/cm. The analyte of interest inside the cell was electrokinetically transported to the detection end of separation channel and was electrochemically detected. External standardization was used to quantify the analyte of interest in individual cells. Ascorbic acid (AA) in single wheat callus cells was chosen as the model compound. AA could be directly detected at a carbon fiber disk bundle electrode. The selectivity of electrochemical detection made the electropherogram simple. The technique described here could, in principle, be applied to a variety of electroactive species within single cells.

Ascorbic Acid↗

Analysis of amino acids in individual human erythrocytes by capillary electrophoresis with electroporation for intracellular derivatization and laser-induced fluorescence detection.

A method for monitoring amino acids in single erythrocytes is described. For intracellular derivatization, reagent fluorescein isothiocyanate (FITC) was introduced into living cells by electroporation. For an 8 microm erythrocyte, the analytes were diluted by a factor of only 1.6. After completion of the derivatization reaction, a single cell was injected into the separation capillary tip and lysed there. The derivatized amino acids were separated by capillary electrophoresis, followed by laser-induced fluorescence detection. Nine amino acids were quantitatively determined, with amounts of amino acids ranging from 3.8-32 amol/single cell.

Amino Acids↗

Determination of different forms of human interferon-gamma in single natural killer cells by capillary electrophoresis with on-capillary immunoreaction and laser-induced fluorescence detection.

A novel method for determining different forms of human interferon-gamma (IFN-gamma) in single natural killer cells was developed by capillary electrophoresis (CE) with on-capillary immunoreaction and laser-induced fluorescence (LIF) detection. Cells were perforated with digitonin and one single cell was electrokinatically introduced into the front end of a separation capillary. The monoclonal antibody labeled with fluorescein isothiocyanate of IFN-gamma was hydrodynamically injected into the front end of the capillary around the cell introduced. After the cell was lysed by ultrasonication, the front end of the capillary was used as a microreactor to allow different forms of IFN-gamma to process the immunoreaction with their labeled antibody. Finally, the complexes of different forms of IFN-gamma with their labeled antibody were separated and detected by CE with LIF detection with a limit of detection of zeptomoles (10(-21) mol).

Cell Extracts↗

Measurement of alkaline phosphatase isoenzymes in individual mouse bone marrow fibroblast cells based on capillary electrophoresis with on-capillary enzyme-catalyzed reaction and electrochemical detection.

A novel method for the determination of alkaline phosphatase (ALP) isoenzymes in individual fibroblast cells of mouse bone marrow was developed by combining capillary electrophoresis with an on-capillary enzyme-catalyzed reaction and electrochemical detection. In this method, a single an cell, followed by 5.0 x 10(-2) mol/L Na2B4O7- 3.0 x 10(-2) mol/L NaCl (pH 9.8) as cell lysis solution, was injected into the inlet of the separation capillary by electromigration. The cell was lysed by applying a voltage of 2 kV. The ALP isoenzymes in the cell were preseparated at 20 kV for 1 min, and then allowed to react for 30 min with disodium phenyl phosphate as enzyme substrate in the running buffer. ALP converted disodium phenyl phosphate into its product, phenol, at a relatively high reaction rate without consumption, with resultant amplification of the signal on prolonged reaction time, producing an adequate amount of product for final detection. A mass detection limit as low as 3.5 x 10(-21) mol/L (corresponding to 1.5 nU) was achieved. Finally, the two zones of products generated by ALP isoenzymes were detected at the outlet of the capillary by using the end-capillary amperometric detection at a carbon fiber microdisk bundle electrode with a constant potential.

Alkaline Phosphatase↗

Determination of lactate dehydrogenase in human erythrocytes by capillary electrophoresis with electrochemical detection.

Capillary electrophoresis (CE) was employed to analyze lactate dehydrogenase (LDH) in human erythrocytes using an amperometric detector with a carbon fiber micro-disk bundle electrode. LDH activity was measured by determining the amount of NADH generated by LDH through a enzyme-catalyzed reaction between NAD(+) and lithium lactate. The factors influencing the enzyme-catalyzed reaction, separation and detection were examined and optimized. The following conditions were suitable for the determination of LDH: running buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 7.5); separation voltage, 20.0 kV; detection potential, 1.00 V (versus saturated calomel electrode (SCE)). The conditions of enzyme-catalyzed reaction were: reaction buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 9.3); substrates, 5.0 x 10(-2)mol/l lithium lactate and 5.0 x 10(-3)mol/l NAD(+); reaction time, 10 min. The concentration limit of detection (LOD) of the method was 0.017 U/ml at a signal-to-noise (S/N) ratio of 3, which corresponded to 1.10 x 10(-10)mol/l, and the mass LOD was 2 x 10(-20)mol. The linear dynamic range was 0.039-4.65 U/ml for the injection voltage of 5.0 kV and injection time of 10s. The relative standard deviation (R.S.D.) was 0.85% for the migration time and 1.8% for the electrophoretic peak area. The method was applied to determine LDH in human erythrocytes. The recovery of the method was between 98 and 101%.

Electrochemistry↗

Catalysis-electrochemical determination of zeptomole enzyme and its application for single-cell analysis.

A novel electrochemical method for determination of zeptomole amounts of enzyme was developed by a combination of on-capillary enzyme-catalyzed reaction and electrochemical detection. A limit of detection (LOD) of zeptomole (zmol, 10(-)(21) mol) was achieved by monitoring the product of the enzyme-catalyzed reaction. In this method, after enzyme molecules were electrokinetically injected into the capillary, they were electromigrated to the section of the capillary immersed in a warm water bath, where the enzyme molecules reacted with the enzyme substrates in the running buffer in the presence of the activator of the enzyme-catalyzed reaction. Then the electroactive product zone of the enzyme-catalyzed reaction was electromigrated to the horn-shaped outlet of the capillary and electrochemically detected by a carbon fiber disk bundle electrode at a constant potential. Glucose-6-phosphate dehydrogenase (G6PDH) was chosen as the model enzyme. A LOD of 1.3 zmol was achieved. This method was applied to determine zeptomoles of G6PDH in individual human erythrocytes.

Catalysis↗

Simultaneous determination of tryptophan and glutathione in individual rat hepatocytes by capillary zone electrophoresis with electrochemical detection at a carbon fiber bundle--Au/Hg dual electrode.

A method for single-cell analysis was developed by combining capillary zone electrophoresis (CZE) with electrochemical detection (ECD) using a dual electrode consisting of two different types of electrode material (carbon fiber and Au/Hg). In this method, the parallel mode was used. Different potentials were applied to both electrodes of the dual electrode. Tryptophan and glutathione, which could not be simultaneously detected by normal CZE-ECD, could be simultaneously and selectively detected by CZE-ECD at the dual electrode in one run, respectively. The CZE-ECD system with the dual electrode was applied to determine them in individual rat hepatocytes.

Animals↗

Amperometric detection of perphenazine at a carbon fiber micro-disk bundle electrode by capillary zone electrophoresis.

A simple method for determination of perphenazine by capillary zone electrophoresis with amperometric detection is described. The optimum conditions of separation and detection are 1.50 x 10(-3) mol/l Na(2)B(4)O(7)-1.0 x 10(-3) mol/l NaOH (pH 9.9) for the buffer solution, 18 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, and 0.80 V versus saturated calomel electrode for the detection potential, respectively. The limit of detection is 5.0 x 10(-8) mol/l or 44 amol (S/N=3). The linear range of the calibration curve is 1.00 x 10(-7) to 1.00 x 10(-4) mol/l. The relative standard deviation is 1.5% for the migration time and 2.9% for the electrophoretic current at peak maximum. The method is applied to the determination of perphenazine in human urine.

Antipsychotic Agents↗

Determination of glutathione in single human hepatocarcinoma cells by capillary electrophoresis with electrochemical detection.

A method for determination of glutathione (GSH) in single human hepatocarcinoma (HH) cells was described by capillary zone electrophoresis with electrochemical detection at a gold/mercury amalgam micro-disk electrode. When HH cells were washed with the running buffer instead of physiological buffer saline, only one electrophoretic peak for GSH is depicted on the electropherograms of single HH cells. When electroosmotic injection of 0.01 mol/l NaOH for lysing the cell introduced into the capillary, the lysis time can be shorten to 5 s. The whole cell injection and no need of derivatization reaction lead more accurate and precise results. The average amount of GSH in an individual HH cell is 22.3+/-5.8 fmol (mean+/-standard deviation), which is consistent with that of its homogenate.

Carcinoma, Hepatocellular↗

Capillary electrophoretic enzyme immunoassay with electrochemical detection using a noncompetitive format.

A capillary electrophoretic enzyme immunoassay with electrochemical detection (CE-EIA-ED) using a noncompetitive format has been developed. In this method, antigen (Ag) reacts with an excess amount of horseradish peroxidase (HRP)-labeled antibody (Ab*). The free Ab* and the bound Ag-Ab* complex produced in the solution are separated by capillary zone electrophoresis in a separation capillary. Then they catalyze enzyme substrate 3,3',5,5'-tetramethylbenzide (TMB(Red)) and H(2)O(2) in a reaction capillary following the separation capillary. The reaction product, TMB(Ox), can be determined using amperometric detection on a carbon fiber microdisk bundle electrode at the outlet of the reaction capillary. Due to the amplification of the enzyme, a significant amount of TMB(Ox) can be produced for detection. Therefore, the limit of detection (LOD) of CE-EIA-ED is very low. A tumor marker (CA15-3) was used as a model, in order to test the method. The concentration LOD of CA15-3 is 0.024 U/ml, which corresponds to a mass detection limit of 1.3x10(-7) U.

Electrochemistry↗

Capillary electrophoretic enzyme immunoassay with electrochemical detection for thyroxine.

A capillary electrophoretic enzyme immunoassay with electrochemical detection (CE-EIA-ED) has been developed. In this method, antigen (Ag) competes with horseradish peroxidase (HRP)-labeled antigen (HRP-Ag) for a limited number of antibody (Ab) binding sites. The free HRP-Ag and the bound HRP-Ag-Ab complex are separated by capillary electrophoresis in a separation capillary. Then they catalyze the oxidation of their enzyme substrate 3,3',5,5'-tetramethylbenzide (TMB (reduced form)) with H(2)O(2) in a reaction capillary, which follows the separation capillary. The reaction product (TMB (oxidized form)) is amperometrically determined using a carbon fiber microdisk bundle electrode at the outlet of the reaction capillary. Due to the amplification of the enzyme, the concentration of TMB(Ox) is much higher than those of free HRP-Ag and the bound HRP-Ag-Ab complex. Therefore, the limit of detection (LOD) of CE-EIA-ED is very low. The method has been used to determine thyroxine in human serum. A concentration of LOD of 3.8 x 10(-9)mol/L, which corresponds to a mass LOD of 23.2 amol, was achieved.

Electrochemistry↗

Determination of midecamycin by capillary zone electrophoresis with electrochemical detection.

Capillary zone electrophoresis was employed for the determination of midecamycin using an end-column amperometric detection with a carbon fiber micro-disk bundle electrode at a constant potential of +1.15 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 1.00x10(-3) mol l(-1) Na(2)HPO(4)-3.49x10(-4) mol l(-1) NaOH (pH 11.4) for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The limit of detection is 5.0x10(-7) mol l(-1) or 0.41 fmol (S/N=3). The linear range of the calibration curve is 1.00x10(-6)-1.00x10(-3) mol l(-1). The relative standard deviation is 1.4% for the migration time and 4.9% for the electrophoretic peak current. The method could be applied to the determination of midecamycin in human urine. In this case, a separation voltage of 14 kV was used.

Electrophoresis, Capillary↗