PubMed Health⌕ Search

Biomedical subjects

Werner G Daniel

Publications and source records attributed to Werner G Daniel.

72 records · Page 4Linked to original sources

Practicability and limitations of enhanced external counterpulsation as an additional treatment for angina.

BACKGROUND: An increasing number of clinical studies indicates reduction of angina and myocardial ischemia by enhanced external counterpulsation (EECP) therapy. However, given the wide range of contraindications and the long duration of treatment, eligibility and practicality issues have not been addressed systematically. HYPOTHESIS: Of all candidates for EECP (patients with drug-refractory angina without possibility of revascularization), the majority either have contraindications or have practical problems complying with the time demands that this therapy imposes. In the rest, EECP leads to satisfactory results. METHODS: During 18 months, every consecutive patient with angina despite medical and interventional therapy was evaluated for EECP at one center. Treated patients underwent a bicycle exercise test and perfusion imaging before and after the standard course of 35 h of EECP. In addition, patients were asked about frequency of angina and nitroglycerin usage before and after EECP, and all patients filled out a final questionnaire 1 year after the end of therapy. RESULTS: Overall, 48 patients were considered candidates for EECP. Of these, 24 were excluded for medical reasons: poor ejection fraction (4), peripheral artery disease (4), anticoagulation (4), and atrial fibrillation (3). Eight further patients declined EECP for lack of time or accommodation. Another 3 of the 16 remaining patients dropped out because of side effects. In the 13 patients who finished the treatment course, weekly anginal episodes were reduced by 48% (p < 0.05), on-demand nitroglycerin puffs were reduced by 51% (p < 0.05), work capacity was improved by 22% (p < 0.05), and the number of reversible perfusion defects in perfusion scans decreased nonsignificantly (-28%). However, 4 of 13 treated patients determined 1 year later that the detriment of loss of time exceeded the benefits of EECP. CONCLUSION: Similar to previous reports, our study confirms the reduction of angina and improvement of work capacity after EECP. However, using established contraindications, approximately two-thirds of patients considered to be candidates had to be excluded, and one-third of the treated patients regarded EECP therapy retrospectively as too time consuming.

Angina Pectoris↗

Phenotypic overlap between monocytes and vascular endothelial cells.

During embryonic development, endothelial cells (ECs) develop organ specific properties. ECs express specific markers, which are helpful in identifying these cells in vivo and in culture. Interestingly, most of the supposed specific endothelial markers are present on both ECs and hematopoietic precursors or mature blood cells, which correspond to the idea of a common embryonic precursor. Monocytes/makrophages and monocyte-derived dendritic cells, as more differentiated hematopoietic cell populations, show a wide phenotypic overlap with particularly hepatic sinusoidal, and microvascular endothelial cells within inflamed tissue, such as neovascularizised complicated atherosclerotic plaques. Furthermore, under local angiogenic growth conditions monocytes or monocyte precursors or immature dendritic cells may differentiate into endothelial like cells. First evidence suggests an endothelium-independent revascularization potential carried by monocyte-derived macrophages. These macrophages have been shown to form tunnel-like structures in ischemic regions. Future studies have to address the question, whether monocyte-/dendritic cell-derived endothelial like cells can develop a similar functional behaviour in vasoregulation, coagulation and fibrinolysis, as described for vascular endothelial cells, and thus may contribute to neoangiogenesis by a direct vessel-forming role.

Animals↗

Patency rates of three arterial grafting patterns to the left anterior descending and diagonal coronary arteries in symptomatic patients.

BACKGROUND: The use of internal thoracic arteries is an established method for treating coronary artery disease because of their excellent long-term patency rates. However, these results mainly referred to the left internal thoracic artery (LITA) grafted to the left anterior descending coronary artery (LAD). The aim of this study was to compare the patency rate of the LITA after its placement to the diagonal branch. METHODS: A total of 302 patients (median age 65 years) with previous arterial revascularization were retrospectively enrolled in the study. We compared LITA grafts to the LAD with those to the diagonal branch and with sequential LITA grafts to both vessels with respect to the patency rate over a median follow-up of 39 months after prior operation. Angiography was performed for recurrent angina. RESULTS: The average occlusion/stenosis rate of saphenous vein and LITA grafts were 43.1% and 14.1%, respectively (p < 0.0001). Of the 302 patients, 248 had received a single LITA graft to the LAD; 21 patients, a single LITA graft to the diagonal branch; and 33 patients, a sequential LITA graft to both vessels. Thirty-three LITA grafts to the LAD (13.3%), three LITA grafts to the diagonal branch (14.3%), and six sequential LITA grafts to the LAD and the diagonal branch (18.2%) were occluded or stenosed more than 50%, respectively (p = 0.68). Seventy-nine percent of LITA graft stenoses were located at the peripheral anastomosis. CONCLUSIONS: Patency of single LITA grafts to the diagonal branch or sequential LITA grafts to the LAD and diagonal branch were comparable to single LITA grafts to the LAD. Most stenoses of LITA grafts were located at peripheral anastomoses.

Aged↗

Incidence and characteristics of segmental postsystolic longitudinal shortening in normal, acutely ischemic, and scarred myocardium.

OBJECTIVE: Myocardial longitudinal shortening after aortic valve closure (postsystolic shortening [PSS]) is considered a marker of pathology with diagnostic potential. However, PSS can also occur in healthy subjects. We, therefore, investigated the occurrence and characteristics of PSS in control subjects and patients, and how to distinguish normality from disease. METHODS: In 20 young control subjects, 10 older control subjects, 30 patients with acute myocardial infarction (acute ischemia), and 10 patients with postischemic myocardial scar, longitudinal myocardial deformation was measured with Doppler tissue strain rate (SR) imaging. Segmental SR and strain were visually and quantitatively analyzed and compared. RESULTS: In young control subjects, PSS was found in 98 of 313 segments (31%) and showed gaussian distribution (median 1.3%). During ejection time, median peak SR was -1.4 s(-1) and median strain -16.6%. In older control subjects, parameters differed only slightly. In acutely ischemic and scarred myocardium, both systolic strain and SR were significantly reduced or inverted. In disease, PSS occurred significantly more often (78% and 79%, respectively), was significantly higher in magnitude, and its peak occurred later than in young and older control subjects. CONCLUSION: PSS is a normal finding in healthy subjects occurring in approximately one-third of myocardial segments and, thus, is not always a marker of disease. Our data indicate that pathologic PSS can be detected by coexisting reduction in systolic strain and, second, by exceeding a postsystolic strain magnitude cutoff.

Echocardiography, Doppler, Color↗

Enhanced levels of CD154 (CD40 ligand) on platelets in patients with chronic heart failure.

BACKGROUND: Inflammation plays a significant contributory role in the pathogenesis of chronic heart failure (CHF). Previous data have shown enhanced plasma levels of proinflammatory cytokines, i.e. TNF-alpha and IL-6, as well as a persistent immune activation in patients with CHF. Furthermore, the immune modulator CD154 has been receiving increased attention, since it plays a key role in the pathophysiology of multicellular vascular events such as thrombosis, inflammation and atherosclerosis. Since CD154 initiates and maintains the release of proinflammatory cytokines from endothelial cells, its potential role for the development and progression of CHF is of interest. METHODS: Fifty patients with CHF (aged 66.9+/-12.6 years, mean ejection fraction 22.1+/-9.2%, NYHA II-IV, 39 of ischemic origin, 11 with idiopathic dilated cardiomyopathy) and 15 healthy controls (aged 62.5+/-9.8 years) were examined. Thirty-two patients were taking aspirin (100 mg/day). Blood was drawn from a peripheral vein and immediately fixed with 1% paraformaldehyde, incubated with anti-CD154, anti-P-selectin, and anti-CD61 and thereafter analyzed by flow cytometry. RESULTS: Patients with CHF showed significantly enhanced expression of platelet-bound CD154 and P-selectin as compared to controls (CD154: median 35.6 25th percentile: 26.3; 75th percentile: 44.6 vs. 12.8; 25th: 6.8; 75th: 15.6 mean fluorescence intensity [MFI], P<0.001; P-selectin: median 3.2 25th percentile: 1.9; 75th percentile: 5.9 vs. 1.4; 25th: 1.2; 75th: 1.9, MFI, P<0.001). CD154 expression on platelets positively correlated with increasing NYHA-class. In contrast, no significant differences in serum levels of soluble CD154 or CD40 expression on monocytes were detected in the study groups. Antiplatelet-therapy with aspirin did not influence CD154 or P-selectin expression on platelets. CONCLUSION: Our pilot study demonstrates significantly enhanced levels of CD154 on platelets in patients with CHF. This suggests that the CD40-CD154 axis may contribute to the proinflammatory milieu, which exists in CHF and thus may play a pathogenic role in the development and progression of CHF.

Aged↗

Decrease of serum levels of the anti-inflammatory cytokine interleukin-10 in patients with advanced chronic heart failure.

Inflammation plays a significant contributory role in the pathogenesis of chronic heart failure (CHF). Many studies have shown enhanced plasma levels of proinflammatory cytokines [i.e. tumour necrosis factor-alpha (TNF-alpha) and interleukin (IL)-6] in patients with CHF. However, there are only few reports on the regulation of anti-inflammatory cytokines such as IL-10. IL-10 has potent deactivating properties in macrophages and T-cells and thus acts as a down-regulator of cell-mediated immune responses. The aim of the present study was to assess whether serum concentrations of IL-10 significantly differ between patients with CHF and healthy control subjects. Patients with CHF [ n =50; 66.9+/-12.6 years; mean ejection fraction, 22.1+/-9.2%; New York Heart Association (NYHA) class II-IV] and 25 healthy controls (63.6+/-10.2 years) were examined. Of the 50 patients with CHF, 32 patients were taking aspirin (100 mg/day) and 33 patients had lipid-lowering therapy with a statin. Serum IL-10 as well as TNF-alpha concentrations were measured using commercially available immunoassays. Patients with CHF showed significantly lower IL-10 concentrations (2.3+/-1.9 compared with 5.2+/-2.3 pg/ml; P <0.001). Patients with advanced CHF (NYHA class III and IV) had the lowest IL-10 plasma levels. Aspirin and statin therapy did not significantly influence serum levels of IL-10. The ratio of TNF-alpha to IL-10 was significantly higher in patients with advanced CHF (NYHA class III and IV, ratio 3.2+/-1.2 and 3.1+/-1.1 respectively, compared with control 0.4+/-0.2; P <0.01). Our present study demonstrates significantly decreased serum levels of IL-10 in patients with advanced CHF. Since IL-10 is known as a potent anti-inflammatory cytokine, its decrease in advanced CHF may favour the inflammatory milieu in CHF.

Aged↗

Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography.

RATIONALE AND OBJECTIVES: To compare the image quality of electron beam tomography (EBT) and multislice spiral CT (MSCT) for coronary artery visualization. MATERIALS AND METHODS: Two groups of 30 patients without coronary stenoses were studied by MSCT (4 x 1 mm collimation) or EBT (3 mm slice thickness). Contrast-to-noise ratio (CNR), overall length of the visualized arteries and vessel length free of motion artifacts were measured. RESULTS: Length of visualized arteries was equal in MSCT and EBT. In EBT, longer segments were depicted free of motion artifacts (MSCT: 73%, EBT: 92% of visualized length, P< 0.001) and CNR was significantly higher than in MSCT (15.4 vs. 9.0; P< 0.001). In both modalities, vessel diameters correlated closely to quantitative coronary angiography. CONCLUSIONS: EBT and MSCT permit reliable coronary artery visualization and measurement of vessel diameters. For the used scan protocol, MSCT images had a lower CNR and were more frequently affected by motion.

Aged↗

Diagnostic value of maximum intensity projections versus source images for assessment of contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography.

RATIONALE AND OBJECTIVES: We compared maximum intensity projections (MIP) versus original source images (SI) in respect to detection of coronary artery stenoses by means of magnetic resonance (MR) coronary angiography. METHODS: MR coronary angiography was performed on 61 patients. MIP and SI were independently evaluated as to presence of significant stenoses in the proximal and midcoronary segments and compared with x-ray angiography. RESULTS: A total of 315 of 427 (74%) coronary artery segments could be evaluated in MIP and 328 of 427 (77%) in SI. In segments able to be evaluated, MIP images demonstrated 84% (54/64) sensitivity and 87% (219/251) specificity, whereas SI images showed 85% (58/68) sensitivity and 90% (235/260) specificity. Overall accuracy was 87% (273/310) for MIP and 89% (293/328) for SI. There was no statistically significant difference between both modalities. CONCLUSIONS: The MIP reconstructions showed comparable accuracy to unprocessed SI. However, MIP postprocessing is compromised by a higher number of images that were unable to be evaluated due to overlap of coronary arteries with adjacent cardiac structures.

Algorithms↗

Direct coronary stenting versus predilatation followed by stent placement.

Direct stenting without antecedent dilatation may reduce procedural time, costs, and radiation exposure, and may result in less vessel injury. The purpose of this investigation was to compare immediate and long-term clinical and angiographic outcomes of direct stenting with stent placement after initial balloon dilation. Three hundred thirty-five symptomatic patients with single or multiple coronary lesions (diameter reduction 60% to 95%) of < or =30 mm length and with a vessel diameter of 2.5 to 4.0 mm were randomized either to direct stenting (group A, n = 171) or stenting after predilation (group B, n = 164). Patients with vessels with excessive calcification, severe proximal tortuosity, or occlusion were excluded. All patients were asked to return for routine repeat angiography at 6 months, irrespective of symptoms. Feasibility of direct stenting was 95% in group A, with 5% requiring crossover to predilation. Successful stent placement after predilation was performed in all 164 patients in group B. Direct stenting was associated with less procedural duration (group A 42.1 +/- 18.7 minutes vs group B 51.5 +/- 23.8 minutes, p = 0.004), radiation exposure time (group A 10.3 +/- 7.7 minutes vs group B 12.5 +/- 6.4 minutes, p = 0.002), amount of contrast dye used (group A 163 +/- 69 ml vs group B 197 +/- 84 ml, p <0.0001), and lower procedural costs (group A 845 +/- 167 vs group B 1,064 +/- 175, p <0.0001). Immediate angiographic results and in-hospital clinical outcomes (death, Q-wave myocardial infarction, repeat revascularization) were not significantly different between both strategies. However, at 6-month follow-up, direct stenting was associated with a lower angiographic restenosis (group A 20% vs group B 31%, p = 0.048) and target lesion revascularization rates (group A 18% vs group B 28%; p = 0.03). This study demonstrates the feasibility, safety, and outcomes of direct stenting in eligible coronary lesions. In appropriately selected cases, direct stenting has a lower rate of angiographic restenosis up to 6 months after the procedure, resulting in fewer coronary reinterventions compared with the conventional strategy of stenting with antecedent dilatation.

Aged↗

Comparison of contrast-enhanced breath-hold and free-breathing respiratory-gated imaging in three-dimensional magnetic resonance coronary angiography.

Suppression of respiratory motion is one of the major challenges of magnetic resonance (MR) coronary angiography. Two approaches to compensate for respiratory motion have often been proposed: breath-hold (BH) and free-breathing respiratory-gated (FBRG) imaging. So far, however, these approaches have never been directly compared. MR coronary angiography was performed in 32 patients with suspected coronary artery disease. MR data were acquired using contrast-enhanced BH and FBRG 3-dimensional MR coronary angiographic techniques. MR images were compared with regard to image quality using quantitative parameters and with regard to accuracy for stenosis detection in the proximal and mid-coronary segments in comparison to x-ray angiography. With regard to image quality, BH was superior to FBRG. Signal-to-noise ratio was 29.1 +/- 10.7 for BH versus 18.8 +/- 9.7 for FBRG (p <0.05) and contrast-to-noise was 18.0 +/- 7.4 for BH versus 11.3 +/- 7.9 for FBRG (p </=0.05). One hundered seventy-one of 224 coronary artery segments (76%) were evaluable in BH compared with 155 of 224 in FBRG (69%). In the evaluable segments, BH demonstrated a sensitivity of 87% (26 of 30 stenoses detected) and specificity of 92% (129 of 141 nonstenotic segments correctly identified), whereas FBRG showed a sensitivity of 60% (15 of 25) and specificity of 89% (115 of 130). Overall accuracy was 91% (155 of 171) for BH and 84% (130 of 155) for FBRG. Sensitivity was significantly higher for BH (p = 0.0320), whereas specificity and overall accuracy were not significantly different. Thus, contrast-enhanced BH MR coronary angiography compares favorably to FBRG imaging with regard to image quality and detection of coronary stenoses.

Adult↗

Influence of lipid-lowering therapy on the progression of coronary artery calcification: a prospective evaluation.

BACKGROUND: Coronary calcification measured by fast computed tomography techniques is a surrogate marker of coronary atherosclerotic plaque burden. In a cohort study, we prospectively investigated whether lipid-lowering therapy with a cholesterol synthesis enzyme inhibitor reduces the progression of coronary calcification. METHODS AND RESULTS: In 66 patients with coronary calcifications in electron beam tomography (EBT), LDL cholesterol >130 mg/dL, and no lipid-lowering treatment, the EBT scan was repeated after a mean interval of 14 months and treatment with cerivastatin was initiated (0.3 mg/d). After 12 months of treatment, a third EBT scan was performed. Coronary calcifications were quantified using a volumetric score. Cerivastatin therapy lowered the mean LDL cholesterol level from 164+/-30 to 107+/-21 mg/dL. The median calcified volume was 155 mm3 (range, 15 to 1849) at baseline, 201 mm3 (19 to 2486) after 14 months without treatment, and 203 mm3 (15 to 2569) after 12 months of cerivastatin treatment. The median annualized absolute increase in coronary calcium was 25 mm3 during the untreated versus 11 mm3 during the treatment period (P=0.01). The median annual relative increase in coronary calcium was 25% during the untreated versus 8.8% during the treatment period (P<0.0001). In 32 patients with an LDL cholesterol level <100 mg/dL under treatment, the median relative change was 27% during the untreated versus -3.4% during the treatment period (P=0.0001). CONCLUSIONS: Treatment with the cholesterol synthesis enzyme inhibitor cerivastatin significantly reduces coronary calcium progression in patients with LDL cholesterol >130 mg/dL.

Adult↗

Sequential vs. kissing balloon angioplasty for stenting of bifurcation coronary lesions.

Coronary angioplasty of bifurcation lesions remains a technical challenge and is believed to result in low procedural success associated with the risk of side-branch occlusion. Furthermore, long-term results are associated with a high rate of reintervention. The aim of the study was to evaluate the immediate and long-term clinical and angiographic results of sequential vs. simultaneous balloon angioplasty (kissing balloon technique) for stenting of bifurcation coronary lesions. Between December 1999 and January 2001, 59 patients underwent coronary angioplasty because of symptomatic bifurcation lesions type III (i.e., side branch originates from within the target lesion of the main vessel, and both main and side branch are angiographically narrowed more than 50%). Twenty-six patients were treated with simultaneous and 33 patients with sequential balloon angioplasty. Main-vessel stent placement was mandatory; side-branch stenting and platelet IIb/IIIa antagonists were allowed at the discretion of the operator. Kissing balloon technique offered no advantage in terms of procedural success or need for repeat target vessel revascularization due to restenosis at 6-month follow-up. Using sequential balloon angioplasty, permanent or transient side-branch compromise rate (TIMI flow < 3) was significantly higher than after kissing balloon technique (33% vs. 0%, respectively; P = 0.003). Major clinical events in-hospital or at 6-month follow-up, however, showed no significant differences. Kissing balloon angioplasty reduces the rate of transient side-branch occlusion compared to sequential PTCA but does not improve immediate or long-term outcome compared to sequential PTCA for stenting of bifurcation lesions.

Aged↗

Transradial approach for coronary angioplasty in the setting of acute myocardial infarction: a dual-center registry.

Although transradial angioplasty has been shown to have no major entry site-related complications, its clinical applicability for balloon angioplasty and stenting in acute myocardial infarction (AMI) is unclear. In order to assess the feasibility, safety, and clinical outcome of transradial access for coronary angioplasty (PTCA) and stenting during AMI, transradial angioplasty for AMI was registered on a prospective database at two European sites (A and B) with experience in the radial approach (RA); 6 Fr catheters with an inner lumen of at least 0.064" and low-profile rapid-exchange balloons were used. Primary success rates and procedural complications of 6 Fr RA were determined and compared to 6 Fr femoral approach (FA) procedures. A total of 1,224 AMI patients entered the registry. Study site A enrolled 185 RA patients (13.6% AMI) and study site B 92 RA patients (63.4%). Patient baseline demographics were similar in both study centers and showed no differences between RA and FA patients, except a more frequent use of abciximab in study site B compared to A. PTCA was successful in > 95% of both RA and FA patients. Total procedural time did not differ between RA and FA patients. Severe access site-related bleeding complications, however, were observed in FA patients only: study site A used closure devices routinely and found 2% severe bleedings; study site B used no closure device for FA patients and observed 7% severe bleedings. In selected patients and in experienced hands, transradial PTCA in AMI has a high success rate, is clinically safe, and could become an attractive alternative access site for patients being at high or even low risk for bleeding complications.

Aged↗

Induction of cyclooxygenase-2 and enhanced release of prostaglandin E(2) and I(2) in human endothelial cells by engagement of CD40.

OBJECTIVES: The hypothesis was tested that CD40-CD154 interaction is involved in the induction of cyclooxygenase-2 and the release of prostanoids in human endothelial cells. METHODS AND RESULTS: In a coculture model of human endothelial cells and a transfected CD154 positive cell line, engagement of CD40 on endothelial cells dramatically increased the synthesis of prostacyclin, prostaglandin E(2) and thromboxane A(2). This upregulation was mediated through an induction of cyclooxygenase-2 (Cox-2), as it was blocked by Cox-2-selective inhibitors. Western blot analysis demonstrated that Cox-2 protein was markedly increased in endothelial cells following CD40 engagement, an effect that was inhibited by pretreatment of cells with an anti-CD154 antibody. CONCLUSION: The data indicate that signaling via CD40 constitutes a major pathway in human endothelial cells for the induction of Cox-2 and release of prostanoids. The CD40-Cox-2 axis thus may represent an important pathway for initiating or maintaining an inflammatory process at the vessel wall.

Blotting, Western↗

Strain rate imaging for the assessment of preload-dependent changes in regional left ventricular diastolic longitudinal function.

BACKGROUND: Strain rate imaging is a new and intriguing way of displaying myocardial deformation properties by means of echocardiography. With high frame rate strain rate imaging we observed a spatial inhomogeneity in diastolic longitudinal strain rates in healthy persons. A base-to-apex time delay in diastolic lengthening could be seen both in early diastole and at atrial contraction. METHODS AND RESULTS: We investigated this consistent finding and its dependence on loading conditions in 20 healthy volunteers. Propagation velocities of lengthening of 91 +/- 31 cm/s (E-wave) and 203 +/- 11 cm/s (A-wave) at rest (equal to time delays of 104 +/- 29 ms and 56 +/- 24 ms, respectively) increased significantly to 101 +/- 27 cm/s (E) and 283 +/- 17 cm/s (A) with lifting the volunteers' legs. Applying nitroglycerin sublingually and sitting upright significantly decreased propagation velocities (E-wave 76 +/- 20 cm/s, A-wave 172 +/- 93 cm/s and E-wave 66 +/- 17 cm/s, A-wave 150 +/- 64 cm/s, respectively). Free lateral walls showed a lower propagation velocity than septal walls. CONCLUSION: We conclude that the propagation velocities of left ventricular lengthening waves are dependent on preload changes and increase with increasing preload.

Adult↗

A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

RATIONALE AND OBJECTIVES: To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS: One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent). MRI was performed using respiratory-gated sequences (24-48 cross-sections, 2-mm slice thickness, 20 mL Gd-DTPA). EBT and MRI images were evaluated concerning high-grade post-PTCA restenosis (> or = 70%) and validated against coronary angiography. RESULTS: In EBT, 28 patients and in MRI, 31 patients were not evaluable. In the remaining patients, sensitivity for restenosis detection was 90% in EBT (17/19) and 73% in MRI (11/15; P = 0.370). In EBT, specificity was significantly higher (66% vs. 49%, P = 0.043). Overall accuracy was 71% for EBT and 53% for MRI (P = 0.014). CONCLUSIONS: For the detection of high-grade restenosis after PTCA, EBT demonstrated significantly higher accuracy than MRI.

Angioplasty, Balloon, Coronary↗

Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection.

OBJECTIVE: Although multidetector CT (MDCT) with retrospectively ECG-gated image reconstruction has been shown to permit noninvasive visualization of the coronary arteries, the 125-250 msec required for image acquisition frequently causes motion artifacts. We investigated the influence of a patient's heart rate on the presence of motion artifacts and on accuracy of stenosis detection on contrast-enhanced MDCT. MATERIALS AND METHODS: In 100 patients, MDCT was performed, and ECG-gated cross-sectional images were retrospectively reconstructed. From the 10 data sets obtained for each patient (reconstructed at 0-90% of the cardiac cycle in increments of 10%), we chose the best data set for every coronary artery. The images of the arteries were evaluated for occurrence of artifacts and the presence of high-grade stenosis (diameter reduction exceeding 70%) or occlusions. MDCT results were compared with coronary angiographic findings. RESULTS: Of the 400 coronary arteries, 115 (29%) could not be evaluated because of motion artifacts (n = 84) or other reasons (n = 31). Overall, 51 (49%) of 104 stenoses were revealed on MDCT. For detecting stenosis in those arteries that we could evaluate, MDCT had a sensitivity of 91% (51 of 56 stenoses detected) and a specificity of 89%. As the heart rate increased, the number of arteries that could be evaluated decreased, and overall sensitivity for stenosis detection decreased from 62% (heart rate < or = 70 beats per minute) to 33% (heart rate > 70 beats per minute). CONCLUSION: MDCT can reveal coronary stenoses, but the usefulness of MDCT as an aid in accurately evaluating stenoses decreases as a patient's heart rate increases.

Adult↗