PubMed Health⌕ Search

Biomedical subjects

Werner Herrmann

Publications and source records attributed to Werner Herrmann.

3 recordsLinked to original sources

ESR spin probes in ionic liquids.

The spin probes 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO), 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPOL), and 2,2,6,6-tetramethyl-4-trimethylammoniumpiperidine-1-oxylIodide (CAT-1) are examined in a number of ionic liquids based on substituted imidazolium cations and tetrafluoroborate and hexafluorophosphate anions, respectively. The reorientation correlation times tau(R) of the spin probes in these systems have been determined by complete spectra simulation and, for rapid reortientation, by analysis of the intensities of the hyperfine lines of the electron spin resonance (ESR) spectra. A comparison of the results with those from the model system glycerol/water and selected organic solvents is made. Additions of diamagnetic and paramagnetic ions allow the conclusion that salt effects and spin exchange are present, and that both are superimposed by motional effects. Specific interactions in the ionic liquids, as well as between the spin-probe molecules and the constituents of the ionic liquids are reflected in the spectra of the spin probes, depending on their molecular structure.

Anions↗

Microenvironmental pH and microviscosity inside pH-controlled matrix tablets: an EPR imaging study.

Incorporation of pH modifiers is a commonly used strategy to enhance the dissolution rate of weakly basic drugs from sustained release solid dosage forms. Electron paramagnetic resonance imaging (EPRI) was applied to spatially monitor pH(M) and the rotational correlation time (tau(R)), a parameter which is closely related to the surrounding microviscosity inside HPMC (hydroxypropylmethylcellulose) matrix tablets. Fumaric, citric, and succinic acid were employed as pH modifiers. 4-(methylamino)-2-ethyl-5,5-dimethyl-4-pyridine-2-yl-2,5-dihydro-1H-imidazole-1-oxyl (MEP) was used as spin label. Fumaric and citric acid reduced the pH(M) to equal extents in the initial phase. With the progress of hydration, the more soluble citric acid diffused out from the tablet resulting in an increase in pH(M), originating at the outer layers. In contrast, fumaric acid maintained a constantly reduced pH(M) inside the entire tablet. Due to its lower acidic strength, succinic acid did not reduce the pH(M) as effectively as the other pH modifiers used. The more water-soluble acids stimulated the water penetration into the matrix system, thereby rapidly decreasing tau(R). Once the matrix tablets were hydrated, the included pH modifiers influenced tau(R) insignificantly. EPRI, a novel approach for monitoring pH(M) and tau(R) non-invasively and spatially resolved, was used successfully for the optimization of an pH-controlled formulation.

Chemistry, Pharmaceutical↗

In vivo ESR studies on subcutaneously injected multilamellar liposomes in living mice.

PURPOSE: An innovative, noninvasive, low-frequency electron spin resonance (ESR) spectroscopy method was applied and adapted to investigate the integrity of multilamellar liposomes from hydrogenated phospholipids after subcutaneous injection in living mice. Moreover, the fate of the injected liposomal preparations was examined, as well as the possibility to achieve a depot effect. METHODS: Highly concentrated solutions of the spin probe 2,2,6,6-tetramethyl-4-trimethylammoniumpiperidine-1-oxyl-iodide (CAT-1; 138 mM) were encapsulated in liposomes. They were characterized by laser diffraction, and the liberation of spin probe was investigated by ESR spectroscopy. RESULTS: Line shape changes allowed the differentiation between encapsulated and released CAT-1 after subcutaneous injection of liposomes. Multilamellar liposomes form a local depot at the site of injection. A sustained release of the spin probe from the depot was monitored by means of ESR. Whereas 40% of the spin probe was released within the first 96 h after administration, 60% remained in intact liposomes under the skin. No depot formation could be observed after injection of CAT-1 solutions, but a fast signal decrease due to systemic distribution and bioreduction of the nitroxide spin probe. CONCLUSIONS: Noninvasive analysis of liposomal integrity in living animals was successfully accomplished using a new L-Band ESR spectroscopy method. The liberation of CAT-1 from liposomes in vitro and in vivo was monitored by changes in the lineshape of ESR spectra and Heisenberg spin exchange. The significance of liposomal integrity for the formation of a localized drug depot effect was proved.

Animals↗