PubMed Health⌕ Search

Biomedical subjects

Werner Klein

Publications and source records attributed to Werner Klein.

26 records · Page 2Linked to original sources

Effect of beta(1)-selective adrenergic blockade on maximal blood lactate steady state in healthy men.

The aim of this study was to compare the effect of taking bisoprolol (B), a highly beta(1)-selective adrenoceptor antagonist to that of a placebo (P) on maximal lactate steady state (MLSS), which reflects the transition from oxidative to partially anaerobic metabolism. Ten healthy male subjects [mean (SD) age 23 (3) years, height 181 (6) cm, body mass 76 (6) kg] randomly received oral P or B (5 mg x day(-1)) for 2 weeks using a double-blind crossover design. In the 2nd week, the subjects performed an incremental cycle ergometer test until exhaustion to determine the second blood lactate turn point (LTP(2)). At regular intervals of 24-48 h, the subjects performed 2-3 steady-state tests to determine the MLSS. During the incremental exercise, heart rate (HR) was significantly lower at rest (15 beats x min(-1)), at LTP(2) (23 beats x min(-1)) and at maximal power output (19 beats x min(-1)) when taking B compared to P. Oxygen pulse was significantly higher taking B and no significant differences were observed for any of the respiratory gas exchange measurements (RGEM) (oxygen consumption, carbon dioxide production, minute ventilation, respiratory exchange ratio), exercise intensity or blood lactate concentration (LA) at baseline, at LTP(2) and at maximal power output. During exercise at constant intensity, significant differences between B and P were found for HR [148 (12) compared to 176 (11) beats x min(-1)] and oxygen pulse [21.8 (1.9) compared to 19.2 (1.6) ml] at MLSS. No difference was found for exercise intensity [216 (18) compared to 218 (18) W], for RGEM, LA [5.3 (1.1) compared to 4.8 (1.5) mmol x l(-1)] and ratings of perceived exertion [18.1 (1.6) compared to 17.4 (1.7)] for B and P at MLSS. In both, the power output at LTP(2) was slightly higher than power output at MLSS (within an intensity step). Commonly measured cardiorespiratory and subjective variables determined during treatment with 5 mg bisoprolol can be used for testing cardiorespiratory fitness and for prescription of training intensity.

Adrenergic beta-Antagonists↗

Chapter three: methodology of exposure modeling.

In this chapter, the concept of exposure assessment and its evolution is introduced, and evaluated by critically appraising the pertinent literature as it applies to exposures to Particulate Matter (PM). Exposure measurement or estimation methodologies and models are reviewed. Three exposure/measurement methodologies are assessed. Estimation methods focus on source evaluation and attribution, sources include those outdoors and indoors as well as in occupational and in-transit environments. Fate and transport models and their inputs are addressed to estimate concentrations outdoors and indoors; source attribution techniques help focus on the contributing sources. Activity pattern techniques are also reviewed and their use in exposure models to estimate inhalation exposure to PM is presented. Deterministic, regression and other stochastic models of exposure to PM are reviewed and evaluated. Strengths, limitations, assumptions and affirmations of the use of exposure assessment as an integral component of risk assessment and risk management are discussed in the conclusions and discussions section of this work.

Air Pollutants↗

Investigations on the binding mechanism of the herbicide simazine to dissolved organic matter in leachates of compost.

14C-labelled simazine was composted together with biowaste on a pilot (m3) scale. The herbicide was quickly bound to the compost matrix. By aqueous extraction of 29 and 200 days old compost (equivalent to thermophilic and mesophilic phase of composting) only 4.2% and 3.1% respectively of the radioactivity in the compost samples could be extracted with water. Analysis of the extracts using high-performance size exclusion chromatography (HPSEC) revealed that the dissolved organic matter (DOM) had molecular weights ranging between 2 and 28 kDa. The amount of DOM-associated radioactivity increased from 53% (day 29) to 65% (day 200) of total extractable radioactivity. The type of binding of the 14C-labelled residues and the DOM was elucidated by silylation of humic matter and subsequent HPSEC. The data demonstrated that besides polar metabolites also intact simazine was bound to the DOM. A distinct shift from rather weak interactions to strong covalent linkages of simazine and its metabolites with increasing age of the compost was observed. The results showed that only low amounts of free simazine and its degradates can be extracted with water. We concluded that the shift towards stable covalent linkages is equivalent to a detoxification of the contaminant in aged compost. Consequently, the use of the analysed compost in its mature stage should not pose an environmental risk to the groundwater or the subsoil.

Carbon Radioisotopes↗

Exercise does not affect plasma concentrations of (R)- and (S)-carvedilol.

PURPOSE: In vitro studies have shown that beta-blockers are taken up into and released from adrenergic cells. As a consequence, plasma concentrations of beta-blockers increase during exercise together with those of epinephrine and norepinephrine. However, effects of exercise on plasma concentrations of (R)- and (S)-carvedilol are unknown. METHODS: Twelve healthy males received oral single doses of 12.5 mg (R)-carvedilol, 12.5 mg (S)-carvedilol and 25 mg (R,S)-carvedilol in a cross-over fashion; 11 patients with essential arterial hypertension were given 25 mg (R,S)-carvedilol. Exercise was performed 3 hours following drug intake, and blood samples were taken at rest, at the end of exercise, and after 15 min of recovery. Plasma concentrations of (R)- and (S)-carvedilol were determined by HPLC. RESULTS: Plasma concentrations of (R)-carvedilol were 2- to 3-fold higher than those of (S)-carvedilol (p < 0.05 in all cases). Plasma concentrations of both (R)- and (S)-carvedilol remained unaffected during exercise and recovery. CONCLUSIONS: Contrary to all other beta-blockers so far investigated, exercise had no effect on plasma concentrations of (R)- and (S)-carvedilol. We conclude that neither (R)- nor (S)-carvedilol is released from adrenergic cells during exercise, a feature that clearly distinguishes carvedilol from other beta-blockers. Thus, the human organism appears to handle (R)- and (S)-carvedilol differently than other beta-adrenoceptor antagonists. This finding deserves further investigation on a molecular and cellular level in order to clarify these differences between the pharmacokinetics of carvedilol and other beta-blockers.

Administration, Oral↗

Unpredicted lack of effect of exercise on plasma concentrations of carvedilol.

In vitro studies have shown that beta-blockers are taken up into and released from adrenergic cells together with epinephrine and norepinephrine. Consequently, studies in humans revealed an increase in plasma concentrations of propranolol and atenolol during physical exercise. However, carvedilol has not been investigated in a similar fashion. Eleven hypertensive patients on long-term treatment (4 months) with carvedilol followed an exercise regimen. Plasma concentrations of carvedilol were determined at rest (9.7 +/- 3.4 ng/ml), during exercise (9.0 +/- 3.2 ng/ml), and after 15 min of recovery (9.1 +/- 2.7 ng/ml). Contrary to predictions, exercise had no effect on plasma concentrations of carvedilol, a finding that is in contrast to other beta-blockers. We conclude that carvedilol is not taken up into and released from adrenergic nerves during exercise, a feature that clearly distinguishes carvedilol from all other beta-adrenergic antagonists so far investigated.

Adrenergic beta-Antagonists↗

Pericardiocentesis Guided by Contrast Echocardiography.

Although pericardiocentesis is a relatively safe procedure, there are some hazards, particularly when hemorrhagic fluid is aspirated. Having the opportunity to outline the space from which the fluid is withdrawn is of particular interest in this situation. A current technique of echocardiography with contrast enhancement involves injection of a few milliliters of agitated saline solution or reinjection of blood-stained fluid. Performing this procedure, we repeatedly observed a weak and inhomogeneous echo contrast; therefore, we evaluated the applicability of the ultrasound contrast medium SH U 454 (Echovist Schering, Berlin, Germany) for contrast enhancement in hemorrhagic pericardiocentesis. In all patients, pericardiocentesis was performed in a supine position by a subxiphoid approach. A Teflon catheter/needle unit attached to a syringe containing a few milliliters of contrast medium was introduced in the usual way. On the return of hemorrhagic fluid, 1-2 ml of Echovist was injected to provide contrast from the space from which it had been aspirated. We observed excellent contrast clearly outlining the pericardial space through the injection of 1-2 ml of contrast medium. No adverse or side effects were seen resulting from Echovist injection to the pericardial sac. In conclusion, contrast echocardiography appears to be a useful tool to secure the correct position of the needle during pericardiocentesis of hemorrhagic or loculated effusions. It is suggested that injection of Echovist should be considered whenever the contrast obtained by the conventional technique is poor and inconclusive.

Journal Article↗

First use of the Cancion cardiac recovery system in a human.

Animal studies have shown clearly that a peripheral circulatory support system can effectively unload the left ventricle. We report here the first implantation of one such system (Cancion, Orqis Medical, Lake Forest, CA) in a human. The Cancion system consists of a centrifugal pump connected to the circulation via a graft cannula anastomosed to the left axillary artery and a percutaneous cannula placed into the left common femoral artery. Flow is initiated from the femoral to the axillary artery. The system was implanted in a 62-year-old man with ischemic cardiomyopathy suffering from decompensation whose condition had not improved with catecholamine therapy. The Cancion system supported the patient for 3 days, after which it was electively explanted. During the support period, pulmonary capillary wedge pressure dramatically decreased from 28 to 9 mm Hg, left ventricular diastolic dimension decreased from 6.78 to 6.16 cm, creatinine levels decreased from 1.9 to 0.9 mg/dl, cardiac index improved from 1.5 to 2.7 L/min, and ejection fraction improved from 25 to 35%. Together, our data indicate that the Cancion system quickly and effectively improved the patient's hemodynamics. This suggests that the device may one day become a short-term alternative to high dose inotrope therapy and that its application may delay the need for more invasive forms of mechanical circulatory support.

Blood Pressure↗