PubMed Health⌕ Search

Biomedical subjects

Wesley Lee

Publications and source records attributed to Wesley Lee.

33 records · Page 2Linked to original sources

Second-trimester sonography and trisomy 18.

OBJECTIVE: This report presents the findings seen on initial second-trimester sonography in a large group of fetuses with trisomy 18. The object of this study was to describe the types and frequencies of abnormal sonographic findings seen and to further evaluate those cases in which no abnormal findings were noted. METHODS: A retrospective chart review of the prenatal sonograms in cases of trisomy 18 was conducted. RESULTS: Forty-nine fetuses with trisomy 18 were examined by second-trimester sonography. Multiple fetal anomalies were seen in most cases. The most frequent structural findings involved the brain (82%), heart (55%), and upper extremities (53%). Growth abnormalities occurred in 39% of these fetuses. Choroid plexus cysts were the most common individual findings. Larger cysts increased the likelihood of trisomy 18, although no fetuses with trisomy 18 had isolated choroid plexus cysts. Seven fetuses (14%) had no anomalies seen on their initial scans. In each of these scans, the fetal anatomy was incompletely visualized because of technical constraints. Six had subsequent scans approximately 2 weeks later, which showed abnormal sonographic findings. CONCLUSIONS: Most fetuses with trisomy 18 were identified by structural anomalies, typically seen in the brain, heart, and upper extremities. Larger choroid plexus cysts were associated with this aneuploidy. Technical factors, which limit fetal visualization, were noted in all cases in which no sonographic abnormalities were detected during the initial sonographic examinations. Detection of abnormal cases will rely on a completed evaluation of a routine fetal anatomic survey.

Adult↗

Second-trimester sonography and trisomy 18: the significance of isolated choroid plexus cysts after an examination that includes the fetal hands.

OBJECTIVE: To estimate the risk of trisomy 18 with the finding of isolated choroid plexus cysts after a standard sonographic examination that is extended to include the fetal hands. METHODS: Aretrospective chart review was performed on all fetuses with choroid plexus cysts on second-trimester sonographic examinations. When choroid plexus cysts were identified, our standard protocol for fetal evaluation was expanded to include the hands. If no other findings were noted on completion of this examination, the choroid plexus cysts were classified as "isolated." These results were correlated with the presence or absence of trisomy 18 to determine the impact of this approach for the detection of fetuses with this aneuploidy. RESULTS: From March 1990 to the end of 2001, 49,435 fetuses that were subsequently delivered at our hospital were scanned between 16 and 25 menstrual weeks. At least 1 choroid plexus cyst was detected in 1209 fetuses (2.3%), of which 1060 were isolated. No fetuses with isolated choroid plexus cysts had trisomy 18. However, 3 fetuses with trisomy 18 had choroid plexus cysts and abnormal hands as their only abnormal findings. CONCLUSIONS: Fetuses with an apparently isolated finding of choroid plexus cysts can be further evaluated by extending the standard examination to include the hands. If no other findings are identified, the risk of trisomy 18 appears to be low.

Adult↗

Four-dimensional ultrasonography of the fetal heart using color Doppler spatiotemporal image correlation.

OBJECTIVE: To describe clinical and research applications of 4-dimensional imaging of the fetal heart using color Doppler spatiotemporal image correlation. METHODS: Forty-four volume data sets were acquired by color Doppler spatiotemporal image correlation. Seven subjects were examined: 4 fetuses without abnormalities, 1 fetus with ventriculomegaly and a hypoplastic cerebellum but normal cardiac anatomy, and 2 fetuses with cardiac anomalies detected by fetal echocardiography (1 case of a ventricular septal defect associated with trisomy 21 and 1 case of a double-inlet right ventricle with a 46,XX karyotype). The median gestational age at the time of examination was 21 3/7 weeks (range, 19 5/7-34 0/7 weeks). Volume data sets were reviewed offline by multiplanar display and volume-rendering methods. Representative images and online video clips illustrating the diagnostic potential of this technology are presented. RESULTS: Color Doppler spatiotemporal image correlation allowed multiplanar visualization of ventricular septal defects, multiplanar display and volume rendering of tricuspid regurgitation, volume rendering of the outflow tracts by color and power Doppler ultrasonography (both in a normal case and in a case of a double-inlet right ventricle with a double-outlet right ventricle), and visualization of venous streams at the level of the foramen ovale. CONCLUSIONS: Color Doppler spatiotemporal image correlation has the potential to simplify visualization of the outflow tracts and improve the evaluation of the location and extent of ventricular septal defects. Other applications include 3-dimensional evaluation of regurgitation jets and venous streams at the level of the foramen ovale.

Echocardiography, Four-Dimensional↗

Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation.

OBJECTIVE: This study was undertaken to describe a new technique for the examination of the fetal heart using four-dimensional ultrasonography with spatiotemporal image correlation (STIC). STUDY DESIGN: Volume data sets of the fetal heart were acquired with a new cardiac gating technique (STIC), which uses automated transverse and longitudinal sweeps of the anterior chest wall. These volumes were obtained from 69 fetuses: 35 normal, 16 with congenital anomalies not affecting the cardiovascular system, and 18 with cardiac abnormalities. Dynamic multiplanar slicing and surface rendering of cardiac structures were performed. To illustrate the STIC technique, two representative volumes from a normal fetus were compared with volumes obtained from fetuses with the following congenital heart anomalies: atrioventricular septal defect, tricuspid stenosis, tricuspid atresia, and interrupted inferior vena cava with abnormal venous drainage. RESULTS: Volume datasets obtained with a transverse sweep were utilized to demonstrate the cardiac chambers, moderator band, interatrial and interventricular septae, atrioventricular valves, pulmonary veins, and outflow tracts. With the use of a reference dot to navigate the four-chamber view, intracardiac structures could be simultaneously studied in three orthogonal planes. The same volume dataset was used for surface rendering of the atrioventricular valves. The aortic and ductal arches were best visualized when the original plane of acquisition was sagittal. Volumes could be interactively manipulated to simultaneously visualize both outflow tracts, in addition to the aortic and ductal arches. Novel views of specific structures were generated. For example, the location and extent of a ventricular septal defect was imaged in a sagittal view of the interventricular septum. Furthermore, surface-rendered images of the atrioventricular valves were employed to distinguish between normal and pathologic conditions. Representative video clips were posted on the Journal's Web site to demonstrate the diagnostic capabilities of this new technique. CONCLUSION: Dynamic multiplanar slicing and surface rendering of the fetal heart are feasible with STIC technology. One good quality volume dataset, obtained from a transverse sweep, can be used to examine the four-chamber view and the outflow tracts. This novel method may assist in the evaluation of fetal cardiac anatomy.

Cohort Studies↗

Clinical outcome of fetuses with sonographic diagnosis of isolated micrognathia.

OBJECTIVE: To describe the clinical outcome of fetuses with the prenatal sonographic diagnosis of isolated micrognathia. METHODS: A retrospective review of fetuses and infants with the prenatal diagnosis of isolated micrognathia for April 1990 to August 2001 was undertaken. Isolated micrognathia was considered if no other anatomic, growth, or amniotic fluid abnormalities were detected by a detailed ultrasound examination. Sources of outcome data included maternal and neonatal medical records, prenatal genetics records, and karyotype results. RESULTS: Fifty-eight fetuses with the diagnosis of micrognathia were identified. Fifteen fetuses (26%) had isolated micrognathia by prenatal sonogram. After neonatal examination, 14 of 15 were found to have at least one additional abnormality. Eleven had a cleft of the soft and/or hard palate. Seven (54%) of 13 live-born neonates had mild to severe airway obstruction that required intervention. Four (31%) of 13 experienced feeding difficulties of varying duration. Follow-up data were available for 1 to 10 years. Eight (62%) of 13 children are reported to be doing well. Five (38%) of 13 children are reported to have mild to severe developmental delay. CONCLUSION: If micrognathia is the only sonographic finding identified, physicians and families should be prepared for possible respiratory difficulty at delivery, the presence of a cleft palate, and/or developmental delay.

Adult↗

Three-dimensional color power imaging of the fetal hepatic circulation.

OBJECTIVE: The purpose of this study was to describe the use of three-dimensional power Doppler ultrasonography to identify vascular congenital anomalies of fetal portosystemic and umbilical venous systems. STUDY DESIGN: In a prospective study, the hepatic and umbilical venous systems were examined in 390 fetuses with two-dimensional ultrasonography, color, and spectral Doppler imaging. Fetuses suspected to have anomalies of the portal system and ductus venosus were additionally examined with three-dimensional power Doppler ultrasonography. RESULTS: Vascular anomalies were identified in 8 fetuses (absent ductus venosus, n=4; direct connection between the umbilical vein and the right atrium, n=2; and direct connection between the umbilical vein and the inferior vena cava, n=2) out of the 310 in which the venous system could be adequately imaged (prevalence=2.6%). Three-dimensional power Doppler imaging showed the course of the umbilical vein, its relationship to the portosystemic circulation, and whether a ductus venosus was present. CONCLUSION: Three-dimensional power Doppler ultrasonography can be used to image normal fetal hepatic and portal circulation, as well as identify anomalies of the fetal portosystemic and umbilical venous systems.

Female↗

The early sonographic appearance of placenta accreta.

OBJECTIVE: To determine whether any sonographic findings in the first trimester predict placenta accreta. METHODS: Patients who had a diagnosis of placenta accreta, increta, or percreta by clinical course or pathologic examination of the uterus and who had had a sonographic examination at 10 weeks or earlier were included in this study. RESULTS: Seven patients met the study criteria. In 6 of these, who had had at least 1 previous cesarean delivery, the gestational sac was located in the lower uterine segment at the time of the early scan. Two of these pregnancies failed shortly after the early scan, and the patients underwent dilation and curettage, at which time severe bleeding necessitated a hysterectomy. The other 4 continued to term but had sonographic findings typical of placenta accreta during subsequent scans. In the seventh patient (who had had no previous cesarean deliveries), the gestational sac was located in the uterine fundus. CONCLUSIONS: In a patient with a previous cesarean delivery, a sac lying in the lower uterine segment on a scan at 10 weeks or earlier suggests the possibility of placenta accreta.

Adult↗

Nasal bone evaluation in fetuses with Down syndrome during the second and third trimesters of pregnancy.

OBJECTIVE: This study examined the use of three-dimensional ultrasonography for evaluating the fetal nasal bone, as a sonographic marker of Down syndrome, during the second and early third trimesters of pregnancy. METHODS: Forty fetuses, including 20 with trisomy 21, were scanned once by three-dimensional ultrasonography. A midline sagittal view of the facial profile was used to analyze the volume data. Independent examiners reviewed blinded and randomly allocated volume data sets for the nasal bone. Interobserver reliability was evaluated for the sonographic presence or absence of the nasal bone. Logistic regression determined the contribution of this parameter to the presence of Down syndrome. RESULTS: Both examiners showed substantial agreement in scoring whether the nasal bone was visualized by three-dimensional ultrasonography (P < .001). They identified 40% to 45% of fetuses with abnormalities using the absence of the nasal bone as a sonographic marker. However, a substantial number of fetuses with abnormalities were also found to have a nasal bone present. The nasal bone was visualized in 80% to 90% of fetuses without abnormalities. CONCLUSIONS: Three-dimensional ultrasonography can be used to evaluate the fetal nasal bone with substantial interobserver agreement during the second and early third trimesters of pregnancy. A nonvisualized nasal bone identified 40% to 45% of fetuses with Down syndrome in this study.

Down Syndrome↗

Three-dimensional power Doppler ultrasonography during pregnancy.

OBJECTIVES: To present the appearance of fetal and placental vascular anatomic structures by three-dimensional power Doppler ultrasonography. METHODS: Three-dimensional multiplanar imaging, surface rendering, and volume rendering were combined with power Doppler ultrasonography to show the methods, imaging artifacts, and diagnostic potential of this technology during pregnancy. RESULTS: Fetuses with normal and abnormal vascular anatomic structures were evaluated by three-dimensional power Doppler ultrasonography. The combination of several imaging modalities (e.g., three-dimensional multiplanar imaging, surface rendering, and volume rendering) with power Doppler ultrasonography is shown. CONCLUSIONS: Three-dimensional power Doppler ultrasonography is an important adjunctive method that can be used to characterize normal vascular development and circulatory anomalies of the fetus.

Female↗

The evolving appearance of a congenital diaphragmatic hernia.

OBJECTIVE: The prenatal differentiation of a fetal congenital diaphragmatic hernia from other echogenic chest masses can be difficult. The implications of the leading diagnosis can greatly affect the neonatal prognosis. The cases presented illustrate how the primary diagnosis of a fetal chest mass can change during the course of gestation as the appearance of the chest mass evolves. METHODS: A descriptive analysis of 2 cases reviewed the importance of considering multiple causes of an echogenic chest mass. RESULTS: The sonographic features of a congenital diaphragmatic hernia that have been described in the literature were not always present at the time of initial evaluation. CONCLUSIONS: A congenital diaphragmatic hernia should be part of the differential diagnosis considered during consultation with parents whose fetus has an echogenic chest mass.

Adult↗

A diagnostic approach for the evaluation of spina bifida by three-dimensional ultrasonography.

OBJECTIVE: To describe a prenatal diagnostic method for evaluating spina bifida by three-dimensional ultrasonography. METHODS: Two- and three-dimensional ultrasonography were used to determine the extent of vertebral defects among fetuses with spina bifida. Spinal levels were independently counted from the most caudal thoracic vertebra with a rib (e.g., 12th thoracic rib). A virtual cutting plane was manipulated through a volume-rendered spine to generate optimal multiplanar views for this blinded analysis. Prenatal diagnosis was compared with a postnatal analysis of bony spine defects derived from radiographic films or magnetic resonance imaging. RESULTS: Nine fetuses were examined by two-dimensional ultrasonography (21.8 +/- 3.4 menstrual weeks) and three-dimensional ultrasonography (22.8 +/- 4.4 menstrual weeks). For two-dimensional ultrasonography, the spinal level agreed to within 1 vertebral segment in 6 of 9 infants. In contrast, three-dimensional ultrasonography agreed to within 1 vertebral segment in 8 of 9 infants. Three fetuses had vertebral defect levels on two-dimensional ultrasonography that were 1.5 to 2 segments away from postnatal findings. The same fetuses had results that were within 1 vertebral segment on three-dimensional ultrasonography. Volume rendering showed splayed vertebral pedicles and disrupted vertebrae. An intact meningeal sac was easily rendered in 5 of 9 subjects. CONCLUSIONS: Multiplanar views are generally more informative than rendered views for localizing bony defects of the fetal spine. The level of the defect on three-dimensional ultrasonography correlates well with those on two-dimensional ultrasonography and postnatal imaging studies. This approach may improve characterization of spina bifida by adding diagnostic information that is complementary to the initial assessment by two-dimensional ultrasonography.

Female↗

Three-dimensional ultrasonographic presentation of micrognathia.

OBJECTIVE: To present the variable appearance of micrognathia in fetuses by three-dimensional ultrasonography and to describe practical methods for analysis of these volume data. METHODS: Three-dimensional multiplanar imaging and surface-rendering techniques were used to show various syndromes and diagnostic approaches for the evaluation of fetal micrognathia. RESULTS: Nine cases of fetal micrognathia are presented. Orthogonal multiplanar views were used to obtain a midsagittal facial profile. Examples of micrognathia include 3 cases of Pierre Robin sequence, cerebrocostomandibular syndrome, Cornelia de Lange syndrome, and hypochondrogenesis. Diagnostic pitfalls for micrognathia are also shown. CONCLUSIONS: Three-dimensional multiplanar imaging increases the likelihood that a true midline sagittal view of the facial profile is being analyzed. Surface rendering provides another way to qualitatively evaluate the fetal chin from different viewing perspectives. Three-dimensional ultrasonographic methods are useful adjuncts to the preliminary diagnostic impression from two-dimensional ultrasonography.

Abnormalities, Multiple↗