PubMed Health⌕ Search

Biomedical subjects

Willem J L Suyker

Publications and source records attributed to Willem J L Suyker.

6 recordsLinked to original sources

S2 connector versus suture: distal coronary anastomosis remodeling, patency, and function in the pig.

BACKGROUND: Anastomotic connectors could be the key to less invasive bypass surgery, including endoscopic procedures, but equivalence to conventional suturing needs to be established. A novel distal coronary connector was tested pre-clinically for safety and efficacy in comparison to conventional suturing. METHODS AND RESULTS: Left internal thoracic to left anterior descending coronary artery bypasses were constructed off-pump in 35 pigs (73+/-8 kg). An intraluminal metal connector (S2AS) was used in 21 and conventional suturing in 14 animals. S2AS anastomosis construction was easier achieved in one-fourth of the conventional construction time (3.7+/-0.7 versus 16.5+/-2.6 minutes; P<0.001). Acute patency tended to be better (P=0.15). All anastomoses were evaluated intraoperatively, and subgroups at 90 and at 180 days. Patency was 100%. An effective remodeling response was observed in all groups, resulting in unobstructed anastomoses with excellent hemodynamic performance (fractional flow reserve > or = 0.93 at 180 days). At 6 months, the noncompliant connector was covered with stabilized neointima that was thinner than found on the suture line (0.10+/-0.04 versus 0.31+/-0.13 mm; P=0.01). The connector induced less lumen loss (-0.6+/-6.5 versus 21.6+/-19%; P=0.03). The initial side-to-side configuration had remodeled to an end-to-side shape as intended. CONCLUSIONS: In the porcine model, the connector rapidly and consistently produced high-quality anastomoses that fully met current standards on patency and function. Unconventional aspects like a noncompliant intraluminal ring and a side-to-side to end-to-side converted configuration did not interfere with favorable anastomosis remodeling. These findings shed a new light on the anatomical prerequisites for anastomosis patency.

Animals↗

Quality assessment of distal S(2)AS connector anastomosis by 13 MHz epicardial ultrasound.

OBJECTIVE: During application of a distal coronary bypass connector, we employed 13 MHz epicardial ultrasound to evaluate quantitative caliper measurements for vessel size matching and to assess anastomosis quality after connector deployment. METHODS: Two S(2)AS connector anastomoses were constructed on ex vivo pressure-perfused porcine hearts. Epicardial ultrasound measurements of the connector ring and anastomosis were compared to intravascular ultrasound measurement and cast dimensions. In 21 pigs, anastomotic sites with internal diameter of 2.25-3.0mm (internal mammary artery, IMA) and 1.8-2.2mm (left anterior descending coronary artery, LAD) were selected using external caliper and epicardial ultrasound measurements. Anastomoses were visualized and assessed intraoperatively (beating heart, n=21) and at 3 and 6 months' follow-up (explanted heart, n=10 each). RESULTS: Epicardial ultrasound underestimated connector dimension by < or =5% versus intravascular ultrasound and deviated < or =13% from cast dimensions for other anastomotic measurements. Caliper estimates of internal IMA and LAD diameter differed from ultrasound by -3+/-6% and -2+/-7% (mean+/-SD), respectively. Intraoperatively, the anastomotic orifice was flawless in all animals. It remained fully patent at 3 and 6 months by ultrasound, which was confirmed by histology. The connector to LAD percentage diameter stenosis changed from -12+/-5% intraoperatively to -1+/-7% at 3 months and from -5+/-6% intraoperatively to -16+/-13% at 6 months, in the growing pig model. CONCLUSIONS: In the pig, external caliper measurements provided a reliable quantitative estimate of inner graft and coronary diameter for connector size matching. Epicardial 13 MHz ultrasound is a promising method to assess coronary anastomosis quality even when connector metal is present.

Anastomosis, Surgical↗

Role of coronary collaterals in off-pump and on-pump coronary bypass surgery.

BACKGROUND: Collaterals limit infarct size, preserve viability, and reduce mortality in patients with acute myocardial infarction. In patients with stable coronary disease, collaterals are associated with less angina and ischemia during angioplasty and fewer ischemic events during follow-up. The role of collaterals has not been studied in patients undergoing off-pump or on-pump bypass surgery. METHODS AND RESULTS: The population consisted of the 281 patients randomized to off-pump or on-pump CABG in the Octopus Study. Collaterals were defined on the baseline angiogram with the Rentrop score and were present in 49% and 51% of the patients in the off-pump and on-pump group, respectively. Perioperative myocardial infarction was defined by a creatine kinase-MB to CK ratio >10% and occurred in 18.2% in the off-pump group and 32.5% in the on-pump group. The unadjusted OR of perioperative myocardial infarction in the presence of collaterals was 0.31 (95% CI 0.17 to 0.84) in the off-pump group and 1.06 (95% CI 0.29 to 3.85) in the on-pump group After adjustment for age, gender, hypertension, hypercholesterolemia, diabetes, multivessel disease, ventricular dysfunction, incomplete revascularization, and ischemic time, the OR was 0.34 (95% CI 0.14 to 0.84) in the off-pump group and 1.28 (95% CI 0.30 to 5.40) in the on-pump group, respectively. Kaplan-Meier estimates of event-free survival at 1 year were 87% in patients with and 69% in those without collaterals after off-pump CABG. These estimates were 66% and 63%, respectively, after on-pump CABG. CONCLUSIONS: Collaterals protect against perioperative myocardial infarction during off-pump surgery but not during on-pump surgery and are associated with a better 1-year event-free survival.

Aged↗

Stapled coronary anastomosis with minimal intraluminal artifact: The S2 Anastomotic System in the off-pump porcine model.

OBJECTIVE: A reliable, easy-to-use, 1-shot anastomotic device will significantly push the barrier for less invasive coronary bypass surgery. The current study was designed to test the safety, efficacy, and early patency of a novel distal anastomotic device. METHODS: The S2 Anastomotic System (iiTech BV, Amsterdam, The Netherlands) was used in 10 consecutive pigs (73 kg) on a mild antiplatelet regimen. In each animal, the device was used to create an internal thoracic artery to left anterior descending bypass on the beating heart. The anastomoses were evaluated intraoperatively (n = 10), at 2 days (n = 2), and at 5 weeks (n = 8) by functional flow measurements, postmortem angiography, and histomorphologic examination. RESULTS: In all pigs, the S2 Anastomotic System rapidly created successful anastomoses at the first attempt (graft loading and coronary ischemia time: 1.2 +/- 0.3 minutes and 3.0 +/- 0.6 minutes) on target vessels of 1.6 to 2 mm inner diameter. There were no technical failures or anastomotic leaks requiring additional sutures. Both intraoperatively and at the time of death, ischemically induced peak hyperemic flow responses demonstrated widely patent bypasses, which were confirmed by postmortem angiography (FitzGibbon grade A, n = 10) and macroscopic evaluation (anastomotic orifice: 2 mm). Histomorphologic evaluation showed a normal healing response with negligible neointima covering the connector and limited streamlining repair tissue formation between the staple-like elements of the connector. CONCLUSIONS: The S2 Anastomotic System consistently created automated, fast, and reliable internal thoracic to coronary artery anastomoses on the porcine beating heart with excellent graft patency and healing characteristics at the 5-week follow-up.

Anastomosis, Surgical↗

A comparison of on-pump and off-pump coronary bypass surgery in low-risk patients.

BACKGROUND: The performance of coronary bypass surgery without cardiopulmonary bypass ("off pump") may reduce perioperative morbidity and costs, but it is uncertain whether the outcome is similar to that involving the use of cardiopulmonary bypass ("on pump"). METHODS: In a multicenter, randomized trial, we randomly assigned 139 patients with predominantly single- or double-vessel coronary disease to on-pump surgery and 142 to off-pump surgery. Cardiac outcome and cost effectiveness were determined one year after surgery. The uncertainty surrounding the cost-effectiveness ratio (cost differences per quality-adjusted year of life gained) was addressed by bootstrapping. RESULTS: At one year, the rate of freedom from death, stroke, myocardial infarction, and coronary reintervention was 90.6 percent after on-pump surgery and 88.0 percent after off-pump surgery (absolute difference, 2.6 percent; 95 percent confidence interval, - 4.6 to 9.8). Graft patency in a randomized subgroup of patients was 93 percent after on-pump surgery and 91 percent after off-pump surgery (absolute difference, 2.0 percent; 95 percent confidence interval, - 6.5 to 10.4). On-pump surgery was associated with $1,839 in additional direct costs per patient ($14,908 vs. $13,069--a difference of 14.1 percent) and an increase in quality-adjusted years of life of 0.83 as compared with 0.82 (difference, 0.01 year; 95 percent confidence interval, - 0.03 to 0.04). Off-pump surgery was more cost effective than on-pump surgery in 95 percent of bootstrap estimates. CONCLUSIONS: In low-risk patients, there was no difference in cardiac outcome at one year between those who underwent on-pump bypass surgery and those who underwent off-pump surgery. Off-pump surgery was more cost effective.

Cardiopulmonary Bypass↗