PubMed Health⌕ Search

Biomedical subjects

William A Ivancic

Publications and source records attributed to William A Ivancic.

2 recordsLinked to original sources

Characterizing residue transfer efficiencies using a fluorescent imaging technique.

To reduce the uncertainty associated with current estimates of children's exposure to pesticides by dermal contact and indirect ingestion, residue transfer data are required. Prior to conducting exhaustive studies, a screening study to identify the important parameters for characterizing these transfers was designed. A fluorescence imaging system was developed (Ivancic et al., in press) to facilitate collection of surface residue transfer data for repeated contacts. Next, parameters that affect residue transfer from surface-to-skin, skin-to-other objects, and skin-to-mouth were evaluated using the imaging system and the fluorescent tracer riboflavin as a surrogate for pesticide residues. Riboflavin was applied as a residue to surfaces of interest. Controlled transfer experiments were conducted by varying contact parameters with each trial. The mass of a tracer transferred was measured and the contact surface area estimated using video imaging techniques. Parameters evaluated included: surface type, surface loading, contact motion, pressure, duration, and skin condition. Transfers both onto, and off of, the hand were measured. To efficiently identify parameter changes resulting in significant effects, the Youden ruggedness test was used to select the combination of parameters varied in each contact trial. In this way, more than one parameter could be varied at a time and the number of trials required was minimized. Results of this study showed that surface loading and skin condition (significant at alpha=0.05) are among the important parameters for characterizing residue transfers of riboflavin. Duration of contact within the time range investigated does not have a significant effect on transfer of this tracer. Results of this study demonstrate the potential for collecting dermal transfer data using the Ivancic et al. fluorescence imaging system and provide preliminary data to reduce uncertainty associated with estimating dermal exposures resulting from contact with residue-contaminated surfaces. These data will also aid in determining what additional residue transfer data should be collected and what type of microactivity data are needed to estimate dermal and indirect ingestion exposure to residues on household surfaces.

Administration, Cutaneous↗

Development and evaluation of a quantitative video-fluorescence imaging system and fluorescent tracer for measuring transfer of pesticide residues from surfaces to hands with repeated contacts.

A video imaging system and the associated quantification methods have been developed for measurement of the transfer of a fluorescent tracer from surfaces to hands. The highly fluorescent compound riboflavin (vitamin B2), which is also water soluble and non-toxic, was chosen as the tracer compound to simulate the transfer from surfaces to hands of pesticide residues deposited on carpeted and laminate surfaces of a residence. The system was designed around the unique properties of riboflavin. Excitation energy was centered near 440 nm (in the blue region of the visible spectrum); emitted energy was measured at 600 nm (in the red/orange region), well beyond the significant fluorescence peak maximum of natural skin. A video camera system with an image intensifier was interfaced to an image processing analysis software system. Quantification utilized chemometric techniques to account for the non-linearity of pixel detectivity and non-linear excitation strength. Method quantification and detection limits were approximately 0.1 and 0.02 micro g/cm(2), respectively. The relative error was approximately 100% at the quantification limit, but <20% at higher levels. Transfer of riboflavin to hands, resulting in dermal loadings in the range 0.1-2.0 micro g/cm(2), were measured with this system from surfaces whose loadings approximated the pesticide levels that occur in homes after broadcast application.

Calibration↗