Excess risk thresholds in ultrasound safety studies: statistical methods for data on occurrence and size of lesions.

Concerns about the safe use of clinical ultrasound (US) at diagnostic pressure levels (below a mechanical index, or MI, = 1.9) have stimulated considerable research in US risk assessment. The objective of the present study was to develop probability-based risk thresholds for US safety studies, to present statistical methods for estimating the thresholds and their standard errors and to compare these methods with the analysis based on a piecewise linear ("hockey stick") model. The excess risk at exposure level x > 0 was defined as the relative increase in the probability of a lesion at that level compared with the background probability of a lesion at exposure x = 0. The risk threshold was then defined as the exposure level at which the excess risk exceeded a specified level (e.g. 5% or 50%). Thus, given pressure-dependent estimates of the excess risk, the thresholds were estimated by solving the risk equation to obtain the pressure at which the target level of excess risk occurs. Threshold estimates of this type have been developed extensively in the literature for incidence (presence or absence) data. Only recently, however, have excess risk threshold estimates been derived for data in which lesion size (depth, surface area) is measured if present and a zero is recorded if the lesion is absent. Tobit regression was used to estimate pressure-dependent percentiles of the size distribution, and the excess risks were estimated from the tobit probability of a positive-valued response. The tobit model provides a well-established approach to modeling data constrained to be nonnegative. Solving the risk equation for the tobit model leads to risk threshold estimates that incorporate the information on size of observed lesions. Results using these probability-based risk estimates were compared with results for a piecewise linear ("hockey stick") model, which has also been used in the US safety literature, although it does not explicitly address the nonnegativity constraint in the sampling model. The comparisons were carried out for data from two previously published studies, from different laboratories, on US-induced lung hemorrhage. The thresholds derived from logistic regression of lesion occurrence and tobit regression of lesion size were quite consistent with each other and within sampling error. The hockey stick thresholds, defined as the exposure level at which the piecewise linear model for the probability of the expected size of a lesion bends upward, corresponded to quite different excess risk values for incidence (lesion occurrence) compared with size (lesion surface area or depth), although these methods have been developed previously for both types of data. The use of probability-based excess risk thresholds is recommended to obtain consistent incidence vs. size thresholds and to ensure that the thresholds are well-defined and interpretable independent of the details of the statistical model.

Animals↗

Differentiation and characterization of rat mammary fibroadenomas and 4T1 mouse carcinomas using quantitative ultrasound imaging.

Scatterer properties like the average effective scatterer diameter and acoustic concentration were determined in vivo using a quantitative ultrasound (QUS) technique from two tumor phenotypes grown in animal models. These tumor models included spontaneously occurring mammary fibroadenomas in rats and transplanted 4T1 mammary carcinomas in mice. The scatterer properties of average scatterer diameter and acoustic concentration were estimated using a Gaussian form factor from the backscattered ultrasound measured from both types of tumors. QUS images of the tumors were constructed utilizing estimated scatterer properties from regions in the tumors. The QUS images showed a clear distinction between the two types of tumors and a statistically significant difference existed between their estimated scatterer properties. The average scatterer diameter and acoustic concentration for the mammary fibroadenomas were estimated to be 105 +/- 25 microm and -15.6 +/- 5 dB(mm(-3)), respectively. The average scatterer diameter and acoustic concentration for the carcinomas was estimated to be 28 +/- 4.6 microm and 10.6 +/- 6.9 dB(mm(-3)), respectively. The distinctions in the scattering properties are clearly seen in the QUS images of the tumors and indicate that QUS imaging can be useful in differentiating between different types of mammary tumors.

Algorithms↗

Overdetermined least-squares aberration estimates using common-midpoint signals.

As medical ultrasound imaging moves to larger apertures and higher frequencies, tissue sound-speed variations continue to limit resolution. In geophysical imaging, a standard approach for estimating near-surface aberrating delays is to analyze the time shifts between common-midpoint signals. This requires complete data-echoes from every source/receiver pair in the array. Unfocused common-midpoint signals remain highly correlated in the presence of delay aberrations; there is also tremendous redundancy in the data. In medical ultrasound, this technique has been impaired by the wide-angle, random-scattering nature of tissue. This has made it difficult to estimate azimuth-dependent aberration profiles or to harness the full redundancy in the complete data. Prefiltering the data with two-dimensional fan filters mitigates these problems, permitting highly overdetermined, least-squares solutions for the aberration profiles at many steering angles. In experiments with a tissue-mimicking phantom target and silicone rubber aberrators at nonzero stand-off distances from a one-dimensional phased array, this overdetermined, fan-filtering algorithm significantly outperformed other phase-screen algorithms based on nearest-neighbor cross-correlation, speckle brightness maximization, and common-midpoint signal analysis. Our results imply that there is still progress to be made in imaging with single-valued focusing operators. It also appears that the signal-to-noise penalty for using complete data sets is partially compensated by the overdetermined nature of the problem.

Algorithms↗

Effect of contrast agent on the incidence and magnitude of ultrasound-induced lung hemorrhage in rats.

OBJECTIVE: To test the hypothesis that inertial cavitation in the vasculature of the lung is not the physical mechanism responsible for ultrasound-induced lung hemorrhage. METHODS: A factorial design was used to study the effects of two types of injected agents (IA; 0.25 ml per rat of saline or Optison given intravenously) and two levels of pulsed ultrasound exposure (UE; in situ peak rarefactional pressures of 2.74 and 5.86 MPa; respective mechanical indices of 1.02 and 2.14) on the incidence and size of lung lesions. Ten 10-to-11-week-old Sprague-Dawley rats were exposed to pulsed ultrasound at each of the four combinations of IA and UE at a center frequency of 3.1 MHz, exposure duration of 10 s, pulse repetition frequency of 1,000 Hz and pulse duration of 1.2 micros. In addition, nine rats served as shams in which no lung hemorrhage occurred. RESULTS: Rats administered contrast agent prior to exposure did not have an increase in lesion occurrence or size compared to rats that received saline with no contrast agent. CONCLUSIONS: These results provide further evidence that the mechanism for production of lung hemorrhage is not inertial cavitation.

Albumins↗

Performance of time- and frequency-domain binaural beamformers based on recorded signals from real rooms.

Extraction of a target sound source amidst multiple interfering sound sources is difficult when there are fewer sensors than sources, as is the case for human listeners in the classic cocktail-party situation. This study compares the signal extraction performance of five algorithms using recordings of speech sources made with three different two-microphone arrays in three rooms of varying reverberation time. Test signals, consisting of two to five speech sources, were constructed for each room and array. The signals were processed with each algorithm, and the signal extraction performance was quantified by calculating the signal-to-noise ratio of the output. A frequency-domain minimum-variance distortionless-response beamformer outperformed the time-domain based Frost beamformer and generalized sidelobe canceler for all tests with two or more interfering sound sources, and performed comparably or better than the time-domain algorithms for tests with one interfering sound source. The frequency-domain minimum-variance algorithm offered performance comparable to that of the Peissig-Kollmeier binaural frequency-domain algorithm, but with much less distortion of the target signal. Comparisons were also made to a simple beamformer. In addition, computer simulations illustrate that, when processing speech signals, the chosen implementation of the frequency-domain minimum-variance technique adapts more quickly and accurately than time-domain techniques.

Algorithms↗

Defining optimal axial and lateral resolution for estimating scatterer properties from volumes using ultrasound backscatter.

The rf signals used to construct conventional ultrasound B-mode images contain frequency-dependent information that can be examined through the backscattered power spectrum. Typically, the backscattered power spectrum is calculated from a region of interest (ROI) within some larger volume. The dimensions of the ROI are defined axially by the spatial length corresponding to the time gate and laterally by the number of scan lines included in the ROI. Averaging the backscattered power spectra from several independent scan lines can reduce the presence of noise caused by electronics and by the random scatterer spacings, but also decreases the lateral resolution of the interrogation region. Furthermore, larger axial gate lengths can be used to reduce the effects of noise and improve the precision and accuracy of scatterer property estimates but also decreases the axial resolution. A trade-off exists between the size of the ROI (the number of scan lines used, the separation distance between each scan line, the axial gate length) and the accuracy and precision of scatterer property estimates. A series of simulations and measurements from physical phantoms were employed to examine these trade-offs. The simulations and phantom measurements indicated the optimal lateral and axial sizes of the ROI, where estimate accuracy and precision were better than 10% and 5%, respectively, occurred at 4 to 5 beamwidths laterally and 15 to 20 spatial pulse lengths axially.

Animals↗

Scatterer size estimation in pulse-echo ultrasound using focused sources: theoretical approximations and simulation analysis.

The speckle in ultrasound images has long been thought to contain information related to the tissue microstructure. Many different investigators have analyzed the frequency characteristics of the backscattered signals to estimate the scatterer acoustic concentration and size. Previous work has been mostly restricted to unfocused or weakly focused ultrasound sources, thus limiting its implementation with diagnostically relevant fields. Herein, we derive equations capable of estimating the size of a scatterer for any reasonably focused source provided that the velocity potential field in the focal region can be approximated as a three-dimensional Gaussian beam, scatterers are a sufficient distance from the source, and the field is approximately constant across the scatterer. The calculations show that, when estimating the scatterer size, correcting for focusing requires a generalized attenuation-compensation function that includes both attenuation and focusing along the beam axis. The Gaussian approximation is validated by comparing the ideal velocity potential field for three spherically focused sources with f-numbers of 1, 2, and 4 to the Gaussian approximation for frequencies from 2 to 14 MHz. The theoretical derivations are evaluated by simulating the backscatter by using spherically focused sources (f-numbers of 1, 2, and 4) adjacent to attenuating media (0.05 to 1 dB/cm/MHz) that contain scatterers with Gaussian impedance distributions. The generalized attenuation-compensation function yielded results accurate to 7.2% while the traditional attenuation-compensation functions that neglected focusing had errors as high as 103%.

Animals↗

Scatterer size estimation in pulse-echo ultrasound using focused sources: calibration measurements and phantom experiments.

In a companion paper [T. A. Bigelow and W. D. O'Brien Jr., J. Acoust. Soc. Am. 116, 578 (2004)], theory, supported by simulations, showed that accurate scatterer size estimates could be obtained using highly focused sources provided that the derived generalized attenuation-compensation function was used and the velocity potential field near the focus could be approximated as a three-dimensional Gaussian. Herein, the theory is further evaluated via experimental studies. A calibration technique is developed to find the necessary equivalent Gaussian dimensions for a focused source using reflections obtained from a rigid plane scanned through the focus. Then, the theoretical analysis of focused sources is validated experimentally using three spherically focused ultrasound transducers to estimate the radius of glass beads imbedded in tissue mimicking phantoms. Both the impact of focusing (f/1, f/2, and f/4) and the effect of scatterer type (comparing glass bead results to simulation results that used scatterers with Gaussian impedance distributions) were tested. The simulated differences agree with the measured differences to within 2.5% provided that the comparison is made between the same scatterer type and sources with the same equivalent Gaussian dimensions. The improvement provided by the generalized attenuation-compensation function is greatly influenced by the type of scatterer whose size is being estimated and decreases as the wavelength dependence of the Gaussian depth of focus is reduced.

Calibration↗

Improved scatterer property estimates from ultrasound backscatter for small gate lengths using a gate-edge correction factor.

Backscattered rf signals used to construct conventional ultrasound B-mode images contain frequency-dependent information that can be examined through the backscattered power spectrum. The backscattered power spectrum is found by taking the magnitude squared of the Fourier transform of a gated time segment corresponding to a region in the scattering volume. When a time segment is gated, the edges of the gated regions change the frequency content of the backscattered power spectrum due to truncating of the waveform. Tapered windows, like the Hanning window, and longer gate lengths reduce the relative contribution of the gate-edge effects. A new gate-edge correction factor was developed that partially accounted for the edge effects. The gate-edge correction factor gave more accurate estimates of scatterer properties at small gate lengths compared to conventional windowing functions. The gate-edge correction factor gave estimates of scatterer properties within 5% of actual values at very small gate lengths (less than 5 spatial pulse lengths) in both simulations and from measurements on glass-bead phantoms. While the gate-edge correction factor gave higher accuracy of estimates at smaller gate lengths, the precision of estimates was not improved at small gate lengths over conventional windowing functions.

Algorithms↗

Threshold estimates and superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse duration.

The study objective was to estimate the pressure threshold (ED(05), effective dose, or in situ peak rarefactional pressure associated with 5% probability of lesions) of ultrasound (US)-induced lung hemorrhage as a function of pulse duration (PD) in adult rats. A total of 220 10- to 11-week-old 250-g female Sprague-Dawley rats (Harlan) were randomly divided into 20 ultrasonic exposure groups (10 rats/group) and one sham group (20 rats). The 20 ultrasonic exposure groups (2.8-MHz; 10-s exposure duration; 1-kHz PRF; -6-dB pulse-echo focal beam width of 470 microm) were divided into four PD groups (1.3, 4.4, 8.2 and 11.6 micros) and, for each PD group, there were five in situ peak rarefactional pressures (range between 4 and 9 MPa). Rats were weighed, anesthetized, depilated, exposed, and euthanized under anesthesia. The left lung was removed and scored for the occurrence of hemorrhage. If hemorrhage was present, the lesion surface area and depth were measured. Individuals involved in animal handling, exposure and lesion scoring were "blinded" to the exposure conditions. Logistic regression analysis was used to examine the dependence of the lesion occurrences, and Gaussian tobit regression analysis was used to examine the dependence of the lesion surface areas and depths on in situ peak rarefactional pressure and PD. Threshold results are reported in terms of ED(05). For PDs of 1.3, 4.4, 8.2 and 11.6 micros, respectively, lesion occurrence ED(05)s were 3.1, 2.8, 2.3 and 2.0 MPa with standard errors around 0.6 MPa. Lesion size ED(05)s showed similar values. A mechanical index (MI) of 1.9, the US Food and Drug Administration (FDA) regulatory limit of diagnostic US equipment, is equivalent to the adult rat's in situ peak rarefactional pressure of 4.0 MPa. PDs of 8.2 and 11.6 micros had ED(05)s more than 2 standard errors below 4.0 MPa, indicating that the ED(05)s of these two PDs are statistically significantly different from 4.0 MPa. The ED(05) threshold levels for a PD of 1.3 micros are consistent with previous US-induced lung hemorrhage studies. As the PD increases, the ED(05) levels decrease, suggesting greater likelihood of lung damage as the PD increases. All of the ED(05)s are less than the FDA limit.

Animals↗

Superthreshold behavior and threshold estimation of ultrasound-induced lung hemorrhage in pigs: role of age dependency.

Age-dependent threshold and superthreshold behavior of ultrasound-induced lung hemorrhage were investigated with 116 2.1 +/- 0.3-kg neonate crossbred pigs (4.9 +/- 1.6 days old), 103 10 +/- 1.1-kg crossbred pigs (39 +/-5 days old), and 104 20+/-1.2-kg crossbred pigs (58 +/- 5 days old). Exposure conditions were: 3.1 MHz, 10-s exposure duration, 1-kHz pulse repetition frequency (PRF), and 1.2-micros pulse duration. The in situ (at the pleural surface) peak rarefactional pressure ranged between 2.2 and 10.4 MPa with either eight or nine acoustic pressure groups for each of the three pig ages (12 pigs/exposure group) plus sham exposed pigs. There were no lesions in the shams. Pigs were exposed bilaterally with the order of exposure (left then right lung, or right then left lung) and acoustic pressure both randomized. Pig age was not randomized. Individuals involved in animal handling, exposure, and lesion scoring were blinded to the exposure condition. Logistic regression analysis was used to examine the dependence of the lesion incidence rates on in situ peak rarefactional pressure, left versus right lung exposure, order of exposure (first versus second), and age in three age groups. Likewise, lesion depth and lesion root surface area were analyzed using Gaussian tobit regression analysis. A significant threshold effect on lesion occurrence was observed as a function of age; younger pigs were less susceptible to lung damage given equivalent in situ exposure. Overall, the oldest pigs had a significantly lower threshold (2.87 +/- 0.29 MPa) than middle-aged pigs (5.83 +/- 0.52 MPa). The oldest pigs also had a lower threshold than neonate pigs (3.60 +/- 0.44 MPa). Also, an unexpected result was observed. The ultrasound exposures were bilateral, and the threshold results reported above were based on the lung that was first exposed. After the first lung was exposed, the pig was turned over and the other lung was exposed to the same acoustic pressure. There was a significant decrease (greater than the confidence limits) in occurrence thresholds: 3.60 to 2.68, 5.83 to 2.97, and 2.87 to 1.16 MPa for neonates, middle-aged, and oldest pigs, respectively, in the second lung exposed. Thus, a subtle effect in lung physiology resulted in a major effect on lesion thresholds.

Aging↗

Experimental spatial sampling study of the real-time ultrasonic pulse-echo BAI-mode imaging technique.

The ultrasonic pulse-echo backscattered amplitude integral (BAI)-mode imaging technique has been developed to inspect the seal integrity of hermetically sealed, flexible food packages. With a focused 17.3-MHz transducer acquiring radio frequency (RF) echo data in a static rectilinear stop-and-go pattern, this technique was able to reliably detect channel defects as small as 38 microm in diameter and occasionally detect 6-microm-diameter channels. This contribution presents our experimental spatial sampling study of the BAI-mode imaging technique with a continuous zigzag scanning protocol that simulates a real-time production line inspection method in continuous motion. Two transducers (f/2 17.3 MHz and f/3 20.3 MHz) were used to acquire RF echo data in a zigzag raster pattern from plastic film samples bearing rectilinear point reflector arrays of varying grid spacings. The average BAI-value difference (deltaBAI) between defective and intact regions and the contrast-to-noise ratio (CNR) were used to assess image quality as a function of three spatial sampling variables: transducer spatial scanning step size, array sample grid spacing, and transducer -6-dB pulse-echo focal beam spot size. For a given grid size, the deltaBAI and CNR degraded as scanning step size in each spatial dimension increased. There is an engineering trade-off between the BAI-mode image quality and the transducer spatial sampling. The optimal spatial sampling step size has been identified to be between one and two times the -6-dB pulse-echo focal beam lateral diameter.

Algorithms↗

Effect of pulse polarity and energy on ultrasound-induced lung hemorrhage in adult rats.

The objective of this study was to further assess the role of inertial cavitation in ultrasound-induced lung hemorrhage by examining the effect of pulse polarity at a common in situ (at the lung surface) peak rarefactional pressure [pr(in situ)] and at a common in situ pulse intensity integral (PII(in situ)). A total of 60 rats was divided into three experimental groups of 20 animals per group and randomly exposed to pulsed ultrasound. The groups were exposed as follows: Group 1 to 0 degree polarity pulses (compression followed by rarefraction) at a pr(in situ) of 3.48 MPa and a PII(in situ) of 4.78 Ws/m2, group 2 to 180 degree polarity pulses (rarefraction followed by compression) at a pr(in situ) of 3.72 MPa and a PII(in situ) of 2.55 Ws/m2, and group 3 to 180 degree polarity pulses at a pr(in situ) of 4.97 MPa and a PII(in situ) of 4.79 Ws/m2. For all experimental groups, the frequency was 2.46 MHz, the exposure duration was 240 s, the pulse repetition frequency was 2.5 kHz, and the pulse duration was 0.42 micros. Six sham animals were also randomly distributed among the experimental animals. The lesion surface area and depth were determined for each rat as well as lesion occurrence (percentage of rats with lesions) per group. It was found that lesion occurrence and size correlated better with PII(in situ) than with pr(in situ), suggesting that a mechanism other than inertial cavitation was responsible for the damage.

Animals↗

Blind estimation of reverberation time.

The reverberation time (RT) is an important parameter for characterizing the quality of an auditory space. Sounds in reverberant environments are subject to coloration. This affects speech intelligibility and sound localization. Many state-of-the-art audio signal processing algorithms, for example in hearing-aids and telephony, are expected to have the ability to characterize the listening environment, and turn on an appropriate processing strategy accordingly. Thus, a method for characterization of room RT based on passively received microphone signals represents an important enabling technology. Current RT estimators, such as Schroeder's method, depend on a controlled sound source, and thus cannot produce an online, blind RT estimate. Here, a method for estimating RT without prior knowledge of sound sources or room geometry is presented. The diffusive tail of reverberation was modeled as an exponentially damped Gaussian white noise process. The time-constant of the decay, which provided a measure of the RT, was estimated using a maximum-likelihood procedure. The estimates were obtained continuously, and an order-statistics filter was used to extract the most likely RT from the accumulated estimates. The procedure was illustrated for connected speech. Results obtained for simulated and real room data are in good agreement with the real RT values.

Acoustics↗

Impedance measurements of ex vivo rat lung at different volumes of inflation.

A previous study [J. Acoust. Soc. Am. 111, 1102-1109 (2002)] showed that the occurrence of ultrasonically induced lung hemorrhage in rats was directly correlated to the level of lung inflation. In that study, it was hypothesized that the lung could be modeled as two components consisting of air and parenchyma (contiguous tissue [pleura and septa]). The speed of sound and lung impedance would then depend on the fractional volume of air in the lung. According to that model, an inflated lung should act like a pressure-release surface for sound incident from tissue onto a tissue-lung boundary. A deflated lung containing less air should allow more acoustic energy into the lung tissue because the impedance was more closely matched to the contiguous tissues. In the study reported herein, a measurement technique was devised to calculate the impedance of seven rat lungs, ex vivo, under deflation (atmospheric pressure) and three volumes of inflation pressure (7-cm H2O, 10-cm H2O, and 15-cm H2O). Lungs were dissected from rats and immediately scanned in a tank of degassed 37 degrees C water. The frequency-dependent acoustic pressure reflection coefficient was measured over a frequency range of 3.5 to 10 MHz. From the reflection coefficient, the frequency-dependent lung impedance was calculated with values ranging from an average of 1 Mrayls in deflated lungs to 0.2 Mrayls for fully inflated lungs. Lung impedance calculations showed that deflated lungs had an impedance closer to water (1.52 Mrayls) than inflated lungs. At all volumes of inflation, the lungs acted as pressure-release surfaces relative to the water. The average of the four lung impedance values (deflated, 7-cm H2O, 10-cm H2O, and 15-cm H2O) at each level of inflation was statistically different (p<0.0001).

Acoustic Impedance Tests↗

Efficient three-dimensional imaging from a small cylindrical aperture.

Small-diameter cylindrical imaging platforms, such as those being considered in the development of in vivo ultrasonic microprobes, pose unique image formation challenges. The curved apertures they provide are incompatible with many of the commonly used frequency-domain synthetic aperture imaging algorithms. At the same time, their frequently small diameters place limits on the available aperture and the angular resolution that may be achieved. We obtain a three-dimensional, frequency-domain imaging algorithm for this geometry by making suitable approximations to the point spread function for wave propagation in cylindrical coordinates and obtaining its Fourier transform by analogy with the equivalent problem in Cartesian coordinates. For the most effective use of aperture, we propose using a focused transducer to place a virtual source a short distance from the probe. The focus is treated as a diverging source by the imaging algorithm, which then forms images on deeper cylindrical shells. This approach retains the simplicity and potential angular resolution of a single element, yet permits full use of the available probe aperture and a higher energy output. Computer simulations and experimental results using wire targets show that this imaging technique attains the resolution limit dictated by the operating wavelength and the transducer characteristics.

Computer Simulation↗

Attenuation coefficient and propagation speed estimates of rat and pig intercostal tissue as a function of temperature.

Attenuation coefficient and propagation speed of intercostal tissues were estimated as functions of temperature (22, 30, and 37 degrees C) from fresh chest walls from eight 10- to 11-week-old female Sprague-Dawley (SD) rats, eight 21- to 24-week-old female Long-Evans (LE) rats, and ten 6- to 10-week-old mixed sex Yorkshire (York) pigs. The primary purpose of the study was to estimate the temperature dependence of the intercostal tissue's attenuation coefficient so that accurate estimates of the in situ (at the pleural surface) acoustic pressure levels could be made for our ultrasound-induced lung hemorrhage studies. The attenuation coefficient of intercostal tissue for both species was independent of the temperature at the discrete frequencies of 3.1 MHz (-0.0076, 0.0065, and 0.016 dB/cm/degrees C for SD rats, LE rats, and York pigs, respectively) and 6.2 MHz (-0.015, 0.014, and 0.014 dB/cm/degrees C for SD rats, LE rats, and York pigs, respectively). However, the temperature-dependent regressions yielded a significant temperature dependency of the intercostal tissue attenuation coefficients in SD and LE rats (over the 3.1 to 9.6 MHz frequency range); there was no temperature dependency in York pigs (over the 3.1 to 8.6 MHz frequency range). There was no significant temperature dependency of the intercostal tissue propagation speed in SD rats; there was a temperature dependency in LE rats and York pigs (-0.59, -1.6, and -2.9 m/s/degrees C for SD rats, LE rats, and York pigs, respectively). Even though the attenuation coefficient's temperature dependency was significant from the linear regression functions, the differences were not very great (-0.040 to -0.13, 0.011 to 0.18, and 0.055 to 0.10 dB/cm/degrees C for SD rats, LE rats, and York pigs, respectively, over the data frequency range). These findings suggest that it is not necessary to determine the attenuation coefficient of intercostal tissue at body temperature (37 degrees C), but rather it is sufficient to determine the attenuation coefficient at room temperature (22 degrees C), a much easier experimental procedure.

Adipose Tissue↗

Attenuation coefficient and propagation speed estimates of intercostal tissue as a function of pig age.

Attention coefficient and propagation speed of intercostal tissues were estimated from chest walls removed postmortem (pm) from 15 5.3+/-2.3-day-old, 19 31+/-6-day-old, and 15 61+/-3-day-old crossbred pigs. These ultrasonic propagation properties were determined from measurements through the intercostal tissues, from the surface of the skin to the parietal pleura. The chest walls were placed in a 0.9% sodium chloride solution, sealed in freezer bags, and stored at -15 degrees C prior to measurements. When evaluated, chest-wall storage time ranged between 1 and 477 days pm. All chest walls were allowed to equilibrate to 22 degrees C in a water bath prior to evaluation. There was an age dependency of the intercostal tissue propagation speed, with the speed increasing with increasing age. The attenuation coefficient of intercostal tissue was shown to be independent of the age of the pig at the discrete frequencies of 3.1 and 6.2 MHz. For pig intercostal tissues, the estimated attenuation coefficient over the 3.1-9.2 MHz frequency range was A = 1.94f(0.90) where A is in decibels per centimeter (dB/cm) and f is the ultrasonic frequency in megahertz. In order to determine if there was an effect of storage time pm on estimates of attenuation coefficient, a second experiment was conducted. Five of the youngest pig chest walls measured on day 1 pm in the first experiment were stored at 4 degrees C prior to the first evaluation then stored at -15 degrees C before being measured again at 108 days pm. There was no difference in the estimated intercostal tissue attenuation coefficient as a function of storage time pm.

Adipose Tissue↗