Approach to 3-d ultrasound high resolution imaging for mechanically moving large-aperture transducer based upon Fourier transform.

A new three-dimensional (3-D) acoustic image formation technique is proposed that is based on the transmission of wide bandwidth pulse signals and the application of the 3-D fast Fourier transform. A solution to the Helmholz wave equation has been obtained using the Born approximation. The solution contains analytical expressions for the spatial spectra of the transmit and receive radiation patterns for transducers of various geometries with lenses of fixed focal distances. It has been shown that the proposed algorithms allow for radiation patterns with constant widths at depths both behind and in front of the focal point, starting practically from the plane of the transducer. The theoretical and experimental investigations and computer simulation for both spherical and rectangular transducer shapes have been performed. The results were used to estimate the beamwidths and the side lobe levels. A variant of the linear array has been studied for cylindrical lens of a fixed focal distance moving in a lateral direction. It has been shown that, in this case, a high resolution (of the order of a few wavelengths) can be achieved along all three Cartesian coordinates at a very high scanning velocity. The influence of the moving scatterers' velocity in inhomogeneous medium on the spatial radiation pattern characteristics has been estimated.

Algorithms↗

Ultrasound-induced lung hemorrhage: role of acoustic boundary conditions at the pleural surface.

In a previous study [J. Acoust. Soc. Am. 108, 1290 (2000)] the acoustic impedance difference between intercostal tissue and lung was evaluated as a possible explanation for the enhanced lung damage with increased hydrostatic pressure, but the hydrostatic-pressure-dependent impedance difference alone could not explain the enhanced occurrence of hemorrhage. In that study, it was hypothesized that the animal's breathing pattern might be altered as a function of hydrostatic pressure, which in turn might affect the volume of air inspired and expired. The acoustic impedance difference between intercostal tissue and lung would be affected with altered lung inflation, thus altering the acoustic boundary conditions. In this study, 12 rats were exposed to 3 volumes of lung inflation (inflated: approximately tidal volume; half-deflated: half-tidal volume; deflated: lung volume at functional residual capacity), 6 rats at 8.6-MPa in situ peak rarefactional pressure (MI of 3.1) and 6 rats at 16-MPa in situ peak rarefactional pressure (MI of 5.8). Respiration was chemically inhibited and a ventilator was used to control lung volume and respiratory frequency. Superthreshold ultrasound exposures of the lungs were used (3.1-MHz, 1000-Hz PRF, 1.3-micros pulse duration, 10-s exposure duration) to produce lesions. Deflated lungs were more easily damaged than half-deflated lungs, and half-deflated lungs were more easily damaged than inflated lungs. In fact, there were no lesions observed in inflated lungs in any of the rats. The acoustic impedance difference between intercostal tissue and lung is much less for the deflated lung condition, suggesting that the extent of lung damage is related to the amount of acoustic energy that is propagated across the pleural surface boundary.

Acoustics↗

Frequency-dependent attenuation-compensation functions for ultrasonic signals backscattered from random media.

Estimations of scattering parameters, such as average scatterer diameter, from rf signals backscattered from random media (tissues) are made from the frequency dependence of the rf signal. The frequency dependence of the rf signal backscattered from the medium is seen in the normalized power spectrum. The normalized power spectrum is found by taking the squared magnitude of the Fourier transform of the rf signal gated over a region of interest and dividing by some reference spectrum. If the medium has a frequency-dependent attenuation then the shape of the normalized power spectrum will be affected by the frequency-dependent attenuation and the time duration of the gated signal. Not accounting for the frequency-dependent attenuation leads to poor estimations of scatterer parameters. Larger attenuation and longer time gates give poorer estimates of scatterer parameters without attenuation compensation. Several attenuation-compensation functions have been used to account for the attenuation losses to the normalized power spectrum. A new attenuation-compensation function is proposed and compared with the other attenuation-compensation routines. The new attenuation-compensation function is shown to give improved estimates over previous attenuation-compensation functions for scatterers that follow a Gaussian form factor.

Humans↗

Characterization of tissue microstructure using ultrasonic backscatter: theory and technique for optimization using a Gaussian form factor.

Characterization of tissue microstructure through ultrasonic backscatter is hypothesized to aid in detection and classification of diseased tissues. Radio frequency signals backscattered from tissues can be modeled according to the assumed shape, size, and distribution of scatterers in tissues. Power spectra of rf backscattered signals describe the frequency dependence of scatterers. Experimental measurements of ultrasonic backscatter from spontaneous mammary tumors in rats are obtained over the frequency range of 4 to 12 MHz. The power spectra measured from rat tumors are compared to theoretical power spectra derived from a 3D spatial autocorrelation function assuming a Gaussian distribution. Independent values of average scatterer diameter and acoustic concentration are obtained by approximating the measured power spectrum with a best-fit line. Enhanced B-mode images are made of the rat tumors and surrounding tissues with superimposed regions of interest quantified by estimated average scatterer sizes and acoustic concentrations. Scattering properties estimated inside the tumors and in surrounding tissues are shown to be distinct. Overall, estimates showed a 44.8% increase of average scatterer diameter inside the tumor as compared to tissues outside the tumor. With the exception of one rat, all estimates of the scatterers' average acoustic concentration inside the tumor were less than outside the tumors.

Animals↗

Method of improved scatterer size estimation and application to parametric imaging using ultrasound.

The frequency dependence of RF signals backscattered from random media (tissues) has been used to describe the microstructure of the media. The frequency dependence of the backscattered RF signal is seen in the power spectrum. Estimates of scatterer properties (average scatterer size) from an interrogated medium are made by minimizing the average squared deviation (MASD) between the measured power spectrum and a theoretical power spectrum over an analysis bandwidth. Estimates of the scatterer properties become increasingly inaccurate as the average signal to noise ratio (SNR) over the analysis bandwidth becomes smaller. Some frequency components in the analysis bandwidth of the measured power spectrum will have smaller SNR than other frequency components. The accuracy of estimates can be improved by weighting the frequency components that have the smallest SNR less than the frequencies with the largest SNR in the MASD. A weighting function is devised that minimizes the noise effects on the estimates of the average scatterer sizes. Simulations and phantom experiments are conducted that show the weighting function gives improved estimates in an attenuating medium. The weighting function is applied to parametric images using scatterer size estimates of a rat that had developed a spontaneous mammary tumor.

Animals↗

Volumetric imaging with an amplitude-steered array.

Volumetric acoustic imaging is desirable for the visualization of underwater objects and structures; however, the implementation of a volumetric imaging system is difficult due to the high channel count of a fully populated two-dimensional array. Recently, a linear amplitude-steered array with a reduced electronics requirement was presented, which is capable of collecting a two-dimensional set of data with a single transmit pulse. In this study, we demonstrate the use of the linear amplitude-steered array and associated image formation algorithms for collecting and displaying volumetric data; that is, proof of principle of the amplitude-steering concept and the associated image formation algorithms is demonstrated. Range and vertical position are obtained by taking advantage of the frequency separation of a vertical linear amplitude-steered array. The third dimension of data is obtained by rotating the array such that the mainlobe is mechanically steered in azimuth. Data are collected in a water tank at the Pennsylvania State University Applied Research Laboratory for two targets: a ladder and three pipes. These data are the first experimental data collected with an amplitude-steered array for the purposes of imaging. The array is 10 cm in diameter and is operated in the frequency range of 80 to 304 kHz. Although the array is small for high-resolution imaging at these frequencies, the rungs of the ladder are recognizable in the images. The three pipes are difficult to discern in two of the projection images; however, the pipes separated in range are clear in the image showing vertical position versus range. The imaging concept is demonstrated on measured data, and the simulations agree well with the experimental results.

Journal Article↗

A high frequency amplitude-steered array for real-time volumetric imaging.

Real-time three-dimensional acoustic imaging is difficult in water or tissue because of the slow speed of sound in these media. Conventional pulse-echo data collection, which uses at least one transmit pulse per line in the image, does not allow for the real-time update of a volume of data at practical ranges. Recently, a linear amplitude-steered array was presented that allows the collection of a plane of data with a single transmit pulse by spatially separating frequencies in the lateral direction. Later, by using a linear array with frequency separation in the vertical direction and rotating the array in the horizontal direction, volumetric data were collected with a small number of transmit pulses. By expanding the linear array to a two-dimensional array, data can now be collected for volumetric imaging in real time. In this study, the amplitude-steered array at the heart of a real-time volumetric sonar imaging system is described, giving the design of the array and describing how data are collected and processed to form images. An analysis of lateral resolution in the vertical and horizontal directions shows that resolution is improved in the direction of frequency separation over systems that use a broad transmit beam. Images from simulated data are presented.

Journal Article↗

Parametric imaging of rat mammary tumors in vivo for the purposes of tissue characterization.

OBJECTIVE: To estimate the average scatterer properties from ultrasonic backscatter in tissues for evaluating differences between neoplastic and healthy tissues. METHODS: Parametric images of 8 retired breeder rats in which spontaneous mammary tumors had developed were created by superimposing color-coded pixels related to the estimated average scatterer properties on conventional gray scale B-mode images. RESULTS: The images showed a distinct difference between the tumors and surrounding healthy tissues. Analysis of the average scatterer diameters and acoustic concentrations showed a statistically significant difference (P < .05) between estimates inside and outside the tumors for most of the cases. Scatterer sizes inside the tumors were on average 30% larger than scatterer sizes in surrounding normal tissues. A feature analysis plot showed that there was a distinct difference between results obtained inside and outside the tumors. CONCLUSIONS: Parametric imaging that uses estimates of scatterer properties in tissues may lead to detection and characterization (diagnosis) of diseased tissues on conventional sonographic scanning systems.

Acoustics↗

Arrhythmias in rat hearts exposed to pulsed ultrasound after intravenous injection of a contrast agent.

OBJECTIVE: To develop an animal model suitable for characterizing electrocardiographic arrhythmias in hearts exposed to ultrasound after injection of a microbubble contrast agent. METHODS: Conduction complex and heart lesion data were recorded from 20 rats that received intravenous injections of 0.25 mL of a contrast agent and were exposed to pulsed ultrasound (frequency, 3.1 MHz; pulse duration, 1.3 microseconds; pulse repetition frequency, 1700 Hz; and in situ peak rarefactional pressure, 15.9 MPa). The volume of the contrast agent based on body weight and the mechanical index (ultrasonic pressure) exceeded those used in echocardiography by 14 to 345 and 3 to 29 times, respectively. RESULTS: Premature atrial complexes, premature ventricular complexes, or polymorphic ventricular tachycardia occurred in 10 rats. When ultrasound exposure was halted, arrhythmias ceased but reoccurred in 4 of the 10 rats when exposure resumed. Myocardial degeneration identified by histochemical staining (hematoxylin-basic fuchsinpicric acid) was observed in 16 rats; however, only 10 rats had arrhythmias. There was no significant difference in the amount of histochemical staining in hearts from rats with arrhythmias when compared with rats without arrhythmias. CONCLUSIONS: An animal model suitable for characterizing electrocardiographic arrhythmias in rat hearts exposed to ultrasound after injection of a microbubble contrast agent was developed. Because arrhythmias were induced principally when the contrast agent interacted with ultrasound during exposure, the presence of myocardial degeneration alone was not a sufficient explanation for ectopic electrical activity. Under these extreme exposure conditions, the data suggest that pulsed ultrasound through its biomechanical interactions with contrast agents has the potential to induce arrhythmias.

Albumins↗

Experimental evaluation of indicators of nonlinearity for use in ultrasound transducer characterizations.

Because the number of applications for medical ultrasonic devices continue to increase and, hence, the number of diagnostic ultrasound (US) systems increase, there is a need to reliably characterize the sources in terms of their output pressures. Currently, the transducers are characterized by making pressure measurements in water for every voltage range applied to the source and, then, linearly derate the measured pressure values to estimate the derated acoustic pressure levels. The process is time-consuming and inaccuracies are introduced in the derating process due to nonlinear effects. Therefore, there is a need to find an indicator of nonlinearity that could classify the measured pressure waveform as either linear, where the derating procedure would yield an accurate derated acoustic pressure estimate, or nonlinear, where the derating process would fail. Eight different indicators of nonlinearity were evaluated experimentally using spherically focused US transducers. The transducers were selected to test the indicator sensitivity to frequency (3 to 8 MHz), f-number (1 and 2), and transducer diameter (1.905 and 5.08 cm). Sensitivity to drive voltage conditions was also tested by exciting one of the transducers with pulses of different duration and phase. None of the eight nonlinearity indicators yielded consistent results. The lack of consistency resulted from the competing effects of nonlinear absorption and asymmetrical distortion, which have yet to be combined into a unified theory.

Acoustics↗